  "method": "Fixed 2026 service and hardware basket repriced under annual conditions",
  "currency": "constant 2026 USD",
  "throughput_calibration": {
    "output_usd_per_m": 15.0,
    "cache_miss_input_usd_per_m": 3.0,
    "cache_hit_input_usd_per_m": 0.3,
    "cache_hit_rate": 0.9,
    "general_input_output_ratio": 4.0,
    "maximum_subsidy_share": 0.25,
    "source": "https://www.kimi.com/blog/kimi-k3",
    "blended_input_usd_per_m": 0.57,
    "api_revenue_usd_per_m_output": 17.28,
    "maximum_production_cost_usd_per_m_output": 23.04,
    "uncalibrated_china_cost_usd_per_m_output": 94.28,
    "throughput_multiplier": 4.092,
    "baseline_output_tps": {
      "general": 900,
      "long_context": 420,
      "agentic": 190
    },
    "calibrated_output_tps": {
      "general": 3683,
      "long_context": 1719,
      "agentic": 777
    },
    "calibrated_china_cost_usd_per_m_output": 23.04,
    "interpretation": "General inference is price-implied; long-context and agentic throughputs apply the same K3 efficiency multiplier."
  },
  "years": [
    2010,
    2011,
    2012,
    2013,
    2014,
    2015,
    2016,
    2017,
    2018,
    2019,
    2020,
    2021,
    2022,
    2023,
    2024,
    2025,
    2026
  ],
  "summary": {
    "datacenter_100mw": {
      "general": {
        "2010": {
          "median": 24.45,
          "mean": 24.74,
          "minimum": 22.3,
          "minimum_country": "China",
          "maximum": 31.22,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 18.11,
            "electricity": 1.8,
            "site_grid": 1.41,
            "operations": 3.3
          },
          "index_2026_100": 97.0
        },
        "2011": {
          "median": 24.27,
          "mean": 24.75,
          "minimum": 22.15,
          "minimum_country": "China",
          "maximum": 31.0,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 17.96,
            "electricity": 1.82,
            "site_grid": 1.35,
            "operations": 3.3
          },
          "index_2026_100": 96.3
        },
        "2012": {
          "median": 23.81,
          "mean": 24.34,
          "minimum": 21.78,
          "minimum_country": "China",
          "maximum": 30.52,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 17.64,
            "electricity": 1.65,
            "site_grid": 1.28,
            "operations": 3.3
          },
          "index_2026_100": 94.5
        },
        "2013": {
          "median": 24.06,
          "mean": 24.54,
          "minimum": 22.0,
          "minimum_country": "China",
          "maximum": 30.8,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 17.79,
            "electricity": 1.71,
            "site_grid": 1.33,
            "operations": 3.3
          },
          "index_2026_100": 95.5
        },
        "2014": {
          "median": 24.17,
          "mean": 24.49,
          "minimum": 22.06,
          "minimum_country": "China",
          "maximum": 30.89,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 17.8,
            "electricity": 1.59,
            "site_grid": 1.37,
            "operations": 3.3
          },
          "index_2026_100": 95.9
        },
        "2015": {
          "median": 23.69,
          "mean": 24.01,
          "minimum": 21.67,
          "minimum_country": "Sweden",
          "maximum": 30.66,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 17.67,
            "electricity": 1.34,
            "site_grid": 1.36,
            "operations": 3.3
          },
          "index_2026_100": 94.0
        },
        "2016": {
          "median": 23.53,
          "mean": 23.82,
          "minimum": 21.69,
          "minimum_country": "Sweden",
          "maximum": 30.44,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 17.57,
            "electricity": 1.31,
            "site_grid": 1.32,
            "operations": 3.3
          },
          "index_2026_100": 93.4
        },
        "2017": {
          "median": 23.63,
          "mean": 24.0,
          "minimum": 21.76,
          "minimum_country": "Finland",
          "maximum": 30.72,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 17.73,
            "electricity": 1.23,
            "site_grid": 1.37,
            "operations": 3.3
          },
          "index_2026_100": 93.8
        },
        "2018": {
          "median": 24.03,
          "mean": 24.33,
          "minimum": 22.07,
          "minimum_country": "Finland",
          "maximum": 31.11,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 17.92,
            "electricity": 1.28,
            "site_grid": 1.46,
            "operations": 3.3
          },
          "index_2026_100": 95.4
        },
        "2019": {
          "median": 23.72,
          "mean": 24.04,
          "minimum": 21.77,
          "minimum_country": "Finland",
          "maximum": 30.76,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 17.67,
            "electricity": 1.33,
            "site_grid": 1.44,
            "operations": 3.3
          },
          "index_2026_100": 94.1
        },
        "2020": {
          "median": 23.47,
          "mean": 23.65,
          "minimum": 21.41,
          "minimum_country": "China",
          "maximum": 30.08,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 17.26,
            "electricity": 1.35,
            "site_grid": 1.38,
            "operations": 3.3
          },
          "index_2026_100": 93.1
        },
        "2021": {
          "median": 23.79,
          "mean": 23.98,
          "minimum": 21.7,
          "minimum_country": "China",
          "maximum": 30.46,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 17.44,
            "electricity": 1.53,
            "site_grid": 1.41,
            "operations": 3.3
          },
          "index_2026_100": 94.4
        },
        "2022": {
          "median": 24.86,
          "mean": 25.16,
          "minimum": 22.42,
          "minimum_country": "Finland",
          "maximum": 31.67,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 17.94,
            "electricity": 1.9,
            "site_grid": 1.76,
            "operations": 3.3
          },
          "index_2026_100": 98.7
        },
        "2023": {
          "median": 25.42,
          "mean": 25.64,
          "minimum": 22.82,
          "minimum_country": "Finland",
          "maximum": 32.24,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 18.27,
            "electricity": 1.71,
            "site_grid": 1.94,
            "operations": 3.3
          },
          "index_2026_100": 100.9
        },
        "2024": {
          "median": 25.24,
          "mean": 25.49,
          "minimum": 22.75,
          "minimum_country": "Finland",
          "maximum": 32.22,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 18.35,
            "electricity": 1.61,
            "site_grid": 1.91,
            "operations": 3.3
          },
          "index_2026_100": 100.2
        },
        "2025": {
          "median": 25.17,
          "mean": 25.49,
          "minimum": 22.71,
          "minimum_country": "Finland",
          "maximum": 32.19,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 18.38,
            "electricity": 1.56,
            "site_grid": 1.89,
            "operations": 3.3
          },
          "index_2026_100": 99.9
        },
        "2026": {
          "median": 25.2,
          "mean": 25.49,
          "minimum": 22.71,
          "minimum_country": "Finland",
          "maximum": 32.21,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 18.4,
            "electricity": 1.58,
            "site_grid": 1.9,
            "operations": 3.3
          },
          "index_2026_100": 100.0
        }
      },
      "long_context": {
        "2010": {
          "median": 54.04,
          "mean": 54.57,
          "minimum": 48.91,
          "minimum_country": "China",
          "maximum": 68.38,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 38.8,
            "electricity": 4.88,
            "site_grid": 3.02,
            "operations": 7.66
          },
          "index_2026_100": 97.0
        },
        "2011": {
          "median": 53.98,
          "mean": 54.65,
          "minimum": 48.6,
          "minimum_country": "China",
          "maximum": 67.93,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 38.49,
            "electricity": 4.94,
            "site_grid": 2.9,
            "operations": 7.66
          },
          "index_2026_100": 96.9
        },
        "2012": {
          "median": 52.62,
          "mean": 53.72,
          "minimum": 47.81,
          "minimum_country": "China",
          "maximum": 66.92,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 37.79,
            "electricity": 4.48,
            "site_grid": 2.75,
            "operations": 7.66
          },
          "index_2026_100": 94.5
        },
        "2013": {
          "median": 53.4,
          "mean": 54.18,
          "minimum": 48.27,
          "minimum_country": "China",
          "maximum": 67.63,
          "maximum_country": "Cyprus",
          "median_components": {
            "hardware": 38.12,
            "electricity": 4.62,
            "site_grid": 2.86,
            "operations": 7.66
          },
          "index_2026_100": 95.9
        },
        "2014": {
          "median": 53.63,
          "mean": 54.03,
          "minimum": 48.38,
          "minimum_country": "China",
          "maximum": 67.66,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 38.14,
            "electricity": 4.3,
            "site_grid": 2.94,
            "operations": 7.66
          },
          "index_2026_100": 96.3
        },
        "2015": {
          "median": 52.37,
          "mean": 52.84,
          "minimum": 47.5,
          "minimum_country": "Sweden",
          "maximum": 67.13,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 37.85,
            "electricity": 3.64,
            "site_grid": 2.91,
            "operations": 7.66
          },
          "index_2026_100": 94.0
        },
        "2016": {
          "median": 51.83,
          "mean": 52.4,
          "minimum": 47.55,
          "minimum_country": "Sweden",
          "maximum": 66.66,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 37.64,
            "electricity": 3.55,
            "site_grid": 2.84,
            "operations": 7.66
          },
          "index_2026_100": 93.0
        },
        "2017": {
          "median": 52.23,
          "mean": 52.78,
          "minimum": 47.74,
          "minimum_country": "Finland",
          "maximum": 67.25,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 37.99,
            "electricity": 3.35,
            "site_grid": 2.94,
            "operations": 7.66
          },
          "index_2026_100": 93.8
        },
        "2018": {
          "median": 52.8,
          "mean": 53.51,
          "minimum": 48.43,
          "minimum_country": "Finland",
          "maximum": 68.11,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 38.4,
            "electricity": 3.48,
            "site_grid": 3.12,
            "operations": 7.66
          },
          "index_2026_100": 94.8
        },
        "2019": {
          "median": 52.31,
          "mean": 52.87,
          "minimum": 47.76,
          "minimum_country": "Finland",
          "maximum": 67.35,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 37.86,
            "electricity": 3.6,
            "site_grid": 3.09,
            "operations": 7.66
          },
          "index_2026_100": 93.9
        },
        "2020": {
          "median": 51.67,
          "mean": 52.04,
          "minimum": 46.93,
          "minimum_country": "China",
          "maximum": 65.87,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 36.97,
            "electricity": 3.67,
            "site_grid": 2.97,
            "operations": 7.66
          },
          "index_2026_100": 92.7
        },
        "2021": {
          "median": 52.49,
          "mean": 52.85,
          "minimum": 47.59,
          "minimum_country": "China",
          "maximum": 66.71,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 37.37,
            "electricity": 4.14,
            "site_grid": 3.02,
            "operations": 7.66
          },
          "index_2026_100": 94.2
        },
        "2022": {
          "median": 55.21,
          "mean": 55.59,
          "minimum": 49.22,
          "minimum_country": "Finland",
          "maximum": 69.37,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 38.43,
            "electricity": 5.14,
            "site_grid": 3.77,
            "operations": 7.66
          },
          "index_2026_100": 99.1
        },
        "2023": {
          "median": 56.29,
          "mean": 56.59,
          "minimum": 50.04,
          "minimum_country": "Finland",
          "maximum": 70.57,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 39.15,
            "electricity": 4.64,
            "site_grid": 4.15,
            "operations": 7.66
          },
          "index_2026_100": 101.0
        },
        "2024": {
          "median": 55.84,
          "mean": 56.15,
          "minimum": 49.82,
          "minimum_country": "Finland",
          "maximum": 70.48,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 39.33,
            "electricity": 4.36,
            "site_grid": 4.09,
            "operations": 7.66
          },
          "index_2026_100": 100.2
        },
        "2025": {
          "median": 55.66,
          "mean": 56.14,
          "minimum": 49.71,
          "minimum_country": "Finland",
          "maximum": 70.39,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 39.39,
            "electricity": 4.22,
            "site_grid": 4.06,
            "operations": 7.66
          },
          "index_2026_100": 99.9
        },
        "2026": {
          "median": 55.71,
          "mean": 56.13,
          "minimum": 49.68,
          "minimum_country": "Finland",
          "maximum": 70.45,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 39.41,
            "electricity": 4.28,
            "site_grid": 4.08,
            "operations": 7.66
          },
          "index_2026_100": 100.0
        }
      },
      "agentic": {
        "2010": {
          "median": 121.58,
          "mean": 122.69,
          "minimum": 109.87,
          "minimum_country": "China",
          "maximum": 153.2,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 85.84,
            "electricity": 11.5,
            "site_grid": 6.68,
            "operations": 18.24
          },
          "index_2026_100": 97.1
        },
        "2011": {
          "median": 121.58,
          "mean": 122.9,
          "minimum": 109.2,
          "minimum_country": "China",
          "maximum": 152.21,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 85.15,
            "electricity": 11.64,
            "site_grid": 6.41,
            "operations": 18.24
          },
          "index_2026_100": 97.1
        },
        "2012": {
          "median": 118.41,
          "mean": 120.82,
          "minimum": 107.45,
          "minimum_country": "China",
          "maximum": 150.39,
          "maximum_country": "Cyprus",
          "median_components": {
            "hardware": 83.6,
            "electricity": 10.54,
            "site_grid": 6.09,
            "operations": 18.24
          },
          "index_2026_100": 94.5
        },
        "2013": {
          "median": 120.05,
          "mean": 121.85,
          "minimum": 108.47,
          "minimum_country": "China",
          "maximum": 152.47,
          "maximum_country": "Cyprus",
          "median_components": {
            "hardware": 84.33,
            "electricity": 10.89,
            "site_grid": 6.32,
            "operations": 18.24
          },
          "index_2026_100": 95.8
        },
        "2014": {
          "median": 120.77,
          "mean": 121.48,
          "minimum": 108.69,
          "minimum_country": "China",
          "maximum": 151.61,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 84.38,
            "electricity": 10.14,
            "site_grid": 6.5,
            "operations": 18.24
          },
          "index_2026_100": 96.4
        },
        "2015": {
          "median": 117.7,
          "mean": 118.75,
          "minimum": 106.7,
          "minimum_country": "Sweden",
          "maximum": 150.41,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 83.75,
            "electricity": 8.56,
            "site_grid": 6.45,
            "operations": 18.24
          },
          "index_2026_100": 94.0
        },
        "2016": {
          "median": 116.4,
          "mean": 117.75,
          "minimum": 106.83,
          "minimum_country": "Sweden",
          "maximum": 149.34,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 83.28,
            "electricity": 8.35,
            "site_grid": 6.28,
            "operations": 18.24
          },
          "index_2026_100": 92.9
        },
        "2017": {
          "median": 117.45,
          "mean": 118.58,
          "minimum": 107.26,
          "minimum_country": "Finland",
          "maximum": 150.66,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 84.05,
            "electricity": 7.88,
            "site_grid": 6.5,
            "operations": 18.24
          },
          "index_2026_100": 93.8
        },
        "2018": {
          "median": 118.73,
          "mean": 120.23,
          "minimum": 108.81,
          "minimum_country": "Finland",
          "maximum": 152.58,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 84.96,
            "electricity": 8.19,
            "site_grid": 6.9,
            "operations": 18.24
          },
          "index_2026_100": 94.8
        },
        "2019": {
          "median": 117.49,
          "mean": 118.8,
          "minimum": 107.32,
          "minimum_country": "Finland",
          "maximum": 150.88,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 83.75,
            "electricity": 8.48,
            "site_grid": 6.84,
            "operations": 18.24
          },
          "index_2026_100": 93.8
        },
        "2020": {
          "median": 116.3,
          "mean": 116.96,
          "minimum": 105.45,
          "minimum_country": "China",
          "maximum": 147.58,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 81.8,
            "electricity": 8.64,
            "site_grid": 6.56,
            "operations": 18.24
          },
          "index_2026_100": 92.8
        },
        "2021": {
          "median": 118.04,
          "mean": 118.83,
          "minimum": 106.93,
          "minimum_country": "China",
          "maximum": 149.47,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 82.67,
            "electricity": 9.76,
            "site_grid": 6.68,
            "operations": 18.24
          },
          "index_2026_100": 94.2
        },
        "2022": {
          "median": 124.35,
          "mean": 125.01,
          "minimum": 110.59,
          "minimum_country": "Finland",
          "maximum": 155.42,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 85.02,
            "electricity": 12.11,
            "site_grid": 8.34,
            "operations": 18.24
          },
          "index_2026_100": 99.3
        },
        "2023": {
          "median": 126.63,
          "mean": 127.23,
          "minimum": 112.38,
          "minimum_country": "Finland",
          "maximum": 158.05,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 86.61,
            "electricity": 10.93,
            "site_grid": 9.19,
            "operations": 18.24
          },
          "index_2026_100": 101.1
        },
        "2024": {
          "median": 125.52,
          "mean": 126.17,
          "minimum": 111.83,
          "minimum_country": "Finland",
          "maximum": 157.82,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 87.0,
            "electricity": 10.27,
            "site_grid": 9.04,
            "operations": 18.24
          },
          "index_2026_100": 100.2
        },
        "2025": {
          "median": 125.21,
          "mean": 126.14,
          "minimum": 111.57,
          "minimum_country": "Finland",
          "maximum": 157.59,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 87.14,
            "electricity": 9.93,
            "site_grid": 8.98,
            "operations": 18.24
          },
          "index_2026_100": 100.0
        },
        "2026": {
          "median": 125.26,
          "mean": 126.1,
          "minimum": 111.5,
          "minimum_country": "Finland",
          "maximum": 157.72,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 87.2,
            "electricity": 10.07,
            "site_grid": 9.02,
            "operations": 18.24
          },
          "index_2026_100": 100.0
        }
      }
    },
    "onprem_250kw": {
      "general": {
        "2010": {
          "median": 32.31,
          "mean": 32.66,
          "minimum": 29.09,
          "minimum_country": "China",
          "maximum": 40.09,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 22.77,
            "electricity": 2.29,
            "site_grid": 1.39,
            "operations": 6.03
          },
          "index_2026_100": 97.0
        },
        "2011": {
          "median": 32.22,
          "mean": 32.68,
          "minimum": 28.92,
          "minimum_country": "China",
          "maximum": 39.84,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 22.59,
            "electricity": 2.33,
            "site_grid": 1.36,
            "operations": 6.03
          },
          "index_2026_100": 96.7
        },
        "2012": {
          "median": 31.58,
          "mean": 32.18,
          "minimum": 28.5,
          "minimum_country": "China",
          "maximum": 39.29,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 22.18,
            "electricity": 2.12,
            "site_grid": 1.3,
            "operations": 6.03
          },
          "index_2026_100": 94.8
        },
        "2013": {
          "median": 32.08,
          "mean": 32.43,
          "minimum": 28.74,
          "minimum_country": "China",
          "maximum": 39.61,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 22.4,
            "electricity": 2.19,
            "site_grid": 1.35,
            "operations": 6.03
          },
          "index_2026_100": 96.3
        },
        "2014": {
          "median": 32.02,
          "mean": 32.36,
          "minimum": 28.8,
          "minimum_country": "China",
          "maximum": 39.69,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 22.43,
            "electricity": 2.04,
            "site_grid": 1.36,
            "operations": 6.03
          },
          "index_2026_100": 96.1
        },
        "2015": {
          "median": 31.41,
          "mean": 31.76,
          "minimum": 28.57,
          "minimum_country": "China",
          "maximum": 39.41,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 22.26,
            "electricity": 1.72,
            "site_grid": 1.35,
            "operations": 6.03
          },
          "index_2026_100": 94.3
        },
        "2016": {
          "median": 31.27,
          "mean": 31.52,
          "minimum": 28.38,
          "minimum_country": "China",
          "maximum": 39.16,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 22.14,
            "electricity": 1.67,
            "site_grid": 1.32,
            "operations": 6.03
          },
          "index_2026_100": 93.9
        },
        "2017": {
          "median": 31.47,
          "mean": 31.75,
          "minimum": 28.63,
          "minimum_country": "China",
          "maximum": 39.48,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 22.34,
            "electricity": 1.58,
            "site_grid": 1.35,
            "operations": 6.03
          },
          "index_2026_100": 94.5
        },
        "2018": {
          "median": 31.87,
          "mean": 32.13,
          "minimum": 28.98,
          "minimum_country": "China",
          "maximum": 39.93,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 22.58,
            "electricity": 1.65,
            "site_grid": 1.42,
            "operations": 6.03
          },
          "index_2026_100": 95.7
        },
        "2019": {
          "median": 31.47,
          "mean": 31.77,
          "minimum": 28.63,
          "minimum_country": "China",
          "maximum": 39.5,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 22.26,
            "electricity": 1.7,
            "site_grid": 1.42,
            "operations": 6.03
          },
          "index_2026_100": 94.5
        },
        "2020": {
          "median": 30.95,
          "mean": 31.25,
          "minimum": 28.02,
          "minimum_country": "China",
          "maximum": 38.7,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 21.75,
            "electricity": 1.73,
            "site_grid": 1.35,
            "operations": 6.03
          },
          "index_2026_100": 92.9
        },
        "2021": {
          "median": 31.28,
          "mean": 31.69,
          "minimum": 28.36,
          "minimum_country": "China",
          "maximum": 39.14,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 21.98,
            "electricity": 1.97,
            "site_grid": 1.4,
            "operations": 6.03
          },
          "index_2026_100": 93.9
        },
        "2022": {
          "median": 32.75,
          "mean": 33.1,
          "minimum": 29.37,
          "minimum_country": "China",
          "maximum": 40.48,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 22.6,
            "electricity": 2.43,
            "site_grid": 1.72,
            "operations": 6.03
          },
          "index_2026_100": 98.3
        },
        "2023": {
          "median": 33.66,
          "mean": 33.63,
          "minimum": 29.83,
          "minimum_country": "China",
          "maximum": 41.1,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 23.02,
            "electricity": 2.2,
            "site_grid": 1.88,
            "operations": 6.03
          },
          "index_2026_100": 101.1
        },
        "2024": {
          "median": 33.31,
          "mean": 33.44,
          "minimum": 29.84,
          "minimum_country": "China",
          "maximum": 41.08,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 23.12,
            "electricity": 2.05,
            "site_grid": 1.84,
            "operations": 6.03
          },
          "index_2026_100": 100.0
        },
        "2025": {
          "median": 33.35,
          "mean": 33.44,
          "minimum": 29.82,
          "minimum_country": "China",
          "maximum": 41.05,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 23.16,
            "electricity": 1.99,
            "site_grid": 1.82,
            "operations": 6.03
          },
          "index_2026_100": 100.1
        },
        "2026": {
          "median": 33.31,
          "mean": 33.43,
          "minimum": 29.84,
          "minimum_country": "China",
          "maximum": 41.08,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 23.17,
            "electricity": 2.03,
            "site_grid": 1.83,
            "operations": 6.03
          },
          "index_2026_100": 100.0
        }
      },
      "long_context": {
        "2010": {
          "median": 71.85,
          "mean": 72.46,
          "minimum": 64.24,
          "minimum_country": "China",
          "maximum": 88.29,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 48.79,
            "electricity": 6.2,
            "site_grid": 2.98,
            "operations": 14.13
          },
          "index_2026_100": 96.9
        },
        "2011": {
          "median": 71.8,
          "mean": 72.57,
          "minimum": 63.91,
          "minimum_country": "China",
          "maximum": 87.79,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 48.4,
            "electricity": 6.33,
            "site_grid": 2.91,
            "operations": 14.13
          },
          "index_2026_100": 96.8
        },
        "2012": {
          "median": 70.24,
          "mean": 71.43,
          "minimum": 63.0,
          "minimum_country": "China",
          "maximum": 87.53,
          "maximum_country": "Cyprus",
          "median_components": {
            "hardware": 47.53,
            "electricity": 5.75,
            "site_grid": 2.78,
            "operations": 14.13
          },
          "index_2026_100": 94.7
        },
        "2013": {
          "median": 71.12,
          "mean": 72.01,
          "minimum": 63.52,
          "minimum_country": "China",
          "maximum": 88.54,
          "maximum_country": "Cyprus",
          "median_components": {
            "hardware": 47.99,
            "electricity": 5.93,
            "site_grid": 2.89,
            "operations": 14.13
          },
          "index_2026_100": 95.9
        },
        "2014": {
          "median": 71.17,
          "mean": 71.8,
          "minimum": 63.62,
          "minimum_country": "China",
          "maximum": 87.44,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 48.05,
            "electricity": 5.54,
            "site_grid": 2.91,
            "operations": 14.13
          },
          "index_2026_100": 96.0
        },
        "2015": {
          "median": 69.28,
          "mean": 70.31,
          "minimum": 63.09,
          "minimum_country": "China",
          "maximum": 86.79,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 47.69,
            "electricity": 4.65,
            "site_grid": 2.9,
            "operations": 14.13
          },
          "index_2026_100": 93.4
        },
        "2016": {
          "median": 69.07,
          "mean": 69.76,
          "minimum": 62.66,
          "minimum_country": "China",
          "maximum": 86.22,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 47.43,
            "electricity": 4.54,
            "site_grid": 2.83,
            "operations": 14.13
          },
          "index_2026_100": 93.2
        },
        "2017": {
          "median": 69.46,
          "mean": 70.23,
          "minimum": 63.21,
          "minimum_country": "China",
          "maximum": 86.92,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 47.86,
            "electricity": 4.29,
            "site_grid": 2.89,
            "operations": 14.13
          },
          "index_2026_100": 93.7
        },
        "2018": {
          "median": 70.5,
          "mean": 71.1,
          "minimum": 63.99,
          "minimum_country": "China",
          "maximum": 87.9,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 48.38,
            "electricity": 4.46,
            "site_grid": 3.05,
            "operations": 14.13
          },
          "index_2026_100": 95.1
        },
        "2019": {
          "median": 69.77,
          "mean": 70.31,
          "minimum": 63.21,
          "minimum_country": "China",
          "maximum": 86.97,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 47.7,
            "electricity": 4.6,
            "site_grid": 3.04,
            "operations": 14.13
          },
          "index_2026_100": 94.1
        },
        "2020": {
          "median": 68.68,
          "mean": 69.19,
          "minimum": 61.87,
          "minimum_country": "China",
          "maximum": 85.22,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 46.59,
            "electricity": 4.7,
            "site_grid": 2.88,
            "operations": 14.13
          },
          "index_2026_100": 92.6
        },
        "2021": {
          "median": 69.38,
          "mean": 70.26,
          "minimum": 62.65,
          "minimum_country": "China",
          "maximum": 86.21,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 47.08,
            "electricity": 5.33,
            "site_grid": 2.99,
            "operations": 14.13
          },
          "index_2026_100": 93.6
        },
        "2022": {
          "median": 72.87,
          "mean": 73.55,
          "minimum": 64.87,
          "minimum_country": "China",
          "maximum": 89.17,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 48.41,
            "electricity": 6.59,
            "site_grid": 3.68,
            "operations": 14.13
          },
          "index_2026_100": 98.3
        },
        "2023": {
          "median": 75.05,
          "mean": 74.65,
          "minimum": 65.82,
          "minimum_country": "China",
          "maximum": 90.47,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 49.31,
            "electricity": 5.96,
            "site_grid": 4.02,
            "operations": 14.13
          },
          "index_2026_100": 101.2
        },
        "2024": {
          "median": 73.77,
          "mean": 74.09,
          "minimum": 65.82,
          "minimum_country": "China",
          "maximum": 90.37,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 49.53,
            "electricity": 5.57,
            "site_grid": 3.94,
            "operations": 14.13
          },
          "index_2026_100": 99.5
        },
        "2025": {
          "median": 74.24,
          "mean": 74.08,
          "minimum": 65.74,
          "minimum_country": "China",
          "maximum": 90.27,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 49.61,
            "electricity": 5.4,
            "site_grid": 3.91,
            "operations": 14.13
          },
          "index_2026_100": 100.1
        },
        "2026": {
          "median": 74.14,
          "mean": 74.05,
          "minimum": 65.79,
          "minimum_country": "China",
          "maximum": 90.33,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 49.65,
            "electricity": 5.49,
            "site_grid": 3.93,
            "operations": 14.13
          },
          "index_2026_100": 100.0
        }
      },
      "agentic": {
        "2010": {
          "median": 162.66,
          "mean": 163.86,
          "minimum": 145.28,
          "minimum_country": "China",
          "maximum": 198.85,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 107.95,
            "electricity": 14.59,
            "site_grid": 6.58,
            "operations": 33.96
          },
          "index_2026_100": 97.0
        },
        "2011": {
          "median": 162.6,
          "mean": 164.16,
          "minimum": 144.56,
          "minimum_country": "China",
          "maximum": 197.77,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 107.09,
            "electricity": 14.9,
            "site_grid": 6.43,
            "operations": 33.96
          },
          "index_2026_100": 96.9
        },
        "2012": {
          "median": 159.02,
          "mean": 161.59,
          "minimum": 142.56,
          "minimum_country": "China",
          "maximum": 198.55,
          "maximum_country": "Cyprus",
          "median_components": {
            "hardware": 105.15,
            "electricity": 13.54,
            "site_grid": 6.15,
            "operations": 33.96
          },
          "index_2026_100": 94.8
        },
        "2013": {
          "median": 160.76,
          "mean": 162.88,
          "minimum": 143.7,
          "minimum_country": "China",
          "maximum": 200.59,
          "maximum_country": "Cyprus",
          "median_components": {
            "hardware": 106.17,
            "electricity": 13.96,
            "site_grid": 6.4,
            "operations": 33.96
          },
          "index_2026_100": 95.8
        },
        "2014": {
          "median": 160.89,
          "mean": 162.4,
          "minimum": 143.91,
          "minimum_country": "China",
          "maximum": 196.96,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 106.3,
            "electricity": 13.05,
            "site_grid": 6.44,
            "operations": 33.96
          },
          "index_2026_100": 95.9
        },
        "2015": {
          "median": 156.6,
          "mean": 158.96,
          "minimum": 142.71,
          "minimum_country": "China",
          "maximum": 195.49,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 105.51,
            "electricity": 10.95,
            "site_grid": 6.41,
            "operations": 33.96
          },
          "index_2026_100": 93.4
        },
        "2016": {
          "median": 156.08,
          "mean": 157.71,
          "minimum": 141.74,
          "minimum_country": "China",
          "maximum": 194.22,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 104.93,
            "electricity": 10.69,
            "site_grid": 6.26,
            "operations": 33.96
          },
          "index_2026_100": 93.1
        },
        "2017": {
          "median": 156.93,
          "mean": 158.73,
          "minimum": 142.96,
          "minimum_country": "China",
          "maximum": 195.76,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 105.89,
            "electricity": 10.11,
            "site_grid": 6.39,
            "operations": 33.96
          },
          "index_2026_100": 93.6
        },
        "2018": {
          "median": 159.28,
          "mean": 160.69,
          "minimum": 144.71,
          "minimum_country": "China",
          "maximum": 197.96,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 107.03,
            "electricity": 10.51,
            "site_grid": 6.75,
            "operations": 33.96
          },
          "index_2026_100": 95.0
        },
        "2019": {
          "median": 157.62,
          "mean": 158.93,
          "minimum": 142.97,
          "minimum_country": "China",
          "maximum": 195.88,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 105.52,
            "electricity": 10.84,
            "site_grid": 6.73,
            "operations": 33.96
          },
          "index_2026_100": 94.0
        },
        "2020": {
          "median": 155.43,
          "mean": 156.45,
          "minimum": 140.0,
          "minimum_country": "China",
          "maximum": 191.99,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 103.08,
            "electricity": 11.07,
            "site_grid": 6.38,
            "operations": 33.96
          },
          "index_2026_100": 92.7
        },
        "2021": {
          "median": 156.98,
          "mean": 158.9,
          "minimum": 141.74,
          "minimum_country": "China",
          "maximum": 194.22,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 104.16,
            "electricity": 12.56,
            "site_grid": 6.62,
            "operations": 33.96
          },
          "index_2026_100": 93.6
        },
        "2022": {
          "median": 165.09,
          "mean": 166.36,
          "minimum": 146.71,
          "minimum_country": "China",
          "maximum": 200.83,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 107.11,
            "electricity": 15.51,
            "site_grid": 8.15,
            "operations": 33.96
          },
          "index_2026_100": 98.4
        },
        "2023": {
          "median": 169.91,
          "mean": 168.79,
          "minimum": 148.79,
          "minimum_country": "China",
          "maximum": 203.66,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 109.1,
            "electricity": 14.03,
            "site_grid": 8.89,
            "operations": 33.96
          },
          "index_2026_100": 101.3
        },
        "2024": {
          "median": 166.9,
          "mean": 167.45,
          "minimum": 148.75,
          "minimum_country": "China",
          "maximum": 203.43,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 109.59,
            "electricity": 13.11,
            "site_grid": 8.72,
            "operations": 33.96
          },
          "index_2026_100": 99.5
        },
        "2025": {
          "median": 167.72,
          "mean": 167.41,
          "minimum": 148.56,
          "minimum_country": "China",
          "maximum": 203.17,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 109.76,
            "electricity": 12.71,
            "site_grid": 8.65,
            "operations": 33.96
          },
          "index_2026_100": 100.0
        },
        "2026": {
          "median": 167.73,
          "mean": 167.33,
          "minimum": 148.67,
          "minimum_country": "China",
          "maximum": 203.31,
          "maximum_country": "Brazil",
          "median_components": {
            "hardware": 109.83,
            "electricity": 12.94,
            "site_grid": 8.69,
            "operations": 33.96
          },
          "index_2026_100": 100.0
        }
      }
    }
  },
  "results": [
    {
      "year": 2010,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.34,
      "electricity": 2.12,
      "site_grid": 1.41,
      "operations": 3.32,
      "total": 24.19,
      "electricity_usd_2026_kwh": 0.2266,
      "wacc": 0.0588,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.82,
      "electricity": 2.72,
      "site_grid": 1.36,
      "operations": 6.48,
      "total": 32.39,
      "electricity_usd_2026_kwh": 0.2266,
      "wacc": 0.0588,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.16,
      "electricity": 5.76,
      "site_grid": 3.01,
      "operations": 7.7,
      "total": 53.62,
      "electricity_usd_2026_kwh": 0.2266,
      "wacc": 0.0588,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.76,
      "electricity": 7.37,
      "site_grid": 2.92,
      "operations": 15.1,
      "total": 72.15,
      "electricity_usd_2026_kwh": 0.2266,
      "wacc": 0.0588,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.2,
      "electricity": 13.56,
      "site_grid": 6.66,
      "operations": 18.32,
      "total": 120.75,
      "electricity_usd_2026_kwh": 0.2266,
      "wacc": 0.0588,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.44,
      "electricity": 17.37,
      "site_grid": 6.47,
      "operations": 36.09,
      "total": 163.37,
      "electricity_usd_2026_kwh": 0.2266,
      "wacc": 0.0588,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.2,
      "electricity": 2.16,
      "site_grid": 1.35,
      "operations": 3.32,
      "total": 24.03,
      "electricity_usd_2026_kwh": 0.2306,
      "wacc": 0.0545,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.65,
      "electricity": 2.77,
      "site_grid": 1.31,
      "operations": 6.48,
      "total": 32.21,
      "electricity_usd_2026_kwh": 0.2306,
      "wacc": 0.0545,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.86,
      "electricity": 5.86,
      "site_grid": 2.88,
      "operations": 7.7,
      "total": 53.3,
      "electricity_usd_2026_kwh": 0.2306,
      "wacc": 0.0545,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.38,
      "electricity": 7.5,
      "site_grid": 2.82,
      "operations": 15.1,
      "total": 71.8,
      "electricity_usd_2026_kwh": 0.2306,
      "wacc": 0.0545,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.54,
      "electricity": 13.8,
      "site_grid": 6.38,
      "operations": 18.32,
      "total": 120.04,
      "electricity_usd_2026_kwh": 0.2306,
      "wacc": 0.0545,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.61,
      "electricity": 17.67,
      "site_grid": 6.23,
      "operations": 36.09,
      "total": 162.6,
      "electricity_usd_2026_kwh": 0.2306,
      "wacc": 0.0545,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.89,
      "electricity": 1.92,
      "site_grid": 1.26,
      "operations": 3.32,
      "total": 23.4,
      "electricity_usd_2026_kwh": 0.2052,
      "wacc": 0.0447,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.25,
      "electricity": 2.46,
      "site_grid": 1.25,
      "operations": 6.48,
      "total": 31.45,
      "electricity_usd_2026_kwh": 0.2052,
      "wacc": 0.0447,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.18,
      "electricity": 5.21,
      "site_grid": 2.71,
      "operations": 7.7,
      "total": 51.8,
      "electricity_usd_2026_kwh": 0.2052,
      "wacc": 0.0447,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.54,
      "electricity": 6.68,
      "site_grid": 2.68,
      "operations": 15.1,
      "total": 69.99,
      "electricity_usd_2026_kwh": 0.2052,
      "wacc": 0.0447,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.05,
      "electricity": 12.28,
      "site_grid": 5.99,
      "operations": 18.32,
      "total": 116.64,
      "electricity_usd_2026_kwh": 0.2052,
      "wacc": 0.0447,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.75,
      "electricity": 15.72,
      "site_grid": 5.92,
      "operations": 36.09,
      "total": 158.49,
      "electricity_usd_2026_kwh": 0.2052,
      "wacc": 0.0447,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.06,
      "electricity": 1.96,
      "site_grid": 1.32,
      "operations": 3.32,
      "total": 23.67,
      "electricity_usd_2026_kwh": 0.2094,
      "wacc": 0.0502,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.47,
      "electricity": 2.51,
      "site_grid": 1.3,
      "operations": 6.48,
      "total": 31.77,
      "electricity_usd_2026_kwh": 0.2094,
      "wacc": 0.0502,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.56,
      "electricity": 5.32,
      "site_grid": 2.84,
      "operations": 7.7,
      "total": 52.41,
      "electricity_usd_2026_kwh": 0.2094,
      "wacc": 0.0502,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.01,
      "electricity": 6.81,
      "site_grid": 2.79,
      "operations": 15.1,
      "total": 70.7,
      "electricity_usd_2026_kwh": 0.2094,
      "wacc": 0.0502,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.88,
      "electricity": 12.53,
      "site_grid": 6.28,
      "operations": 18.32,
      "total": 118.01,
      "electricity_usd_2026_kwh": 0.2094,
      "wacc": 0.0502,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.79,
      "electricity": 16.04,
      "site_grid": 6.16,
      "operations": 36.09,
      "total": 160.09,
      "electricity_usd_2026_kwh": 0.2094,
      "wacc": 0.0502,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.12,
      "electricity": 1.86,
      "site_grid": 1.36,
      "operations": 3.32,
      "total": 23.67,
      "electricity_usd_2026_kwh": 0.1989,
      "wacc": 0.0521,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.55,
      "electricity": 2.39,
      "site_grid": 1.33,
      "operations": 6.48,
      "total": 31.75,
      "electricity_usd_2026_kwh": 0.1989,
      "wacc": 0.0521,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.69,
      "electricity": 5.05,
      "site_grid": 2.92,
      "operations": 7.7,
      "total": 52.36,
      "electricity_usd_2026_kwh": 0.1989,
      "wacc": 0.0521,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.17,
      "electricity": 6.47,
      "site_grid": 2.86,
      "operations": 15.1,
      "total": 70.6,
      "electricity_usd_2026_kwh": 0.1989,
      "wacc": 0.0521,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.17,
      "electricity": 11.9,
      "site_grid": 6.46,
      "operations": 18.32,
      "total": 117.86,
      "electricity_usd_2026_kwh": 0.1989,
      "wacc": 0.0521,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.15,
      "electricity": 15.25,
      "site_grid": 6.33,
      "operations": 36.09,
      "total": 159.82,
      "electricity_usd_2026_kwh": 0.1989,
      "wacc": 0.0521,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.0,
      "electricity": 1.51,
      "site_grid": 1.35,
      "operations": 3.32,
      "total": 23.18,
      "electricity_usd_2026_kwh": 0.1615,
      "wacc": 0.0481,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.39,
      "electricity": 1.94,
      "site_grid": 1.33,
      "operations": 6.48,
      "total": 31.13,
      "electricity_usd_2026_kwh": 0.1615,
      "wacc": 0.0481,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.41,
      "electricity": 4.1,
      "site_grid": 2.89,
      "operations": 7.7,
      "total": 51.11,
      "electricity_usd_2026_kwh": 0.1615,
      "wacc": 0.0481,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.83,
      "electricity": 5.25,
      "site_grid": 2.85,
      "operations": 15.1,
      "total": 69.02,
      "electricity_usd_2026_kwh": 0.1615,
      "wacc": 0.0481,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.56,
      "electricity": 9.66,
      "site_grid": 6.4,
      "operations": 18.32,
      "total": 114.94,
      "electricity_usd_2026_kwh": 0.1615,
      "wacc": 0.0481,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.39,
      "electricity": 12.37,
      "site_grid": 6.3,
      "operations": 36.09,
      "total": 156.15,
      "electricity_usd_2026_kwh": 0.1615,
      "wacc": 0.0481,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.9,
      "electricity": 1.45,
      "site_grid": 1.31,
      "operations": 3.32,
      "total": 22.98,
      "electricity_usd_2026_kwh": 0.1547,
      "wacc": 0.0451,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.27,
      "electricity": 1.86,
      "site_grid": 1.3,
      "operations": 6.48,
      "total": 30.9,
      "electricity_usd_2026_kwh": 0.1547,
      "wacc": 0.0451,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.21,
      "electricity": 3.93,
      "site_grid": 2.81,
      "operations": 7.7,
      "total": 50.65,
      "electricity_usd_2026_kwh": 0.1547,
      "wacc": 0.0451,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.57,
      "electricity": 5.04,
      "site_grid": 2.78,
      "operations": 15.1,
      "total": 68.48,
      "electricity_usd_2026_kwh": 0.1547,
      "wacc": 0.0451,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.1,
      "electricity": 9.26,
      "site_grid": 6.22,
      "operations": 18.32,
      "total": 113.9,
      "electricity_usd_2026_kwh": 0.1547,
      "wacc": 0.0451,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.81,
      "electricity": 11.86,
      "site_grid": 6.15,
      "operations": 36.09,
      "total": 154.91,
      "electricity_usd_2026_kwh": 0.1547,
      "wacc": 0.0451,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.06,
      "electricity": 1.38,
      "site_grid": 1.36,
      "operations": 3.32,
      "total": 23.12,
      "electricity_usd_2026_kwh": 0.1468,
      "wacc": 0.05,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.47,
      "electricity": 1.76,
      "site_grid": 1.34,
      "operations": 6.48,
      "total": 31.05,
      "electricity_usd_2026_kwh": 0.1468,
      "wacc": 0.05,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.54,
      "electricity": 3.73,
      "site_grid": 2.92,
      "operations": 7.7,
      "total": 50.9,
      "electricity_usd_2026_kwh": 0.1468,
      "wacc": 0.05,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.99,
      "electricity": 4.78,
      "site_grid": 2.87,
      "operations": 15.1,
      "total": 68.74,
      "electricity_usd_2026_kwh": 0.1468,
      "wacc": 0.05,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.85,
      "electricity": 8.79,
      "site_grid": 6.47,
      "operations": 18.32,
      "total": 114.42,
      "electricity_usd_2026_kwh": 0.1468,
      "wacc": 0.05,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.75,
      "electricity": 11.25,
      "site_grid": 6.35,
      "operations": 36.09,
      "total": 155.44,
      "electricity_usd_2026_kwh": 0.1468,
      "wacc": 0.05,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.24,
      "electricity": 1.46,
      "site_grid": 1.45,
      "operations": 3.32,
      "total": 23.48,
      "electricity_usd_2026_kwh": 0.1562,
      "wacc": 0.0558,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.7,
      "electricity": 1.87,
      "site_grid": 1.41,
      "operations": 6.48,
      "total": 31.47,
      "electricity_usd_2026_kwh": 0.1562,
      "wacc": 0.0558,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.95,
      "electricity": 3.97,
      "site_grid": 3.11,
      "operations": 7.7,
      "total": 51.72,
      "electricity_usd_2026_kwh": 0.1562,
      "wacc": 0.0558,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.49,
      "electricity": 5.08,
      "site_grid": 3.03,
      "operations": 15.1,
      "total": 69.7,
      "electricity_usd_2026_kwh": 0.1562,
      "wacc": 0.0558,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.74,
      "electricity": 9.34,
      "site_grid": 6.88,
      "operations": 18.32,
      "total": 116.29,
      "electricity_usd_2026_kwh": 0.1562,
      "wacc": 0.0558,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.86,
      "electricity": 11.97,
      "site_grid": 6.71,
      "operations": 36.09,
      "total": 157.63,
      "electricity_usd_2026_kwh": 0.1562,
      "wacc": 0.0558,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.0,
      "electricity": 1.47,
      "site_grid": 1.43,
      "operations": 3.32,
      "total": 23.22,
      "electricity_usd_2026_kwh": 0.1567,
      "wacc": 0.0481,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.39,
      "electricity": 1.88,
      "site_grid": 1.41,
      "operations": 6.48,
      "total": 31.16,
      "electricity_usd_2026_kwh": 0.1567,
      "wacc": 0.0481,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.41,
      "electricity": 3.98,
      "site_grid": 3.07,
      "operations": 7.7,
      "total": 51.16,
      "electricity_usd_2026_kwh": 0.1567,
      "wacc": 0.0481,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.83,
      "electricity": 5.1,
      "site_grid": 3.02,
      "operations": 15.1,
      "total": 69.05,
      "electricity_usd_2026_kwh": 0.1567,
      "wacc": 0.0481,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.56,
      "electricity": 9.38,
      "site_grid": 6.79,
      "operations": 18.32,
      "total": 115.05,
      "electricity_usd_2026_kwh": 0.1567,
      "wacc": 0.0481,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.39,
      "electricity": 12.01,
      "site_grid": 6.68,
      "operations": 36.09,
      "total": 156.17,
      "electricity_usd_2026_kwh": 0.1567,
      "wacc": 0.0481,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.74,
      "electricity": 1.62,
      "site_grid": 1.38,
      "operations": 3.32,
      "total": 23.06,
      "electricity_usd_2026_kwh": 0.1732,
      "wacc": 0.0356,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.89,
      "electricity": 2.08,
      "site_grid": 1.33,
      "operations": 6.48,
      "total": 30.78,
      "electricity_usd_2026_kwh": 0.1732,
      "wacc": 0.0356,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.86,
      "electricity": 4.4,
      "site_grid": 2.95,
      "operations": 7.7,
      "total": 50.9,
      "electricity_usd_2026_kwh": 0.1732,
      "wacc": 0.0356,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.76,
      "electricity": 5.64,
      "site_grid": 2.86,
      "operations": 15.1,
      "total": 68.35,
      "electricity_usd_2026_kwh": 0.1732,
      "wacc": 0.0356,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.33,
      "electricity": 10.36,
      "site_grid": 6.52,
      "operations": 18.32,
      "total": 114.53,
      "electricity_usd_2026_kwh": 0.1732,
      "wacc": 0.0356,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.02,
      "electricity": 13.27,
      "site_grid": 6.32,
      "operations": 36.09,
      "total": 154.7,
      "electricity_usd_2026_kwh": 0.1732,
      "wacc": 0.0356,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.77,
      "electricity": 1.69,
      "site_grid": 1.39,
      "operations": 3.32,
      "total": 23.18,
      "electricity_usd_2026_kwh": 0.1808,
      "wacc": 0.0412,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.11,
      "electricity": 2.17,
      "site_grid": 1.39,
      "operations": 6.48,
      "total": 31.15,
      "electricity_usd_2026_kwh": 0.1808,
      "wacc": 0.0412,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.94,
      "electricity": 4.59,
      "site_grid": 2.99,
      "operations": 7.7,
      "total": 51.22,
      "electricity_usd_2026_kwh": 0.1808,
      "wacc": 0.0412,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.23,
      "electricity": 5.88,
      "site_grid": 2.97,
      "operations": 15.1,
      "total": 69.18,
      "electricity_usd_2026_kwh": 0.1808,
      "wacc": 0.0412,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.51,
      "electricity": 10.82,
      "site_grid": 6.61,
      "operations": 18.32,
      "total": 115.25,
      "electricity_usd_2026_kwh": 0.1808,
      "wacc": 0.0412,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.07,
      "electricity": 13.86,
      "site_grid": 6.56,
      "operations": 36.09,
      "total": 156.58,
      "electricity_usd_2026_kwh": 0.1808,
      "wacc": 0.0412,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.26,
      "electricity": 1.9,
      "site_grid": 1.75,
      "operations": 3.32,
      "total": 24.23,
      "electricity_usd_2026_kwh": 0.2024,
      "wacc": 0.0562,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.72,
      "electricity": 2.43,
      "site_grid": 1.71,
      "operations": 6.48,
      "total": 32.33,
      "electricity_usd_2026_kwh": 0.2024,
      "wacc": 0.0562,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.97,
      "electricity": 5.14,
      "site_grid": 3.76,
      "operations": 7.7,
      "total": 53.57,
      "electricity_usd_2026_kwh": 0.2024,
      "wacc": 0.0562,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.53,
      "electricity": 6.59,
      "site_grid": 3.66,
      "operations": 15.1,
      "total": 71.87,
      "electricity_usd_2026_kwh": 0.2024,
      "wacc": 0.0562,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.8,
      "electricity": 12.11,
      "site_grid": 8.31,
      "operations": 18.32,
      "total": 120.54,
      "electricity_usd_2026_kwh": 0.2024,
      "wacc": 0.0562,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.94,
      "electricity": 15.51,
      "site_grid": 8.09,
      "operations": 36.09,
      "total": 162.63,
      "electricity_usd_2026_kwh": 0.2024,
      "wacc": 0.0562,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.58,
      "electricity": 2.79,
      "site_grid": 1.94,
      "operations": 3.32,
      "total": 25.63,
      "electricity_usd_2026_kwh": 0.2974,
      "wacc": 0.0663,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.12,
      "electricity": 3.57,
      "site_grid": 1.86,
      "operations": 6.48,
      "total": 34.04,
      "electricity_usd_2026_kwh": 0.2974,
      "wacc": 0.0663,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.67,
      "electricity": 7.56,
      "site_grid": 4.15,
      "operations": 7.7,
      "total": 57.08,
      "electricity_usd_2026_kwh": 0.2974,
      "wacc": 0.0663,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.4,
      "electricity": 9.68,
      "site_grid": 3.99,
      "operations": 15.1,
      "total": 76.17,
      "electricity_usd_2026_kwh": 0.2974,
      "wacc": 0.0663,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.35,
      "electricity": 17.8,
      "site_grid": 9.19,
      "operations": 18.32,
      "total": 128.65,
      "electricity_usd_2026_kwh": 0.2974,
      "wacc": 0.0663,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.87,
      "electricity": 22.79,
      "site_grid": 8.84,
      "operations": 36.09,
      "total": 172.59,
      "electricity_usd_2026_kwh": 0.2974,
      "wacc": 0.0663,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.66,
      "electricity": 2.13,
      "site_grid": 1.91,
      "operations": 3.32,
      "total": 25.03,
      "electricity_usd_2026_kwh": 0.2276,
      "wacc": 0.0688,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.23,
      "electricity": 2.73,
      "site_grid": 1.83,
      "operations": 6.48,
      "total": 33.27,
      "electricity_usd_2026_kwh": 0.2276,
      "wacc": 0.0688,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.85,
      "electricity": 5.78,
      "site_grid": 4.09,
      "operations": 7.7,
      "total": 55.42,
      "electricity_usd_2026_kwh": 0.2276,
      "wacc": 0.0688,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.62,
      "electricity": 7.41,
      "site_grid": 3.92,
      "operations": 15.1,
      "total": 74.04,
      "electricity_usd_2026_kwh": 0.2276,
      "wacc": 0.0688,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.73,
      "electricity": 13.62,
      "site_grid": 9.04,
      "operations": 18.32,
      "total": 124.71,
      "electricity_usd_2026_kwh": 0.2276,
      "wacc": 0.0688,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.35,
      "electricity": 17.44,
      "site_grid": 8.67,
      "operations": 36.09,
      "total": 167.56,
      "electricity_usd_2026_kwh": 0.2276,
      "wacc": 0.0688,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.69,
      "electricity": 2.18,
      "site_grid": 1.89,
      "operations": 3.32,
      "total": 25.09,
      "electricity_usd_2026_kwh": 0.2329,
      "wacc": 0.0696,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.26,
      "electricity": 2.8,
      "site_grid": 1.81,
      "operations": 6.48,
      "total": 33.35,
      "electricity_usd_2026_kwh": 0.2329,
      "wacc": 0.0696,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.91,
      "electricity": 5.92,
      "site_grid": 4.06,
      "operations": 7.7,
      "total": 55.58,
      "electricity_usd_2026_kwh": 0.2329,
      "wacc": 0.0696,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.69,
      "electricity": 7.58,
      "site_grid": 3.89,
      "operations": 15.1,
      "total": 74.26,
      "electricity_usd_2026_kwh": 0.2329,
      "wacc": 0.0696,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.86,
      "electricity": 13.94,
      "site_grid": 8.98,
      "operations": 18.32,
      "total": 125.09,
      "electricity_usd_2026_kwh": 0.2329,
      "wacc": 0.0696,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.52,
      "electricity": 17.85,
      "site_grid": 8.6,
      "operations": 36.09,
      "total": 168.05,
      "electricity_usd_2026_kwh": 0.2329,
      "wacc": 0.0696,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.7,
      "electricity": 2.13,
      "site_grid": 1.9,
      "operations": 3.32,
      "total": 25.06,
      "electricity_usd_2026_kwh": 0.2277,
      "wacc": 0.07,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.28,
      "electricity": 2.73,
      "site_grid": 1.82,
      "operations": 6.48,
      "total": 33.31,
      "electricity_usd_2026_kwh": 0.2277,
      "wacc": 0.07,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.93,
      "electricity": 5.79,
      "site_grid": 4.08,
      "operations": 7.7,
      "total": 55.49,
      "electricity_usd_2026_kwh": 0.2277,
      "wacc": 0.07,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.73,
      "electricity": 7.41,
      "site_grid": 3.9,
      "operations": 15.1,
      "total": 74.14,
      "electricity_usd_2026_kwh": 0.2277,
      "wacc": 0.07,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.92,
      "electricity": 13.63,
      "site_grid": 9.02,
      "operations": 18.32,
      "total": 124.89,
      "electricity_usd_2026_kwh": 0.2277,
      "wacc": 0.07,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.59,
      "electricity": 17.45,
      "site_grid": 8.64,
      "operations": 36.09,
      "total": 167.77,
      "electricity_usd_2026_kwh": 0.2277,
      "wacc": 0.07,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.41,
      "electricity": 1.97,
      "site_grid": 1.48,
      "operations": 3.31,
      "total": 24.17,
      "electricity_usd_2026_kwh": 0.2121,
      "wacc": 0.0608,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.9,
      "electricity": 2.52,
      "site_grid": 1.49,
      "operations": 6.48,
      "total": 32.39,
      "electricity_usd_2026_kwh": 0.2121,
      "wacc": 0.0608,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.3,
      "electricity": 5.34,
      "site_grid": 3.17,
      "operations": 7.69,
      "total": 53.49,
      "electricity_usd_2026_kwh": 0.2121,
      "wacc": 0.0608,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.93,
      "electricity": 6.84,
      "site_grid": 3.19,
      "operations": 15.1,
      "total": 72.06,
      "electricity_usd_2026_kwh": 0.2121,
      "wacc": 0.0608,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.51,
      "electricity": 12.58,
      "site_grid": 7.01,
      "operations": 18.29,
      "total": 120.39,
      "electricity_usd_2026_kwh": 0.2121,
      "wacc": 0.0608,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.83,
      "electricity": 16.11,
      "site_grid": 7.05,
      "operations": 36.09,
      "total": 163.08,
      "electricity_usd_2026_kwh": 0.2121,
      "wacc": 0.0608,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.27,
      "electricity": 2.13,
      "site_grid": 1.42,
      "operations": 3.31,
      "total": 24.13,
      "electricity_usd_2026_kwh": 0.2296,
      "wacc": 0.0565,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.73,
      "electricity": 2.73,
      "site_grid": 1.43,
      "operations": 6.48,
      "total": 32.37,
      "electricity_usd_2026_kwh": 0.2296,
      "wacc": 0.0565,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.0,
      "electricity": 5.78,
      "site_grid": 3.04,
      "operations": 7.69,
      "total": 53.5,
      "electricity_usd_2026_kwh": 0.2296,
      "wacc": 0.0565,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.56,
      "electricity": 7.41,
      "site_grid": 3.07,
      "operations": 15.1,
      "total": 72.13,
      "electricity_usd_2026_kwh": 0.2296,
      "wacc": 0.0565,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.85,
      "electricity": 13.62,
      "site_grid": 6.72,
      "operations": 18.29,
      "total": 120.47,
      "electricity_usd_2026_kwh": 0.2296,
      "wacc": 0.0565,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.0,
      "electricity": 17.44,
      "site_grid": 6.79,
      "operations": 36.09,
      "total": 163.32,
      "electricity_usd_2026_kwh": 0.2296,
      "wacc": 0.0565,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.95,
      "electricity": 1.88,
      "site_grid": 1.33,
      "operations": 3.31,
      "total": 23.47,
      "electricity_usd_2026_kwh": 0.2019,
      "wacc": 0.0467,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.33,
      "electricity": 2.4,
      "site_grid": 1.36,
      "operations": 6.48,
      "total": 31.58,
      "electricity_usd_2026_kwh": 0.2019,
      "wacc": 0.0467,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.32,
      "electricity": 5.08,
      "site_grid": 2.85,
      "operations": 7.69,
      "total": 51.94,
      "electricity_usd_2026_kwh": 0.2019,
      "wacc": 0.0467,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.71,
      "electricity": 6.51,
      "site_grid": 2.92,
      "operations": 15.1,
      "total": 70.24,
      "electricity_usd_2026_kwh": 0.2019,
      "wacc": 0.0467,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.35,
      "electricity": 11.97,
      "site_grid": 6.31,
      "operations": 18.29,
      "total": 116.93,
      "electricity_usd_2026_kwh": 0.2019,
      "wacc": 0.0467,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.13,
      "electricity": 15.34,
      "site_grid": 6.46,
      "operations": 36.09,
      "total": 159.02,
      "electricity_usd_2026_kwh": 0.2019,
      "wacc": 0.0467,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.13,
      "electricity": 1.9,
      "site_grid": 1.39,
      "operations": 3.31,
      "total": 23.74,
      "electricity_usd_2026_kwh": 0.2051,
      "wacc": 0.0522,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.55,
      "electricity": 2.44,
      "site_grid": 1.42,
      "operations": 6.48,
      "total": 31.89,
      "electricity_usd_2026_kwh": 0.2051,
      "wacc": 0.0522,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.7,
      "electricity": 5.16,
      "site_grid": 2.99,
      "operations": 7.69,
      "total": 52.53,
      "electricity_usd_2026_kwh": 0.2051,
      "wacc": 0.0522,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.18,
      "electricity": 6.62,
      "site_grid": 3.04,
      "operations": 15.1,
      "total": 70.93,
      "electricity_usd_2026_kwh": 0.2051,
      "wacc": 0.0522,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.19,
      "electricity": 12.16,
      "site_grid": 6.61,
      "operations": 18.29,
      "total": 118.25,
      "electricity_usd_2026_kwh": 0.2051,
      "wacc": 0.0522,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.17,
      "electricity": 15.58,
      "site_grid": 6.72,
      "operations": 36.09,
      "total": 160.56,
      "electricity_usd_2026_kwh": 0.2051,
      "wacc": 0.0522,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.19,
      "electricity": 1.88,
      "site_grid": 1.44,
      "operations": 3.31,
      "total": 23.82,
      "electricity_usd_2026_kwh": 0.2023,
      "wacc": 0.0541,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.63,
      "electricity": 2.41,
      "site_grid": 1.46,
      "operations": 6.48,
      "total": 31.97,
      "electricity_usd_2026_kwh": 0.2023,
      "wacc": 0.0541,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.83,
      "electricity": 5.09,
      "site_grid": 3.08,
      "operations": 7.69,
      "total": 52.68,
      "electricity_usd_2026_kwh": 0.2023,
      "wacc": 0.0541,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.35,
      "electricity": 6.52,
      "site_grid": 3.12,
      "operations": 15.1,
      "total": 71.09,
      "electricity_usd_2026_kwh": 0.2023,
      "wacc": 0.0541,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.48,
      "electricity": 11.99,
      "site_grid": 6.8,
      "operations": 18.29,
      "total": 118.57,
      "electricity_usd_2026_kwh": 0.2023,
      "wacc": 0.0541,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.53,
      "electricity": 15.37,
      "site_grid": 6.9,
      "operations": 36.09,
      "total": 160.89,
      "electricity_usd_2026_kwh": 0.2023,
      "wacc": 0.0541,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.06,
      "electricity": 1.57,
      "site_grid": 1.42,
      "operations": 3.31,
      "total": 23.36,
      "electricity_usd_2026_kwh": 0.1688,
      "wacc": 0.0501,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.47,
      "electricity": 2.01,
      "site_grid": 1.45,
      "operations": 6.48,
      "total": 31.41,
      "electricity_usd_2026_kwh": 0.1688,
      "wacc": 0.0501,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.55,
      "electricity": 4.25,
      "site_grid": 3.04,
      "operations": 7.69,
      "total": 51.53,
      "electricity_usd_2026_kwh": 0.1688,
      "wacc": 0.0501,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.0,
      "electricity": 5.45,
      "site_grid": 3.1,
      "operations": 15.1,
      "total": 69.65,
      "electricity_usd_2026_kwh": 0.1688,
      "wacc": 0.0501,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.86,
      "electricity": 10.01,
      "site_grid": 6.74,
      "operations": 18.29,
      "total": 115.9,
      "electricity_usd_2026_kwh": 0.1688,
      "wacc": 0.0501,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.77,
      "electricity": 12.82,
      "site_grid": 6.87,
      "operations": 36.09,
      "total": 157.55,
      "electricity_usd_2026_kwh": 0.1688,
      "wacc": 0.0501,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.96,
      "electricity": 1.61,
      "site_grid": 1.38,
      "operations": 3.31,
      "total": 23.27,
      "electricity_usd_2026_kwh": 0.1733,
      "wacc": 0.0471,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.35,
      "electricity": 2.06,
      "site_grid": 1.42,
      "operations": 6.48,
      "total": 31.3,
      "electricity_usd_2026_kwh": 0.1733,
      "wacc": 0.0471,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.34,
      "electricity": 4.36,
      "site_grid": 2.96,
      "operations": 7.69,
      "total": 51.35,
      "electricity_usd_2026_kwh": 0.1733,
      "wacc": 0.0471,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.74,
      "electricity": 5.59,
      "site_grid": 3.03,
      "operations": 15.1,
      "total": 69.46,
      "electricity_usd_2026_kwh": 0.1733,
      "wacc": 0.0471,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.4,
      "electricity": 10.27,
      "site_grid": 6.55,
      "operations": 18.29,
      "total": 115.52,
      "electricity_usd_2026_kwh": 0.1733,
      "wacc": 0.0471,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.19,
      "electricity": 13.16,
      "site_grid": 6.71,
      "operations": 36.09,
      "total": 157.15,
      "electricity_usd_2026_kwh": 0.1733,
      "wacc": 0.0471,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.12,
      "electricity": 1.55,
      "site_grid": 1.44,
      "operations": 3.31,
      "total": 23.42,
      "electricity_usd_2026_kwh": 0.1669,
      "wacc": 0.052,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.55,
      "electricity": 1.99,
      "site_grid": 1.46,
      "operations": 6.48,
      "total": 31.47,
      "electricity_usd_2026_kwh": 0.1669,
      "wacc": 0.052,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.68,
      "electricity": 4.2,
      "site_grid": 3.08,
      "operations": 7.69,
      "total": 51.65,
      "electricity_usd_2026_kwh": 0.1669,
      "wacc": 0.052,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.16,
      "electricity": 5.38,
      "site_grid": 3.13,
      "operations": 15.1,
      "total": 69.78,
      "electricity_usd_2026_kwh": 0.1669,
      "wacc": 0.052,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.15,
      "electricity": 9.9,
      "site_grid": 6.81,
      "operations": 18.29,
      "total": 116.15,
      "electricity_usd_2026_kwh": 0.1669,
      "wacc": 0.052,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.13,
      "electricity": 12.68,
      "site_grid": 6.92,
      "operations": 36.09,
      "total": 157.83,
      "electricity_usd_2026_kwh": 0.1669,
      "wacc": 0.052,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.31,
      "electricity": 1.61,
      "site_grid": 1.53,
      "operations": 3.31,
      "total": 23.77,
      "electricity_usd_2026_kwh": 0.1739,
      "wacc": 0.0578,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.78,
      "electricity": 2.07,
      "site_grid": 1.54,
      "operations": 6.48,
      "total": 31.87,
      "electricity_usd_2026_kwh": 0.1739,
      "wacc": 0.0578,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.08,
      "electricity": 4.38,
      "site_grid": 3.27,
      "operations": 7.69,
      "total": 52.42,
      "electricity_usd_2026_kwh": 0.1739,
      "wacc": 0.0578,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.67,
      "electricity": 5.61,
      "site_grid": 3.31,
      "operations": 15.1,
      "total": 70.68,
      "electricity_usd_2026_kwh": 0.1739,
      "wacc": 0.0578,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.04,
      "electricity": 10.31,
      "site_grid": 7.25,
      "operations": 18.29,
      "total": 117.89,
      "electricity_usd_2026_kwh": 0.1739,
      "wacc": 0.0578,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.24,
      "electricity": 13.21,
      "site_grid": 7.31,
      "operations": 36.09,
      "total": 159.86,
      "electricity_usd_2026_kwh": 0.1739,
      "wacc": 0.0578,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.06,
      "electricity": 1.55,
      "site_grid": 1.51,
      "operations": 3.31,
      "total": 23.43,
      "electricity_usd_2026_kwh": 0.1667,
      "wacc": 0.0501,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.47,
      "electricity": 1.98,
      "site_grid": 1.54,
      "operations": 6.48,
      "total": 31.47,
      "electricity_usd_2026_kwh": 0.1667,
      "wacc": 0.0501,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.55,
      "electricity": 4.2,
      "site_grid": 3.23,
      "operations": 7.69,
      "total": 51.67,
      "electricity_usd_2026_kwh": 0.1667,
      "wacc": 0.0501,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.0,
      "electricity": 5.38,
      "site_grid": 3.29,
      "operations": 15.1,
      "total": 69.77,
      "electricity_usd_2026_kwh": 0.1667,
      "wacc": 0.0501,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.87,
      "electricity": 9.88,
      "site_grid": 7.15,
      "operations": 18.29,
      "total": 116.19,
      "electricity_usd_2026_kwh": 0.1667,
      "wacc": 0.0501,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.77,
      "electricity": 12.66,
      "site_grid": 7.29,
      "operations": 36.09,
      "total": 157.81,
      "electricity_usd_2026_kwh": 0.1667,
      "wacc": 0.0501,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.74,
      "electricity": 1.6,
      "site_grid": 1.43,
      "operations": 3.31,
      "total": 23.07,
      "electricity_usd_2026_kwh": 0.1718,
      "wacc": 0.0376,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.97,
      "electricity": 2.04,
      "site_grid": 1.46,
      "operations": 6.48,
      "total": 30.95,
      "electricity_usd_2026_kwh": 0.1718,
      "wacc": 0.0376,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.86,
      "electricity": 4.33,
      "site_grid": 3.06,
      "operations": 7.69,
      "total": 50.93,
      "electricity_usd_2026_kwh": 0.1718,
      "wacc": 0.0376,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.93,
      "electricity": 5.54,
      "site_grid": 3.12,
      "operations": 15.1,
      "total": 68.68,
      "electricity_usd_2026_kwh": 0.1718,
      "wacc": 0.0376,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.33,
      "electricity": 10.19,
      "site_grid": 6.77,
      "operations": 18.29,
      "total": 114.58,
      "electricity_usd_2026_kwh": 0.1718,
      "wacc": 0.0376,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.39,
      "electricity": 13.05,
      "site_grid": 6.9,
      "operations": 36.09,
      "total": 155.43,
      "electricity_usd_2026_kwh": 0.1718,
      "wacc": 0.0376,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.84,
      "electricity": 1.78,
      "site_grid": 1.47,
      "operations": 3.31,
      "total": 23.4,
      "electricity_usd_2026_kwh": 0.1917,
      "wacc": 0.0432,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.19,
      "electricity": 2.28,
      "site_grid": 1.51,
      "operations": 6.48,
      "total": 31.46,
      "electricity_usd_2026_kwh": 0.1917,
      "wacc": 0.0432,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.08,
      "electricity": 4.83,
      "site_grid": 3.14,
      "operations": 7.69,
      "total": 51.73,
      "electricity_usd_2026_kwh": 0.1917,
      "wacc": 0.0432,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.4,
      "electricity": 6.18,
      "site_grid": 3.24,
      "operations": 15.1,
      "total": 69.92,
      "electricity_usd_2026_kwh": 0.1917,
      "wacc": 0.0432,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.81,
      "electricity": 11.37,
      "site_grid": 6.96,
      "operations": 18.29,
      "total": 116.43,
      "electricity_usd_2026_kwh": 0.1917,
      "wacc": 0.0432,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.45,
      "electricity": 14.56,
      "site_grid": 7.16,
      "operations": 36.09,
      "total": 158.27,
      "electricity_usd_2026_kwh": 0.1917,
      "wacc": 0.0432,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.32,
      "electricity": 2.38,
      "site_grid": 1.85,
      "operations": 3.31,
      "total": 24.86,
      "electricity_usd_2026_kwh": 0.2563,
      "wacc": 0.0582,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.8,
      "electricity": 3.05,
      "site_grid": 1.86,
      "operations": 6.48,
      "total": 33.19,
      "electricity_usd_2026_kwh": 0.2563,
      "wacc": 0.0582,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.11,
      "electricity": 6.45,
      "site_grid": 3.95,
      "operations": 7.69,
      "total": 55.21,
      "electricity_usd_2026_kwh": 0.2563,
      "wacc": 0.0582,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.7,
      "electricity": 8.27,
      "site_grid": 3.99,
      "operations": 15.1,
      "total": 74.06,
      "electricity_usd_2026_kwh": 0.2563,
      "wacc": 0.0582,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.11,
      "electricity": 15.2,
      "site_grid": 8.75,
      "operations": 18.29,
      "total": 124.35,
      "electricity_usd_2026_kwh": 0.2563,
      "wacc": 0.0582,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.32,
      "electricity": 19.47,
      "site_grid": 8.83,
      "operations": 36.09,
      "total": 167.71,
      "electricity_usd_2026_kwh": 0.2563,
      "wacc": 0.0582,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.65,
      "electricity": 2.42,
      "site_grid": 2.04,
      "operations": 3.31,
      "total": 25.42,
      "electricity_usd_2026_kwh": 0.2602,
      "wacc": 0.0683,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.21,
      "electricity": 3.1,
      "site_grid": 2.03,
      "operations": 6.48,
      "total": 33.81,
      "electricity_usd_2026_kwh": 0.2602,
      "wacc": 0.0683,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.81,
      "electricity": 6.55,
      "site_grid": 4.37,
      "operations": 7.69,
      "total": 56.42,
      "electricity_usd_2026_kwh": 0.2602,
      "wacc": 0.0683,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.58,
      "electricity": 8.39,
      "site_grid": 4.35,
      "operations": 15.1,
      "total": 75.42,
      "electricity_usd_2026_kwh": 0.2602,
      "wacc": 0.0683,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.65,
      "electricity": 15.43,
      "site_grid": 9.67,
      "operations": 18.29,
      "total": 127.04,
      "electricity_usd_2026_kwh": 0.2602,
      "wacc": 0.0683,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.26,
      "electricity": 19.76,
      "site_grid": 9.63,
      "operations": 36.09,
      "total": 170.74,
      "electricity_usd_2026_kwh": 0.2602,
      "wacc": 0.0683,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.73,
      "electricity": 1.9,
      "site_grid": 2.01,
      "operations": 3.31,
      "total": 24.95,
      "electricity_usd_2026_kwh": 0.2049,
      "wacc": 0.0708,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.31,
      "electricity": 2.44,
      "site_grid": 1.99,
      "operations": 6.48,
      "total": 33.22,
      "electricity_usd_2026_kwh": 0.2049,
      "wacc": 0.0708,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.99,
      "electricity": 5.16,
      "site_grid": 4.3,
      "operations": 7.69,
      "total": 55.13,
      "electricity_usd_2026_kwh": 0.2049,
      "wacc": 0.0708,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.79,
      "electricity": 6.61,
      "site_grid": 4.27,
      "operations": 15.1,
      "total": 73.77,
      "electricity_usd_2026_kwh": 0.2049,
      "wacc": 0.0708,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.04,
      "electricity": 12.15,
      "site_grid": 9.51,
      "operations": 18.29,
      "total": 124.0,
      "electricity_usd_2026_kwh": 0.2049,
      "wacc": 0.0708,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.74,
      "electricity": 15.57,
      "site_grid": 9.45,
      "operations": 36.09,
      "total": 166.84,
      "electricity_usd_2026_kwh": 0.2049,
      "wacc": 0.0708,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.76,
      "electricity": 2.05,
      "site_grid": 1.99,
      "operations": 3.31,
      "total": 25.11,
      "electricity_usd_2026_kwh": 0.2208,
      "wacc": 0.0716,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.34,
      "electricity": 2.63,
      "site_grid": 1.98,
      "operations": 6.48,
      "total": 33.42,
      "electricity_usd_2026_kwh": 0.2208,
      "wacc": 0.0716,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.05,
      "electricity": 5.56,
      "site_grid": 4.27,
      "operations": 7.69,
      "total": 55.56,
      "electricity_usd_2026_kwh": 0.2208,
      "wacc": 0.0716,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.87,
      "electricity": 7.12,
      "site_grid": 4.24,
      "operations": 15.1,
      "total": 74.32,
      "electricity_usd_2026_kwh": 0.2208,
      "wacc": 0.0716,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.17,
      "electricity": 13.09,
      "site_grid": 9.44,
      "operations": 18.29,
      "total": 125.0,
      "electricity_usd_2026_kwh": 0.2208,
      "wacc": 0.0716,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.9,
      "electricity": 16.77,
      "site_grid": 9.37,
      "operations": 36.09,
      "total": 168.13,
      "electricity_usd_2026_kwh": 0.2208,
      "wacc": 0.0716,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.77,
      "electricity": 1.99,
      "site_grid": 2.0,
      "operations": 3.31,
      "total": 25.07,
      "electricity_usd_2026_kwh": 0.214,
      "wacc": 0.072,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.36,
      "electricity": 2.55,
      "site_grid": 1.99,
      "operations": 6.48,
      "total": 33.37,
      "electricity_usd_2026_kwh": 0.214,
      "wacc": 0.072,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.07,
      "electricity": 5.39,
      "site_grid": 4.29,
      "operations": 7.69,
      "total": 55.43,
      "electricity_usd_2026_kwh": 0.214,
      "wacc": 0.072,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.9,
      "electricity": 6.9,
      "site_grid": 4.26,
      "operations": 15.1,
      "total": 74.16,
      "electricity_usd_2026_kwh": 0.214,
      "wacc": 0.072,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.23,
      "electricity": 12.69,
      "site_grid": 9.49,
      "operations": 18.29,
      "total": 124.7,
      "electricity_usd_2026_kwh": 0.214,
      "wacc": 0.072,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.98,
      "electricity": 16.25,
      "site_grid": 9.41,
      "operations": 36.09,
      "total": 167.73,
      "electricity_usd_2026_kwh": 0.214,
      "wacc": 0.072,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.08,
      "electricity": 1.28,
      "site_grid": 1.41,
      "operations": 3.26,
      "total": 25.04,
      "electricity_usd_2026_kwh": 0.1319,
      "wacc": 0.0838,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.1,
      "electricity": 1.65,
      "site_grid": 1.21,
      "operations": 5.45,
      "total": 32.41,
      "electricity_usd_2026_kwh": 0.1319,
      "wacc": 0.0838,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.89,
      "electricity": 3.48,
      "site_grid": 3.02,
      "operations": 7.57,
      "total": 54.96,
      "electricity_usd_2026_kwh": 0.1319,
      "wacc": 0.0838,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.63,
      "electricity": 4.47,
      "site_grid": 2.6,
      "operations": 12.89,
      "total": 71.59,
      "electricity_usd_2026_kwh": 0.1319,
      "wacc": 0.0838,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.46,
      "electricity": 8.2,
      "site_grid": 6.67,
      "operations": 18.04,
      "total": 123.37,
      "electricity_usd_2026_kwh": 0.1319,
      "wacc": 0.0838,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 114.21,
      "electricity": 10.53,
      "site_grid": 5.75,
      "operations": 31.23,
      "total": 161.74,
      "electricity_usd_2026_kwh": 0.1319,
      "wacc": 0.0838,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.93,
      "electricity": 1.31,
      "site_grid": 1.35,
      "operations": 3.26,
      "total": 24.86,
      "electricity_usd_2026_kwh": 0.1345,
      "wacc": 0.0795,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.91,
      "electricity": 1.68,
      "site_grid": 1.17,
      "operations": 5.45,
      "total": 32.21,
      "electricity_usd_2026_kwh": 0.1345,
      "wacc": 0.0795,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.57,
      "electricity": 3.55,
      "site_grid": 2.9,
      "operations": 7.57,
      "total": 54.58,
      "electricity_usd_2026_kwh": 0.1345,
      "wacc": 0.0795,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.22,
      "electricity": 4.56,
      "site_grid": 2.51,
      "operations": 12.89,
      "total": 71.19,
      "electricity_usd_2026_kwh": 0.1345,
      "wacc": 0.0795,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.75,
      "electricity": 8.36,
      "site_grid": 6.41,
      "operations": 18.04,
      "total": 122.56,
      "electricity_usd_2026_kwh": 0.1345,
      "wacc": 0.0795,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 113.33,
      "electricity": 10.74,
      "site_grid": 5.55,
      "operations": 31.23,
      "total": 160.85,
      "electricity_usd_2026_kwh": 0.1345,
      "wacc": 0.0795,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.6,
      "electricity": 1.32,
      "site_grid": 1.28,
      "operations": 3.26,
      "total": 24.46,
      "electricity_usd_2026_kwh": 0.136,
      "wacc": 0.0697,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.49,
      "electricity": 1.7,
      "site_grid": 1.12,
      "operations": 5.45,
      "total": 31.75,
      "electricity_usd_2026_kwh": 0.136,
      "wacc": 0.0697,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.85,
      "electricity": 3.59,
      "site_grid": 2.73,
      "operations": 7.57,
      "total": 53.74,
      "electricity_usd_2026_kwh": 0.136,
      "wacc": 0.0697,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.32,
      "electricity": 4.61,
      "site_grid": 2.4,
      "operations": 12.89,
      "total": 70.22,
      "electricity_usd_2026_kwh": 0.136,
      "wacc": 0.0697,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.16,
      "electricity": 8.45,
      "site_grid": 6.05,
      "operations": 18.04,
      "total": 120.7,
      "electricity_usd_2026_kwh": 0.136,
      "wacc": 0.0697,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.33,
      "electricity": 10.86,
      "site_grid": 5.3,
      "operations": 31.23,
      "total": 158.72,
      "electricity_usd_2026_kwh": 0.136,
      "wacc": 0.0697,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.79,
      "electricity": 1.41,
      "site_grid": 1.33,
      "operations": 3.26,
      "total": 24.79,
      "electricity_usd_2026_kwh": 0.145,
      "wacc": 0.0752,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.72,
      "electricity": 1.81,
      "site_grid": 1.16,
      "operations": 5.45,
      "total": 32.14,
      "electricity_usd_2026_kwh": 0.145,
      "wacc": 0.0752,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.25,
      "electricity": 3.83,
      "site_grid": 2.86,
      "operations": 7.57,
      "total": 54.5,
      "electricity_usd_2026_kwh": 0.145,
      "wacc": 0.0752,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.83,
      "electricity": 4.92,
      "site_grid": 2.49,
      "operations": 12.89,
      "total": 71.12,
      "electricity_usd_2026_kwh": 0.145,
      "wacc": 0.0752,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.05,
      "electricity": 9.01,
      "site_grid": 6.32,
      "operations": 18.04,
      "total": 122.42,
      "electricity_usd_2026_kwh": 0.145,
      "wacc": 0.0752,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.44,
      "electricity": 11.58,
      "site_grid": 5.5,
      "operations": 31.23,
      "total": 160.76,
      "electricity_usd_2026_kwh": 0.145,
      "wacc": 0.0752,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.85,
      "electricity": 1.36,
      "site_grid": 1.37,
      "operations": 3.26,
      "total": 24.84,
      "electricity_usd_2026_kwh": 0.1395,
      "wacc": 0.0771,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.8,
      "electricity": 1.74,
      "site_grid": 1.19,
      "operations": 5.45,
      "total": 32.19,
      "electricity_usd_2026_kwh": 0.1395,
      "wacc": 0.0771,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.39,
      "electricity": 3.68,
      "site_grid": 2.94,
      "operations": 7.57,
      "total": 54.58,
      "electricity_usd_2026_kwh": 0.1395,
      "wacc": 0.0771,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.0,
      "electricity": 4.73,
      "site_grid": 2.55,
      "operations": 12.89,
      "total": 71.17,
      "electricity_usd_2026_kwh": 0.1395,
      "wacc": 0.0771,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.36,
      "electricity": 8.67,
      "site_grid": 6.5,
      "operations": 18.04,
      "total": 122.56,
      "electricity_usd_2026_kwh": 0.1395,
      "wacc": 0.0771,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.83,
      "electricity": 11.13,
      "site_grid": 5.64,
      "operations": 31.23,
      "total": 160.85,
      "electricity_usd_2026_kwh": 0.1395,
      "wacc": 0.0771,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.71,
      "electricity": 1.11,
      "site_grid": 1.36,
      "operations": 3.26,
      "total": 24.44,
      "electricity_usd_2026_kwh": 0.1141,
      "wacc": 0.0731,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.63,
      "electricity": 1.43,
      "site_grid": 1.19,
      "operations": 5.45,
      "total": 31.69,
      "electricity_usd_2026_kwh": 0.1141,
      "wacc": 0.0731,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.09,
      "electricity": 3.01,
      "site_grid": 2.91,
      "operations": 7.57,
      "total": 53.59,
      "electricity_usd_2026_kwh": 0.1141,
      "wacc": 0.0731,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.63,
      "electricity": 3.87,
      "site_grid": 2.54,
      "operations": 12.89,
      "total": 69.94,
      "electricity_usd_2026_kwh": 0.1141,
      "wacc": 0.0731,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.7,
      "electricity": 7.09,
      "site_grid": 6.45,
      "operations": 18.04,
      "total": 120.28,
      "electricity_usd_2026_kwh": 0.1141,
      "wacc": 0.0731,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.01,
      "electricity": 9.11,
      "site_grid": 5.63,
      "operations": 31.23,
      "total": 157.98,
      "electricity_usd_2026_kwh": 0.1141,
      "wacc": 0.0731,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.61,
      "electricity": 1.33,
      "site_grid": 1.33,
      "operations": 3.26,
      "total": 24.52,
      "electricity_usd_2026_kwh": 0.1365,
      "wacc": 0.0701,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.5,
      "electricity": 1.71,
      "site_grid": 1.16,
      "operations": 5.45,
      "total": 31.82,
      "electricity_usd_2026_kwh": 0.1365,
      "wacc": 0.0701,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.87,
      "electricity": 3.6,
      "site_grid": 2.84,
      "operations": 7.57,
      "total": 53.88,
      "electricity_usd_2026_kwh": 0.1365,
      "wacc": 0.0701,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.35,
      "electricity": 4.63,
      "site_grid": 2.49,
      "operations": 12.89,
      "total": 70.36,
      "electricity_usd_2026_kwh": 0.1365,
      "wacc": 0.0701,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.22,
      "electricity": 8.48,
      "site_grid": 6.28,
      "operations": 18.04,
      "total": 121.02,
      "electricity_usd_2026_kwh": 0.1365,
      "wacc": 0.0701,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.4,
      "electricity": 10.89,
      "site_grid": 5.5,
      "operations": 31.23,
      "total": 159.03,
      "electricity_usd_2026_kwh": 0.1365,
      "wacc": 0.0701,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.78,
      "electricity": 1.15,
      "site_grid": 1.37,
      "operations": 3.26,
      "total": 24.56,
      "electricity_usd_2026_kwh": 0.1183,
      "wacc": 0.075,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.71,
      "electricity": 1.48,
      "site_grid": 1.2,
      "operations": 5.45,
      "total": 31.84,
      "electricity_usd_2026_kwh": 0.1183,
      "wacc": 0.075,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.24,
      "electricity": 3.12,
      "site_grid": 2.94,
      "operations": 7.57,
      "total": 53.87,
      "electricity_usd_2026_kwh": 0.1183,
      "wacc": 0.075,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.81,
      "electricity": 4.01,
      "site_grid": 2.56,
      "operations": 12.89,
      "total": 70.27,
      "electricity_usd_2026_kwh": 0.1183,
      "wacc": 0.075,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.01,
      "electricity": 7.36,
      "site_grid": 6.51,
      "operations": 18.04,
      "total": 120.92,
      "electricity_usd_2026_kwh": 0.1183,
      "wacc": 0.075,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.4,
      "electricity": 9.45,
      "site_grid": 5.67,
      "operations": 31.23,
      "total": 158.75,
      "electricity_usd_2026_kwh": 0.1183,
      "wacc": 0.075,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.98,
      "electricity": 1.25,
      "site_grid": 1.46,
      "operations": 3.26,
      "total": 24.95,
      "electricity_usd_2026_kwh": 0.1287,
      "wacc": 0.0808,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.96,
      "electricity": 1.61,
      "site_grid": 1.26,
      "operations": 5.45,
      "total": 32.28,
      "electricity_usd_2026_kwh": 0.1287,
      "wacc": 0.0808,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.66,
      "electricity": 3.4,
      "site_grid": 3.12,
      "operations": 7.57,
      "total": 54.75,
      "electricity_usd_2026_kwh": 0.1287,
      "wacc": 0.0808,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.34,
      "electricity": 4.36,
      "site_grid": 2.7,
      "operations": 12.89,
      "total": 71.3,
      "electricity_usd_2026_kwh": 0.1287,
      "wacc": 0.0808,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.96,
      "electricity": 8.0,
      "site_grid": 6.9,
      "operations": 18.04,
      "total": 122.91,
      "electricity_usd_2026_kwh": 0.1287,
      "wacc": 0.0808,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 113.59,
      "electricity": 10.28,
      "site_grid": 5.97,
      "operations": 31.23,
      "total": 161.08,
      "electricity_usd_2026_kwh": 0.1287,
      "wacc": 0.0808,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.71,
      "electricity": 1.24,
      "site_grid": 1.44,
      "operations": 3.26,
      "total": 24.66,
      "electricity_usd_2026_kwh": 0.1271,
      "wacc": 0.0731,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.63,
      "electricity": 1.59,
      "site_grid": 1.26,
      "operations": 5.45,
      "total": 31.93,
      "electricity_usd_2026_kwh": 0.1271,
      "wacc": 0.0731,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.1,
      "electricity": 3.35,
      "site_grid": 3.09,
      "operations": 7.57,
      "total": 54.11,
      "electricity_usd_2026_kwh": 0.1271,
      "wacc": 0.0731,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.63,
      "electricity": 4.31,
      "site_grid": 2.7,
      "operations": 12.89,
      "total": 70.53,
      "electricity_usd_2026_kwh": 0.1271,
      "wacc": 0.0731,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.71,
      "electricity": 7.9,
      "site_grid": 6.84,
      "operations": 18.04,
      "total": 121.49,
      "electricity_usd_2026_kwh": 0.1271,
      "wacc": 0.0731,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.02,
      "electricity": 10.14,
      "site_grid": 5.97,
      "operations": 31.23,
      "total": 159.37,
      "electricity_usd_2026_kwh": 0.1271,
      "wacc": 0.0731,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.29,
      "electricity": 1.18,
      "site_grid": 1.35,
      "operations": 3.26,
      "total": 24.08,
      "electricity_usd_2026_kwh": 0.121,
      "wacc": 0.0606,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.1,
      "electricity": 1.51,
      "site_grid": 1.2,
      "operations": 5.45,
      "total": 31.25,
      "electricity_usd_2026_kwh": 0.121,
      "wacc": 0.0606,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.18,
      "electricity": 3.19,
      "site_grid": 2.9,
      "operations": 7.57,
      "total": 52.84,
      "electricity_usd_2026_kwh": 0.121,
      "wacc": 0.0606,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.48,
      "electricity": 4.1,
      "site_grid": 2.57,
      "operations": 12.89,
      "total": 69.05,
      "electricity_usd_2026_kwh": 0.121,
      "wacc": 0.0606,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.68,
      "electricity": 7.52,
      "site_grid": 6.41,
      "operations": 18.04,
      "total": 118.65,
      "electricity_usd_2026_kwh": 0.121,
      "wacc": 0.0606,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.48,
      "electricity": 9.66,
      "site_grid": 5.68,
      "operations": 31.23,
      "total": 156.04,
      "electricity_usd_2026_kwh": 0.121,
      "wacc": 0.0606,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.48,
      "electricity": 1.77,
      "site_grid": 1.41,
      "operations": 3.26,
      "total": 24.92,
      "electricity_usd_2026_kwh": 0.1823,
      "wacc": 0.0662,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.33,
      "electricity": 2.28,
      "site_grid": 1.24,
      "operations": 5.45,
      "total": 32.3,
      "electricity_usd_2026_kwh": 0.1823,
      "wacc": 0.0662,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.59,
      "electricity": 4.81,
      "site_grid": 3.02,
      "operations": 7.57,
      "total": 54.99,
      "electricity_usd_2026_kwh": 0.1823,
      "wacc": 0.0662,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.99,
      "electricity": 6.18,
      "site_grid": 2.66,
      "operations": 12.89,
      "total": 71.73,
      "electricity_usd_2026_kwh": 0.1823,
      "wacc": 0.0662,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.58,
      "electricity": 11.33,
      "site_grid": 6.68,
      "operations": 18.04,
      "total": 123.64,
      "electricity_usd_2026_kwh": 0.1823,
      "wacc": 0.0662,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.61,
      "electricity": 14.55,
      "site_grid": 5.88,
      "operations": 31.23,
      "total": 162.27,
      "electricity_usd_2026_kwh": 0.1823,
      "wacc": 0.0662,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.99,
      "electricity": 2.04,
      "site_grid": 1.76,
      "operations": 3.26,
      "total": 26.06,
      "electricity_usd_2026_kwh": 0.2099,
      "wacc": 0.0812,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.98,
      "electricity": 2.63,
      "site_grid": 1.52,
      "operations": 5.45,
      "total": 33.58,
      "electricity_usd_2026_kwh": 0.2099,
      "wacc": 0.0812,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.69,
      "electricity": 5.54,
      "site_grid": 3.77,
      "operations": 7.57,
      "total": 57.57,
      "electricity_usd_2026_kwh": 0.2099,
      "wacc": 0.0812,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.38,
      "electricity": 7.12,
      "site_grid": 3.26,
      "operations": 12.89,
      "total": 74.65,
      "electricity_usd_2026_kwh": 0.2099,
      "wacc": 0.0812,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.03,
      "electricity": 13.05,
      "site_grid": 8.34,
      "operations": 18.04,
      "total": 129.45,
      "electricity_usd_2026_kwh": 0.2099,
      "wacc": 0.0812,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 113.67,
      "electricity": 16.76,
      "site_grid": 7.21,
      "operations": 31.23,
      "total": 168.88,
      "electricity_usd_2026_kwh": 0.2099,
      "wacc": 0.0812,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.34,
      "electricity": 1.63,
      "site_grid": 1.93,
      "operations": 3.26,
      "total": 26.17,
      "electricity_usd_2026_kwh": 0.1675,
      "wacc": 0.0913,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.42,
      "electricity": 2.09,
      "site_grid": 1.65,
      "operations": 5.45,
      "total": 33.61,
      "electricity_usd_2026_kwh": 0.1675,
      "wacc": 0.0913,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.44,
      "electricity": 4.42,
      "site_grid": 4.14,
      "operations": 7.57,
      "total": 57.57,
      "electricity_usd_2026_kwh": 0.1675,
      "wacc": 0.0913,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.32,
      "electricity": 5.68,
      "site_grid": 3.54,
      "operations": 12.89,
      "total": 74.43,
      "electricity_usd_2026_kwh": 0.1675,
      "wacc": 0.0913,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 91.68,
      "electricity": 10.41,
      "site_grid": 9.16,
      "operations": 18.04,
      "total": 129.29,
      "electricity_usd_2026_kwh": 0.1675,
      "wacc": 0.0913,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 115.74,
      "electricity": 13.37,
      "site_grid": 7.84,
      "operations": 31.23,
      "total": 168.19,
      "electricity_usd_2026_kwh": 0.1675,
      "wacc": 0.0913,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.43,
      "electricity": 1.36,
      "site_grid": 1.9,
      "operations": 3.26,
      "total": 25.95,
      "electricity_usd_2026_kwh": 0.1401,
      "wacc": 0.0938,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.53,
      "electricity": 1.75,
      "site_grid": 1.62,
      "operations": 5.45,
      "total": 33.35,
      "electricity_usd_2026_kwh": 0.1401,
      "wacc": 0.0938,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.62,
      "electricity": 3.7,
      "site_grid": 4.07,
      "operations": 7.57,
      "total": 56.96,
      "electricity_usd_2026_kwh": 0.1401,
      "wacc": 0.0938,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.55,
      "electricity": 4.75,
      "site_grid": 3.47,
      "operations": 12.89,
      "total": 73.67,
      "electricity_usd_2026_kwh": 0.1401,
      "wacc": 0.0938,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 92.09,
      "electricity": 8.71,
      "site_grid": 9.01,
      "operations": 18.04,
      "total": 127.84,
      "electricity_usd_2026_kwh": 0.1401,
      "wacc": 0.0938,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 116.26,
      "electricity": 11.19,
      "site_grid": 7.69,
      "operations": 31.23,
      "total": 166.36,
      "electricity_usd_2026_kwh": 0.1401,
      "wacc": 0.0938,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.46,
      "electricity": 1.52,
      "site_grid": 1.89,
      "operations": 3.26,
      "total": 26.12,
      "electricity_usd_2026_kwh": 0.1557,
      "wacc": 0.0946,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.56,
      "electricity": 1.95,
      "site_grid": 1.61,
      "operations": 5.45,
      "total": 33.57,
      "electricity_usd_2026_kwh": 0.1557,
      "wacc": 0.0946,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.69,
      "electricity": 4.11,
      "site_grid": 4.04,
      "operations": 7.57,
      "total": 57.4,
      "electricity_usd_2026_kwh": 0.1557,
      "wacc": 0.0946,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.63,
      "electricity": 5.28,
      "site_grid": 3.44,
      "operations": 12.89,
      "total": 74.24,
      "electricity_usd_2026_kwh": 0.1557,
      "wacc": 0.0946,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 92.23,
      "electricity": 9.68,
      "site_grid": 8.94,
      "operations": 18.04,
      "total": 128.88,
      "electricity_usd_2026_kwh": 0.1557,
      "wacc": 0.0946,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 116.43,
      "electricity": 12.43,
      "site_grid": 7.62,
      "operations": 31.23,
      "total": 167.72,
      "electricity_usd_2026_kwh": 0.1557,
      "wacc": 0.0946,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.47,
      "electricity": 1.58,
      "site_grid": 1.89,
      "operations": 3.26,
      "total": 26.2,
      "electricity_usd_2026_kwh": 0.162,
      "wacc": 0.095,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.58,
      "electricity": 2.03,
      "site_grid": 1.61,
      "operations": 5.45,
      "total": 33.67,
      "electricity_usd_2026_kwh": 0.162,
      "wacc": 0.095,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.72,
      "electricity": 4.28,
      "site_grid": 4.06,
      "operations": 7.57,
      "total": 57.62,
      "electricity_usd_2026_kwh": 0.162,
      "wacc": 0.095,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.66,
      "electricity": 5.49,
      "site_grid": 3.46,
      "operations": 12.89,
      "total": 74.51,
      "electricity_usd_2026_kwh": 0.162,
      "wacc": 0.095,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 92.29,
      "electricity": 10.07,
      "site_grid": 8.98,
      "operations": 18.04,
      "total": 129.38,
      "electricity_usd_2026_kwh": 0.162,
      "wacc": 0.095,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 116.51,
      "electricity": 12.94,
      "site_grid": 7.65,
      "operations": 31.23,
      "total": 168.33,
      "electricity_usd_2026_kwh": 0.162,
      "wacc": 0.095,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.9,
      "electricity": 1.82,
      "site_grid": 1.41,
      "operations": 3.31,
      "total": 25.45,
      "electricity_usd_2026_kwh": 0.1852,
      "wacc": 0.0788,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.86,
      "electricity": 2.33,
      "site_grid": 1.24,
      "operations": 5.73,
      "total": 33.16,
      "electricity_usd_2026_kwh": 0.1852,
      "wacc": 0.0788,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.5,
      "electricity": 4.93,
      "site_grid": 3.02,
      "operations": 7.68,
      "total": 56.14,
      "electricity_usd_2026_kwh": 0.1852,
      "wacc": 0.0788,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.11,
      "electricity": 6.33,
      "site_grid": 2.66,
      "operations": 13.49,
      "total": 73.59,
      "electricity_usd_2026_kwh": 0.1852,
      "wacc": 0.0788,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.61,
      "electricity": 11.61,
      "site_grid": 6.68,
      "operations": 18.29,
      "total": 126.19,
      "electricity_usd_2026_kwh": 0.1852,
      "wacc": 0.0788,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 113.08,
      "electricity": 14.9,
      "site_grid": 5.89,
      "operations": 32.55,
      "total": 166.41,
      "electricity_usd_2026_kwh": 0.1852,
      "wacc": 0.0788,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.76,
      "electricity": 1.81,
      "site_grid": 1.35,
      "operations": 3.31,
      "total": 25.23,
      "electricity_usd_2026_kwh": 0.1841,
      "wacc": 0.0745,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.67,
      "electricity": 2.32,
      "site_grid": 1.2,
      "operations": 5.73,
      "total": 32.91,
      "electricity_usd_2026_kwh": 0.1841,
      "wacc": 0.0745,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.18,
      "electricity": 4.9,
      "site_grid": 2.9,
      "operations": 7.68,
      "total": 55.67,
      "electricity_usd_2026_kwh": 0.1841,
      "wacc": 0.0745,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.71,
      "electricity": 6.29,
      "site_grid": 2.57,
      "operations": 13.49,
      "total": 73.06,
      "electricity_usd_2026_kwh": 0.1841,
      "wacc": 0.0745,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.9,
      "electricity": 11.54,
      "site_grid": 6.41,
      "operations": 18.29,
      "total": 125.15,
      "electricity_usd_2026_kwh": 0.1841,
      "wacc": 0.0745,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.19,
      "electricity": 14.81,
      "site_grid": 5.68,
      "operations": 32.55,
      "total": 165.23,
      "electricity_usd_2026_kwh": 0.1841,
      "wacc": 0.0745,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.42,
      "electricity": 1.67,
      "site_grid": 1.28,
      "operations": 3.31,
      "total": 24.68,
      "electricity_usd_2026_kwh": 0.1701,
      "wacc": 0.0647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.25,
      "electricity": 2.14,
      "site_grid": 1.14,
      "operations": 5.73,
      "total": 32.26,
      "electricity_usd_2026_kwh": 0.1701,
      "wacc": 0.0647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.47,
      "electricity": 4.53,
      "site_grid": 2.73,
      "operations": 7.68,
      "total": 54.41,
      "electricity_usd_2026_kwh": 0.1701,
      "wacc": 0.0647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.81,
      "electricity": 5.81,
      "site_grid": 2.45,
      "operations": 13.49,
      "total": 71.56,
      "electricity_usd_2026_kwh": 0.1701,
      "wacc": 0.0647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.32,
      "electricity": 10.66,
      "site_grid": 6.05,
      "operations": 18.29,
      "total": 122.32,
      "electricity_usd_2026_kwh": 0.1701,
      "wacc": 0.0647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.2,
      "electricity": 13.68,
      "site_grid": 5.42,
      "operations": 32.55,
      "total": 161.86,
      "electricity_usd_2026_kwh": 0.1701,
      "wacc": 0.0647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.61,
      "electricity": 1.75,
      "site_grid": 1.33,
      "operations": 3.31,
      "total": 25.01,
      "electricity_usd_2026_kwh": 0.1784,
      "wacc": 0.0702,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.48,
      "electricity": 2.25,
      "site_grid": 1.19,
      "operations": 5.73,
      "total": 32.64,
      "electricity_usd_2026_kwh": 0.1784,
      "wacc": 0.0702,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.87,
      "electricity": 4.75,
      "site_grid": 2.86,
      "operations": 7.68,
      "total": 55.15,
      "electricity_usd_2026_kwh": 0.1784,
      "wacc": 0.0702,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.31,
      "electricity": 6.09,
      "site_grid": 2.54,
      "operations": 13.49,
      "total": 72.44,
      "electricity_usd_2026_kwh": 0.1784,
      "wacc": 0.0702,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.2,
      "electricity": 11.18,
      "site_grid": 6.32,
      "operations": 18.29,
      "total": 123.99,
      "electricity_usd_2026_kwh": 0.1784,
      "wacc": 0.0702,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.31,
      "electricity": 14.35,
      "site_grid": 5.62,
      "operations": 32.55,
      "total": 163.84,
      "electricity_usd_2026_kwh": 0.1784,
      "wacc": 0.0702,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.67,
      "electricity": 1.71,
      "site_grid": 1.37,
      "operations": 3.31,
      "total": 25.06,
      "electricity_usd_2026_kwh": 0.1739,
      "wacc": 0.0721,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.57,
      "electricity": 2.19,
      "site_grid": 1.22,
      "operations": 5.73,
      "total": 32.7,
      "electricity_usd_2026_kwh": 0.1739,
      "wacc": 0.0721,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.01,
      "electricity": 4.63,
      "site_grid": 2.94,
      "operations": 7.68,
      "total": 55.26,
      "electricity_usd_2026_kwh": 0.1739,
      "wacc": 0.0721,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.49,
      "electricity": 5.94,
      "site_grid": 2.61,
      "operations": 13.49,
      "total": 72.53,
      "electricity_usd_2026_kwh": 0.1739,
      "wacc": 0.0721,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.51,
      "electricity": 10.9,
      "site_grid": 6.5,
      "operations": 18.29,
      "total": 124.2,
      "electricity_usd_2026_kwh": 0.1739,
      "wacc": 0.0721,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.7,
      "electricity": 13.99,
      "site_grid": 5.77,
      "operations": 32.55,
      "total": 164.01,
      "electricity_usd_2026_kwh": 0.1739,
      "wacc": 0.0721,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.54,
      "electricity": 1.4,
      "site_grid": 1.36,
      "operations": 3.31,
      "total": 24.61,
      "electricity_usd_2026_kwh": 0.143,
      "wacc": 0.0681,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.39,
      "electricity": 1.8,
      "site_grid": 1.21,
      "operations": 5.73,
      "total": 32.14,
      "electricity_usd_2026_kwh": 0.143,
      "wacc": 0.0681,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.71,
      "electricity": 3.81,
      "site_grid": 2.91,
      "operations": 7.68,
      "total": 54.12,
      "electricity_usd_2026_kwh": 0.143,
      "wacc": 0.0681,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.12,
      "electricity": 4.89,
      "site_grid": 2.6,
      "operations": 13.49,
      "total": 71.1,
      "electricity_usd_2026_kwh": 0.143,
      "wacc": 0.0681,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.86,
      "electricity": 8.97,
      "site_grid": 6.45,
      "operations": 18.29,
      "total": 121.56,
      "electricity_usd_2026_kwh": 0.143,
      "wacc": 0.0681,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.88,
      "electricity": 11.51,
      "site_grid": 5.75,
      "operations": 32.55,
      "total": 160.69,
      "electricity_usd_2026_kwh": 0.143,
      "wacc": 0.0681,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.43,
      "electricity": 1.33,
      "site_grid": 1.32,
      "operations": 3.31,
      "total": 24.4,
      "electricity_usd_2026_kwh": 0.1357,
      "wacc": 0.0651,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.26,
      "electricity": 1.71,
      "site_grid": 1.19,
      "operations": 5.73,
      "total": 31.89,
      "electricity_usd_2026_kwh": 0.1357,
      "wacc": 0.0651,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.49,
      "electricity": 3.61,
      "site_grid": 2.84,
      "operations": 7.68,
      "total": 53.63,
      "electricity_usd_2026_kwh": 0.1357,
      "wacc": 0.0651,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.84,
      "electricity": 4.63,
      "site_grid": 2.54,
      "operations": 13.49,
      "total": 70.51,
      "electricity_usd_2026_kwh": 0.1357,
      "wacc": 0.0651,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.37,
      "electricity": 8.51,
      "site_grid": 6.28,
      "operations": 18.29,
      "total": 120.45,
      "electricity_usd_2026_kwh": 0.1357,
      "wacc": 0.0651,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.27,
      "electricity": 10.91,
      "site_grid": 5.62,
      "operations": 32.55,
      "total": 159.36,
      "electricity_usd_2026_kwh": 0.1357,
      "wacc": 0.0651,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.6,
      "electricity": 1.34,
      "site_grid": 1.37,
      "operations": 3.31,
      "total": 24.63,
      "electricity_usd_2026_kwh": 0.1367,
      "wacc": 0.07,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.47,
      "electricity": 1.72,
      "site_grid": 1.22,
      "operations": 5.73,
      "total": 32.15,
      "electricity_usd_2026_kwh": 0.1367,
      "wacc": 0.07,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.85,
      "electricity": 3.64,
      "site_grid": 2.94,
      "operations": 7.68,
      "total": 54.12,
      "electricity_usd_2026_kwh": 0.1367,
      "wacc": 0.07,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.29,
      "electricity": 4.67,
      "site_grid": 2.62,
      "operations": 13.49,
      "total": 71.08,
      "electricity_usd_2026_kwh": 0.1367,
      "wacc": 0.07,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.17,
      "electricity": 8.57,
      "site_grid": 6.51,
      "operations": 18.29,
      "total": 121.54,
      "electricity_usd_2026_kwh": 0.1367,
      "wacc": 0.07,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.27,
      "electricity": 10.99,
      "site_grid": 5.79,
      "operations": 32.55,
      "total": 160.61,
      "electricity_usd_2026_kwh": 0.1367,
      "wacc": 0.07,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.8,
      "electricity": 1.53,
      "site_grid": 1.46,
      "operations": 3.31,
      "total": 25.1,
      "electricity_usd_2026_kwh": 0.156,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.72,
      "electricity": 1.97,
      "site_grid": 1.29,
      "operations": 5.73,
      "total": 32.71,
      "electricity_usd_2026_kwh": 0.156,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.28,
      "electricity": 4.15,
      "site_grid": 3.12,
      "operations": 7.68,
      "total": 55.24,
      "electricity_usd_2026_kwh": 0.156,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.83,
      "electricity": 5.33,
      "site_grid": 2.76,
      "operations": 13.49,
      "total": 72.41,
      "electricity_usd_2026_kwh": 0.156,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.11,
      "electricity": 9.78,
      "site_grid": 6.91,
      "operations": 18.29,
      "total": 124.09,
      "electricity_usd_2026_kwh": 0.156,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.46,
      "electricity": 12.55,
      "site_grid": 6.11,
      "operations": 32.55,
      "total": 163.67,
      "electricity_usd_2026_kwh": 0.156,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.54,
      "electricity": 1.49,
      "site_grid": 1.44,
      "operations": 3.31,
      "total": 24.78,
      "electricity_usd_2026_kwh": 0.1513,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.39,
      "electricity": 1.91,
      "site_grid": 1.29,
      "operations": 5.73,
      "total": 32.31,
      "electricity_usd_2026_kwh": 0.1513,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.71,
      "electricity": 4.03,
      "site_grid": 3.09,
      "operations": 7.68,
      "total": 54.52,
      "electricity_usd_2026_kwh": 0.1513,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.12,
      "electricity": 5.17,
      "site_grid": 2.76,
      "operations": 13.49,
      "total": 71.54,
      "electricity_usd_2026_kwh": 0.1513,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.86,
      "electricity": 9.48,
      "site_grid": 6.84,
      "operations": 18.29,
      "total": 122.48,
      "electricity_usd_2026_kwh": 0.1513,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.89,
      "electricity": 12.17,
      "site_grid": 6.1,
      "operations": 32.55,
      "total": 161.71,
      "electricity_usd_2026_kwh": 0.1513,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.11,
      "electricity": 1.48,
      "site_grid": 1.35,
      "operations": 3.31,
      "total": 24.25,
      "electricity_usd_2026_kwh": 0.1506,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.86,
      "electricity": 1.9,
      "site_grid": 1.22,
      "operations": 5.73,
      "total": 31.71,
      "electricity_usd_2026_kwh": 0.1506,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.8,
      "electricity": 4.01,
      "site_grid": 2.89,
      "operations": 7.68,
      "total": 53.39,
      "electricity_usd_2026_kwh": 0.1506,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.98,
      "electricity": 5.14,
      "site_grid": 2.62,
      "operations": 13.49,
      "total": 70.24,
      "electricity_usd_2026_kwh": 0.1506,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.84,
      "electricity": 9.44,
      "site_grid": 6.4,
      "operations": 18.29,
      "total": 119.97,
      "electricity_usd_2026_kwh": 0.1506,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.36,
      "electricity": 12.12,
      "site_grid": 5.8,
      "operations": 32.55,
      "total": 158.82,
      "electricity_usd_2026_kwh": 0.1506,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.3,
      "electricity": 1.54,
      "site_grid": 1.41,
      "operations": 3.31,
      "total": 24.56,
      "electricity_usd_2026_kwh": 0.1564,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.1,
      "electricity": 1.97,
      "site_grid": 1.27,
      "operations": 5.73,
      "total": 32.06,
      "electricity_usd_2026_kwh": 0.1564,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.21,
      "electricity": 4.16,
      "site_grid": 3.02,
      "operations": 7.68,
      "total": 54.07,
      "electricity_usd_2026_kwh": 0.1564,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.49,
      "electricity": 5.34,
      "site_grid": 2.72,
      "operations": 13.49,
      "total": 71.04,
      "electricity_usd_2026_kwh": 0.1564,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.74,
      "electricity": 9.8,
      "site_grid": 6.68,
      "operations": 18.29,
      "total": 121.51,
      "electricity_usd_2026_kwh": 0.1564,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.48,
      "electricity": 12.58,
      "site_grid": 6.01,
      "operations": 32.55,
      "total": 160.62,
      "electricity_usd_2026_kwh": 0.1564,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.81,
      "electricity": 2.3,
      "site_grid": 1.76,
      "operations": 3.31,
      "total": 26.19,
      "electricity_usd_2026_kwh": 0.2346,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.74,
      "electricity": 2.96,
      "site_grid": 1.56,
      "operations": 5.73,
      "total": 33.98,
      "electricity_usd_2026_kwh": 0.2346,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.31,
      "electricity": 6.24,
      "site_grid": 3.77,
      "operations": 7.68,
      "total": 58.01,
      "electricity_usd_2026_kwh": 0.2346,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.87,
      "electricity": 8.01,
      "site_grid": 3.33,
      "operations": 13.49,
      "total": 75.71,
      "electricity_usd_2026_kwh": 0.2346,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.18,
      "electricity": 14.71,
      "site_grid": 8.34,
      "operations": 18.29,
      "total": 130.52,
      "electricity_usd_2026_kwh": 0.2346,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.54,
      "electricity": 18.87,
      "site_grid": 7.37,
      "operations": 32.55,
      "total": 171.34,
      "electricity_usd_2026_kwh": 0.2346,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.16,
      "electricity": 3.03,
      "site_grid": 1.94,
      "operations": 3.31,
      "total": 27.44,
      "electricity_usd_2026_kwh": 0.3085,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.18,
      "electricity": 3.89,
      "site_grid": 1.69,
      "operations": 5.73,
      "total": 35.48,
      "electricity_usd_2026_kwh": 0.3085,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.05,
      "electricity": 8.21,
      "site_grid": 4.15,
      "operations": 7.68,
      "total": 61.1,
      "electricity_usd_2026_kwh": 0.3085,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.8,
      "electricity": 10.54,
      "site_grid": 3.63,
      "operations": 13.49,
      "total": 79.46,
      "electricity_usd_2026_kwh": 0.3085,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.82,
      "electricity": 19.34,
      "site_grid": 9.18,
      "operations": 18.29,
      "total": 137.64,
      "electricity_usd_2026_kwh": 0.3085,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 114.6,
      "electricity": 24.82,
      "site_grid": 8.02,
      "operations": 32.55,
      "total": 180.0,
      "electricity_usd_2026_kwh": 0.3085,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.25,
      "electricity": 2.14,
      "site_grid": 1.9,
      "operations": 3.31,
      "total": 26.6,
      "electricity_usd_2026_kwh": 0.2175,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.28,
      "electricity": 2.74,
      "site_grid": 1.66,
      "operations": 5.73,
      "total": 34.41,
      "electricity_usd_2026_kwh": 0.2175,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.24,
      "electricity": 5.79,
      "site_grid": 4.08,
      "operations": 7.68,
      "total": 58.79,
      "electricity_usd_2026_kwh": 0.2175,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.03,
      "electricity": 7.43,
      "site_grid": 3.56,
      "operations": 13.49,
      "total": 76.51,
      "electricity_usd_2026_kwh": 0.2175,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 91.23,
      "electricity": 13.63,
      "site_grid": 9.03,
      "operations": 18.29,
      "total": 132.18,
      "electricity_usd_2026_kwh": 0.2175,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 115.11,
      "electricity": 17.49,
      "site_grid": 7.87,
      "operations": 32.55,
      "total": 173.03,
      "electricity_usd_2026_kwh": 0.2175,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.28,
      "electricity": 1.87,
      "site_grid": 1.89,
      "operations": 3.31,
      "total": 26.35,
      "electricity_usd_2026_kwh": 0.1906,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.32,
      "electricity": 2.4,
      "site_grid": 1.65,
      "operations": 5.73,
      "total": 34.1,
      "electricity_usd_2026_kwh": 0.1906,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.3,
      "electricity": 5.07,
      "site_grid": 4.05,
      "operations": 7.68,
      "total": 58.1,
      "electricity_usd_2026_kwh": 0.1906,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.11,
      "electricity": 6.51,
      "site_grid": 3.53,
      "operations": 13.49,
      "total": 75.64,
      "electricity_usd_2026_kwh": 0.1906,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 91.37,
      "electricity": 11.95,
      "site_grid": 8.96,
      "operations": 18.29,
      "total": 130.57,
      "electricity_usd_2026_kwh": 0.1906,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 115.29,
      "electricity": 15.33,
      "site_grid": 7.8,
      "operations": 32.55,
      "total": 170.97,
      "electricity_usd_2026_kwh": 0.1906,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.29,
      "electricity": 1.74,
      "site_grid": 1.9,
      "operations": 3.31,
      "total": 26.24,
      "electricity_usd_2026_kwh": 0.1775,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.34,
      "electricity": 2.24,
      "site_grid": 1.65,
      "operations": 5.73,
      "total": 33.95,
      "electricity_usd_2026_kwh": 0.1775,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.33,
      "electricity": 4.72,
      "site_grid": 4.07,
      "operations": 7.68,
      "total": 57.8,
      "electricity_usd_2026_kwh": 0.1775,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.15,
      "electricity": 6.06,
      "site_grid": 3.54,
      "operations": 13.49,
      "total": 75.24,
      "electricity_usd_2026_kwh": 0.1775,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 91.43,
      "electricity": 11.13,
      "site_grid": 9.0,
      "operations": 18.29,
      "total": 129.85,
      "electricity_usd_2026_kwh": 0.1775,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 115.36,
      "electricity": 14.28,
      "site_grid": 7.84,
      "operations": 32.55,
      "total": 170.03,
      "electricity_usd_2026_kwh": 0.1775,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.63,
      "electricity": 3.39,
      "site_grid": 1.62,
      "operations": 3.49,
      "total": 28.13,
      "electricity_usd_2026_kwh": 0.3251,
      "wacc": 0.0788,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.81,
      "electricity": 4.35,
      "site_grid": 1.62,
      "operations": 6.1,
      "total": 36.89,
      "electricity_usd_2026_kwh": 0.3251,
      "wacc": 0.0788,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.05,
      "electricity": 9.19,
      "site_grid": 3.48,
      "operations": 8.06,
      "total": 62.78,
      "electricity_usd_2026_kwh": 0.3251,
      "wacc": 0.0788,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.17,
      "electricity": 11.8,
      "site_grid": 3.47,
      "operations": 14.29,
      "total": 82.73,
      "electricity_usd_2026_kwh": 0.3251,
      "wacc": 0.0788,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 93.04,
      "electricity": 21.65,
      "site_grid": 7.69,
      "operations": 19.13,
      "total": 141.51,
      "electricity_usd_2026_kwh": 0.3251,
      "wacc": 0.0788,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 117.62,
      "electricity": 27.78,
      "site_grid": 7.68,
      "operations": 34.34,
      "total": 187.42,
      "electricity_usd_2026_kwh": 0.3251,
      "wacc": 0.0788,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.47,
      "electricity": 4.04,
      "site_grid": 1.56,
      "operations": 3.49,
      "total": 28.56,
      "electricity_usd_2026_kwh": 0.3869,
      "wacc": 0.0745,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.62,
      "electricity": 5.18,
      "site_grid": 1.56,
      "operations": 6.1,
      "total": 37.46,
      "electricity_usd_2026_kwh": 0.3869,
      "wacc": 0.0745,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.72,
      "electricity": 10.94,
      "site_grid": 3.33,
      "operations": 8.06,
      "total": 64.06,
      "electricity_usd_2026_kwh": 0.3869,
      "wacc": 0.0745,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.75,
      "electricity": 14.04,
      "site_grid": 3.35,
      "operations": 14.29,
      "total": 84.43,
      "electricity_usd_2026_kwh": 0.3869,
      "wacc": 0.0745,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 92.31,
      "electricity": 25.76,
      "site_grid": 7.38,
      "operations": 19.13,
      "total": 144.58,
      "electricity_usd_2026_kwh": 0.3869,
      "wacc": 0.0745,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 116.7,
      "electricity": 33.07,
      "site_grid": 7.41,
      "operations": 34.34,
      "total": 191.52,
      "electricity_usd_2026_kwh": 0.3869,
      "wacc": 0.0745,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.02,
      "electricity": 4.42,
      "site_grid": 1.72,
      "operations": 3.49,
      "total": 29.65,
      "electricity_usd_2026_kwh": 0.4238,
      "wacc": 0.0897,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.3,
      "electricity": 5.67,
      "site_grid": 1.7,
      "operations": 6.1,
      "total": 38.77,
      "electricity_usd_2026_kwh": 0.4238,
      "wacc": 0.0897,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.89,
      "electricity": 11.98,
      "site_grid": 3.69,
      "operations": 8.06,
      "total": 66.62,
      "electricity_usd_2026_kwh": 0.4238,
      "wacc": 0.0897,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 54.21,
      "electricity": 15.38,
      "site_grid": 3.64,
      "operations": 14.29,
      "total": 87.53,
      "electricity_usd_2026_kwh": 0.4238,
      "wacc": 0.0897,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.88,
      "electricity": 28.21,
      "site_grid": 8.16,
      "operations": 19.13,
      "total": 150.39,
      "electricity_usd_2026_kwh": 0.4238,
      "wacc": 0.0897,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 119.94,
      "electricity": 36.22,
      "site_grid": 8.05,
      "operations": 34.34,
      "total": 198.55,
      "electricity_usd_2026_kwh": 0.4238,
      "wacc": 0.0897,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.76,
      "electricity": 4.02,
      "site_grid": 1.96,
      "operations": 3.49,
      "total": 30.23,
      "electricity_usd_2026_kwh": 0.3854,
      "wacc": 0.1102,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 26.23,
      "electricity": 5.16,
      "site_grid": 1.89,
      "operations": 6.1,
      "total": 39.38,
      "electricity_usd_2026_kwh": 0.3854,
      "wacc": 0.1102,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 44.47,
      "electricity": 10.89,
      "site_grid": 4.2,
      "operations": 8.06,
      "total": 67.63,
      "electricity_usd_2026_kwh": 0.3854,
      "wacc": 0.1102,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 56.2,
      "electricity": 13.98,
      "site_grid": 4.06,
      "operations": 14.29,
      "total": 88.54,
      "electricity_usd_2026_kwh": 0.3854,
      "wacc": 0.1102,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 98.39,
      "electricity": 25.66,
      "site_grid": 9.29,
      "operations": 19.13,
      "total": 152.47,
      "electricity_usd_2026_kwh": 0.3854,
      "wacc": 0.1102,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 124.34,
      "electricity": 32.93,
      "site_grid": 8.98,
      "operations": 34.34,
      "total": 200.59,
      "electricity_usd_2026_kwh": 0.3854,
      "wacc": 0.1102,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.92,
      "electricity": 3.53,
      "site_grid": 1.74,
      "operations": 3.49,
      "total": 28.68,
      "electricity_usd_2026_kwh": 0.3388,
      "wacc": 0.0871,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.19,
      "electricity": 4.53,
      "site_grid": 1.72,
      "operations": 6.1,
      "total": 37.54,
      "electricity_usd_2026_kwh": 0.3388,
      "wacc": 0.0871,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.69,
      "electricity": 9.58,
      "site_grid": 3.72,
      "operations": 8.06,
      "total": 64.05,
      "electricity_usd_2026_kwh": 0.3388,
      "wacc": 0.0871,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.96,
      "electricity": 12.29,
      "site_grid": 3.68,
      "operations": 14.29,
      "total": 84.23,
      "electricity_usd_2026_kwh": 0.3388,
      "wacc": 0.0871,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.44,
      "electricity": 22.56,
      "site_grid": 8.22,
      "operations": 19.13,
      "total": 144.35,
      "electricity_usd_2026_kwh": 0.3388,
      "wacc": 0.0871,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 119.38,
      "electricity": 28.95,
      "site_grid": 8.14,
      "operations": 34.34,
      "total": 190.81,
      "electricity_usd_2026_kwh": 0.3388,
      "wacc": 0.0871,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.24,
      "electricity": 2.26,
      "site_grid": 1.56,
      "operations": 3.49,
      "total": 26.56,
      "electricity_usd_2026_kwh": 0.2171,
      "wacc": 0.0681,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.33,
      "electricity": 2.91,
      "site_grid": 1.58,
      "operations": 6.1,
      "total": 34.92,
      "electricity_usd_2026_kwh": 0.2171,
      "wacc": 0.0681,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.23,
      "electricity": 6.14,
      "site_grid": 3.35,
      "operations": 8.06,
      "total": 58.79,
      "electricity_usd_2026_kwh": 0.2171,
      "wacc": 0.0681,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.13,
      "electricity": 7.88,
      "site_grid": 3.39,
      "operations": 14.29,
      "total": 77.7,
      "electricity_usd_2026_kwh": 0.2171,
      "wacc": 0.0681,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 91.22,
      "electricity": 14.46,
      "site_grid": 7.42,
      "operations": 19.13,
      "total": 132.23,
      "electricity_usd_2026_kwh": 0.2171,
      "wacc": 0.0681,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 115.34,
      "electricity": 18.56,
      "site_grid": 7.51,
      "operations": 34.34,
      "total": 175.74,
      "electricity_usd_2026_kwh": 0.2171,
      "wacc": 0.0681,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.14,
      "electricity": 1.86,
      "site_grid": 1.52,
      "operations": 3.49,
      "total": 26.02,
      "electricity_usd_2026_kwh": 0.1786,
      "wacc": 0.0651,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.2,
      "electricity": 2.39,
      "site_grid": 1.55,
      "operations": 6.1,
      "total": 34.24,
      "electricity_usd_2026_kwh": 0.1786,
      "wacc": 0.0651,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.0,
      "electricity": 5.05,
      "site_grid": 3.26,
      "operations": 8.06,
      "total": 57.38,
      "electricity_usd_2026_kwh": 0.1786,
      "wacc": 0.0651,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.85,
      "electricity": 6.48,
      "site_grid": 3.32,
      "operations": 14.29,
      "total": 75.94,
      "electricity_usd_2026_kwh": 0.1786,
      "wacc": 0.0651,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.72,
      "electricity": 11.89,
      "site_grid": 7.22,
      "operations": 19.13,
      "total": 128.97,
      "electricity_usd_2026_kwh": 0.1786,
      "wacc": 0.0651,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 114.7,
      "electricity": 15.26,
      "site_grid": 7.34,
      "operations": 34.34,
      "total": 171.64,
      "electricity_usd_2026_kwh": 0.1786,
      "wacc": 0.0651,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.31,
      "electricity": 2.23,
      "site_grid": 1.58,
      "operations": 3.49,
      "total": 26.61,
      "electricity_usd_2026_kwh": 0.2138,
      "wacc": 0.07,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.42,
      "electricity": 2.86,
      "site_grid": 1.6,
      "operations": 6.1,
      "total": 34.97,
      "electricity_usd_2026_kwh": 0.2138,
      "wacc": 0.07,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.38,
      "electricity": 6.04,
      "site_grid": 3.39,
      "operations": 8.06,
      "total": 58.87,
      "electricity_usd_2026_kwh": 0.2138,
      "wacc": 0.07,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.32,
      "electricity": 7.76,
      "site_grid": 3.42,
      "operations": 14.29,
      "total": 77.79,
      "electricity_usd_2026_kwh": 0.2138,
      "wacc": 0.07,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 91.54,
      "electricity": 14.23,
      "site_grid": 7.49,
      "operations": 19.13,
      "total": 132.4,
      "electricity_usd_2026_kwh": 0.2138,
      "wacc": 0.07,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 115.74,
      "electricity": 18.27,
      "site_grid": 7.56,
      "operations": 34.34,
      "total": 175.91,
      "electricity_usd_2026_kwh": 0.2138,
      "wacc": 0.07,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.52,
      "electricity": 2.61,
      "site_grid": 1.68,
      "operations": 3.49,
      "total": 27.3,
      "electricity_usd_2026_kwh": 0.25,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.68,
      "electricity": 3.35,
      "site_grid": 1.68,
      "operations": 6.1,
      "total": 35.81,
      "electricity_usd_2026_kwh": 0.25,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.82,
      "electricity": 7.07,
      "site_grid": 3.59,
      "operations": 8.06,
      "total": 60.55,
      "electricity_usd_2026_kwh": 0.25,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.87,
      "electricity": 9.07,
      "site_grid": 3.6,
      "operations": 14.29,
      "total": 79.84,
      "electricity_usd_2026_kwh": 0.25,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 92.52,
      "electricity": 16.64,
      "site_grid": 7.95,
      "operations": 19.13,
      "total": 136.26,
      "electricity_usd_2026_kwh": 0.25,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 116.98,
      "electricity": 21.37,
      "site_grid": 7.97,
      "operations": 34.34,
      "total": 180.65,
      "electricity_usd_2026_kwh": 0.25,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.25,
      "electricity": 2.58,
      "site_grid": 1.66,
      "operations": 3.49,
      "total": 26.98,
      "electricity_usd_2026_kwh": 0.2476,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.33,
      "electricity": 3.31,
      "site_grid": 1.68,
      "operations": 6.1,
      "total": 35.43,
      "electricity_usd_2026_kwh": 0.2476,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.24,
      "electricity": 7.0,
      "site_grid": 3.56,
      "operations": 8.06,
      "total": 59.86,
      "electricity_usd_2026_kwh": 0.2476,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.14,
      "electricity": 8.98,
      "site_grid": 3.6,
      "operations": 14.29,
      "total": 79.01,
      "electricity_usd_2026_kwh": 0.2476,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 91.23,
      "electricity": 16.48,
      "site_grid": 7.87,
      "operations": 19.13,
      "total": 134.71,
      "electricity_usd_2026_kwh": 0.2476,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 115.35,
      "electricity": 21.16,
      "site_grid": 7.96,
      "operations": 34.34,
      "total": 178.8,
      "electricity_usd_2026_kwh": 0.2476,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.8,
      "electricity": 2.14,
      "site_grid": 1.55,
      "operations": 3.49,
      "total": 25.98,
      "electricity_usd_2026_kwh": 0.205,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.78,
      "electricity": 2.74,
      "site_grid": 1.6,
      "operations": 6.1,
      "total": 34.22,
      "electricity_usd_2026_kwh": 0.205,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.29,
      "electricity": 5.8,
      "site_grid": 3.33,
      "operations": 8.06,
      "total": 57.47,
      "electricity_usd_2026_kwh": 0.205,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.95,
      "electricity": 7.44,
      "site_grid": 3.42,
      "operations": 14.29,
      "total": 76.1,
      "electricity_usd_2026_kwh": 0.205,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.13,
      "electricity": 13.65,
      "site_grid": 7.36,
      "operations": 19.13,
      "total": 129.27,
      "electricity_usd_2026_kwh": 0.205,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.71,
      "electricity": 17.52,
      "site_grid": 7.57,
      "operations": 34.34,
      "total": 172.13,
      "electricity_usd_2026_kwh": 0.205,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.0,
      "electricity": 2.6,
      "site_grid": 1.62,
      "operations": 3.49,
      "total": 26.72,
      "electricity_usd_2026_kwh": 0.2497,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.03,
      "electricity": 3.34,
      "site_grid": 1.65,
      "operations": 6.1,
      "total": 35.12,
      "electricity_usd_2026_kwh": 0.2497,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.71,
      "electricity": 7.06,
      "site_grid": 3.47,
      "operations": 8.06,
      "total": 59.3,
      "electricity_usd_2026_kwh": 0.2497,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.48,
      "electricity": 9.06,
      "site_grid": 3.54,
      "operations": 14.29,
      "total": 78.38,
      "electricity_usd_2026_kwh": 0.2497,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.06,
      "electricity": 16.63,
      "site_grid": 7.68,
      "operations": 19.13,
      "total": 133.5,
      "electricity_usd_2026_kwh": 0.2497,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 113.88,
      "electricity": 21.34,
      "site_grid": 7.84,
      "operations": 34.34,
      "total": 177.4,
      "electricity_usd_2026_kwh": 0.2497,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.53,
      "electricity": 3.49,
      "site_grid": 2.03,
      "operations": 3.49,
      "total": 28.54,
      "electricity_usd_2026_kwh": 0.335,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.7,
      "electricity": 4.48,
      "site_grid": 2.03,
      "operations": 6.1,
      "total": 37.31,
      "electricity_usd_2026_kwh": 0.335,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.85,
      "electricity": 9.47,
      "site_grid": 4.34,
      "operations": 8.06,
      "total": 63.73,
      "electricity_usd_2026_kwh": 0.335,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.91,
      "electricity": 12.16,
      "site_grid": 4.35,
      "operations": 14.29,
      "total": 83.71,
      "electricity_usd_2026_kwh": 0.335,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 92.59,
      "electricity": 22.31,
      "site_grid": 9.6,
      "operations": 19.13,
      "total": 143.63,
      "electricity_usd_2026_kwh": 0.335,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 117.06,
      "electricity": 28.63,
      "site_grid": 9.62,
      "operations": 34.34,
      "total": 189.65,
      "electricity_usd_2026_kwh": 0.335,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.89,
      "electricity": 3.38,
      "site_grid": 2.23,
      "operations": 3.49,
      "total": 28.99,
      "electricity_usd_2026_kwh": 0.324,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.15,
      "electricity": 4.34,
      "site_grid": 2.21,
      "operations": 6.1,
      "total": 37.8,
      "electricity_usd_2026_kwh": 0.324,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.62,
      "electricity": 9.16,
      "site_grid": 4.78,
      "operations": 8.06,
      "total": 64.63,
      "electricity_usd_2026_kwh": 0.324,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.88,
      "electricity": 11.76,
      "site_grid": 4.73,
      "operations": 14.29,
      "total": 84.67,
      "electricity_usd_2026_kwh": 0.324,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.3,
      "electricity": 21.57,
      "site_grid": 10.57,
      "operations": 19.13,
      "total": 145.58,
      "electricity_usd_2026_kwh": 0.324,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 119.21,
      "electricity": 27.69,
      "site_grid": 10.47,
      "operations": 34.34,
      "total": 191.71,
      "electricity_usd_2026_kwh": 0.324,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.98,
      "electricity": 2.99,
      "site_grid": 2.19,
      "operations": 3.49,
      "total": 28.66,
      "electricity_usd_2026_kwh": 0.2868,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.26,
      "electricity": 3.84,
      "site_grid": 2.17,
      "operations": 6.1,
      "total": 37.37,
      "electricity_usd_2026_kwh": 0.2868,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.82,
      "electricity": 8.11,
      "site_grid": 4.7,
      "operations": 8.06,
      "total": 63.68,
      "electricity_usd_2026_kwh": 0.2868,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 54.12,
      "electricity": 10.41,
      "site_grid": 4.64,
      "operations": 14.29,
      "total": 83.47,
      "electricity_usd_2026_kwh": 0.2868,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.72,
      "electricity": 19.1,
      "site_grid": 10.39,
      "operations": 19.13,
      "total": 143.34,
      "electricity_usd_2026_kwh": 0.2868,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 119.74,
      "electricity": 24.51,
      "site_grid": 10.27,
      "operations": 34.34,
      "total": 188.85,
      "electricity_usd_2026_kwh": 0.2868,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.01,
      "electricity": 2.87,
      "site_grid": 2.18,
      "operations": 3.49,
      "total": 28.55,
      "electricity_usd_2026_kwh": 0.2755,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.3,
      "electricity": 3.69,
      "site_grid": 2.15,
      "operations": 6.1,
      "total": 37.23,
      "electricity_usd_2026_kwh": 0.2755,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.88,
      "electricity": 7.79,
      "site_grid": 4.66,
      "operations": 8.06,
      "total": 63.4,
      "electricity_usd_2026_kwh": 0.2755,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 54.2,
      "electricity": 10.0,
      "site_grid": 4.6,
      "operations": 14.29,
      "total": 83.1,
      "electricity_usd_2026_kwh": 0.2755,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.87,
      "electricity": 18.35,
      "site_grid": 10.31,
      "operations": 19.13,
      "total": 142.66,
      "electricity_usd_2026_kwh": 0.2755,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 119.92,
      "electricity": 23.55,
      "site_grid": 10.18,
      "operations": 34.34,
      "total": 187.98,
      "electricity_usd_2026_kwh": 0.2755,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.03,
      "electricity": 2.9,
      "site_grid": 2.19,
      "operations": 3.49,
      "total": 28.61,
      "electricity_usd_2026_kwh": 0.2785,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.32,
      "electricity": 3.73,
      "site_grid": 2.16,
      "operations": 6.1,
      "total": 37.3,
      "electricity_usd_2026_kwh": 0.2785,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.91,
      "electricity": 7.87,
      "site_grid": 4.68,
      "operations": 8.06,
      "total": 63.53,
      "electricity_usd_2026_kwh": 0.2785,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 54.24,
      "electricity": 10.11,
      "site_grid": 4.62,
      "operations": 14.29,
      "total": 83.26,
      "electricity_usd_2026_kwh": 0.2785,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.93,
      "electricity": 18.54,
      "site_grid": 10.36,
      "operations": 19.13,
      "total": 142.97,
      "electricity_usd_2026_kwh": 0.2785,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 120.0,
      "electricity": 23.8,
      "site_grid": 10.23,
      "operations": 34.34,
      "total": 188.37,
      "electricity_usd_2026_kwh": 0.2785,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.02,
      "electricity": 1.99,
      "site_grid": 1.35,
      "operations": 3.24,
      "total": 24.61,
      "electricity_usd_2026_kwh": 0.2124,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.71,
      "electricity": 2.56,
      "site_grid": 1.24,
      "operations": 5.79,
      "total": 32.29,
      "electricity_usd_2026_kwh": 0.2124,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.62,
      "electricity": 5.4,
      "site_grid": 2.89,
      "operations": 7.53,
      "total": 54.44,
      "electricity_usd_2026_kwh": 0.2124,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.65,
      "electricity": 6.93,
      "site_grid": 2.67,
      "operations": 13.62,
      "total": 71.86,
      "electricity_usd_2026_kwh": 0.2124,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.44,
      "electricity": 12.72,
      "site_grid": 6.4,
      "operations": 17.95,
      "total": 122.51,
      "electricity_usd_2026_kwh": 0.2124,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.63,
      "electricity": 16.31,
      "site_grid": 5.9,
      "operations": 32.82,
      "total": 162.66,
      "electricity_usd_2026_kwh": 0.2124,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.88,
      "electricity": 2.1,
      "site_grid": 1.3,
      "operations": 3.24,
      "total": 24.52,
      "electricity_usd_2026_kwh": 0.224,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.53,
      "electricity": 2.69,
      "site_grid": 1.2,
      "operations": 5.79,
      "total": 32.21,
      "electricity_usd_2026_kwh": 0.224,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.31,
      "electricity": 5.7,
      "site_grid": 2.78,
      "operations": 7.53,
      "total": 54.31,
      "electricity_usd_2026_kwh": 0.224,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.26,
      "electricity": 7.3,
      "site_grid": 2.57,
      "operations": 13.62,
      "total": 71.76,
      "electricity_usd_2026_kwh": 0.224,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.76,
      "electricity": 13.41,
      "site_grid": 6.14,
      "operations": 17.95,
      "total": 122.26,
      "electricity_usd_2026_kwh": 0.224,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.78,
      "electricity": 17.2,
      "site_grid": 5.69,
      "operations": 32.82,
      "total": 162.49,
      "electricity_usd_2026_kwh": 0.224,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.56,
      "electricity": 1.79,
      "site_grid": 1.22,
      "operations": 3.24,
      "total": 23.81,
      "electricity_usd_2026_kwh": 0.1913,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.12,
      "electricity": 2.3,
      "site_grid": 1.14,
      "operations": 5.79,
      "total": 31.35,
      "electricity_usd_2026_kwh": 0.1913,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.62,
      "electricity": 4.86,
      "site_grid": 2.61,
      "operations": 7.53,
      "total": 52.62,
      "electricity_usd_2026_kwh": 0.1913,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.4,
      "electricity": 6.24,
      "site_grid": 2.45,
      "operations": 13.62,
      "total": 69.7,
      "electricity_usd_2026_kwh": 0.1913,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.22,
      "electricity": 11.46,
      "site_grid": 5.78,
      "operations": 17.95,
      "total": 118.41,
      "electricity_usd_2026_kwh": 0.1913,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.86,
      "electricity": 14.69,
      "site_grid": 5.42,
      "operations": 32.82,
      "total": 157.79,
      "electricity_usd_2026_kwh": 0.1913,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.74,
      "electricity": 1.78,
      "site_grid": 1.28,
      "operations": 3.24,
      "total": 24.03,
      "electricity_usd_2026_kwh": 0.1897,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.35,
      "electricity": 2.28,
      "site_grid": 1.19,
      "operations": 5.79,
      "total": 31.6,
      "electricity_usd_2026_kwh": 0.1897,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.0,
      "electricity": 4.82,
      "site_grid": 2.73,
      "operations": 7.53,
      "total": 53.09,
      "electricity_usd_2026_kwh": 0.1897,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.88,
      "electricity": 6.18,
      "site_grid": 2.55,
      "operations": 13.62,
      "total": 70.23,
      "electricity_usd_2026_kwh": 0.1897,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.08,
      "electricity": 11.36,
      "site_grid": 6.05,
      "operations": 17.95,
      "total": 119.43,
      "electricity_usd_2026_kwh": 0.1897,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.93,
      "electricity": 14.56,
      "site_grid": 5.63,
      "operations": 32.82,
      "total": 158.95,
      "electricity_usd_2026_kwh": 0.1897,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.8,
      "electricity": 1.43,
      "site_grid": 1.31,
      "operations": 3.24,
      "total": 23.79,
      "electricity_usd_2026_kwh": 0.1529,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.43,
      "electricity": 1.84,
      "site_grid": 1.22,
      "operations": 5.79,
      "total": 31.27,
      "electricity_usd_2026_kwh": 0.1529,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.14,
      "electricity": 3.89,
      "site_grid": 2.81,
      "operations": 7.53,
      "total": 52.37,
      "electricity_usd_2026_kwh": 0.1529,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.05,
      "electricity": 4.99,
      "site_grid": 2.61,
      "operations": 13.62,
      "total": 69.26,
      "electricity_usd_2026_kwh": 0.1529,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.38,
      "electricity": 9.16,
      "site_grid": 6.22,
      "operations": 17.95,
      "total": 117.7,
      "electricity_usd_2026_kwh": 0.1529,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.3,
      "electricity": 11.74,
      "site_grid": 5.78,
      "operations": 32.82,
      "total": 156.64,
      "electricity_usd_2026_kwh": 0.1529,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.67,
      "electricity": 1.13,
      "site_grid": 1.3,
      "operations": 3.24,
      "total": 23.34,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.26,
      "electricity": 1.45,
      "site_grid": 1.21,
      "operations": 5.79,
      "total": 30.71,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.85,
      "electricity": 3.06,
      "site_grid": 2.79,
      "operations": 7.53,
      "total": 51.23,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.69,
      "electricity": 3.92,
      "site_grid": 2.6,
      "operations": 13.62,
      "total": 67.84,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.75,
      "electricity": 7.21,
      "site_grid": 6.16,
      "operations": 17.95,
      "total": 115.07,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.51,
      "electricity": 9.24,
      "site_grid": 5.76,
      "operations": 32.82,
      "total": 153.33,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.57,
      "electricity": 1.05,
      "site_grid": 1.27,
      "operations": 3.24,
      "total": 23.12,
      "electricity_usd_2026_kwh": 0.1114,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.14,
      "electricity": 1.34,
      "site_grid": 1.19,
      "operations": 5.79,
      "total": 30.45,
      "electricity_usd_2026_kwh": 0.1114,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.64,
      "electricity": 2.83,
      "site_grid": 2.71,
      "operations": 7.53,
      "total": 50.72,
      "electricity_usd_2026_kwh": 0.1114,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.43,
      "electricity": 3.63,
      "site_grid": 2.54,
      "operations": 13.62,
      "total": 67.22,
      "electricity_usd_2026_kwh": 0.1114,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.28,
      "electricity": 6.67,
      "site_grid": 6.0,
      "operations": 17.95,
      "total": 113.9,
      "electricity_usd_2026_kwh": 0.1114,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.93,
      "electricity": 8.56,
      "site_grid": 5.63,
      "operations": 32.82,
      "total": 151.93,
      "electricity_usd_2026_kwh": 0.1114,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.73,
      "electricity": 1.0,
      "site_grid": 1.31,
      "operations": 3.24,
      "total": 23.29,
      "electricity_usd_2026_kwh": 0.1065,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.34,
      "electricity": 1.28,
      "site_grid": 1.22,
      "operations": 5.79,
      "total": 30.63,
      "electricity_usd_2026_kwh": 0.1065,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.99,
      "electricity": 2.71,
      "site_grid": 2.82,
      "operations": 7.53,
      "total": 51.04,
      "electricity_usd_2026_kwh": 0.1065,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.86,
      "electricity": 3.47,
      "site_grid": 2.62,
      "operations": 13.62,
      "total": 67.57,
      "electricity_usd_2026_kwh": 0.1065,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.05,
      "electricity": 6.38,
      "site_grid": 6.23,
      "operations": 17.95,
      "total": 114.6,
      "electricity_usd_2026_kwh": 0.1065,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.89,
      "electricity": 8.18,
      "site_grid": 5.8,
      "operations": 32.82,
      "total": 152.69,
      "electricity_usd_2026_kwh": 0.1065,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.92,
      "electricity": 1.06,
      "site_grid": 1.4,
      "operations": 3.24,
      "total": 23.62,
      "electricity_usd_2026_kwh": 0.113,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.58,
      "electricity": 1.36,
      "site_grid": 1.29,
      "operations": 5.79,
      "total": 31.02,
      "electricity_usd_2026_kwh": 0.113,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.4,
      "electricity": 2.87,
      "site_grid": 2.99,
      "operations": 7.53,
      "total": 51.8,
      "electricity_usd_2026_kwh": 0.113,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.38,
      "electricity": 3.69,
      "site_grid": 2.77,
      "operations": 13.62,
      "total": 68.45,
      "electricity_usd_2026_kwh": 0.113,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.96,
      "electricity": 6.77,
      "site_grid": 6.62,
      "operations": 17.95,
      "total": 116.3,
      "electricity_usd_2026_kwh": 0.113,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.03,
      "electricity": 8.68,
      "site_grid": 6.12,
      "operations": 32.82,
      "total": 154.65,
      "electricity_usd_2026_kwh": 0.113,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.67,
      "electricity": 1.05,
      "site_grid": 1.38,
      "operations": 3.24,
      "total": 23.35,
      "electricity_usd_2026_kwh": 0.1124,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.26,
      "electricity": 1.35,
      "site_grid": 1.29,
      "operations": 5.79,
      "total": 30.69,
      "electricity_usd_2026_kwh": 0.1124,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.86,
      "electricity": 2.86,
      "site_grid": 2.96,
      "operations": 7.53,
      "total": 51.2,
      "electricity_usd_2026_kwh": 0.1124,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.7,
      "electricity": 3.66,
      "site_grid": 2.76,
      "operations": 13.62,
      "total": 67.74,
      "electricity_usd_2026_kwh": 0.1124,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.75,
      "electricity": 6.73,
      "site_grid": 6.54,
      "operations": 17.95,
      "total": 114.97,
      "electricity_usd_2026_kwh": 0.1124,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.52,
      "electricity": 8.63,
      "site_grid": 6.11,
      "operations": 32.82,
      "total": 153.08,
      "electricity_usd_2026_kwh": 0.1124,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.26,
      "electricity": 1.15,
      "site_grid": 1.29,
      "operations": 3.24,
      "total": 22.94,
      "electricity_usd_2026_kwh": 0.1231,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.75,
      "electricity": 1.48,
      "site_grid": 1.22,
      "operations": 5.79,
      "total": 30.24,
      "electricity_usd_2026_kwh": 0.1231,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.97,
      "electricity": 3.13,
      "site_grid": 2.76,
      "operations": 7.53,
      "total": 50.39,
      "electricity_usd_2026_kwh": 0.1231,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.59,
      "electricity": 4.01,
      "site_grid": 2.62,
      "operations": 13.62,
      "total": 66.84,
      "electricity_usd_2026_kwh": 0.1231,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.8,
      "electricity": 7.37,
      "site_grid": 6.1,
      "operations": 17.95,
      "total": 113.22,
      "electricity_usd_2026_kwh": 0.1231,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.08,
      "electricity": 9.45,
      "site_grid": 5.79,
      "operations": 32.82,
      "total": 151.14,
      "electricity_usd_2026_kwh": 0.1231,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.44,
      "electricity": 1.21,
      "site_grid": 1.35,
      "operations": 3.24,
      "total": 23.24,
      "electricity_usd_2026_kwh": 0.129,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.98,
      "electricity": 1.55,
      "site_grid": 1.27,
      "operations": 5.79,
      "total": 30.58,
      "electricity_usd_2026_kwh": 0.129,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.37,
      "electricity": 3.28,
      "site_grid": 2.88,
      "operations": 7.53,
      "total": 51.06,
      "electricity_usd_2026_kwh": 0.129,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.08,
      "electricity": 4.21,
      "site_grid": 2.72,
      "operations": 13.62,
      "total": 67.62,
      "electricity_usd_2026_kwh": 0.129,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.67,
      "electricity": 7.73,
      "site_grid": 6.38,
      "operations": 17.95,
      "total": 114.72,
      "electricity_usd_2026_kwh": 0.129,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.16,
      "electricity": 9.91,
      "site_grid": 6.01,
      "operations": 32.82,
      "total": 152.9,
      "electricity_usd_2026_kwh": 0.129,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.94,
      "electricity": 1.9,
      "site_grid": 1.69,
      "operations": 3.24,
      "total": 24.77,
      "electricity_usd_2026_kwh": 0.203,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.6,
      "electricity": 2.44,
      "site_grid": 1.56,
      "operations": 5.79,
      "total": 32.38,
      "electricity_usd_2026_kwh": 0.203,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.43,
      "electricity": 5.16,
      "site_grid": 3.61,
      "operations": 7.53,
      "total": 54.73,
      "electricity_usd_2026_kwh": 0.203,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.41,
      "electricity": 6.62,
      "site_grid": 3.34,
      "operations": 13.62,
      "total": 71.99,
      "electricity_usd_2026_kwh": 0.203,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.02,
      "electricity": 12.16,
      "site_grid": 7.99,
      "operations": 17.95,
      "total": 123.12,
      "electricity_usd_2026_kwh": 0.203,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.11,
      "electricity": 15.59,
      "site_grid": 7.39,
      "operations": 32.82,
      "total": 162.91,
      "electricity_usd_2026_kwh": 0.203,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.27,
      "electricity": 2.08,
      "site_grid": 1.86,
      "operations": 3.24,
      "total": 25.45,
      "electricity_usd_2026_kwh": 0.2214,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.02,
      "electricity": 2.66,
      "site_grid": 1.7,
      "operations": 5.79,
      "total": 33.16,
      "electricity_usd_2026_kwh": 0.2214,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.15,
      "electricity": 5.63,
      "site_grid": 3.99,
      "operations": 7.53,
      "total": 56.29,
      "electricity_usd_2026_kwh": 0.2214,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.31,
      "electricity": 7.22,
      "site_grid": 3.64,
      "operations": 13.62,
      "total": 73.79,
      "electricity_usd_2026_kwh": 0.2214,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.61,
      "electricity": 13.26,
      "site_grid": 8.82,
      "operations": 17.95,
      "total": 126.63,
      "electricity_usd_2026_kwh": 0.2214,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.1,
      "electricity": 17.0,
      "site_grid": 8.06,
      "operations": 32.82,
      "total": 166.97,
      "electricity_usd_2026_kwh": 0.2214,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.35,
      "electricity": 2.03,
      "site_grid": 1.83,
      "operations": 3.24,
      "total": 25.45,
      "electricity_usd_2026_kwh": 0.216,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.12,
      "electricity": 2.6,
      "site_grid": 1.67,
      "operations": 5.79,
      "total": 33.17,
      "electricity_usd_2026_kwh": 0.216,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.33,
      "electricity": 5.49,
      "site_grid": 3.92,
      "operations": 7.53,
      "total": 56.27,
      "electricity_usd_2026_kwh": 0.216,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.53,
      "electricity": 7.04,
      "site_grid": 3.57,
      "operations": 13.62,
      "total": 73.77,
      "electricity_usd_2026_kwh": 0.216,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.0,
      "electricity": 12.94,
      "site_grid": 8.67,
      "operations": 17.95,
      "total": 126.56,
      "electricity_usd_2026_kwh": 0.216,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.59,
      "electricity": 16.59,
      "site_grid": 7.9,
      "operations": 32.82,
      "total": 166.9,
      "electricity_usd_2026_kwh": 0.216,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.38,
      "electricity": 2.0,
      "site_grid": 1.82,
      "operations": 3.24,
      "total": 25.44,
      "electricity_usd_2026_kwh": 0.2128,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.16,
      "electricity": 2.56,
      "site_grid": 1.65,
      "operations": 5.79,
      "total": 33.15,
      "electricity_usd_2026_kwh": 0.2128,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.39,
      "electricity": 5.41,
      "site_grid": 3.89,
      "operations": 7.53,
      "total": 56.22,
      "electricity_usd_2026_kwh": 0.2128,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.61,
      "electricity": 6.94,
      "site_grid": 3.54,
      "operations": 13.62,
      "total": 73.71,
      "electricity_usd_2026_kwh": 0.2128,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.14,
      "electricity": 12.75,
      "site_grid": 8.61,
      "operations": 17.95,
      "total": 126.44,
      "electricity_usd_2026_kwh": 0.2128,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.76,
      "electricity": 16.34,
      "site_grid": 7.83,
      "operations": 32.82,
      "total": 166.75,
      "electricity_usd_2026_kwh": 0.2128,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.4,
      "electricity": 1.96,
      "site_grid": 1.83,
      "operations": 3.24,
      "total": 25.43,
      "electricity_usd_2026_kwh": 0.2093,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.17,
      "electricity": 2.52,
      "site_grid": 1.66,
      "operations": 5.79,
      "total": 33.14,
      "electricity_usd_2026_kwh": 0.2093,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.41,
      "electricity": 5.32,
      "site_grid": 3.91,
      "operations": 7.53,
      "total": 56.17,
      "electricity_usd_2026_kwh": 0.2093,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.65,
      "electricity": 6.82,
      "site_grid": 3.56,
      "operations": 13.62,
      "total": 73.64,
      "electricity_usd_2026_kwh": 0.2093,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.2,
      "electricity": 12.53,
      "site_grid": 8.65,
      "operations": 17.95,
      "total": 126.33,
      "electricity_usd_2026_kwh": 0.2093,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.83,
      "electricity": 16.07,
      "site_grid": 7.87,
      "operations": 32.82,
      "total": 166.59,
      "electricity_usd_2026_kwh": 0.2093,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.83,
      "electricity": 1.74,
      "site_grid": 1.37,
      "operations": 3.27,
      "total": 23.21,
      "electricity_usd_2026_kwh": 0.1912,
      "wacc": 0.0538,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.16,
      "electricity": 2.23,
      "site_grid": 1.39,
      "operations": 6.49,
      "total": 31.27,
      "electricity_usd_2026_kwh": 0.1912,
      "wacc": 0.0538,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.07,
      "electricity": 4.72,
      "site_grid": 2.93,
      "operations": 7.58,
      "total": 51.3,
      "electricity_usd_2026_kwh": 0.1912,
      "wacc": 0.0538,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.33,
      "electricity": 6.05,
      "site_grid": 2.98,
      "operations": 15.12,
      "total": 69.47,
      "electricity_usd_2026_kwh": 0.1912,
      "wacc": 0.0538,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.79,
      "electricity": 11.12,
      "site_grid": 6.48,
      "operations": 18.06,
      "total": 115.46,
      "electricity_usd_2026_kwh": 0.1912,
      "wacc": 0.0538,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.29,
      "electricity": 14.24,
      "site_grid": 6.58,
      "operations": 36.13,
      "total": 157.24,
      "electricity_usd_2026_kwh": 0.1912,
      "wacc": 0.0538,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.7,
      "electricity": 1.79,
      "site_grid": 1.31,
      "operations": 3.27,
      "total": 23.06,
      "electricity_usd_2026_kwh": 0.1963,
      "wacc": 0.0495,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.99,
      "electricity": 2.29,
      "site_grid": 1.34,
      "operations": 6.49,
      "total": 31.1,
      "electricity_usd_2026_kwh": 0.1963,
      "wacc": 0.0495,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.77,
      "electricity": 4.85,
      "site_grid": 2.81,
      "operations": 7.58,
      "total": 51.01,
      "electricity_usd_2026_kwh": 0.1963,
      "wacc": 0.0495,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.97,
      "electricity": 6.21,
      "site_grid": 2.87,
      "operations": 15.12,
      "total": 69.15,
      "electricity_usd_2026_kwh": 0.1963,
      "wacc": 0.0495,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.15,
      "electricity": 11.42,
      "site_grid": 6.21,
      "operations": 18.06,
      "total": 114.82,
      "electricity_usd_2026_kwh": 0.1963,
      "wacc": 0.0495,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.49,
      "electricity": 14.61,
      "site_grid": 6.34,
      "operations": 36.13,
      "total": 156.56,
      "electricity_usd_2026_kwh": 0.1963,
      "wacc": 0.0495,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.4,
      "electricity": 1.65,
      "site_grid": 1.23,
      "operations": 3.27,
      "total": 22.54,
      "electricity_usd_2026_kwh": 0.1812,
      "wacc": 0.0397,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.6,
      "electricity": 2.11,
      "site_grid": 1.27,
      "operations": 6.49,
      "total": 30.48,
      "electricity_usd_2026_kwh": 0.1812,
      "wacc": 0.0397,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.13,
      "electricity": 4.48,
      "site_grid": 2.64,
      "operations": 7.58,
      "total": 49.82,
      "electricity_usd_2026_kwh": 0.1812,
      "wacc": 0.0397,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.15,
      "electricity": 5.73,
      "site_grid": 2.72,
      "operations": 15.12,
      "total": 67.71,
      "electricity_usd_2026_kwh": 0.1812,
      "wacc": 0.0397,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.73,
      "electricity": 10.54,
      "site_grid": 5.83,
      "operations": 18.06,
      "total": 112.16,
      "electricity_usd_2026_kwh": 0.1812,
      "wacc": 0.0397,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 97.66,
      "electricity": 13.49,
      "site_grid": 6.03,
      "operations": 36.13,
      "total": 153.31,
      "electricity_usd_2026_kwh": 0.1812,
      "wacc": 0.0397,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.56,
      "electricity": 1.74,
      "site_grid": 1.29,
      "operations": 3.27,
      "total": 22.85,
      "electricity_usd_2026_kwh": 0.1908,
      "wacc": 0.0452,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.82,
      "electricity": 2.22,
      "site_grid": 1.32,
      "operations": 6.49,
      "total": 30.86,
      "electricity_usd_2026_kwh": 0.1908,
      "wacc": 0.0452,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.48,
      "electricity": 4.71,
      "site_grid": 2.76,
      "operations": 7.58,
      "total": 50.53,
      "electricity_usd_2026_kwh": 0.1908,
      "wacc": 0.0452,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.6,
      "electricity": 6.03,
      "site_grid": 2.83,
      "operations": 15.12,
      "total": 68.59,
      "electricity_usd_2026_kwh": 0.1908,
      "wacc": 0.0452,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.5,
      "electricity": 11.1,
      "site_grid": 6.1,
      "operations": 18.06,
      "total": 113.76,
      "electricity_usd_2026_kwh": 0.1908,
      "wacc": 0.0452,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.68,
      "electricity": 14.21,
      "site_grid": 6.27,
      "operations": 36.13,
      "total": 155.28,
      "electricity_usd_2026_kwh": 0.1908,
      "wacc": 0.0452,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.62,
      "electricity": 1.62,
      "site_grid": 1.33,
      "operations": 3.27,
      "total": 22.83,
      "electricity_usd_2026_kwh": 0.1773,
      "wacc": 0.0471,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.89,
      "electricity": 2.07,
      "site_grid": 1.36,
      "operations": 6.49,
      "total": 30.81,
      "electricity_usd_2026_kwh": 0.1773,
      "wacc": 0.0471,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.61,
      "electricity": 4.38,
      "site_grid": 2.84,
      "operations": 7.58,
      "total": 50.41,
      "electricity_usd_2026_kwh": 0.1773,
      "wacc": 0.0471,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.76,
      "electricity": 5.61,
      "site_grid": 2.91,
      "operations": 15.12,
      "total": 68.4,
      "electricity_usd_2026_kwh": 0.1773,
      "wacc": 0.0471,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.78,
      "electricity": 10.31,
      "site_grid": 6.28,
      "operations": 18.06,
      "total": 113.44,
      "electricity_usd_2026_kwh": 0.1773,
      "wacc": 0.0471,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.03,
      "electricity": 13.2,
      "site_grid": 6.44,
      "operations": 36.13,
      "total": 154.8,
      "electricity_usd_2026_kwh": 0.1773,
      "wacc": 0.0471,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.49,
      "electricity": 1.27,
      "site_grid": 1.31,
      "operations": 3.27,
      "total": 22.34,
      "electricity_usd_2026_kwh": 0.1392,
      "wacc": 0.0431,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.74,
      "electricity": 1.62,
      "site_grid": 1.35,
      "operations": 6.49,
      "total": 30.2,
      "electricity_usd_2026_kwh": 0.1392,
      "wacc": 0.0431,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.34,
      "electricity": 3.44,
      "site_grid": 2.81,
      "operations": 7.58,
      "total": 49.17,
      "electricity_usd_2026_kwh": 0.1392,
      "wacc": 0.0431,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.43,
      "electricity": 4.4,
      "site_grid": 2.9,
      "operations": 15.12,
      "total": 66.84,
      "electricity_usd_2026_kwh": 0.1392,
      "wacc": 0.0431,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.19,
      "electricity": 8.09,
      "site_grid": 6.22,
      "operations": 18.06,
      "total": 110.55,
      "electricity_usd_2026_kwh": 0.1392,
      "wacc": 0.0431,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.29,
      "electricity": 10.36,
      "site_grid": 6.41,
      "operations": 36.13,
      "total": 151.18,
      "electricity_usd_2026_kwh": 0.1392,
      "wacc": 0.0431,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.4,
      "electricity": 1.31,
      "site_grid": 1.28,
      "operations": 3.27,
      "total": 22.25,
      "electricity_usd_2026_kwh": 0.1436,
      "wacc": 0.0401,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.62,
      "electricity": 1.67,
      "site_grid": 1.32,
      "operations": 6.49,
      "total": 30.1,
      "electricity_usd_2026_kwh": 0.1436,
      "wacc": 0.0401,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.14,
      "electricity": 3.55,
      "site_grid": 2.73,
      "operations": 7.58,
      "total": 49.0,
      "electricity_usd_2026_kwh": 0.1436,
      "wacc": 0.0401,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.17,
      "electricity": 4.54,
      "site_grid": 2.83,
      "operations": 15.12,
      "total": 66.66,
      "electricity_usd_2026_kwh": 0.1436,
      "wacc": 0.0401,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.74,
      "electricity": 8.35,
      "site_grid": 6.05,
      "operations": 18.06,
      "total": 110.19,
      "electricity_usd_2026_kwh": 0.1436,
      "wacc": 0.0401,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 97.73,
      "electricity": 10.69,
      "site_grid": 6.26,
      "operations": 36.13,
      "total": 150.8,
      "electricity_usd_2026_kwh": 0.1436,
      "wacc": 0.0401,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.55,
      "electricity": 1.17,
      "site_grid": 1.33,
      "operations": 3.27,
      "total": 22.32,
      "electricity_usd_2026_kwh": 0.1288,
      "wacc": 0.045,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.81,
      "electricity": 1.5,
      "site_grid": 1.36,
      "operations": 6.49,
      "total": 30.16,
      "electricity_usd_2026_kwh": 0.1288,
      "wacc": 0.045,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.47,
      "electricity": 3.18,
      "site_grid": 2.84,
      "operations": 7.58,
      "total": 49.07,
      "electricity_usd_2026_kwh": 0.1288,
      "wacc": 0.045,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.59,
      "electricity": 4.07,
      "site_grid": 2.92,
      "operations": 15.12,
      "total": 66.7,
      "electricity_usd_2026_kwh": 0.1288,
      "wacc": 0.045,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.47,
      "electricity": 7.49,
      "site_grid": 6.29,
      "operations": 18.06,
      "total": 110.31,
      "electricity_usd_2026_kwh": 0.1288,
      "wacc": 0.045,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.64,
      "electricity": 9.59,
      "site_grid": 6.46,
      "operations": 36.13,
      "total": 150.82,
      "electricity_usd_2026_kwh": 0.1288,
      "wacc": 0.045,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.74,
      "electricity": 1.13,
      "site_grid": 1.41,
      "operations": 3.27,
      "total": 22.55,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.0508,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.04,
      "electricity": 1.45,
      "site_grid": 1.44,
      "operations": 6.49,
      "total": 30.41,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.0508,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.86,
      "electricity": 3.06,
      "site_grid": 3.03,
      "operations": 7.58,
      "total": 49.53,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.0508,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.08,
      "electricity": 3.92,
      "site_grid": 3.09,
      "operations": 15.12,
      "total": 67.2,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.0508,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.34,
      "electricity": 7.21,
      "site_grid": 6.7,
      "operations": 18.06,
      "total": 111.3,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.0508,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.73,
      "electricity": 9.23,
      "site_grid": 6.83,
      "operations": 36.13,
      "total": 151.91,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.0508,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.5,
      "electricity": 0.92,
      "site_grid": 1.39,
      "operations": 3.27,
      "total": 22.07,
      "electricity_usd_2026_kwh": 0.1005,
      "wacc": 0.0431,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.74,
      "electricity": 1.17,
      "site_grid": 1.43,
      "operations": 6.49,
      "total": 29.83,
      "electricity_usd_2026_kwh": 0.1005,
      "wacc": 0.0431,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.34,
      "electricity": 2.48,
      "site_grid": 2.98,
      "operations": 7.58,
      "total": 48.39,
      "electricity_usd_2026_kwh": 0.1005,
      "wacc": 0.0431,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.43,
      "electricity": 3.18,
      "site_grid": 3.07,
      "operations": 15.12,
      "total": 65.79,
      "electricity_usd_2026_kwh": 0.1005,
      "wacc": 0.0431,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.19,
      "electricity": 5.85,
      "site_grid": 6.6,
      "operations": 18.06,
      "total": 108.69,
      "electricity_usd_2026_kwh": 0.1005,
      "wacc": 0.0431,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.29,
      "electricity": 7.48,
      "site_grid": 6.8,
      "operations": 36.13,
      "total": 148.7,
      "electricity_usd_2026_kwh": 0.1005,
      "wacc": 0.0431,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.4,
      "electricity": 0.86,
      "site_grid": 1.38,
      "operations": 3.27,
      "total": 21.91,
      "electricity_usd_2026_kwh": 0.0946,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.42,
      "electricity": 1.1,
      "site_grid": 1.39,
      "operations": 6.49,
      "total": 29.4,
      "electricity_usd_2026_kwh": 0.0946,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.13,
      "electricity": 2.34,
      "site_grid": 2.97,
      "operations": 7.58,
      "total": 48.02,
      "electricity_usd_2026_kwh": 0.0946,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 43.75,
      "electricity": 2.99,
      "site_grid": 2.98,
      "operations": 15.12,
      "total": 64.84,
      "electricity_usd_2026_kwh": 0.0946,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.73,
      "electricity": 5.5,
      "site_grid": 6.56,
      "operations": 18.06,
      "total": 107.85,
      "electricity_usd_2026_kwh": 0.0946,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 96.79,
      "electricity": 7.05,
      "site_grid": 6.6,
      "operations": 36.13,
      "total": 146.56,
      "electricity_usd_2026_kwh": 0.0946,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.4,
      "electricity": 1.29,
      "site_grid": 1.39,
      "operations": 3.27,
      "total": 22.34,
      "electricity_usd_2026_kwh": 0.1415,
      "wacc": 0.0362,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.47,
      "electricity": 1.65,
      "site_grid": 1.41,
      "operations": 6.49,
      "total": 30.01,
      "electricity_usd_2026_kwh": 0.1415,
      "wacc": 0.0362,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.13,
      "electricity": 3.49,
      "site_grid": 2.98,
      "operations": 7.58,
      "total": 49.19,
      "electricity_usd_2026_kwh": 0.1415,
      "wacc": 0.0362,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 43.85,
      "electricity": 4.47,
      "site_grid": 3.02,
      "operations": 15.12,
      "total": 66.45,
      "electricity_usd_2026_kwh": 0.1415,
      "wacc": 0.0362,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.73,
      "electricity": 8.23,
      "site_grid": 6.6,
      "operations": 18.06,
      "total": 110.61,
      "electricity_usd_2026_kwh": 0.1415,
      "wacc": 0.0362,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 97.01,
      "electricity": 10.53,
      "site_grid": 6.68,
      "operations": 36.13,
      "total": 150.34,
      "electricity_usd_2026_kwh": 0.1415,
      "wacc": 0.0362,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.75,
      "electricity": 2.11,
      "site_grid": 1.71,
      "operations": 3.27,
      "total": 23.83,
      "electricity_usd_2026_kwh": 0.2312,
      "wacc": 0.0512,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.05,
      "electricity": 2.7,
      "site_grid": 1.74,
      "operations": 6.49,
      "total": 31.98,
      "electricity_usd_2026_kwh": 0.2312,
      "wacc": 0.0512,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.89,
      "electricity": 5.71,
      "site_grid": 3.66,
      "operations": 7.58,
      "total": 52.83,
      "electricity_usd_2026_kwh": 0.2312,
      "wacc": 0.0512,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.11,
      "electricity": 7.31,
      "site_grid": 3.73,
      "operations": 15.12,
      "total": 71.26,
      "electricity_usd_2026_kwh": 0.2312,
      "wacc": 0.0512,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.4,
      "electricity": 13.45,
      "site_grid": 8.09,
      "operations": 18.06,
      "total": 118.99,
      "electricity_usd_2026_kwh": 0.2312,
      "wacc": 0.0512,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.8,
      "electricity": 17.21,
      "site_grid": 8.24,
      "operations": 36.13,
      "total": 161.38,
      "electricity_usd_2026_kwh": 0.2312,
      "wacc": 0.0512,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.07,
      "electricity": 1.34,
      "site_grid": 1.89,
      "operations": 3.27,
      "total": 23.56,
      "electricity_usd_2026_kwh": 0.1473,
      "wacc": 0.0613,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.45,
      "electricity": 1.72,
      "site_grid": 1.9,
      "operations": 6.49,
      "total": 31.56,
      "electricity_usd_2026_kwh": 0.1473,
      "wacc": 0.0613,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.57,
      "electricity": 3.64,
      "site_grid": 4.05,
      "operations": 7.58,
      "total": 51.83,
      "electricity_usd_2026_kwh": 0.1473,
      "wacc": 0.0613,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.96,
      "electricity": 4.66,
      "site_grid": 4.07,
      "operations": 15.12,
      "total": 69.8,
      "electricity_usd_2026_kwh": 0.1473,
      "wacc": 0.0613,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.91,
      "electricity": 8.56,
      "site_grid": 8.95,
      "operations": 18.06,
      "total": 116.48,
      "electricity_usd_2026_kwh": 0.1473,
      "wacc": 0.0613,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.69,
      "electricity": 10.96,
      "site_grid": 9.0,
      "operations": 36.13,
      "total": 157.78,
      "electricity_usd_2026_kwh": 0.1473,
      "wacc": 0.0613,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.15,
      "electricity": 1.21,
      "site_grid": 1.86,
      "operations": 3.27,
      "total": 23.49,
      "electricity_usd_2026_kwh": 0.1333,
      "wacc": 0.0638,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.55,
      "electricity": 1.55,
      "site_grid": 1.86,
      "operations": 6.49,
      "total": 31.46,
      "electricity_usd_2026_kwh": 0.1333,
      "wacc": 0.0638,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.74,
      "electricity": 3.29,
      "site_grid": 3.98,
      "operations": 7.58,
      "total": 51.6,
      "electricity_usd_2026_kwh": 0.1333,
      "wacc": 0.0638,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.18,
      "electricity": 4.22,
      "site_grid": 3.99,
      "operations": 15.12,
      "total": 69.5,
      "electricity_usd_2026_kwh": 0.1333,
      "wacc": 0.0638,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.28,
      "electricity": 7.75,
      "site_grid": 8.81,
      "operations": 18.06,
      "total": 115.91,
      "electricity_usd_2026_kwh": 0.1333,
      "wacc": 0.0638,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.16,
      "electricity": 9.93,
      "site_grid": 8.84,
      "operations": 36.13,
      "total": 157.04,
      "electricity_usd_2026_kwh": 0.1333,
      "wacc": 0.0638,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.18,
      "electricity": 1.3,
      "site_grid": 1.85,
      "operations": 3.27,
      "total": 23.58,
      "electricity_usd_2026_kwh": 0.1422,
      "wacc": 0.0646,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.59,
      "electricity": 1.66,
      "site_grid": 1.85,
      "operations": 6.49,
      "total": 31.58,
      "electricity_usd_2026_kwh": 0.1422,
      "wacc": 0.0646,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.8,
      "electricity": 3.51,
      "site_grid": 3.95,
      "operations": 7.58,
      "total": 51.84,
      "electricity_usd_2026_kwh": 0.1422,
      "wacc": 0.0646,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.25,
      "electricity": 4.5,
      "site_grid": 3.96,
      "operations": 15.12,
      "total": 69.82,
      "electricity_usd_2026_kwh": 0.1422,
      "wacc": 0.0646,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.41,
      "electricity": 8.27,
      "site_grid": 8.75,
      "operations": 18.06,
      "total": 116.49,
      "electricity_usd_2026_kwh": 0.1422,
      "wacc": 0.0646,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.32,
      "electricity": 10.59,
      "site_grid": 8.76,
      "operations": 36.13,
      "total": 157.79,
      "electricity_usd_2026_kwh": 0.1422,
      "wacc": 0.0646,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.19,
      "electricity": 1.27,
      "site_grid": 1.86,
      "operations": 3.27,
      "total": 23.58,
      "electricity_usd_2026_kwh": 0.1394,
      "wacc": 0.065,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.6,
      "electricity": 1.63,
      "site_grid": 1.86,
      "operations": 6.49,
      "total": 31.57,
      "electricity_usd_2026_kwh": 0.1394,
      "wacc": 0.065,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.82,
      "electricity": 3.44,
      "site_grid": 3.98,
      "operations": 7.58,
      "total": 51.82,
      "electricity_usd_2026_kwh": 0.1394,
      "wacc": 0.065,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.28,
      "electricity": 4.41,
      "site_grid": 3.98,
      "operations": 15.12,
      "total": 69.78,
      "electricity_usd_2026_kwh": 0.1394,
      "wacc": 0.065,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.47,
      "electricity": 8.11,
      "site_grid": 8.79,
      "operations": 18.06,
      "total": 116.43,
      "electricity_usd_2026_kwh": 0.1394,
      "wacc": 0.065,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.39,
      "electricity": 10.38,
      "site_grid": 8.8,
      "operations": 36.13,
      "total": 157.7,
      "electricity_usd_2026_kwh": 0.1394,
      "wacc": 0.065,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.2,
      "electricity": 1.3,
      "site_grid": 1.31,
      "operations": 3.24,
      "total": 24.05,
      "electricity_usd_2026_kwh": 0.1428,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.95,
      "electricity": 1.67,
      "site_grid": 1.19,
      "operations": 5.74,
      "total": 31.55,
      "electricity_usd_2026_kwh": 0.1428,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.0,
      "electricity": 3.53,
      "site_grid": 2.8,
      "operations": 7.52,
      "total": 52.86,
      "electricity_usd_2026_kwh": 0.1428,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.16,
      "electricity": 4.54,
      "site_grid": 2.55,
      "operations": 13.51,
      "total": 69.76,
      "electricity_usd_2026_kwh": 0.1428,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.28,
      "electricity": 8.32,
      "site_grid": 6.2,
      "operations": 17.94,
      "total": 118.74,
      "electricity_usd_2026_kwh": 0.1428,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.76,
      "electricity": 10.69,
      "site_grid": 5.64,
      "operations": 32.6,
      "total": 157.68,
      "electricity_usd_2026_kwh": 0.1428,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.06,
      "electricity": 1.37,
      "site_grid": 1.25,
      "operations": 3.24,
      "total": 23.92,
      "electricity_usd_2026_kwh": 0.1503,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.76,
      "electricity": 1.76,
      "site_grid": 1.15,
      "operations": 5.74,
      "total": 31.41,
      "electricity_usd_2026_kwh": 0.1503,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.69,
      "electricity": 3.72,
      "site_grid": 2.69,
      "operations": 7.52,
      "total": 52.62,
      "electricity_usd_2026_kwh": 0.1503,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.77,
      "electricity": 4.77,
      "site_grid": 2.46,
      "operations": 13.51,
      "total": 69.52,
      "electricity_usd_2026_kwh": 0.1503,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.6,
      "electricity": 8.76,
      "site_grid": 5.94,
      "operations": 17.94,
      "total": 118.23,
      "electricity_usd_2026_kwh": 0.1503,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.9,
      "electricity": 11.24,
      "site_grid": 5.43,
      "operations": 32.6,
      "total": 157.18,
      "electricity_usd_2026_kwh": 0.1503,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.73,
      "electricity": 1.35,
      "site_grid": 1.18,
      "operations": 3.24,
      "total": 23.5,
      "electricity_usd_2026_kwh": 0.1482,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.36,
      "electricity": 1.74,
      "site_grid": 1.09,
      "operations": 5.74,
      "total": 30.92,
      "electricity_usd_2026_kwh": 0.1482,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.99,
      "electricity": 3.67,
      "site_grid": 2.53,
      "operations": 7.52,
      "total": 51.71,
      "electricity_usd_2026_kwh": 0.1482,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.9,
      "electricity": 4.71,
      "site_grid": 2.34,
      "operations": 13.51,
      "total": 68.46,
      "electricity_usd_2026_kwh": 0.1482,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.05,
      "electricity": 8.64,
      "site_grid": 5.59,
      "operations": 17.94,
      "total": 116.22,
      "electricity_usd_2026_kwh": 0.1482,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.96,
      "electricity": 11.09,
      "site_grid": 5.18,
      "operations": 32.6,
      "total": 154.83,
      "electricity_usd_2026_kwh": 0.1482,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.91,
      "electricity": 1.67,
      "site_grid": 1.24,
      "operations": 3.24,
      "total": 24.06,
      "electricity_usd_2026_kwh": 0.1832,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.58,
      "electricity": 2.15,
      "site_grid": 1.14,
      "operations": 5.74,
      "total": 31.6,
      "electricity_usd_2026_kwh": 0.1832,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.38,
      "electricity": 4.53,
      "site_grid": 2.65,
      "operations": 7.52,
      "total": 53.08,
      "electricity_usd_2026_kwh": 0.1832,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.39,
      "electricity": 5.82,
      "site_grid": 2.43,
      "operations": 13.51,
      "total": 70.15,
      "electricity_usd_2026_kwh": 0.1832,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.91,
      "electricity": 10.67,
      "site_grid": 5.85,
      "operations": 17.94,
      "total": 119.38,
      "electricity_usd_2026_kwh": 0.1832,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.05,
      "electricity": 13.71,
      "site_grid": 5.38,
      "operations": 32.6,
      "total": 158.73,
      "electricity_usd_2026_kwh": 0.1832,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.98,
      "electricity": 1.56,
      "site_grid": 1.27,
      "operations": 3.24,
      "total": 24.05,
      "electricity_usd_2026_kwh": 0.1714,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.66,
      "electricity": 2.01,
      "site_grid": 1.17,
      "operations": 5.74,
      "total": 31.58,
      "electricity_usd_2026_kwh": 0.1714,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.52,
      "electricity": 4.24,
      "site_grid": 2.72,
      "operations": 7.52,
      "total": 53.0,
      "electricity_usd_2026_kwh": 0.1714,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.56,
      "electricity": 5.45,
      "site_grid": 2.5,
      "operations": 13.51,
      "total": 70.01,
      "electricity_usd_2026_kwh": 0.1714,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.21,
      "electricity": 9.99,
      "site_grid": 6.02,
      "operations": 17.94,
      "total": 119.16,
      "electricity_usd_2026_kwh": 0.1714,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.42,
      "electricity": 12.82,
      "site_grid": 5.52,
      "operations": 32.6,
      "total": 158.37,
      "electricity_usd_2026_kwh": 0.1714,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.84,
      "electricity": 1.31,
      "site_grid": 1.26,
      "operations": 3.24,
      "total": 23.65,
      "electricity_usd_2026_kwh": 0.143,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.49,
      "electricity": 1.68,
      "site_grid": 1.16,
      "operations": 5.74,
      "total": 31.07,
      "electricity_usd_2026_kwh": 0.143,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.23,
      "electricity": 3.54,
      "site_grid": 2.7,
      "operations": 7.52,
      "total": 51.99,
      "electricity_usd_2026_kwh": 0.143,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.2,
      "electricity": 4.54,
      "site_grid": 2.49,
      "operations": 13.51,
      "total": 68.74,
      "electricity_usd_2026_kwh": 0.143,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.58,
      "electricity": 8.33,
      "site_grid": 5.97,
      "operations": 17.94,
      "total": 116.81,
      "electricity_usd_2026_kwh": 0.143,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.63,
      "electricity": 10.7,
      "site_grid": 5.5,
      "operations": 32.6,
      "total": 155.42,
      "electricity_usd_2026_kwh": 0.143,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.74,
      "electricity": 1.23,
      "site_grid": 1.23,
      "operations": 3.24,
      "total": 23.44,
      "electricity_usd_2026_kwh": 0.1352,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.37,
      "electricity": 1.58,
      "site_grid": 1.13,
      "operations": 5.74,
      "total": 30.83,
      "electricity_usd_2026_kwh": 0.1352,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.02,
      "electricity": 3.35,
      "site_grid": 2.63,
      "operations": 7.52,
      "total": 51.51,
      "electricity_usd_2026_kwh": 0.1352,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.93,
      "electricity": 4.3,
      "site_grid": 2.43,
      "operations": 13.51,
      "total": 68.17,
      "electricity_usd_2026_kwh": 0.1352,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.1,
      "electricity": 7.88,
      "site_grid": 5.81,
      "operations": 17.94,
      "total": 115.73,
      "electricity_usd_2026_kwh": 0.1352,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.03,
      "electricity": 10.12,
      "site_grid": 5.38,
      "operations": 32.6,
      "total": 154.12,
      "electricity_usd_2026_kwh": 0.1352,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.91,
      "electricity": 1.19,
      "site_grid": 1.27,
      "operations": 3.24,
      "total": 23.61,
      "electricity_usd_2026_kwh": 0.1307,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.57,
      "electricity": 1.53,
      "site_grid": 1.17,
      "operations": 5.74,
      "total": 31.02,
      "electricity_usd_2026_kwh": 0.1307,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.37,
      "electricity": 3.24,
      "site_grid": 2.73,
      "operations": 7.52,
      "total": 51.85,
      "electricity_usd_2026_kwh": 0.1307,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.37,
      "electricity": 4.15,
      "site_grid": 2.51,
      "operations": 13.51,
      "total": 68.54,
      "electricity_usd_2026_kwh": 0.1307,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.88,
      "electricity": 7.62,
      "site_grid": 6.03,
      "operations": 17.94,
      "total": 116.47,
      "electricity_usd_2026_kwh": 0.1307,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.0,
      "electricity": 9.78,
      "site_grid": 5.54,
      "operations": 32.6,
      "total": 154.93,
      "electricity_usd_2026_kwh": 0.1307,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.1,
      "electricity": 1.27,
      "site_grid": 1.35,
      "operations": 3.24,
      "total": 23.96,
      "electricity_usd_2026_kwh": 0.1391,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.82,
      "electricity": 1.63,
      "site_grid": 1.23,
      "operations": 5.74,
      "total": 31.42,
      "electricity_usd_2026_kwh": 0.1391,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.78,
      "electricity": 3.44,
      "site_grid": 2.9,
      "operations": 7.52,
      "total": 52.64,
      "electricity_usd_2026_kwh": 0.1391,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.89,
      "electricity": 4.42,
      "site_grid": 2.64,
      "operations": 13.51,
      "total": 69.47,
      "electricity_usd_2026_kwh": 0.1391,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.8,
      "electricity": 8.1,
      "site_grid": 6.41,
      "operations": 17.94,
      "total": 118.25,
      "electricity_usd_2026_kwh": 0.1391,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.16,
      "electricity": 10.41,
      "site_grid": 5.85,
      "operations": 32.6,
      "total": 157.01,
      "electricity_usd_2026_kwh": 0.1391,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.84,
      "electricity": 1.21,
      "site_grid": 1.34,
      "operations": 3.24,
      "total": 23.63,
      "electricity_usd_2026_kwh": 0.1326,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.5,
      "electricity": 1.55,
      "site_grid": 1.23,
      "operations": 5.74,
      "total": 31.02,
      "electricity_usd_2026_kwh": 0.1326,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.23,
      "electricity": 3.28,
      "site_grid": 2.86,
      "operations": 7.52,
      "total": 51.9,
      "electricity_usd_2026_kwh": 0.1326,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.2,
      "electricity": 4.21,
      "site_grid": 2.64,
      "operations": 13.51,
      "total": 68.57,
      "electricity_usd_2026_kwh": 0.1326,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.58,
      "electricity": 7.73,
      "site_grid": 6.33,
      "operations": 17.94,
      "total": 116.58,
      "electricity_usd_2026_kwh": 0.1326,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.63,
      "electricity": 9.93,
      "site_grid": 5.84,
      "operations": 32.6,
      "total": 154.99,
      "electricity_usd_2026_kwh": 0.1326,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.43,
      "electricity": 1.13,
      "site_grid": 1.25,
      "operations": 3.24,
      "total": 23.04,
      "electricity_usd_2026_kwh": 0.1237,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.98,
      "electricity": 1.45,
      "site_grid": 1.17,
      "operations": 5.74,
      "total": 30.33,
      "electricity_usd_2026_kwh": 0.1237,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.34,
      "electricity": 3.06,
      "site_grid": 2.67,
      "operations": 7.52,
      "total": 50.6,
      "electricity_usd_2026_kwh": 0.1237,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.08,
      "electricity": 3.93,
      "site_grid": 2.5,
      "operations": 13.51,
      "total": 67.03,
      "electricity_usd_2026_kwh": 0.1237,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.61,
      "electricity": 7.21,
      "site_grid": 5.91,
      "operations": 17.94,
      "total": 113.66,
      "electricity_usd_2026_kwh": 0.1237,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.17,
      "electricity": 9.25,
      "site_grid": 5.53,
      "operations": 32.6,
      "total": 151.55,
      "electricity_usd_2026_kwh": 0.1237,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.61,
      "electricity": 1.64,
      "site_grid": 1.3,
      "operations": 3.24,
      "total": 23.79,
      "electricity_usd_2026_kwh": 0.1792,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.21,
      "electricity": 2.1,
      "site_grid": 1.21,
      "operations": 5.74,
      "total": 31.26,
      "electricity_usd_2026_kwh": 0.1792,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.74,
      "electricity": 4.43,
      "site_grid": 2.79,
      "operations": 7.52,
      "total": 52.49,
      "electricity_usd_2026_kwh": 0.1792,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.58,
      "electricity": 5.69,
      "site_grid": 2.59,
      "operations": 13.51,
      "total": 69.38,
      "electricity_usd_2026_kwh": 0.1792,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.49,
      "electricity": 10.44,
      "site_grid": 6.17,
      "operations": 17.94,
      "total": 118.04,
      "electricity_usd_2026_kwh": 0.1792,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.26,
      "electricity": 13.41,
      "site_grid": 5.74,
      "operations": 32.6,
      "total": 157.01,
      "electricity_usd_2026_kwh": 0.1792,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.11,
      "electricity": 2.29,
      "site_grid": 1.63,
      "operations": 3.24,
      "total": 25.27,
      "electricity_usd_2026_kwh": 0.2504,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.83,
      "electricity": 2.94,
      "site_grid": 1.49,
      "operations": 5.74,
      "total": 33.0,
      "electricity_usd_2026_kwh": 0.2504,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.81,
      "electricity": 6.2,
      "site_grid": 3.5,
      "operations": 7.52,
      "total": 56.03,
      "electricity_usd_2026_kwh": 0.2504,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.92,
      "electricity": 7.96,
      "site_grid": 3.19,
      "operations": 13.51,
      "total": 73.59,
      "electricity_usd_2026_kwh": 0.2504,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.86,
      "electricity": 14.6,
      "site_grid": 7.74,
      "operations": 17.94,
      "total": 126.14,
      "electricity_usd_2026_kwh": 0.2504,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.24,
      "electricity": 18.74,
      "site_grid": 7.06,
      "operations": 32.6,
      "total": 166.64,
      "electricity_usd_2026_kwh": 0.2504,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.45,
      "electricity": 1.68,
      "site_grid": 1.8,
      "operations": 3.24,
      "total": 25.17,
      "electricity_usd_2026_kwh": 0.1841,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.26,
      "electricity": 2.16,
      "site_grid": 1.62,
      "operations": 5.74,
      "total": 32.78,
      "electricity_usd_2026_kwh": 0.1841,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.54,
      "electricity": 4.56,
      "site_grid": 3.86,
      "operations": 7.52,
      "total": 55.47,
      "electricity_usd_2026_kwh": 0.1841,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.83,
      "electricity": 5.85,
      "site_grid": 3.48,
      "operations": 13.51,
      "total": 72.68,
      "electricity_usd_2026_kwh": 0.1841,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.47,
      "electricity": 10.73,
      "site_grid": 8.54,
      "operations": 17.94,
      "total": 124.67,
      "electricity_usd_2026_kwh": 0.1841,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.25,
      "electricity": 13.78,
      "site_grid": 7.7,
      "operations": 32.6,
      "total": 164.32,
      "electricity_usd_2026_kwh": 0.1841,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.54,
      "electricity": 1.52,
      "site_grid": 1.77,
      "operations": 3.24,
      "total": 25.06,
      "electricity_usd_2026_kwh": 0.1661,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.36,
      "electricity": 1.95,
      "site_grid": 1.59,
      "operations": 5.74,
      "total": 32.64,
      "electricity_usd_2026_kwh": 0.1661,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.72,
      "electricity": 4.11,
      "site_grid": 3.8,
      "operations": 7.52,
      "total": 55.14,
      "electricity_usd_2026_kwh": 0.1661,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.06,
      "electricity": 5.28,
      "site_grid": 3.41,
      "operations": 13.51,
      "total": 72.26,
      "electricity_usd_2026_kwh": 0.1661,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.87,
      "electricity": 9.68,
      "site_grid": 8.4,
      "operations": 17.94,
      "total": 123.88,
      "electricity_usd_2026_kwh": 0.1661,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.74,
      "electricity": 12.43,
      "site_grid": 7.55,
      "operations": 32.6,
      "total": 163.32,
      "electricity_usd_2026_kwh": 0.1661,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.57,
      "electricity": 1.51,
      "site_grid": 1.76,
      "operations": 3.24,
      "total": 25.07,
      "electricity_usd_2026_kwh": 0.165,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.4,
      "electricity": 1.93,
      "site_grid": 1.58,
      "operations": 5.74,
      "total": 32.65,
      "electricity_usd_2026_kwh": 0.165,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.78,
      "electricity": 4.08,
      "site_grid": 3.77,
      "operations": 7.52,
      "total": 55.15,
      "electricity_usd_2026_kwh": 0.165,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.13,
      "electricity": 5.24,
      "site_grid": 3.38,
      "operations": 13.51,
      "total": 72.28,
      "electricity_usd_2026_kwh": 0.165,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.0,
      "electricity": 9.62,
      "site_grid": 8.33,
      "operations": 17.94,
      "total": 123.89,
      "electricity_usd_2026_kwh": 0.165,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.91,
      "electricity": 12.35,
      "site_grid": 7.49,
      "operations": 32.6,
      "total": 163.35,
      "electricity_usd_2026_kwh": 0.165,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.58,
      "electricity": 1.48,
      "site_grid": 1.77,
      "operations": 3.24,
      "total": 25.06,
      "electricity_usd_2026_kwh": 0.1617,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.42,
      "electricity": 1.9,
      "site_grid": 1.59,
      "operations": 5.74,
      "total": 32.64,
      "electricity_usd_2026_kwh": 0.1617,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.8,
      "electricity": 4.0,
      "site_grid": 3.79,
      "operations": 7.52,
      "total": 55.11,
      "electricity_usd_2026_kwh": 0.1617,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.17,
      "electricity": 5.14,
      "site_grid": 3.4,
      "operations": 13.51,
      "total": 72.22,
      "electricity_usd_2026_kwh": 0.1617,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.06,
      "electricity": 9.42,
      "site_grid": 8.37,
      "operations": 17.94,
      "total": 123.8,
      "electricity_usd_2026_kwh": 0.1617,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.99,
      "electricity": 12.1,
      "site_grid": 7.52,
      "operations": 32.6,
      "total": 163.21,
      "electricity_usd_2026_kwh": 0.1617,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.74,
      "electricity": 1.26,
      "site_grid": 1.2,
      "operations": 3.2,
      "total": 22.4,
      "electricity_usd_2026_kwh": 0.1383,
      "wacc": 0.0508,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.04,
      "electricity": 1.58,
      "site_grid": 1.12,
      "operations": 6.12,
      "total": 29.87,
      "electricity_usd_2026_kwh": 0.1383,
      "wacc": 0.0508,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.86,
      "electricity": 3.41,
      "site_grid": 2.57,
      "operations": 7.45,
      "total": 49.3,
      "electricity_usd_2026_kwh": 0.1383,
      "wacc": 0.0508,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.08,
      "electricity": 4.29,
      "site_grid": 2.41,
      "operations": 14.33,
      "total": 66.11,
      "electricity_usd_2026_kwh": 0.1383,
      "wacc": 0.0508,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.34,
      "electricity": 8.04,
      "site_grid": 5.69,
      "operations": 17.77,
      "total": 110.85,
      "electricity_usd_2026_kwh": 0.1383,
      "wacc": 0.0508,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.73,
      "electricity": 10.11,
      "site_grid": 5.32,
      "operations": 34.38,
      "total": 149.55,
      "electricity_usd_2026_kwh": 0.1383,
      "wacc": 0.0508,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.6,
      "electricity": 1.4,
      "site_grid": 1.15,
      "operations": 3.2,
      "total": 22.36,
      "electricity_usd_2026_kwh": 0.154,
      "wacc": 0.0465,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.87,
      "electricity": 1.76,
      "site_grid": 1.08,
      "operations": 6.12,
      "total": 29.84,
      "electricity_usd_2026_kwh": 0.154,
      "wacc": 0.0465,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.57,
      "electricity": 3.8,
      "site_grid": 2.46,
      "operations": 7.45,
      "total": 49.29,
      "electricity_usd_2026_kwh": 0.154,
      "wacc": 0.0465,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.72,
      "electricity": 4.78,
      "site_grid": 2.32,
      "operations": 14.33,
      "total": 66.14,
      "electricity_usd_2026_kwh": 0.154,
      "wacc": 0.0465,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.7,
      "electricity": 8.96,
      "site_grid": 5.45,
      "operations": 17.77,
      "total": 110.87,
      "electricity_usd_2026_kwh": 0.154,
      "wacc": 0.0465,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.93,
      "electricity": 11.26,
      "site_grid": 5.13,
      "operations": 34.38,
      "total": 149.69,
      "electricity_usd_2026_kwh": 0.154,
      "wacc": 0.0465,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.4,
      "electricity": 1.26,
      "site_grid": 1.1,
      "operations": 3.2,
      "total": 21.97,
      "electricity_usd_2026_kwh": 0.1387,
      "wacc": 0.0367,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.49,
      "electricity": 1.59,
      "site_grid": 1.03,
      "operations": 6.12,
      "total": 29.22,
      "electricity_usd_2026_kwh": 0.1387,
      "wacc": 0.0367,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.13,
      "electricity": 3.42,
      "site_grid": 2.36,
      "operations": 7.45,
      "total": 48.37,
      "electricity_usd_2026_kwh": 0.1387,
      "wacc": 0.0367,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 43.89,
      "electricity": 4.3,
      "site_grid": 2.2,
      "operations": 14.33,
      "total": 64.73,
      "electricity_usd_2026_kwh": 0.1387,
      "wacc": 0.0367,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.73,
      "electricity": 8.06,
      "site_grid": 5.23,
      "operations": 17.77,
      "total": 108.79,
      "electricity_usd_2026_kwh": 0.1387,
      "wacc": 0.0367,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 97.11,
      "electricity": 10.14,
      "site_grid": 4.87,
      "operations": 34.38,
      "total": 146.5,
      "electricity_usd_2026_kwh": 0.1387,
      "wacc": 0.0367,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.47,
      "electricity": 1.29,
      "site_grid": 1.13,
      "operations": 3.2,
      "total": 22.09,
      "electricity_usd_2026_kwh": 0.1411,
      "wacc": 0.0422,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.7,
      "electricity": 1.62,
      "site_grid": 1.07,
      "operations": 6.12,
      "total": 29.51,
      "electricity_usd_2026_kwh": 0.1411,
      "wacc": 0.0422,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.28,
      "electricity": 3.49,
      "site_grid": 2.42,
      "operations": 7.45,
      "total": 48.64,
      "electricity_usd_2026_kwh": 0.1411,
      "wacc": 0.0422,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.35,
      "electricity": 4.38,
      "site_grid": 2.29,
      "operations": 14.33,
      "total": 65.35,
      "electricity_usd_2026_kwh": 0.1411,
      "wacc": 0.0422,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.05,
      "electricity": 8.21,
      "site_grid": 5.36,
      "operations": 17.77,
      "total": 109.39,
      "electricity_usd_2026_kwh": 0.1411,
      "wacc": 0.0422,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.12,
      "electricity": 10.32,
      "site_grid": 5.07,
      "operations": 34.38,
      "total": 147.89,
      "electricity_usd_2026_kwh": 0.1411,
      "wacc": 0.0422,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.53,
      "electricity": 1.23,
      "site_grid": 1.16,
      "operations": 3.2,
      "total": 22.13,
      "electricity_usd_2026_kwh": 0.1351,
      "wacc": 0.0441,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.78,
      "electricity": 1.55,
      "site_grid": 1.1,
      "operations": 6.12,
      "total": 29.54,
      "electricity_usd_2026_kwh": 0.1351,
      "wacc": 0.0441,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.41,
      "electricity": 3.34,
      "site_grid": 2.49,
      "operations": 7.45,
      "total": 48.69,
      "electricity_usd_2026_kwh": 0.1351,
      "wacc": 0.0441,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.51,
      "electricity": 4.19,
      "site_grid": 2.35,
      "operations": 14.33,
      "total": 65.38,
      "electricity_usd_2026_kwh": 0.1351,
      "wacc": 0.0441,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.34,
      "electricity": 7.86,
      "site_grid": 5.52,
      "operations": 17.77,
      "total": 109.48,
      "electricity_usd_2026_kwh": 0.1351,
      "wacc": 0.0441,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.48,
      "electricity": 9.88,
      "site_grid": 5.21,
      "operations": 34.38,
      "total": 147.94,
      "electricity_usd_2026_kwh": 0.1351,
      "wacc": 0.0441,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.4,
      "electricity": 1.0,
      "site_grid": 1.15,
      "operations": 3.2,
      "total": 21.75,
      "electricity_usd_2026_kwh": 0.1094,
      "wacc": 0.0401,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.62,
      "electricity": 1.25,
      "site_grid": 1.09,
      "operations": 6.12,
      "total": 29.08,
      "electricity_usd_2026_kwh": 0.1094,
      "wacc": 0.0401,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.14,
      "electricity": 2.7,
      "site_grid": 2.47,
      "operations": 7.45,
      "total": 47.75,
      "electricity_usd_2026_kwh": 0.1094,
      "wacc": 0.0401,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.17,
      "electricity": 3.39,
      "site_grid": 2.34,
      "operations": 14.33,
      "total": 64.24,
      "electricity_usd_2026_kwh": 0.1094,
      "wacc": 0.0401,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.74,
      "electricity": 6.36,
      "site_grid": 5.46,
      "operations": 17.77,
      "total": 107.32,
      "electricity_usd_2026_kwh": 0.1094,
      "wacc": 0.0401,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 97.73,
      "electricity": 8.0,
      "site_grid": 5.18,
      "operations": 34.38,
      "total": 145.28,
      "electricity_usd_2026_kwh": 0.1094,
      "wacc": 0.0401,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.4,
      "electricity": 0.96,
      "site_grid": 1.14,
      "operations": 3.2,
      "total": 21.7,
      "electricity_usd_2026_kwh": 0.1051,
      "wacc": 0.0371,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.5,
      "electricity": 1.2,
      "site_grid": 1.07,
      "operations": 6.12,
      "total": 28.89,
      "electricity_usd_2026_kwh": 0.1051,
      "wacc": 0.0371,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.13,
      "electricity": 2.6,
      "site_grid": 2.45,
      "operations": 7.45,
      "total": 47.63,
      "electricity_usd_2026_kwh": 0.1051,
      "wacc": 0.0371,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 43.92,
      "electricity": 3.26,
      "site_grid": 2.29,
      "operations": 14.33,
      "total": 63.8,
      "electricity_usd_2026_kwh": 0.1051,
      "wacc": 0.0371,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.73,
      "electricity": 6.11,
      "site_grid": 5.42,
      "operations": 17.77,
      "total": 107.03,
      "electricity_usd_2026_kwh": 0.1051,
      "wacc": 0.0371,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 97.17,
      "electricity": 7.68,
      "site_grid": 5.06,
      "operations": 34.38,
      "total": 144.29,
      "electricity_usd_2026_kwh": 0.1051,
      "wacc": 0.0371,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.46,
      "electricity": 0.93,
      "site_grid": 1.16,
      "operations": 3.2,
      "total": 21.76,
      "electricity_usd_2026_kwh": 0.1023,
      "wacc": 0.042,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.69,
      "electricity": 1.17,
      "site_grid": 1.1,
      "operations": 6.12,
      "total": 29.09,
      "electricity_usd_2026_kwh": 0.1023,
      "wacc": 0.042,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.27,
      "electricity": 2.53,
      "site_grid": 2.49,
      "operations": 7.45,
      "total": 47.74,
      "electricity_usd_2026_kwh": 0.1023,
      "wacc": 0.042,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.33,
      "electricity": 3.18,
      "site_grid": 2.36,
      "operations": 14.33,
      "total": 64.2,
      "electricity_usd_2026_kwh": 0.1023,
      "wacc": 0.042,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.02,
      "electricity": 5.95,
      "site_grid": 5.52,
      "operations": 17.77,
      "total": 107.26,
      "electricity_usd_2026_kwh": 0.1023,
      "wacc": 0.042,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.08,
      "electricity": 7.48,
      "site_grid": 5.22,
      "operations": 34.38,
      "total": 145.17,
      "electricity_usd_2026_kwh": 0.1023,
      "wacc": 0.042,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.64,
      "electricity": 0.98,
      "site_grid": 1.24,
      "operations": 3.2,
      "total": 22.07,
      "electricity_usd_2026_kwh": 0.1079,
      "wacc": 0.0478,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.92,
      "electricity": 1.24,
      "site_grid": 1.16,
      "operations": 6.12,
      "total": 29.44,
      "electricity_usd_2026_kwh": 0.1079,
      "wacc": 0.0478,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.66,
      "electricity": 2.66,
      "site_grid": 2.66,
      "operations": 7.45,
      "total": 48.43,
      "electricity_usd_2026_kwh": 0.1079,
      "wacc": 0.0478,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.82,
      "electricity": 3.35,
      "site_grid": 2.5,
      "operations": 14.33,
      "total": 64.99,
      "electricity_usd_2026_kwh": 0.1079,
      "wacc": 0.0478,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.89,
      "electricity": 6.28,
      "site_grid": 5.88,
      "operations": 17.77,
      "total": 108.81,
      "electricity_usd_2026_kwh": 0.1079,
      "wacc": 0.0478,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.17,
      "electricity": 7.89,
      "site_grid": 5.52,
      "operations": 34.38,
      "total": 146.95,
      "electricity_usd_2026_kwh": 0.1079,
      "wacc": 0.0478,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.4,
      "electricity": 0.94,
      "site_grid": 1.22,
      "operations": 3.2,
      "total": 21.77,
      "electricity_usd_2026_kwh": 0.1035,
      "wacc": 0.0401,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.62,
      "electricity": 1.19,
      "site_grid": 1.16,
      "operations": 6.12,
      "total": 29.08,
      "electricity_usd_2026_kwh": 0.1035,
      "wacc": 0.0401,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.14,
      "electricity": 2.56,
      "site_grid": 2.62,
      "operations": 7.45,
      "total": 47.76,
      "electricity_usd_2026_kwh": 0.1035,
      "wacc": 0.0401,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.18,
      "electricity": 3.21,
      "site_grid": 2.48,
      "operations": 14.33,
      "total": 64.2,
      "electricity_usd_2026_kwh": 0.1035,
      "wacc": 0.0401,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.74,
      "electricity": 6.02,
      "site_grid": 5.79,
      "operations": 17.77,
      "total": 107.32,
      "electricity_usd_2026_kwh": 0.1035,
      "wacc": 0.0401,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 97.74,
      "electricity": 7.57,
      "site_grid": 5.5,
      "operations": 34.38,
      "total": 145.18,
      "electricity_usd_2026_kwh": 0.1035,
      "wacc": 0.0401,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.4,
      "electricity": 0.97,
      "site_grid": 1.24,
      "operations": 3.2,
      "total": 21.81,
      "electricity_usd_2026_kwh": 0.106,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.42,
      "electricity": 1.21,
      "site_grid": 1.14,
      "operations": 6.12,
      "total": 28.9,
      "electricity_usd_2026_kwh": 0.106,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.13,
      "electricity": 2.62,
      "site_grid": 2.66,
      "operations": 7.45,
      "total": 47.86,
      "electricity_usd_2026_kwh": 0.106,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 43.75,
      "electricity": 3.29,
      "site_grid": 2.45,
      "operations": 14.33,
      "total": 63.82,
      "electricity_usd_2026_kwh": 0.106,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.73,
      "electricity": 6.17,
      "site_grid": 5.88,
      "operations": 17.77,
      "total": 107.55,
      "electricity_usd_2026_kwh": 0.106,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 96.79,
      "electricity": 7.75,
      "site_grid": 5.43,
      "operations": 34.38,
      "total": 144.35,
      "electricity_usd_2026_kwh": 0.106,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.4,
      "electricity": 0.97,
      "site_grid": 1.25,
      "operations": 3.2,
      "total": 21.82,
      "electricity_usd_2026_kwh": 0.1065,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.42,
      "electricity": 1.22,
      "site_grid": 1.15,
      "operations": 6.12,
      "total": 28.91,
      "electricity_usd_2026_kwh": 0.1065,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.13,
      "electricity": 2.63,
      "site_grid": 2.67,
      "operations": 7.45,
      "total": 47.89,
      "electricity_usd_2026_kwh": 0.1065,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 43.75,
      "electricity": 3.31,
      "site_grid": 2.46,
      "operations": 14.33,
      "total": 63.85,
      "electricity_usd_2026_kwh": 0.1065,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.73,
      "electricity": 6.19,
      "site_grid": 5.91,
      "operations": 17.77,
      "total": 107.6,
      "electricity_usd_2026_kwh": 0.1065,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 96.79,
      "electricity": 7.79,
      "site_grid": 5.45,
      "operations": 34.38,
      "total": 144.41,
      "electricity_usd_2026_kwh": 0.1065,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.66,
      "electricity": 1.06,
      "site_grid": 1.5,
      "operations": 3.2,
      "total": 22.42,
      "electricity_usd_2026_kwh": 0.1164,
      "wacc": 0.0482,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.94,
      "electricity": 1.33,
      "site_grid": 1.41,
      "operations": 6.12,
      "total": 29.8,
      "electricity_usd_2026_kwh": 0.1164,
      "wacc": 0.0482,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.69,
      "electricity": 2.88,
      "site_grid": 3.21,
      "operations": 7.45,
      "total": 49.22,
      "electricity_usd_2026_kwh": 0.1164,
      "wacc": 0.0482,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.86,
      "electricity": 3.61,
      "site_grid": 3.01,
      "operations": 14.33,
      "total": 65.81,
      "electricity_usd_2026_kwh": 0.1164,
      "wacc": 0.0482,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.95,
      "electricity": 6.77,
      "site_grid": 7.1,
      "operations": 17.77,
      "total": 110.59,
      "electricity_usd_2026_kwh": 0.1164,
      "wacc": 0.0482,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.24,
      "electricity": 8.51,
      "site_grid": 6.66,
      "operations": 34.38,
      "total": 148.8,
      "electricity_usd_2026_kwh": 0.1164,
      "wacc": 0.0482,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.97,
      "electricity": 0.98,
      "site_grid": 1.66,
      "operations": 3.2,
      "total": 22.82,
      "electricity_usd_2026_kwh": 0.1081,
      "wacc": 0.0583,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.33,
      "electricity": 1.24,
      "site_grid": 1.54,
      "operations": 6.12,
      "total": 30.23,
      "electricity_usd_2026_kwh": 0.1081,
      "wacc": 0.0583,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.37,
      "electricity": 2.67,
      "site_grid": 3.55,
      "operations": 7.45,
      "total": 50.04,
      "electricity_usd_2026_kwh": 0.1081,
      "wacc": 0.0583,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.71,
      "electricity": 3.36,
      "site_grid": 3.29,
      "operations": 14.33,
      "total": 66.68,
      "electricity_usd_2026_kwh": 0.1081,
      "wacc": 0.0583,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.46,
      "electricity": 6.29,
      "site_grid": 7.86,
      "operations": 17.77,
      "total": 112.38,
      "electricity_usd_2026_kwh": 0.1081,
      "wacc": 0.0583,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.13,
      "electricity": 7.9,
      "site_grid": 7.28,
      "operations": 34.38,
      "total": 150.69,
      "electricity_usd_2026_kwh": 0.1081,
      "wacc": 0.0583,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.05,
      "electricity": 0.86,
      "site_grid": 1.63,
      "operations": 3.2,
      "total": 22.75,
      "electricity_usd_2026_kwh": 0.0944,
      "wacc": 0.0608,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.43,
      "electricity": 1.08,
      "site_grid": 1.51,
      "operations": 6.12,
      "total": 30.14,
      "electricity_usd_2026_kwh": 0.0944,
      "wacc": 0.0608,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.54,
      "electricity": 2.33,
      "site_grid": 3.5,
      "operations": 7.45,
      "total": 49.82,
      "electricity_usd_2026_kwh": 0.0944,
      "wacc": 0.0608,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.92,
      "electricity": 2.93,
      "site_grid": 3.23,
      "operations": 14.33,
      "total": 66.41,
      "electricity_usd_2026_kwh": 0.0944,
      "wacc": 0.0608,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.83,
      "electricity": 5.49,
      "site_grid": 7.74,
      "operations": 17.77,
      "total": 111.83,
      "electricity_usd_2026_kwh": 0.0944,
      "wacc": 0.0608,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.59,
      "electricity": 6.9,
      "site_grid": 7.15,
      "operations": 34.38,
      "total": 150.02,
      "electricity_usd_2026_kwh": 0.0944,
      "wacc": 0.0608,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.08,
      "electricity": 0.81,
      "site_grid": 1.62,
      "operations": 3.2,
      "total": 22.71,
      "electricity_usd_2026_kwh": 0.0888,
      "wacc": 0.0616,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.47,
      "electricity": 1.02,
      "site_grid": 1.5,
      "operations": 6.12,
      "total": 30.1,
      "electricity_usd_2026_kwh": 0.0888,
      "wacc": 0.0616,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.59,
      "electricity": 2.19,
      "site_grid": 3.47,
      "operations": 7.45,
      "total": 49.71,
      "electricity_usd_2026_kwh": 0.0888,
      "wacc": 0.0616,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.99,
      "electricity": 2.75,
      "site_grid": 3.2,
      "operations": 14.33,
      "total": 66.28,
      "electricity_usd_2026_kwh": 0.0888,
      "wacc": 0.0616,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.96,
      "electricity": 5.16,
      "site_grid": 7.69,
      "operations": 17.77,
      "total": 111.57,
      "electricity_usd_2026_kwh": 0.0888,
      "wacc": 0.0616,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.75,
      "electricity": 6.49,
      "site_grid": 7.09,
      "operations": 34.38,
      "total": 149.71,
      "electricity_usd_2026_kwh": 0.0888,
      "wacc": 0.0616,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.09,
      "electricity": 0.78,
      "site_grid": 1.63,
      "operations": 3.2,
      "total": 22.71,
      "electricity_usd_2026_kwh": 0.0858,
      "wacc": 0.062,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.48,
      "electricity": 0.98,
      "site_grid": 1.5,
      "operations": 6.12,
      "total": 30.09,
      "electricity_usd_2026_kwh": 0.0858,
      "wacc": 0.062,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.62,
      "electricity": 2.12,
      "site_grid": 3.49,
      "operations": 7.45,
      "total": 49.68,
      "electricity_usd_2026_kwh": 0.0858,
      "wacc": 0.062,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.03,
      "electricity": 2.66,
      "site_grid": 3.22,
      "operations": 14.33,
      "total": 66.23,
      "electricity_usd_2026_kwh": 0.0858,
      "wacc": 0.062,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.02,
      "electricity": 4.99,
      "site_grid": 7.73,
      "operations": 17.77,
      "total": 111.5,
      "electricity_usd_2026_kwh": 0.0858,
      "wacc": 0.062,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.82,
      "electricity": 6.27,
      "site_grid": 7.12,
      "operations": 34.38,
      "total": 149.6,
      "electricity_usd_2026_kwh": 0.0858,
      "wacc": 0.062,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.1,
      "electricity": 1.41,
      "site_grid": 1.41,
      "operations": 3.27,
      "total": 23.19,
      "electricity_usd_2026_kwh": 0.1501,
      "wacc": 0.0568,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.51,
      "electricity": 1.8,
      "site_grid": 1.44,
      "operations": 6.3,
      "total": 31.05,
      "electricity_usd_2026_kwh": 0.1501,
      "wacc": 0.0568,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.64,
      "electricity": 3.81,
      "site_grid": 3.03,
      "operations": 7.59,
      "total": 51.08,
      "electricity_usd_2026_kwh": 0.1501,
      "wacc": 0.0568,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.09,
      "electricity": 4.88,
      "site_grid": 3.09,
      "operations": 14.71,
      "total": 68.76,
      "electricity_usd_2026_kwh": 0.1501,
      "wacc": 0.0568,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.07,
      "electricity": 8.98,
      "site_grid": 6.7,
      "operations": 18.08,
      "total": 114.83,
      "electricity_usd_2026_kwh": 0.1501,
      "wacc": 0.0568,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.96,
      "electricity": 11.49,
      "site_grid": 6.83,
      "operations": 35.23,
      "total": 155.51,
      "electricity_usd_2026_kwh": 0.1501,
      "wacc": 0.0568,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.96,
      "electricity": 1.59,
      "site_grid": 1.35,
      "operations": 3.27,
      "total": 23.18,
      "electricity_usd_2026_kwh": 0.1695,
      "wacc": 0.0525,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.34,
      "electricity": 2.03,
      "site_grid": 1.39,
      "operations": 6.3,
      "total": 31.06,
      "electricity_usd_2026_kwh": 0.1695,
      "wacc": 0.0525,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.35,
      "electricity": 4.3,
      "site_grid": 2.9,
      "operations": 7.59,
      "total": 51.14,
      "electricity_usd_2026_kwh": 0.1695,
      "wacc": 0.0525,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.71,
      "electricity": 5.51,
      "site_grid": 2.97,
      "operations": 14.71,
      "total": 68.91,
      "electricity_usd_2026_kwh": 0.1695,
      "wacc": 0.0525,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.41,
      "electricity": 10.14,
      "site_grid": 6.42,
      "operations": 18.08,
      "total": 115.05,
      "electricity_usd_2026_kwh": 0.1695,
      "wacc": 0.0525,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.14,
      "electricity": 12.98,
      "site_grid": 6.58,
      "operations": 35.23,
      "total": 155.92,
      "electricity_usd_2026_kwh": 0.1695,
      "wacc": 0.0525,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.65,
      "electricity": 1.51,
      "site_grid": 1.27,
      "operations": 3.27,
      "total": 22.71,
      "electricity_usd_2026_kwh": 0.1613,
      "wacc": 0.0427,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.95,
      "electricity": 1.93,
      "site_grid": 1.32,
      "operations": 6.3,
      "total": 30.5,
      "electricity_usd_2026_kwh": 0.1613,
      "wacc": 0.0427,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.68,
      "electricity": 4.1,
      "site_grid": 2.72,
      "operations": 7.59,
      "total": 50.09,
      "electricity_usd_2026_kwh": 0.1613,
      "wacc": 0.0427,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.88,
      "electricity": 5.24,
      "site_grid": 2.83,
      "operations": 14.71,
      "total": 67.66,
      "electricity_usd_2026_kwh": 0.1613,
      "wacc": 0.0427,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.94,
      "electricity": 9.65,
      "site_grid": 6.02,
      "operations": 18.08,
      "total": 112.69,
      "electricity_usd_2026_kwh": 0.1613,
      "wacc": 0.0427,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.29,
      "electricity": 12.35,
      "site_grid": 6.25,
      "operations": 35.23,
      "total": 153.13,
      "electricity_usd_2026_kwh": 0.1613,
      "wacc": 0.0427,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.83,
      "electricity": 1.61,
      "site_grid": 1.33,
      "operations": 3.27,
      "total": 23.04,
      "electricity_usd_2026_kwh": 0.1718,
      "wacc": 0.0482,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.17,
      "electricity": 2.06,
      "site_grid": 1.37,
      "operations": 6.3,
      "total": 30.9,
      "electricity_usd_2026_kwh": 0.1718,
      "wacc": 0.0482,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.05,
      "electricity": 4.36,
      "site_grid": 2.85,
      "operations": 7.59,
      "total": 50.86,
      "electricity_usd_2026_kwh": 0.1718,
      "wacc": 0.0482,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.35,
      "electricity": 5.58,
      "site_grid": 2.94,
      "operations": 14.71,
      "total": 68.58,
      "electricity_usd_2026_kwh": 0.1718,
      "wacc": 0.0482,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.76,
      "electricity": 10.27,
      "site_grid": 6.31,
      "operations": 18.08,
      "total": 114.43,
      "electricity_usd_2026_kwh": 0.1718,
      "wacc": 0.0482,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.32,
      "electricity": 13.15,
      "site_grid": 6.5,
      "operations": 35.23,
      "total": 155.21,
      "electricity_usd_2026_kwh": 0.1718,
      "wacc": 0.0482,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.89,
      "electricity": 1.67,
      "site_grid": 1.37,
      "operations": 3.27,
      "total": 23.2,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.0501,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.24,
      "electricity": 2.14,
      "site_grid": 1.41,
      "operations": 6.3,
      "total": 31.09,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.0501,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.18,
      "electricity": 4.53,
      "site_grid": 2.94,
      "operations": 7.59,
      "total": 51.24,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.0501,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.51,
      "electricity": 5.8,
      "site_grid": 3.02,
      "operations": 14.71,
      "total": 69.04,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.0501,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.05,
      "electricity": 10.68,
      "site_grid": 6.5,
      "operations": 18.08,
      "total": 115.31,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.0501,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.68,
      "electricity": 13.67,
      "site_grid": 6.68,
      "operations": 35.23,
      "total": 156.26,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.0501,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.76,
      "electricity": 1.43,
      "site_grid": 1.36,
      "operations": 3.27,
      "total": 22.82,
      "electricity_usd_2026_kwh": 0.1531,
      "wacc": 0.0461,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.08,
      "electricity": 1.84,
      "site_grid": 1.4,
      "operations": 6.3,
      "total": 30.62,
      "electricity_usd_2026_kwh": 0.1531,
      "wacc": 0.0461,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.91,
      "electricity": 3.89,
      "site_grid": 2.91,
      "operations": 7.59,
      "total": 50.29,
      "electricity_usd_2026_kwh": 0.1531,
      "wacc": 0.0461,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.17,
      "electricity": 4.98,
      "site_grid": 3.0,
      "operations": 14.71,
      "total": 67.86,
      "electricity_usd_2026_kwh": 0.1531,
      "wacc": 0.0461,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.44,
      "electricity": 9.16,
      "site_grid": 6.43,
      "operations": 18.08,
      "total": 113.11,
      "electricity_usd_2026_kwh": 0.1531,
      "wacc": 0.0461,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.92,
      "electricity": 11.72,
      "site_grid": 6.65,
      "operations": 35.23,
      "total": 153.53,
      "electricity_usd_2026_kwh": 0.1531,
      "wacc": 0.0461,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.66,
      "electricity": 1.33,
      "site_grid": 1.32,
      "operations": 3.27,
      "total": 22.59,
      "electricity_usd_2026_kwh": 0.1422,
      "wacc": 0.0431,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.96,
      "electricity": 1.7,
      "site_grid": 1.37,
      "operations": 6.3,
      "total": 30.34,
      "electricity_usd_2026_kwh": 0.1422,
      "wacc": 0.0431,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.7,
      "electricity": 3.61,
      "site_grid": 2.83,
      "operations": 7.59,
      "total": 49.73,
      "electricity_usd_2026_kwh": 0.1422,
      "wacc": 0.0431,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.91,
      "electricity": 4.62,
      "site_grid": 2.93,
      "operations": 14.71,
      "total": 67.18,
      "electricity_usd_2026_kwh": 0.1422,
      "wacc": 0.0431,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.99,
      "electricity": 8.5,
      "site_grid": 6.25,
      "operations": 18.08,
      "total": 111.83,
      "electricity_usd_2026_kwh": 0.1422,
      "wacc": 0.0431,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.36,
      "electricity": 10.88,
      "site_grid": 6.49,
      "operations": 35.23,
      "total": 151.97,
      "electricity_usd_2026_kwh": 0.1422,
      "wacc": 0.0431,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.82,
      "electricity": 1.35,
      "site_grid": 1.37,
      "operations": 3.27,
      "total": 22.82,
      "electricity_usd_2026_kwh": 0.1446,
      "wacc": 0.048,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.16,
      "electricity": 1.73,
      "site_grid": 1.41,
      "operations": 6.3,
      "total": 30.6,
      "electricity_usd_2026_kwh": 0.1446,
      "wacc": 0.048,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.04,
      "electricity": 3.67,
      "site_grid": 2.94,
      "operations": 7.59,
      "total": 50.24,
      "electricity_usd_2026_kwh": 0.1446,
      "wacc": 0.048,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.33,
      "electricity": 4.7,
      "site_grid": 3.03,
      "operations": 14.71,
      "total": 67.77,
      "electricity_usd_2026_kwh": 0.1446,
      "wacc": 0.048,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.73,
      "electricity": 8.65,
      "site_grid": 6.5,
      "operations": 18.08,
      "total": 112.96,
      "electricity_usd_2026_kwh": 0.1446,
      "wacc": 0.048,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.28,
      "electricity": 11.07,
      "site_grid": 6.7,
      "operations": 35.23,
      "total": 153.29,
      "electricity_usd_2026_kwh": 0.1446,
      "wacc": 0.048,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.01,
      "electricity": 1.36,
      "site_grid": 1.46,
      "operations": 3.27,
      "total": 23.1,
      "electricity_usd_2026_kwh": 0.1454,
      "wacc": 0.0538,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.39,
      "electricity": 1.74,
      "site_grid": 1.49,
      "operations": 6.3,
      "total": 30.93,
      "electricity_usd_2026_kwh": 0.1454,
      "wacc": 0.0538,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.44,
      "electricity": 3.69,
      "site_grid": 3.13,
      "operations": 7.59,
      "total": 50.85,
      "electricity_usd_2026_kwh": 0.1454,
      "wacc": 0.0538,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.83,
      "electricity": 4.73,
      "site_grid": 3.2,
      "operations": 14.71,
      "total": 68.46,
      "electricity_usd_2026_kwh": 0.1454,
      "wacc": 0.0538,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.61,
      "electricity": 8.7,
      "site_grid": 6.92,
      "operations": 18.08,
      "total": 114.31,
      "electricity_usd_2026_kwh": 0.1454,
      "wacc": 0.0538,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.38,
      "electricity": 11.14,
      "site_grid": 7.08,
      "operations": 35.23,
      "total": 154.83,
      "electricity_usd_2026_kwh": 0.1454,
      "wacc": 0.0538,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.76,
      "electricity": 1.34,
      "site_grid": 1.44,
      "operations": 3.27,
      "total": 22.81,
      "electricity_usd_2026_kwh": 0.1429,
      "wacc": 0.0461,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.08,
      "electricity": 1.71,
      "site_grid": 1.49,
      "operations": 6.3,
      "total": 30.58,
      "electricity_usd_2026_kwh": 0.1429,
      "wacc": 0.0461,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.91,
      "electricity": 3.63,
      "site_grid": 3.08,
      "operations": 7.59,
      "total": 50.22,
      "electricity_usd_2026_kwh": 0.1429,
      "wacc": 0.0461,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.17,
      "electricity": 4.65,
      "site_grid": 3.19,
      "operations": 14.71,
      "total": 67.71,
      "electricity_usd_2026_kwh": 0.1429,
      "wacc": 0.0461,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.45,
      "electricity": 8.55,
      "site_grid": 6.82,
      "operations": 18.08,
      "total": 112.9,
      "electricity_usd_2026_kwh": 0.1429,
      "wacc": 0.0461,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.93,
      "electricity": 10.94,
      "site_grid": 7.05,
      "operations": 35.23,
      "total": 153.16,
      "electricity_usd_2026_kwh": 0.1429,
      "wacc": 0.0461,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.57,
      "electricity": 1.37,
      "site_grid": 1.4,
      "operations": 3.27,
      "total": 22.61,
      "electricity_usd_2026_kwh": 0.1466,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.64,
      "electricity": 1.76,
      "site_grid": 1.42,
      "operations": 6.3,
      "total": 30.12,
      "electricity_usd_2026_kwh": 0.1466,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.5,
      "electricity": 3.72,
      "site_grid": 3.0,
      "operations": 7.59,
      "total": 49.81,
      "electricity_usd_2026_kwh": 0.1466,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.23,
      "electricity": 4.77,
      "site_grid": 3.04,
      "operations": 14.71,
      "total": 66.75,
      "electricity_usd_2026_kwh": 0.1466,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.53,
      "electricity": 8.77,
      "site_grid": 6.64,
      "operations": 18.08,
      "total": 112.03,
      "electricity_usd_2026_kwh": 0.1466,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 97.85,
      "electricity": 11.23,
      "site_grid": 6.73,
      "operations": 35.23,
      "total": 151.03,
      "electricity_usd_2026_kwh": 0.1466,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.57,
      "electricity": 1.4,
      "site_grid": 1.41,
      "operations": 3.27,
      "total": 22.65,
      "electricity_usd_2026_kwh": 0.1497,
      "wacc": 0.0392,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.81,
      "electricity": 1.8,
      "site_grid": 1.46,
      "operations": 6.3,
      "total": 30.36,
      "electricity_usd_2026_kwh": 0.1497,
      "wacc": 0.0392,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.5,
      "electricity": 3.8,
      "site_grid": 3.02,
      "operations": 7.59,
      "total": 49.91,
      "electricity_usd_2026_kwh": 0.1497,
      "wacc": 0.0392,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.58,
      "electricity": 4.87,
      "site_grid": 3.13,
      "operations": 14.71,
      "total": 67.29,
      "electricity_usd_2026_kwh": 0.1497,
      "wacc": 0.0392,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.53,
      "electricity": 8.96,
      "site_grid": 6.68,
      "operations": 18.08,
      "total": 112.24,
      "electricity_usd_2026_kwh": 0.1497,
      "wacc": 0.0392,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.63,
      "electricity": 11.46,
      "site_grid": 6.93,
      "operations": 35.23,
      "total": 152.25,
      "electricity_usd_2026_kwh": 0.1497,
      "wacc": 0.0392,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.02,
      "electricity": 1.42,
      "site_grid": 1.76,
      "operations": 3.27,
      "total": 23.47,
      "electricity_usd_2026_kwh": 0.1511,
      "wacc": 0.0542,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.4,
      "electricity": 1.81,
      "site_grid": 1.8,
      "operations": 6.3,
      "total": 31.32,
      "electricity_usd_2026_kwh": 0.1511,
      "wacc": 0.0542,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.46,
      "electricity": 3.84,
      "site_grid": 3.78,
      "operations": 7.59,
      "total": 51.67,
      "electricity_usd_2026_kwh": 0.1511,
      "wacc": 0.0542,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.86,
      "electricity": 4.91,
      "site_grid": 3.86,
      "operations": 14.71,
      "total": 69.34,
      "electricity_usd_2026_kwh": 0.1511,
      "wacc": 0.0542,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.67,
      "electricity": 9.04,
      "site_grid": 8.36,
      "operations": 18.08,
      "total": 116.15,
      "electricity_usd_2026_kwh": 0.1511,
      "wacc": 0.0542,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.46,
      "electricity": 11.57,
      "site_grid": 8.55,
      "operations": 35.23,
      "total": 156.8,
      "electricity_usd_2026_kwh": 0.1511,
      "wacc": 0.0542,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.34,
      "electricity": 2.56,
      "site_grid": 1.95,
      "operations": 3.27,
      "total": 25.13,
      "electricity_usd_2026_kwh": 0.2736,
      "wacc": 0.0643,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.81,
      "electricity": 3.28,
      "site_grid": 1.97,
      "operations": 6.3,
      "total": 33.36,
      "electricity_usd_2026_kwh": 0.2736,
      "wacc": 0.0643,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.15,
      "electricity": 6.95,
      "site_grid": 4.18,
      "operations": 7.59,
      "total": 55.87,
      "electricity_usd_2026_kwh": 0.2736,
      "wacc": 0.0643,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.72,
      "electricity": 8.89,
      "site_grid": 4.22,
      "operations": 14.71,
      "total": 74.55,
      "electricity_usd_2026_kwh": 0.2736,
      "wacc": 0.0643,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.2,
      "electricity": 16.37,
      "site_grid": 9.24,
      "operations": 18.08,
      "total": 125.89,
      "electricity_usd_2026_kwh": 0.2736,
      "wacc": 0.0643,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.37,
      "electricity": 20.95,
      "site_grid": 9.33,
      "operations": 35.23,
      "total": 168.88,
      "electricity_usd_2026_kwh": 0.2736,
      "wacc": 0.0643,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.42,
      "electricity": 1.92,
      "site_grid": 1.92,
      "operations": 3.27,
      "total": 24.53,
      "electricity_usd_2026_kwh": 0.2045,
      "wacc": 0.0668,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.91,
      "electricity": 2.45,
      "site_grid": 1.93,
      "operations": 6.3,
      "total": 32.59,
      "electricity_usd_2026_kwh": 0.2045,
      "wacc": 0.0668,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.33,
      "electricity": 5.19,
      "site_grid": 4.11,
      "operations": 7.59,
      "total": 54.22,
      "electricity_usd_2026_kwh": 0.2045,
      "wacc": 0.0668,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.94,
      "electricity": 6.65,
      "site_grid": 4.14,
      "operations": 14.71,
      "total": 72.44,
      "electricity_usd_2026_kwh": 0.2045,
      "wacc": 0.0668,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.58,
      "electricity": 12.23,
      "site_grid": 9.1,
      "operations": 18.08,
      "total": 121.99,
      "electricity_usd_2026_kwh": 0.2045,
      "wacc": 0.0668,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.84,
      "electricity": 15.66,
      "site_grid": 9.16,
      "operations": 35.23,
      "total": 163.89,
      "electricity_usd_2026_kwh": 0.2045,
      "wacc": 0.0668,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.45,
      "electricity": 1.74,
      "site_grid": 1.91,
      "operations": 3.27,
      "total": 24.36,
      "electricity_usd_2026_kwh": 0.1853,
      "wacc": 0.0676,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.94,
      "electricity": 2.22,
      "site_grid": 1.92,
      "operations": 6.3,
      "total": 32.38,
      "electricity_usd_2026_kwh": 0.1853,
      "wacc": 0.0676,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.38,
      "electricity": 4.71,
      "site_grid": 4.08,
      "operations": 7.59,
      "total": 53.77,
      "electricity_usd_2026_kwh": 0.1853,
      "wacc": 0.0676,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.01,
      "electricity": 6.02,
      "site_grid": 4.1,
      "operations": 14.71,
      "total": 71.85,
      "electricity_usd_2026_kwh": 0.1853,
      "wacc": 0.0676,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.71,
      "electricity": 11.09,
      "site_grid": 9.03,
      "operations": 18.08,
      "total": 120.91,
      "electricity_usd_2026_kwh": 0.1853,
      "wacc": 0.0676,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.0,
      "electricity": 14.19,
      "site_grid": 9.08,
      "operations": 35.23,
      "total": 162.51,
      "electricity_usd_2026_kwh": 0.1853,
      "wacc": 0.0676,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.46,
      "electricity": 1.65,
      "site_grid": 1.92,
      "operations": 3.27,
      "total": 24.3,
      "electricity_usd_2026_kwh": 0.1759,
      "wacc": 0.068,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.96,
      "electricity": 2.11,
      "site_grid": 1.92,
      "operations": 6.3,
      "total": 32.29,
      "electricity_usd_2026_kwh": 0.1759,
      "wacc": 0.068,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.41,
      "electricity": 4.47,
      "site_grid": 4.1,
      "operations": 7.59,
      "total": 53.57,
      "electricity_usd_2026_kwh": 0.1759,
      "wacc": 0.068,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.04,
      "electricity": 5.72,
      "site_grid": 4.12,
      "operations": 14.71,
      "total": 71.6,
      "electricity_usd_2026_kwh": 0.1759,
      "wacc": 0.068,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.77,
      "electricity": 10.52,
      "site_grid": 9.08,
      "operations": 18.08,
      "total": 120.45,
      "electricity_usd_2026_kwh": 0.1759,
      "wacc": 0.068,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "FR",
      "country": "France",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.08,
      "electricity": 13.47,
      "site_grid": 9.12,
      "operations": 35.23,
      "total": 161.9,
      "electricity_usd_2026_kwh": 0.1759,
      "wacc": 0.068,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.1,
      "electricity": 2.16,
      "site_grid": 1.5,
      "operations": 3.3,
      "total": 24.06,
      "electricity_usd_2026_kwh": 0.2321,
      "wacc": 0.0568,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.51,
      "electricity": 2.76,
      "site_grid": 1.66,
      "operations": 6.53,
      "total": 32.46,
      "electricity_usd_2026_kwh": 0.2321,
      "wacc": 0.0568,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.64,
      "electricity": 5.84,
      "site_grid": 3.21,
      "operations": 7.66,
      "total": 53.36,
      "electricity_usd_2026_kwh": 0.2321,
      "wacc": 0.0568,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.09,
      "electricity": 7.48,
      "site_grid": 3.57,
      "operations": 15.2,
      "total": 72.33,
      "electricity_usd_2026_kwh": 0.2321,
      "wacc": 0.0568,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.07,
      "electricity": 13.76,
      "site_grid": 7.1,
      "operations": 18.24,
      "total": 120.17,
      "electricity_usd_2026_kwh": 0.2321,
      "wacc": 0.0568,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.96,
      "electricity": 17.62,
      "site_grid": 7.89,
      "operations": 36.31,
      "total": 163.77,
      "electricity_usd_2026_kwh": 0.2321,
      "wacc": 0.0568,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.96,
      "electricity": 2.37,
      "site_grid": 1.43,
      "operations": 3.3,
      "total": 24.07,
      "electricity_usd_2026_kwh": 0.2548,
      "wacc": 0.0525,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.34,
      "electricity": 3.03,
      "site_grid": 1.6,
      "operations": 6.53,
      "total": 32.49,
      "electricity_usd_2026_kwh": 0.2548,
      "wacc": 0.0525,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.35,
      "electricity": 6.41,
      "site_grid": 3.07,
      "operations": 7.66,
      "total": 53.49,
      "electricity_usd_2026_kwh": 0.2548,
      "wacc": 0.0525,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.71,
      "electricity": 8.21,
      "site_grid": 3.44,
      "operations": 15.2,
      "total": 72.56,
      "electricity_usd_2026_kwh": 0.2548,
      "wacc": 0.0525,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.41,
      "electricity": 15.1,
      "site_grid": 6.8,
      "operations": 18.24,
      "total": 120.55,
      "electricity_usd_2026_kwh": 0.2548,
      "wacc": 0.0525,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.14,
      "electricity": 19.33,
      "site_grid": 7.6,
      "operations": 36.31,
      "total": 164.38,
      "electricity_usd_2026_kwh": 0.2548,
      "wacc": 0.0525,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.65,
      "electricity": 2.21,
      "site_grid": 1.35,
      "operations": 3.3,
      "total": 23.51,
      "electricity_usd_2026_kwh": 0.2381,
      "wacc": 0.0427,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.95,
      "electricity": 2.83,
      "site_grid": 1.52,
      "operations": 6.53,
      "total": 31.83,
      "electricity_usd_2026_kwh": 0.2381,
      "wacc": 0.0427,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.68,
      "electricity": 5.99,
      "site_grid": 2.88,
      "operations": 7.66,
      "total": 52.22,
      "electricity_usd_2026_kwh": 0.2381,
      "wacc": 0.0427,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.88,
      "electricity": 7.67,
      "site_grid": 3.27,
      "operations": 15.2,
      "total": 71.02,
      "electricity_usd_2026_kwh": 0.2381,
      "wacc": 0.0427,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.94,
      "electricity": 14.11,
      "site_grid": 6.38,
      "operations": 18.24,
      "total": 117.67,
      "electricity_usd_2026_kwh": 0.2381,
      "wacc": 0.0427,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.29,
      "electricity": 18.07,
      "site_grid": 7.23,
      "operations": 36.31,
      "total": 160.9,
      "electricity_usd_2026_kwh": 0.2381,
      "wacc": 0.0427,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.83,
      "electricity": 2.51,
      "site_grid": 1.41,
      "operations": 3.3,
      "total": 24.05,
      "electricity_usd_2026_kwh": 0.2703,
      "wacc": 0.0482,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.17,
      "electricity": 3.21,
      "site_grid": 1.59,
      "operations": 6.53,
      "total": 32.49,
      "electricity_usd_2026_kwh": 0.2703,
      "wacc": 0.0482,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.05,
      "electricity": 6.8,
      "site_grid": 3.02,
      "operations": 7.66,
      "total": 53.54,
      "electricity_usd_2026_kwh": 0.2703,
      "wacc": 0.0482,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.35,
      "electricity": 8.71,
      "site_grid": 3.4,
      "operations": 15.2,
      "total": 72.65,
      "electricity_usd_2026_kwh": 0.2703,
      "wacc": 0.0482,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.76,
      "electricity": 16.02,
      "site_grid": 6.69,
      "operations": 18.24,
      "total": 120.71,
      "electricity_usd_2026_kwh": 0.2703,
      "wacc": 0.0482,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.32,
      "electricity": 20.51,
      "site_grid": 7.52,
      "operations": 36.31,
      "total": 164.66,
      "electricity_usd_2026_kwh": 0.2703,
      "wacc": 0.0482,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.89,
      "electricity": 2.68,
      "site_grid": 1.45,
      "operations": 3.3,
      "total": 24.32,
      "electricity_usd_2026_kwh": 0.2882,
      "wacc": 0.0501,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.24,
      "electricity": 3.43,
      "site_grid": 1.63,
      "operations": 6.53,
      "total": 32.82,
      "electricity_usd_2026_kwh": 0.2882,
      "wacc": 0.0501,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.18,
      "electricity": 7.25,
      "site_grid": 3.11,
      "operations": 7.66,
      "total": 54.21,
      "electricity_usd_2026_kwh": 0.2882,
      "wacc": 0.0501,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.51,
      "electricity": 9.29,
      "site_grid": 3.49,
      "operations": 15.2,
      "total": 73.48,
      "electricity_usd_2026_kwh": 0.2882,
      "wacc": 0.0501,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.05,
      "electricity": 17.08,
      "site_grid": 6.88,
      "operations": 18.24,
      "total": 122.25,
      "electricity_usd_2026_kwh": 0.2882,
      "wacc": 0.0501,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.68,
      "electricity": 21.87,
      "site_grid": 7.72,
      "operations": 36.31,
      "total": 166.58,
      "electricity_usd_2026_kwh": 0.2882,
      "wacc": 0.0501,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.76,
      "electricity": 2.16,
      "site_grid": 1.44,
      "operations": 3.3,
      "total": 23.66,
      "electricity_usd_2026_kwh": 0.2324,
      "wacc": 0.0461,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.08,
      "electricity": 2.76,
      "site_grid": 1.62,
      "operations": 6.53,
      "total": 31.99,
      "electricity_usd_2026_kwh": 0.2324,
      "wacc": 0.0461,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.91,
      "electricity": 5.85,
      "site_grid": 3.08,
      "operations": 7.66,
      "total": 52.5,
      "electricity_usd_2026_kwh": 0.2324,
      "wacc": 0.0461,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.17,
      "electricity": 7.49,
      "site_grid": 3.47,
      "operations": 15.2,
      "total": 71.32,
      "electricity_usd_2026_kwh": 0.2324,
      "wacc": 0.0461,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.44,
      "electricity": 13.77,
      "site_grid": 6.81,
      "operations": 18.24,
      "total": 118.27,
      "electricity_usd_2026_kwh": 0.2324,
      "wacc": 0.0461,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.92,
      "electricity": 17.63,
      "site_grid": 7.68,
      "operations": 36.31,
      "total": 161.55,
      "electricity_usd_2026_kwh": 0.2324,
      "wacc": 0.0461,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.66,
      "electricity": 2.12,
      "site_grid": 1.4,
      "operations": 3.3,
      "total": 23.49,
      "electricity_usd_2026_kwh": 0.2285,
      "wacc": 0.0431,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.96,
      "electricity": 2.72,
      "site_grid": 1.58,
      "operations": 6.53,
      "total": 31.79,
      "electricity_usd_2026_kwh": 0.2285,
      "wacc": 0.0431,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.7,
      "electricity": 5.75,
      "site_grid": 2.99,
      "operations": 7.66,
      "total": 52.11,
      "electricity_usd_2026_kwh": 0.2285,
      "wacc": 0.0431,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.91,
      "electricity": 7.36,
      "site_grid": 3.39,
      "operations": 15.2,
      "total": 70.86,
      "electricity_usd_2026_kwh": 0.2285,
      "wacc": 0.0431,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.99,
      "electricity": 13.54,
      "site_grid": 6.63,
      "operations": 18.24,
      "total": 117.39,
      "electricity_usd_2026_kwh": 0.2285,
      "wacc": 0.0431,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.36,
      "electricity": 17.34,
      "site_grid": 7.5,
      "operations": 36.31,
      "total": 160.51,
      "electricity_usd_2026_kwh": 0.2285,
      "wacc": 0.0431,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.82,
      "electricity": 2.15,
      "site_grid": 1.45,
      "operations": 3.3,
      "total": 23.72,
      "electricity_usd_2026_kwh": 0.2311,
      "wacc": 0.048,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.16,
      "electricity": 2.75,
      "site_grid": 1.63,
      "operations": 6.53,
      "total": 32.06,
      "electricity_usd_2026_kwh": 0.2311,
      "wacc": 0.048,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.04,
      "electricity": 5.82,
      "site_grid": 3.11,
      "operations": 7.66,
      "total": 52.63,
      "electricity_usd_2026_kwh": 0.2311,
      "wacc": 0.048,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.33,
      "electricity": 7.45,
      "site_grid": 3.5,
      "operations": 15.2,
      "total": 71.47,
      "electricity_usd_2026_kwh": 0.2311,
      "wacc": 0.048,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.73,
      "electricity": 13.7,
      "site_grid": 6.89,
      "operations": 18.24,
      "total": 118.55,
      "electricity_usd_2026_kwh": 0.2311,
      "wacc": 0.048,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.28,
      "electricity": 17.54,
      "site_grid": 7.75,
      "operations": 36.31,
      "total": 161.88,
      "electricity_usd_2026_kwh": 0.2311,
      "wacc": 0.048,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.01,
      "electricity": 2.18,
      "site_grid": 1.55,
      "operations": 3.3,
      "total": 24.03,
      "electricity_usd_2026_kwh": 0.2344,
      "wacc": 0.0538,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.39,
      "electricity": 2.79,
      "site_grid": 1.73,
      "operations": 6.53,
      "total": 32.43,
      "electricity_usd_2026_kwh": 0.2344,
      "wacc": 0.0538,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.44,
      "electricity": 5.9,
      "site_grid": 3.32,
      "operations": 7.66,
      "total": 53.31,
      "electricity_usd_2026_kwh": 0.2344,
      "wacc": 0.0538,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.83,
      "electricity": 7.55,
      "site_grid": 3.7,
      "operations": 15.2,
      "total": 72.27,
      "electricity_usd_2026_kwh": 0.2344,
      "wacc": 0.0538,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.61,
      "electricity": 13.89,
      "site_grid": 7.34,
      "operations": 18.24,
      "total": 120.07,
      "electricity_usd_2026_kwh": 0.2344,
      "wacc": 0.0538,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.38,
      "electricity": 17.78,
      "site_grid": 8.18,
      "operations": 36.31,
      "total": 163.66,
      "electricity_usd_2026_kwh": 0.2344,
      "wacc": 0.0538,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.76,
      "electricity": 2.13,
      "site_grid": 1.53,
      "operations": 3.3,
      "total": 23.72,
      "electricity_usd_2026_kwh": 0.2292,
      "wacc": 0.0461,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.08,
      "electricity": 2.72,
      "site_grid": 1.72,
      "operations": 6.53,
      "total": 32.05,
      "electricity_usd_2026_kwh": 0.2292,
      "wacc": 0.0461,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.91,
      "electricity": 5.77,
      "site_grid": 3.27,
      "operations": 7.66,
      "total": 52.61,
      "electricity_usd_2026_kwh": 0.2292,
      "wacc": 0.0461,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.17,
      "electricity": 7.38,
      "site_grid": 3.69,
      "operations": 15.2,
      "total": 71.44,
      "electricity_usd_2026_kwh": 0.2292,
      "wacc": 0.0461,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.45,
      "electricity": 13.58,
      "site_grid": 7.23,
      "operations": 18.24,
      "total": 118.5,
      "electricity_usd_2026_kwh": 0.2292,
      "wacc": 0.0461,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.93,
      "electricity": 17.39,
      "site_grid": 8.15,
      "operations": 36.31,
      "total": 161.78,
      "electricity_usd_2026_kwh": 0.2292,
      "wacc": 0.0461,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.57,
      "electricity": 2.44,
      "site_grid": 1.48,
      "operations": 3.3,
      "total": 23.79,
      "electricity_usd_2026_kwh": 0.2624,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.64,
      "electricity": 3.12,
      "site_grid": 1.64,
      "operations": 6.53,
      "total": 31.93,
      "electricity_usd_2026_kwh": 0.2624,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.5,
      "electricity": 6.6,
      "site_grid": 3.18,
      "operations": 7.66,
      "total": 52.94,
      "electricity_usd_2026_kwh": 0.2624,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.23,
      "electricity": 8.46,
      "site_grid": 3.51,
      "operations": 15.2,
      "total": 71.4,
      "electricity_usd_2026_kwh": 0.2624,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.53,
      "electricity": 15.55,
      "site_grid": 7.04,
      "operations": 18.24,
      "total": 119.36,
      "electricity_usd_2026_kwh": 0.2624,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 97.85,
      "electricity": 19.91,
      "site_grid": 7.78,
      "operations": 36.31,
      "total": 161.85,
      "electricity_usd_2026_kwh": 0.2624,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.57,
      "electricity": 2.46,
      "site_grid": 1.49,
      "operations": 3.3,
      "total": 23.82,
      "electricity_usd_2026_kwh": 0.265,
      "wacc": 0.0392,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.81,
      "electricity": 3.15,
      "site_grid": 1.69,
      "operations": 6.53,
      "total": 32.17,
      "electricity_usd_2026_kwh": 0.265,
      "wacc": 0.0392,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.5,
      "electricity": 6.67,
      "site_grid": 3.2,
      "operations": 7.66,
      "total": 53.02,
      "electricity_usd_2026_kwh": 0.265,
      "wacc": 0.0392,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.58,
      "electricity": 8.54,
      "site_grid": 3.62,
      "operations": 15.2,
      "total": 71.94,
      "electricity_usd_2026_kwh": 0.265,
      "wacc": 0.0392,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.53,
      "electricity": 15.71,
      "site_grid": 7.07,
      "operations": 18.24,
      "total": 119.55,
      "electricity_usd_2026_kwh": 0.265,
      "wacc": 0.0392,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.63,
      "electricity": 20.11,
      "site_grid": 8.01,
      "operations": 36.31,
      "total": 163.05,
      "electricity_usd_2026_kwh": 0.265,
      "wacc": 0.0392,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.02,
      "electricity": 2.31,
      "site_grid": 1.87,
      "operations": 3.3,
      "total": 24.5,
      "electricity_usd_2026_kwh": 0.2491,
      "wacc": 0.0542,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.4,
      "electricity": 2.96,
      "site_grid": 2.08,
      "operations": 6.53,
      "total": 32.98,
      "electricity_usd_2026_kwh": 0.2491,
      "wacc": 0.0542,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.46,
      "electricity": 6.27,
      "site_grid": 4.0,
      "operations": 7.66,
      "total": 54.4,
      "electricity_usd_2026_kwh": 0.2491,
      "wacc": 0.0542,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.86,
      "electricity": 8.03,
      "site_grid": 4.47,
      "operations": 15.2,
      "total": 73.55,
      "electricity_usd_2026_kwh": 0.2491,
      "wacc": 0.0542,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.67,
      "electricity": 14.76,
      "site_grid": 8.86,
      "operations": 18.24,
      "total": 122.53,
      "electricity_usd_2026_kwh": 0.2491,
      "wacc": 0.0542,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.46,
      "electricity": 18.9,
      "site_grid": 9.88,
      "operations": 36.31,
      "total": 166.55,
      "electricity_usd_2026_kwh": 0.2491,
      "wacc": 0.0542,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.34,
      "electricity": 2.38,
      "site_grid": 2.07,
      "operations": 3.3,
      "total": 25.09,
      "electricity_usd_2026_kwh": 0.2563,
      "wacc": 0.0643,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.81,
      "electricity": 3.05,
      "site_grid": 2.28,
      "operations": 6.53,
      "total": 33.66,
      "electricity_usd_2026_kwh": 0.2563,
      "wacc": 0.0643,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.15,
      "electricity": 6.45,
      "site_grid": 4.43,
      "operations": 7.66,
      "total": 55.7,
      "electricity_usd_2026_kwh": 0.2563,
      "wacc": 0.0643,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.72,
      "electricity": 8.26,
      "site_grid": 4.88,
      "operations": 15.2,
      "total": 75.05,
      "electricity_usd_2026_kwh": 0.2563,
      "wacc": 0.0643,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.2,
      "electricity": 15.19,
      "site_grid": 9.8,
      "operations": 18.24,
      "total": 125.43,
      "electricity_usd_2026_kwh": 0.2563,
      "wacc": 0.0643,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.37,
      "electricity": 19.45,
      "site_grid": 10.79,
      "operations": 36.31,
      "total": 169.91,
      "electricity_usd_2026_kwh": 0.2563,
      "wacc": 0.0643,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.42,
      "electricity": 2.48,
      "site_grid": 2.04,
      "operations": 3.3,
      "total": 25.24,
      "electricity_usd_2026_kwh": 0.2672,
      "wacc": 0.0668,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.91,
      "electricity": 3.18,
      "site_grid": 2.23,
      "operations": 6.53,
      "total": 33.84,
      "electricity_usd_2026_kwh": 0.2672,
      "wacc": 0.0668,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.33,
      "electricity": 6.72,
      "site_grid": 4.36,
      "operations": 7.66,
      "total": 56.07,
      "electricity_usd_2026_kwh": 0.2672,
      "wacc": 0.0668,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.94,
      "electricity": 8.61,
      "site_grid": 4.78,
      "operations": 15.2,
      "total": 75.53,
      "electricity_usd_2026_kwh": 0.2672,
      "wacc": 0.0668,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.58,
      "electricity": 15.84,
      "site_grid": 9.65,
      "operations": 18.24,
      "total": 126.3,
      "electricity_usd_2026_kwh": 0.2672,
      "wacc": 0.0668,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.84,
      "electricity": 20.28,
      "site_grid": 10.58,
      "operations": 36.31,
      "total": 171.01,
      "electricity_usd_2026_kwh": 0.2672,
      "wacc": 0.0668,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.45,
      "electricity": 2.45,
      "site_grid": 2.02,
      "operations": 3.3,
      "total": 25.22,
      "electricity_usd_2026_kwh": 0.2636,
      "wacc": 0.0676,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.94,
      "electricity": 3.13,
      "site_grid": 2.21,
      "operations": 6.53,
      "total": 33.82,
      "electricity_usd_2026_kwh": 0.2636,
      "wacc": 0.0676,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.38,
      "electricity": 6.64,
      "site_grid": 4.33,
      "operations": 7.66,
      "total": 56.01,
      "electricity_usd_2026_kwh": 0.2636,
      "wacc": 0.0676,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.01,
      "electricity": 8.49,
      "site_grid": 4.74,
      "operations": 15.2,
      "total": 75.45,
      "electricity_usd_2026_kwh": 0.2636,
      "wacc": 0.0676,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.71,
      "electricity": 15.63,
      "site_grid": 9.58,
      "operations": 18.24,
      "total": 126.15,
      "electricity_usd_2026_kwh": 0.2636,
      "wacc": 0.0676,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.0,
      "electricity": 20.01,
      "site_grid": 10.5,
      "operations": 36.31,
      "total": 170.82,
      "electricity_usd_2026_kwh": 0.2636,
      "wacc": 0.0676,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.46,
      "electricity": 2.41,
      "site_grid": 2.03,
      "operations": 3.3,
      "total": 25.21,
      "electricity_usd_2026_kwh": 0.2596,
      "wacc": 0.068,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.96,
      "electricity": 3.09,
      "site_grid": 2.22,
      "operations": 6.53,
      "total": 33.79,
      "electricity_usd_2026_kwh": 0.2596,
      "wacc": 0.068,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.41,
      "electricity": 6.53,
      "site_grid": 4.35,
      "operations": 7.66,
      "total": 55.96,
      "electricity_usd_2026_kwh": 0.2596,
      "wacc": 0.068,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.04,
      "electricity": 8.37,
      "site_grid": 4.77,
      "operations": 15.2,
      "total": 75.37,
      "electricity_usd_2026_kwh": 0.2596,
      "wacc": 0.068,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.77,
      "electricity": 15.39,
      "site_grid": 9.63,
      "operations": 18.24,
      "total": 126.02,
      "electricity_usd_2026_kwh": 0.2596,
      "wacc": 0.068,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.08,
      "electricity": 19.7,
      "site_grid": 10.55,
      "operations": 36.31,
      "total": 170.63,
      "electricity_usd_2026_kwh": 0.2596,
      "wacc": 0.068,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.6,
      "electricity": 2.0,
      "site_grid": 1.66,
      "operations": 3.33,
      "total": 26.59,
      "electricity_usd_2026_kwh": 0.1982,
      "wacc": 0.0988,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.75,
      "electricity": 2.56,
      "site_grid": 1.47,
      "operations": 5.73,
      "total": 34.52,
      "electricity_usd_2026_kwh": 0.1982,
      "wacc": 0.0988,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.0,
      "electricity": 5.41,
      "site_grid": 3.57,
      "operations": 7.72,
      "total": 58.7,
      "electricity_usd_2026_kwh": 0.1982,
      "wacc": 0.0988,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.02,
      "electricity": 6.95,
      "site_grid": 3.16,
      "operations": 13.51,
      "total": 76.64,
      "electricity_usd_2026_kwh": 0.1982,
      "wacc": 0.0988,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 92.92,
      "electricity": 12.75,
      "site_grid": 7.89,
      "operations": 18.36,
      "total": 131.93,
      "electricity_usd_2026_kwh": 0.1982,
      "wacc": 0.0988,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 117.3,
      "electricity": 16.36,
      "site_grid": 6.99,
      "operations": 32.59,
      "total": 173.24,
      "electricity_usd_2026_kwh": 0.1982,
      "wacc": 0.0988,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 21.57,
      "electricity": 2.22,
      "site_grid": 2.22,
      "operations": 3.33,
      "total": 29.34,
      "electricity_usd_2026_kwh": 0.2206,
      "wacc": 0.1545,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 27.21,
      "electricity": 2.85,
      "site_grid": 1.87,
      "operations": 5.73,
      "total": 37.67,
      "electricity_usd_2026_kwh": 0.2206,
      "wacc": 0.1545,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 46.21,
      "electricity": 6.03,
      "site_grid": 4.75,
      "operations": 7.72,
      "total": 64.7,
      "electricity_usd_2026_kwh": 0.2206,
      "wacc": 0.1545,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 58.3,
      "electricity": 7.73,
      "site_grid": 4.02,
      "operations": 13.51,
      "total": 83.56,
      "electricity_usd_2026_kwh": 0.2206,
      "wacc": 0.1545,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 102.23,
      "electricity": 14.2,
      "site_grid": 10.5,
      "operations": 18.36,
      "total": 145.3,
      "electricity_usd_2026_kwh": 0.2206,
      "wacc": 0.1545,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 128.99,
      "electricity": 18.22,
      "site_grid": 8.89,
      "operations": 32.59,
      "total": 188.67,
      "electricity_usd_2026_kwh": 0.2206,
      "wacc": 0.1545,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 21.93,
      "electricity": 2.24,
      "site_grid": 2.34,
      "operations": 3.33,
      "total": 29.84,
      "electricity_usd_2026_kwh": 0.2225,
      "wacc": 0.1647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 27.67,
      "electricity": 2.88,
      "site_grid": 1.97,
      "operations": 5.73,
      "total": 38.25,
      "electricity_usd_2026_kwh": 0.2225,
      "wacc": 0.1647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 46.99,
      "electricity": 6.08,
      "site_grid": 5.01,
      "operations": 7.72,
      "total": 65.8,
      "electricity_usd_2026_kwh": 0.2225,
      "wacc": 0.1647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 59.29,
      "electricity": 7.8,
      "site_grid": 4.21,
      "operations": 13.51,
      "total": 84.8,
      "electricity_usd_2026_kwh": 0.2225,
      "wacc": 0.1647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 103.97,
      "electricity": 14.32,
      "site_grid": 11.09,
      "operations": 18.36,
      "total": 147.74,
      "electricity_usd_2026_kwh": 0.2225,
      "wacc": 0.1647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 131.16,
      "electricity": 18.37,
      "site_grid": 9.32,
      "operations": 32.59,
      "total": 191.44,
      "electricity_usd_2026_kwh": 0.2225,
      "wacc": 0.1647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 21.06,
      "electricity": 2.36,
      "site_grid": 2.09,
      "operations": 3.33,
      "total": 28.84,
      "electricity_usd_2026_kwh": 0.2343,
      "wacc": 0.1402,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 26.57,
      "electricity": 3.03,
      "site_grid": 1.79,
      "operations": 5.73,
      "total": 37.12,
      "electricity_usd_2026_kwh": 0.2343,
      "wacc": 0.1402,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 45.12,
      "electricity": 6.4,
      "site_grid": 4.48,
      "operations": 7.72,
      "total": 63.71,
      "electricity_usd_2026_kwh": 0.2343,
      "wacc": 0.1402,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 56.93,
      "electricity": 8.21,
      "site_grid": 3.83,
      "operations": 13.51,
      "total": 82.48,
      "electricity_usd_2026_kwh": 0.2343,
      "wacc": 0.1402,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 99.81,
      "electricity": 15.08,
      "site_grid": 9.91,
      "operations": 18.36,
      "total": 143.16,
      "electricity_usd_2026_kwh": 0.2343,
      "wacc": 0.1402,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 125.95,
      "electricity": 19.35,
      "site_grid": 8.47,
      "operations": 32.59,
      "total": 186.35,
      "electricity_usd_2026_kwh": 0.2343,
      "wacc": 0.1402,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.89,
      "electricity": 2.46,
      "site_grid": 1.77,
      "operations": 3.33,
      "total": 27.46,
      "electricity_usd_2026_kwh": 0.2444,
      "wacc": 0.1071,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.11,
      "electricity": 3.16,
      "site_grid": 1.56,
      "operations": 5.73,
      "total": 35.56,
      "electricity_usd_2026_kwh": 0.2444,
      "wacc": 0.1071,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.62,
      "electricity": 6.68,
      "site_grid": 3.8,
      "operations": 7.72,
      "total": 60.81,
      "electricity_usd_2026_kwh": 0.2444,
      "wacc": 0.1071,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.8,
      "electricity": 8.57,
      "site_grid": 3.34,
      "operations": 13.51,
      "total": 79.21,
      "electricity_usd_2026_kwh": 0.2444,
      "wacc": 0.1071,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.28,
      "electricity": 15.73,
      "site_grid": 8.41,
      "operations": 18.36,
      "total": 136.78,
      "electricity_usd_2026_kwh": 0.2444,
      "wacc": 0.1071,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 119.01,
      "electricity": 20.18,
      "site_grid": 7.39,
      "operations": 32.59,
      "total": 179.17,
      "electricity_usd_2026_kwh": 0.2444,
      "wacc": 0.1071,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.23,
      "electricity": 1.91,
      "site_grid": 1.61,
      "operations": 3.33,
      "total": 26.08,
      "electricity_usd_2026_kwh": 0.189,
      "wacc": 0.0881,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.28,
      "electricity": 2.44,
      "site_grid": 1.45,
      "operations": 5.73,
      "total": 33.9,
      "electricity_usd_2026_kwh": 0.189,
      "wacc": 0.0881,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.2,
      "electricity": 5.16,
      "site_grid": 3.46,
      "operations": 7.72,
      "total": 57.54,
      "electricity_usd_2026_kwh": 0.189,
      "wacc": 0.0881,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.02,
      "electricity": 6.63,
      "site_grid": 3.1,
      "operations": 13.51,
      "total": 75.25,
      "electricity_usd_2026_kwh": 0.189,
      "wacc": 0.0881,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 91.15,
      "electricity": 12.16,
      "site_grid": 7.65,
      "operations": 18.36,
      "total": 129.33,
      "electricity_usd_2026_kwh": 0.189,
      "wacc": 0.0881,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 115.08,
      "electricity": 15.61,
      "site_grid": 6.85,
      "operations": 32.59,
      "total": 170.13,
      "electricity_usd_2026_kwh": 0.189,
      "wacc": 0.0881,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.78,
      "electricity": 1.76,
      "site_grid": 1.48,
      "operations": 3.33,
      "total": 25.35,
      "electricity_usd_2026_kwh": 0.1744,
      "wacc": 0.0751,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.72,
      "electricity": 2.26,
      "site_grid": 1.34,
      "operations": 5.73,
      "total": 33.05,
      "electricity_usd_2026_kwh": 0.1744,
      "wacc": 0.0751,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.24,
      "electricity": 4.77,
      "site_grid": 3.17,
      "operations": 7.72,
      "total": 55.89,
      "electricity_usd_2026_kwh": 0.1744,
      "wacc": 0.0751,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.81,
      "electricity": 6.11,
      "site_grid": 2.88,
      "operations": 13.51,
      "total": 73.31,
      "electricity_usd_2026_kwh": 0.1744,
      "wacc": 0.0751,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.03,
      "electricity": 11.22,
      "site_grid": 7.01,
      "operations": 18.36,
      "total": 125.62,
      "electricity_usd_2026_kwh": 0.1744,
      "wacc": 0.0751,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.42,
      "electricity": 14.4,
      "site_grid": 6.36,
      "operations": 32.59,
      "total": 165.77,
      "electricity_usd_2026_kwh": 0.1744,
      "wacc": 0.0751,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.78,
      "electricity": 1.74,
      "site_grid": 1.48,
      "operations": 3.33,
      "total": 25.33,
      "electricity_usd_2026_kwh": 0.1724,
      "wacc": 0.075,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.71,
      "electricity": 2.23,
      "site_grid": 1.35,
      "operations": 5.73,
      "total": 33.02,
      "electricity_usd_2026_kwh": 0.1724,
      "wacc": 0.075,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.24,
      "electricity": 4.71,
      "site_grid": 3.18,
      "operations": 7.72,
      "total": 55.84,
      "electricity_usd_2026_kwh": 0.1724,
      "wacc": 0.075,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.81,
      "electricity": 6.04,
      "site_grid": 2.89,
      "operations": 13.51,
      "total": 73.24,
      "electricity_usd_2026_kwh": 0.1724,
      "wacc": 0.075,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.01,
      "electricity": 11.09,
      "site_grid": 7.03,
      "operations": 18.36,
      "total": 125.5,
      "electricity_usd_2026_kwh": 0.1724,
      "wacc": 0.075,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.4,
      "electricity": 14.24,
      "site_grid": 6.39,
      "operations": 32.59,
      "total": 165.61,
      "electricity_usd_2026_kwh": 0.1724,
      "wacc": 0.075,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.81,
      "electricity": 1.64,
      "site_grid": 1.52,
      "operations": 3.33,
      "total": 25.3,
      "electricity_usd_2026_kwh": 0.1623,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.75,
      "electricity": 2.1,
      "site_grid": 1.38,
      "operations": 5.73,
      "total": 32.96,
      "electricity_usd_2026_kwh": 0.1623,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.3,
      "electricity": 4.43,
      "site_grid": 3.27,
      "operations": 7.72,
      "total": 55.71,
      "electricity_usd_2026_kwh": 0.1623,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.88,
      "electricity": 5.69,
      "site_grid": 2.96,
      "operations": 13.51,
      "total": 73.04,
      "electricity_usd_2026_kwh": 0.1623,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.15,
      "electricity": 10.44,
      "site_grid": 7.22,
      "operations": 18.36,
      "total": 125.18,
      "electricity_usd_2026_kwh": 0.1623,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.57,
      "electricity": 13.4,
      "site_grid": 6.56,
      "operations": 32.59,
      "total": 165.12,
      "electricity_usd_2026_kwh": 0.1623,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.54,
      "electricity": 1.57,
      "site_grid": 1.51,
      "operations": 3.33,
      "total": 24.96,
      "electricity_usd_2026_kwh": 0.1563,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.42,
      "electricity": 2.02,
      "site_grid": 1.38,
      "operations": 5.73,
      "total": 32.55,
      "electricity_usd_2026_kwh": 0.1563,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.73,
      "electricity": 4.27,
      "site_grid": 3.23,
      "operations": 7.72,
      "total": 54.95,
      "electricity_usd_2026_kwh": 0.1563,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.17,
      "electricity": 5.48,
      "site_grid": 2.96,
      "operations": 13.51,
      "total": 72.12,
      "electricity_usd_2026_kwh": 0.1563,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.9,
      "electricity": 10.05,
      "site_grid": 7.15,
      "operations": 18.36,
      "total": 123.47,
      "electricity_usd_2026_kwh": 0.1563,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.0,
      "electricity": 12.9,
      "site_grid": 6.55,
      "operations": 32.59,
      "total": 163.04,
      "electricity_usd_2026_kwh": 0.1563,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.12,
      "electricity": 1.57,
      "site_grid": 1.41,
      "operations": 3.33,
      "total": 24.43,
      "electricity_usd_2026_kwh": 0.1557,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.88,
      "electricity": 2.01,
      "site_grid": 1.31,
      "operations": 5.73,
      "total": 31.94,
      "electricity_usd_2026_kwh": 0.1557,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.82,
      "electricity": 4.25,
      "site_grid": 3.02,
      "operations": 7.72,
      "total": 53.81,
      "electricity_usd_2026_kwh": 0.1557,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.03,
      "electricity": 5.46,
      "site_grid": 2.81,
      "operations": 13.51,
      "total": 70.8,
      "electricity_usd_2026_kwh": 0.1557,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.88,
      "electricity": 10.02,
      "site_grid": 6.69,
      "operations": 18.36,
      "total": 120.94,
      "electricity_usd_2026_kwh": 0.1557,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.46,
      "electricity": 12.85,
      "site_grid": 6.22,
      "operations": 32.59,
      "total": 160.13,
      "electricity_usd_2026_kwh": 0.1557,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.31,
      "electricity": 2.48,
      "site_grid": 1.47,
      "operations": 3.33,
      "total": 25.59,
      "electricity_usd_2026_kwh": 0.2462,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.12,
      "electricity": 3.18,
      "site_grid": 1.36,
      "operations": 5.73,
      "total": 33.4,
      "electricity_usd_2026_kwh": 0.2462,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.22,
      "electricity": 6.73,
      "site_grid": 3.16,
      "operations": 7.72,
      "total": 56.82,
      "electricity_usd_2026_kwh": 0.2462,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.54,
      "electricity": 8.63,
      "site_grid": 2.91,
      "operations": 13.51,
      "total": 74.59,
      "electricity_usd_2026_kwh": 0.2462,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.78,
      "electricity": 15.84,
      "site_grid": 6.98,
      "operations": 18.36,
      "total": 127.96,
      "electricity_usd_2026_kwh": 0.2462,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.59,
      "electricity": 20.33,
      "site_grid": 6.45,
      "operations": 32.59,
      "total": 168.96,
      "electricity_usd_2026_kwh": 0.2462,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.82,
      "electricity": 2.86,
      "site_grid": 1.84,
      "operations": 3.33,
      "total": 26.85,
      "electricity_usd_2026_kwh": 0.2835,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.77,
      "electricity": 3.67,
      "site_grid": 1.67,
      "operations": 5.73,
      "total": 34.83,
      "electricity_usd_2026_kwh": 0.2835,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.32,
      "electricity": 7.75,
      "site_grid": 3.94,
      "operations": 7.72,
      "total": 59.73,
      "electricity_usd_2026_kwh": 0.2835,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.92,
      "electricity": 9.94,
      "site_grid": 3.58,
      "operations": 13.51,
      "total": 77.94,
      "electricity_usd_2026_kwh": 0.2835,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.21,
      "electricity": 18.24,
      "site_grid": 8.72,
      "operations": 18.36,
      "total": 134.54,
      "electricity_usd_2026_kwh": 0.2835,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.65,
      "electricity": 23.41,
      "site_grid": 7.91,
      "operations": 32.59,
      "total": 176.56,
      "electricity_usd_2026_kwh": 0.2835,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.17,
      "electricity": 2.21,
      "site_grid": 2.03,
      "operations": 3.33,
      "total": 26.73,
      "electricity_usd_2026_kwh": 0.2191,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.2,
      "electricity": 2.83,
      "site_grid": 1.82,
      "operations": 5.73,
      "total": 34.59,
      "electricity_usd_2026_kwh": 0.2191,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.07,
      "electricity": 5.99,
      "site_grid": 4.34,
      "operations": 7.72,
      "total": 59.11,
      "electricity_usd_2026_kwh": 0.2191,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.85,
      "electricity": 7.68,
      "site_grid": 3.89,
      "operations": 13.51,
      "total": 76.93,
      "electricity_usd_2026_kwh": 0.2191,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.86,
      "electricity": 14.1,
      "site_grid": 9.6,
      "operations": 18.36,
      "total": 132.92,
      "electricity_usd_2026_kwh": 0.2191,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 114.72,
      "electricity": 18.09,
      "site_grid": 8.61,
      "operations": 32.59,
      "total": 174.01,
      "electricity_usd_2026_kwh": 0.2191,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.25,
      "electricity": 2.04,
      "site_grid": 1.99,
      "operations": 3.33,
      "total": 26.62,
      "electricity_usd_2026_kwh": 0.2027,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.31,
      "electricity": 2.62,
      "site_grid": 1.78,
      "operations": 5.73,
      "total": 34.44,
      "electricity_usd_2026_kwh": 0.2027,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.25,
      "electricity": 5.54,
      "site_grid": 4.27,
      "operations": 7.72,
      "total": 58.77,
      "electricity_usd_2026_kwh": 0.2027,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.08,
      "electricity": 7.1,
      "site_grid": 3.82,
      "operations": 13.51,
      "total": 76.51,
      "electricity_usd_2026_kwh": 0.2027,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 91.27,
      "electricity": 13.04,
      "site_grid": 9.44,
      "operations": 18.36,
      "total": 132.11,
      "electricity_usd_2026_kwh": 0.2027,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 115.23,
      "electricity": 16.73,
      "site_grid": 8.44,
      "operations": 32.59,
      "total": 172.99,
      "electricity_usd_2026_kwh": 0.2027,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.28,
      "electricity": 2.15,
      "site_grid": 1.98,
      "operations": 3.33,
      "total": 26.74,
      "electricity_usd_2026_kwh": 0.2133,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.35,
      "electricity": 2.76,
      "site_grid": 1.77,
      "operations": 5.73,
      "total": 34.6,
      "electricity_usd_2026_kwh": 0.2133,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.32,
      "electricity": 5.83,
      "site_grid": 4.23,
      "operations": 7.72,
      "total": 59.09,
      "electricity_usd_2026_kwh": 0.2133,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.16,
      "electricity": 7.48,
      "site_grid": 3.78,
      "operations": 13.51,
      "total": 76.93,
      "electricity_usd_2026_kwh": 0.2133,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 91.41,
      "electricity": 13.73,
      "site_grid": 9.36,
      "operations": 18.36,
      "total": 132.86,
      "electricity_usd_2026_kwh": 0.2133,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 115.4,
      "electricity": 17.61,
      "site_grid": 8.37,
      "operations": 32.59,
      "total": 173.98,
      "electricity_usd_2026_kwh": 0.2133,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.3,
      "electricity": 2.01,
      "site_grid": 1.99,
      "operations": 3.33,
      "total": 26.62,
      "electricity_usd_2026_kwh": 0.1995,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.36,
      "electricity": 2.58,
      "site_grid": 1.77,
      "operations": 5.73,
      "total": 34.45,
      "electricity_usd_2026_kwh": 0.1995,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.34,
      "electricity": 5.45,
      "site_grid": 4.25,
      "operations": 7.72,
      "total": 58.76,
      "electricity_usd_2026_kwh": 0.1995,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.2,
      "electricity": 6.99,
      "site_grid": 3.8,
      "operations": 13.51,
      "total": 76.5,
      "electricity_usd_2026_kwh": 0.1995,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 91.47,
      "electricity": 12.84,
      "site_grid": 9.41,
      "operations": 18.36,
      "total": 132.08,
      "electricity_usd_2026_kwh": 0.1995,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 115.48,
      "electricity": 16.47,
      "site_grid": 8.41,
      "operations": 32.59,
      "total": 172.95,
      "electricity_usd_2026_kwh": 0.1995,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.72,
      "electricity": 2.03,
      "site_grid": 1.39,
      "operations": 3.25,
      "total": 25.4,
      "electricity_usd_2026_kwh": 0.2123,
      "wacc": 0.0788,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.61,
      "electricity": 2.6,
      "site_grid": 1.23,
      "operations": 5.58,
      "total": 33.02,
      "electricity_usd_2026_kwh": 0.2123,
      "wacc": 0.0788,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.11,
      "electricity": 5.5,
      "site_grid": 2.98,
      "operations": 7.56,
      "total": 56.15,
      "electricity_usd_2026_kwh": 0.2123,
      "wacc": 0.0788,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.59,
      "electricity": 7.06,
      "site_grid": 2.63,
      "operations": 13.17,
      "total": 73.44,
      "electricity_usd_2026_kwh": 0.2123,
      "wacc": 0.0788,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.74,
      "electricity": 12.96,
      "site_grid": 6.6,
      "operations": 18.01,
      "total": 126.31,
      "electricity_usd_2026_kwh": 0.2123,
      "wacc": 0.0788,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.92,
      "electricity": 16.63,
      "site_grid": 5.81,
      "operations": 31.83,
      "total": 166.19,
      "electricity_usd_2026_kwh": 0.2123,
      "wacc": 0.0788,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.57,
      "electricity": 1.95,
      "site_grid": 1.34,
      "operations": 3.25,
      "total": 25.11,
      "electricity_usd_2026_kwh": 0.2039,
      "wacc": 0.0745,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.43,
      "electricity": 2.5,
      "site_grid": 1.18,
      "operations": 5.58,
      "total": 32.68,
      "electricity_usd_2026_kwh": 0.2039,
      "wacc": 0.0745,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.8,
      "electricity": 5.28,
      "site_grid": 2.86,
      "operations": 7.56,
      "total": 55.5,
      "electricity_usd_2026_kwh": 0.2039,
      "wacc": 0.0745,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.19,
      "electricity": 6.78,
      "site_grid": 2.53,
      "operations": 13.17,
      "total": 72.67,
      "electricity_usd_2026_kwh": 0.2039,
      "wacc": 0.0745,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.04,
      "electricity": 12.44,
      "site_grid": 6.34,
      "operations": 18.01,
      "total": 124.83,
      "electricity_usd_2026_kwh": 0.2039,
      "wacc": 0.0745,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.04,
      "electricity": 15.96,
      "site_grid": 5.6,
      "operations": 31.83,
      "total": 164.44,
      "electricity_usd_2026_kwh": 0.2039,
      "wacc": 0.0745,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.24,
      "electricity": 1.72,
      "site_grid": 1.26,
      "operations": 3.25,
      "total": 24.48,
      "electricity_usd_2026_kwh": 0.1801,
      "wacc": 0.0647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.01,
      "electricity": 2.21,
      "site_grid": 1.13,
      "operations": 5.58,
      "total": 31.92,
      "electricity_usd_2026_kwh": 0.1801,
      "wacc": 0.0647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.09,
      "electricity": 4.67,
      "site_grid": 2.7,
      "operations": 7.56,
      "total": 54.01,
      "electricity_usd_2026_kwh": 0.1801,
      "wacc": 0.0647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.3,
      "electricity": 5.99,
      "site_grid": 2.42,
      "operations": 13.17,
      "total": 70.87,
      "electricity_usd_2026_kwh": 0.1801,
      "wacc": 0.0647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.47,
      "electricity": 10.99,
      "site_grid": 5.98,
      "operations": 18.01,
      "total": 121.45,
      "electricity_usd_2026_kwh": 0.1801,
      "wacc": 0.0647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.07,
      "electricity": 14.1,
      "site_grid": 5.34,
      "operations": 31.83,
      "total": 160.35,
      "electricity_usd_2026_kwh": 0.1801,
      "wacc": 0.0647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.43,
      "electricity": 1.75,
      "site_grid": 1.32,
      "operations": 3.25,
      "total": 24.75,
      "electricity_usd_2026_kwh": 0.1831,
      "wacc": 0.0702,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.24,
      "electricity": 2.25,
      "site_grid": 1.17,
      "operations": 5.58,
      "total": 32.24,
      "electricity_usd_2026_kwh": 0.1831,
      "wacc": 0.0702,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.48,
      "electricity": 4.74,
      "site_grid": 2.82,
      "operations": 7.56,
      "total": 54.61,
      "electricity_usd_2026_kwh": 0.1831,
      "wacc": 0.0702,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.8,
      "electricity": 6.09,
      "site_grid": 2.51,
      "operations": 13.17,
      "total": 71.56,
      "electricity_usd_2026_kwh": 0.1831,
      "wacc": 0.0702,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.35,
      "electricity": 11.17,
      "site_grid": 6.25,
      "operations": 18.01,
      "total": 122.78,
      "electricity_usd_2026_kwh": 0.1831,
      "wacc": 0.0702,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.17,
      "electricity": 14.34,
      "site_grid": 5.55,
      "operations": 31.83,
      "total": 161.89,
      "electricity_usd_2026_kwh": 0.1831,
      "wacc": 0.0702,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.49,
      "electricity": 1.61,
      "site_grid": 1.36,
      "operations": 3.25,
      "total": 24.71,
      "electricity_usd_2026_kwh": 0.1682,
      "wacc": 0.0721,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.32,
      "electricity": 2.06,
      "site_grid": 1.2,
      "operations": 5.58,
      "total": 32.16,
      "electricity_usd_2026_kwh": 0.1682,
      "wacc": 0.0721,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.62,
      "electricity": 4.36,
      "site_grid": 2.9,
      "operations": 7.56,
      "total": 54.44,
      "electricity_usd_2026_kwh": 0.1682,
      "wacc": 0.0721,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.97,
      "electricity": 5.59,
      "site_grid": 2.57,
      "operations": 13.17,
      "total": 71.31,
      "electricity_usd_2026_kwh": 0.1682,
      "wacc": 0.0721,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.65,
      "electricity": 10.27,
      "site_grid": 6.42,
      "operations": 18.01,
      "total": 122.35,
      "electricity_usd_2026_kwh": 0.1682,
      "wacc": 0.0721,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.55,
      "electricity": 13.17,
      "site_grid": 5.7,
      "operations": 31.83,
      "total": 161.26,
      "electricity_usd_2026_kwh": 0.1682,
      "wacc": 0.0721,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.36,
      "electricity": 1.29,
      "site_grid": 1.34,
      "operations": 3.25,
      "total": 24.24,
      "electricity_usd_2026_kwh": 0.1345,
      "wacc": 0.0681,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.15,
      "electricity": 1.65,
      "site_grid": 1.2,
      "operations": 5.58,
      "total": 31.58,
      "electricity_usd_2026_kwh": 0.1345,
      "wacc": 0.0681,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.33,
      "electricity": 3.48,
      "site_grid": 2.88,
      "operations": 7.56,
      "total": 53.25,
      "electricity_usd_2026_kwh": 0.1345,
      "wacc": 0.0681,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.61,
      "electricity": 4.47,
      "site_grid": 2.57,
      "operations": 13.17,
      "total": 69.81,
      "electricity_usd_2026_kwh": 0.1345,
      "wacc": 0.0681,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.01,
      "electricity": 8.21,
      "site_grid": 6.37,
      "operations": 18.01,
      "total": 119.59,
      "electricity_usd_2026_kwh": 0.1345,
      "wacc": 0.0681,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.74,
      "electricity": 10.53,
      "site_grid": 5.68,
      "operations": 31.83,
      "total": 157.78,
      "electricity_usd_2026_kwh": 0.1345,
      "wacc": 0.0681,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.25,
      "electricity": 1.17,
      "site_grid": 1.31,
      "operations": 3.25,
      "total": 23.98,
      "electricity_usd_2026_kwh": 0.122,
      "wacc": 0.0651,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.03,
      "electricity": 1.5,
      "site_grid": 1.17,
      "operations": 5.58,
      "total": 31.27,
      "electricity_usd_2026_kwh": 0.122,
      "wacc": 0.0651,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.11,
      "electricity": 3.16,
      "site_grid": 2.8,
      "operations": 7.56,
      "total": 52.63,
      "electricity_usd_2026_kwh": 0.122,
      "wacc": 0.0651,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.33,
      "electricity": 4.06,
      "site_grid": 2.51,
      "operations": 13.17,
      "total": 69.07,
      "electricity_usd_2026_kwh": 0.122,
      "wacc": 0.0651,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.53,
      "electricity": 7.45,
      "site_grid": 6.21,
      "operations": 18.01,
      "total": 118.19,
      "electricity_usd_2026_kwh": 0.122,
      "wacc": 0.0651,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.14,
      "electricity": 9.56,
      "site_grid": 5.55,
      "operations": 31.83,
      "total": 156.08,
      "electricity_usd_2026_kwh": 0.122,
      "wacc": 0.0651,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.42,
      "electricity": 1.13,
      "site_grid": 1.36,
      "operations": 3.25,
      "total": 24.16,
      "electricity_usd_2026_kwh": 0.1182,
      "wacc": 0.07,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.23,
      "electricity": 1.45,
      "site_grid": 1.21,
      "operations": 5.58,
      "total": 31.47,
      "electricity_usd_2026_kwh": 0.1182,
      "wacc": 0.07,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.47,
      "electricity": 3.06,
      "site_grid": 2.91,
      "operations": 7.56,
      "total": 52.99,
      "electricity_usd_2026_kwh": 0.1182,
      "wacc": 0.07,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.78,
      "electricity": 3.93,
      "site_grid": 2.58,
      "operations": 13.17,
      "total": 69.46,
      "electricity_usd_2026_kwh": 0.1182,
      "wacc": 0.07,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.32,
      "electricity": 7.21,
      "site_grid": 6.43,
      "operations": 18.01,
      "total": 118.97,
      "electricity_usd_2026_kwh": 0.1182,
      "wacc": 0.07,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.13,
      "electricity": 9.25,
      "site_grid": 5.72,
      "operations": 31.83,
      "total": 156.93,
      "electricity_usd_2026_kwh": 0.1182,
      "wacc": 0.07,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.62,
      "electricity": 1.23,
      "site_grid": 1.44,
      "operations": 3.25,
      "total": 24.55,
      "electricity_usd_2026_kwh": 0.1292,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.48,
      "electricity": 1.58,
      "site_grid": 1.27,
      "operations": 5.58,
      "total": 31.91,
      "electricity_usd_2026_kwh": 0.1292,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.89,
      "electricity": 3.35,
      "site_grid": 3.09,
      "operations": 7.56,
      "total": 53.88,
      "electricity_usd_2026_kwh": 0.1292,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.31,
      "electricity": 4.3,
      "site_grid": 2.73,
      "operations": 13.17,
      "total": 70.5,
      "electricity_usd_2026_kwh": 0.1292,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.25,
      "electricity": 7.88,
      "site_grid": 6.83,
      "operations": 18.01,
      "total": 120.97,
      "electricity_usd_2026_kwh": 0.1292,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.3,
      "electricity": 10.12,
      "site_grid": 6.03,
      "operations": 31.83,
      "total": 159.28,
      "electricity_usd_2026_kwh": 0.1292,
      "wacc": 0.0758,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.36,
      "electricity": 1.33,
      "site_grid": 1.43,
      "operations": 3.25,
      "total": 24.37,
      "electricity_usd_2026_kwh": 0.1393,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.15,
      "electricity": 1.71,
      "site_grid": 1.27,
      "operations": 5.58,
      "total": 31.71,
      "electricity_usd_2026_kwh": 0.1393,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.33,
      "electricity": 3.61,
      "site_grid": 3.06,
      "operations": 7.56,
      "total": 53.55,
      "electricity_usd_2026_kwh": 0.1393,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.61,
      "electricity": 4.63,
      "site_grid": 2.72,
      "operations": 13.17,
      "total": 70.13,
      "electricity_usd_2026_kwh": 0.1393,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.01,
      "electricity": 8.5,
      "site_grid": 6.76,
      "operations": 18.01,
      "total": 120.28,
      "electricity_usd_2026_kwh": 0.1393,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.75,
      "electricity": 10.91,
      "site_grid": 6.02,
      "operations": 31.83,
      "total": 158.52,
      "electricity_usd_2026_kwh": 0.1393,
      "wacc": 0.0681,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.94,
      "electricity": 1.35,
      "site_grid": 1.33,
      "operations": 3.25,
      "total": 23.87,
      "electricity_usd_2026_kwh": 0.1411,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.63,
      "electricity": 1.73,
      "site_grid": 1.21,
      "operations": 5.58,
      "total": 31.14,
      "electricity_usd_2026_kwh": 0.1411,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.43,
      "electricity": 3.66,
      "site_grid": 2.86,
      "operations": 7.56,
      "total": 52.5,
      "electricity_usd_2026_kwh": 0.1411,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.47,
      "electricity": 4.69,
      "site_grid": 2.59,
      "operations": 13.17,
      "total": 68.92,
      "electricity_usd_2026_kwh": 0.1411,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.01,
      "electricity": 8.61,
      "site_grid": 6.32,
      "operations": 18.01,
      "total": 117.95,
      "electricity_usd_2026_kwh": 0.1411,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.24,
      "electricity": 11.05,
      "site_grid": 5.72,
      "operations": 31.83,
      "total": 155.85,
      "electricity_usd_2026_kwh": 0.1411,
      "wacc": 0.0556,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.12,
      "electricity": 1.35,
      "site_grid": 1.39,
      "operations": 3.25,
      "total": 24.12,
      "electricity_usd_2026_kwh": 0.1409,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.86,
      "electricity": 1.73,
      "site_grid": 1.25,
      "operations": 5.58,
      "total": 31.42,
      "electricity_usd_2026_kwh": 0.1409,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.83,
      "electricity": 3.65,
      "site_grid": 2.98,
      "operations": 7.56,
      "total": 53.02,
      "electricity_usd_2026_kwh": 0.1409,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.98,
      "electricity": 4.69,
      "site_grid": 2.68,
      "operations": 13.17,
      "total": 69.51,
      "electricity_usd_2026_kwh": 0.1409,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.9,
      "electricity": 8.6,
      "site_grid": 6.6,
      "operations": 18.01,
      "total": 119.11,
      "electricity_usd_2026_kwh": 0.1409,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.36,
      "electricity": 11.04,
      "site_grid": 5.93,
      "operations": 31.83,
      "total": 157.16,
      "electricity_usd_2026_kwh": 0.1409,
      "wacc": 0.0612,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.63,
      "electricity": 2.22,
      "site_grid": 1.74,
      "operations": 3.25,
      "total": 25.84,
      "electricity_usd_2026_kwh": 0.232,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.5,
      "electricity": 2.85,
      "site_grid": 1.54,
      "operations": 5.58,
      "total": 33.46,
      "electricity_usd_2026_kwh": 0.232,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.92,
      "electricity": 6.01,
      "site_grid": 3.73,
      "operations": 7.56,
      "total": 57.21,
      "electricity_usd_2026_kwh": 0.232,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.35,
      "electricity": 7.71,
      "site_grid": 3.29,
      "operations": 13.17,
      "total": 74.52,
      "electricity_usd_2026_kwh": 0.232,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.32,
      "electricity": 14.16,
      "site_grid": 8.25,
      "operations": 18.01,
      "total": 128.73,
      "electricity_usd_2026_kwh": 0.232,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.38,
      "electricity": 18.17,
      "site_grid": 7.28,
      "operations": 31.83,
      "total": 168.66,
      "electricity_usd_2026_kwh": 0.232,
      "wacc": 0.0762,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.98,
      "electricity": 3.24,
      "site_grid": 1.91,
      "operations": 3.25,
      "total": 27.38,
      "electricity_usd_2026_kwh": 0.3386,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.93,
      "electricity": 4.15,
      "site_grid": 1.67,
      "operations": 5.58,
      "total": 35.33,
      "electricity_usd_2026_kwh": 0.3386,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.66,
      "electricity": 8.77,
      "site_grid": 4.1,
      "operations": 7.56,
      "total": 61.09,
      "electricity_usd_2026_kwh": 0.3386,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.27,
      "electricity": 11.26,
      "site_grid": 3.58,
      "operations": 13.17,
      "total": 79.28,
      "electricity_usd_2026_kwh": 0.3386,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.94,
      "electricity": 20.67,
      "site_grid": 9.08,
      "operations": 18.01,
      "total": 137.69,
      "electricity_usd_2026_kwh": 0.3386,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 113.42,
      "electricity": 26.52,
      "site_grid": 7.92,
      "operations": 31.83,
      "total": 179.7,
      "electricity_usd_2026_kwh": 0.3386,
      "wacc": 0.0863,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.06,
      "electricity": 2.49,
      "site_grid": 1.88,
      "operations": 3.25,
      "total": 26.68,
      "electricity_usd_2026_kwh": 0.2601,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.04,
      "electricity": 3.19,
      "site_grid": 1.64,
      "operations": 5.58,
      "total": 34.44,
      "electricity_usd_2026_kwh": 0.2601,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.84,
      "electricity": 6.74,
      "site_grid": 4.03,
      "operations": 7.56,
      "total": 59.17,
      "electricity_usd_2026_kwh": 0.2601,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.5,
      "electricity": 8.65,
      "site_grid": 3.51,
      "operations": 13.17,
      "total": 76.82,
      "electricity_usd_2026_kwh": 0.2601,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.35,
      "electricity": 15.87,
      "site_grid": 8.92,
      "operations": 18.01,
      "total": 133.15,
      "electricity_usd_2026_kwh": 0.2601,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 113.93,
      "electricity": 20.37,
      "site_grid": 7.76,
      "operations": 31.83,
      "total": 173.89,
      "electricity_usd_2026_kwh": 0.2601,
      "wacc": 0.0888,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.09,
      "electricity": 2.37,
      "site_grid": 1.87,
      "operations": 3.25,
      "total": 26.58,
      "electricity_usd_2026_kwh": 0.2477,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.07,
      "electricity": 3.04,
      "site_grid": 1.62,
      "operations": 5.58,
      "total": 34.31,
      "electricity_usd_2026_kwh": 0.2477,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.9,
      "electricity": 6.42,
      "site_grid": 4.0,
      "operations": 7.56,
      "total": 58.88,
      "electricity_usd_2026_kwh": 0.2477,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.58,
      "electricity": 8.24,
      "site_grid": 3.48,
      "operations": 13.17,
      "total": 76.46,
      "electricity_usd_2026_kwh": 0.2477,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.49,
      "electricity": 15.12,
      "site_grid": 8.85,
      "operations": 18.01,
      "total": 132.47,
      "electricity_usd_2026_kwh": 0.2477,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 114.1,
      "electricity": 19.4,
      "site_grid": 7.7,
      "operations": 31.83,
      "total": 173.03,
      "electricity_usd_2026_kwh": 0.2477,
      "wacc": 0.0896,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.1,
      "electricity": 2.34,
      "site_grid": 1.88,
      "operations": 3.25,
      "total": 26.57,
      "electricity_usd_2026_kwh": 0.2445,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.09,
      "electricity": 3.0,
      "site_grid": 1.63,
      "operations": 5.58,
      "total": 34.29,
      "electricity_usd_2026_kwh": 0.2445,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.93,
      "electricity": 6.33,
      "site_grid": 4.02,
      "operations": 7.56,
      "total": 58.84,
      "electricity_usd_2026_kwh": 0.2445,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.61,
      "electricity": 8.13,
      "site_grid": 3.5,
      "operations": 13.17,
      "total": 76.4,
      "electricity_usd_2026_kwh": 0.2445,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.55,
      "electricity": 14.92,
      "site_grid": 8.9,
      "operations": 18.01,
      "total": 132.37,
      "electricity_usd_2026_kwh": 0.2445,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 114.18,
      "electricity": 19.14,
      "site_grid": 7.73,
      "operations": 31.83,
      "total": 172.89,
      "electricity_usd_2026_kwh": 0.2445,
      "wacc": 0.09,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.16,
      "electricity": 2.08,
      "site_grid": 1.84,
      "operations": 3.32,
      "total": 25.4,
      "electricity_usd_2026_kwh": 0.2265,
      "wacc": 0.0838,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.84,
      "electricity": 2.67,
      "site_grid": 2.12,
      "operations": 6.56,
      "total": 34.2,
      "electricity_usd_2026_kwh": 0.2265,
      "wacc": 0.0838,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.9,
      "electricity": 5.65,
      "site_grid": 3.94,
      "operations": 7.7,
      "total": 56.2,
      "electricity_usd_2026_kwh": 0.2265,
      "wacc": 0.0838,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.94,
      "electricity": 7.24,
      "site_grid": 4.55,
      "operations": 15.28,
      "total": 76.01,
      "electricity_usd_2026_kwh": 0.2265,
      "wacc": 0.0838,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.06,
      "electricity": 13.31,
      "site_grid": 8.72,
      "operations": 18.33,
      "total": 126.43,
      "electricity_usd_2026_kwh": 0.2265,
      "wacc": 0.0838,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.27,
      "electricity": 17.05,
      "site_grid": 10.06,
      "operations": 36.49,
      "total": 171.88,
      "electricity_usd_2026_kwh": 0.2265,
      "wacc": 0.0838,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.34,
      "electricity": 2.31,
      "site_grid": 1.88,
      "operations": 3.32,
      "total": 25.85,
      "electricity_usd_2026_kwh": 0.2505,
      "wacc": 0.0895,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.07,
      "electricity": 2.95,
      "site_grid": 2.16,
      "operations": 6.56,
      "total": 34.75,
      "electricity_usd_2026_kwh": 0.2505,
      "wacc": 0.0895,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.3,
      "electricity": 6.25,
      "site_grid": 4.03,
      "operations": 7.7,
      "total": 57.28,
      "electricity_usd_2026_kwh": 0.2505,
      "wacc": 0.0895,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.44,
      "electricity": 8.01,
      "site_grid": 4.62,
      "operations": 15.28,
      "total": 77.34,
      "electricity_usd_2026_kwh": 0.2505,
      "wacc": 0.0895,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.95,
      "electricity": 14.72,
      "site_grid": 8.92,
      "operations": 18.33,
      "total": 128.91,
      "electricity_usd_2026_kwh": 0.2505,
      "wacc": 0.0895,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.37,
      "electricity": 18.86,
      "site_grid": 10.22,
      "operations": 36.49,
      "total": 174.94,
      "electricity_usd_2026_kwh": 0.2505,
      "wacc": 0.0895,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.53,
      "electricity": 2.31,
      "site_grid": 1.61,
      "operations": 3.32,
      "total": 24.78,
      "electricity_usd_2026_kwh": 0.251,
      "wacc": 0.0647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.06,
      "electricity": 2.96,
      "site_grid": 1.9,
      "operations": 6.56,
      "total": 33.49,
      "electricity_usd_2026_kwh": 0.251,
      "wacc": 0.0647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.56,
      "electricity": 6.26,
      "site_grid": 3.45,
      "operations": 7.7,
      "total": 54.98,
      "electricity_usd_2026_kwh": 0.251,
      "wacc": 0.0647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.27,
      "electricity": 8.02,
      "site_grid": 4.08,
      "operations": 15.28,
      "total": 74.65,
      "electricity_usd_2026_kwh": 0.251,
      "wacc": 0.0647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.11,
      "electricity": 14.74,
      "site_grid": 7.64,
      "operations": 18.33,
      "total": 123.82,
      "electricity_usd_2026_kwh": 0.251,
      "wacc": 0.0647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.57,
      "electricity": 18.89,
      "site_grid": 9.02,
      "operations": 36.49,
      "total": 168.98,
      "electricity_usd_2026_kwh": 0.251,
      "wacc": 0.0647,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.32,
      "electricity": 2.37,
      "site_grid": 1.56,
      "operations": 3.32,
      "total": 24.57,
      "electricity_usd_2026_kwh": 0.2578,
      "wacc": 0.0582,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.8,
      "electricity": 3.04,
      "site_grid": 1.85,
      "operations": 6.56,
      "total": 33.25,
      "electricity_usd_2026_kwh": 0.2578,
      "wacc": 0.0582,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.11,
      "electricity": 6.43,
      "site_grid": 3.33,
      "operations": 7.7,
      "total": 54.58,
      "electricity_usd_2026_kwh": 0.2578,
      "wacc": 0.0582,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.7,
      "electricity": 8.24,
      "site_grid": 3.97,
      "operations": 15.28,
      "total": 74.19,
      "electricity_usd_2026_kwh": 0.2578,
      "wacc": 0.0582,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.1,
      "electricity": 15.15,
      "site_grid": 7.37,
      "operations": 18.33,
      "total": 122.95,
      "electricity_usd_2026_kwh": 0.2578,
      "wacc": 0.0582,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.32,
      "electricity": 19.41,
      "site_grid": 8.78,
      "operations": 36.49,
      "total": 168.0,
      "electricity_usd_2026_kwh": 0.2578,
      "wacc": 0.0582,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.12,
      "electricity": 2.32,
      "site_grid": 1.51,
      "operations": 3.32,
      "total": 24.29,
      "electricity_usd_2026_kwh": 0.2526,
      "wacc": 0.0521,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.55,
      "electricity": 2.98,
      "site_grid": 1.82,
      "operations": 6.56,
      "total": 32.91,
      "electricity_usd_2026_kwh": 0.2526,
      "wacc": 0.0521,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.69,
      "electricity": 6.3,
      "site_grid": 3.24,
      "operations": 7.7,
      "total": 53.94,
      "electricity_usd_2026_kwh": 0.2526,
      "wacc": 0.0521,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.17,
      "electricity": 8.07,
      "site_grid": 3.9,
      "operations": 15.28,
      "total": 73.42,
      "electricity_usd_2026_kwh": 0.2526,
      "wacc": 0.0521,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.17,
      "electricity": 14.84,
      "site_grid": 7.18,
      "operations": 18.33,
      "total": 121.52,
      "electricity_usd_2026_kwh": 0.2526,
      "wacc": 0.0521,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.15,
      "electricity": 19.01,
      "site_grid": 8.62,
      "operations": 36.49,
      "total": 166.28,
      "electricity_usd_2026_kwh": 0.2526,
      "wacc": 0.0521,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.0,
      "electricity": 1.98,
      "site_grid": 1.5,
      "operations": 3.32,
      "total": 23.79,
      "electricity_usd_2026_kwh": 0.2147,
      "wacc": 0.0481,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.39,
      "electricity": 2.53,
      "site_grid": 1.81,
      "operations": 6.56,
      "total": 32.3,
      "electricity_usd_2026_kwh": 0.2147,
      "wacc": 0.0481,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.41,
      "electricity": 5.36,
      "site_grid": 3.21,
      "operations": 7.7,
      "total": 52.68,
      "electricity_usd_2026_kwh": 0.2147,
      "wacc": 0.0481,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.83,
      "electricity": 6.86,
      "site_grid": 3.88,
      "operations": 15.28,
      "total": 71.85,
      "electricity_usd_2026_kwh": 0.2147,
      "wacc": 0.0481,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.56,
      "electricity": 12.62,
      "site_grid": 7.1,
      "operations": 18.33,
      "total": 118.61,
      "electricity_usd_2026_kwh": 0.2147,
      "wacc": 0.0481,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.39,
      "electricity": 16.16,
      "site_grid": 8.58,
      "operations": 36.49,
      "total": 162.63,
      "electricity_usd_2026_kwh": 0.2147,
      "wacc": 0.0481,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.9,
      "electricity": 1.8,
      "site_grid": 1.46,
      "operations": 3.32,
      "total": 23.48,
      "electricity_usd_2026_kwh": 0.1961,
      "wacc": 0.0451,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.27,
      "electricity": 2.31,
      "site_grid": 1.77,
      "operations": 6.56,
      "total": 31.91,
      "electricity_usd_2026_kwh": 0.1961,
      "wacc": 0.0451,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.21,
      "electricity": 4.89,
      "site_grid": 3.12,
      "operations": 7.7,
      "total": 51.92,
      "electricity_usd_2026_kwh": 0.1961,
      "wacc": 0.0451,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.57,
      "electricity": 6.27,
      "site_grid": 3.79,
      "operations": 15.28,
      "total": 70.9,
      "electricity_usd_2026_kwh": 0.1961,
      "wacc": 0.0451,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.1,
      "electricity": 11.52,
      "site_grid": 6.91,
      "operations": 18.33,
      "total": 116.86,
      "electricity_usd_2026_kwh": 0.1961,
      "wacc": 0.0451,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.81,
      "electricity": 14.76,
      "site_grid": 8.38,
      "operations": 36.49,
      "total": 160.45,
      "electricity_usd_2026_kwh": 0.1961,
      "wacc": 0.0451,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.06,
      "electricity": 1.74,
      "site_grid": 1.52,
      "operations": 3.32,
      "total": 23.63,
      "electricity_usd_2026_kwh": 0.1888,
      "wacc": 0.05,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.47,
      "electricity": 2.23,
      "site_grid": 1.83,
      "operations": 6.56,
      "total": 32.08,
      "electricity_usd_2026_kwh": 0.1888,
      "wacc": 0.05,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.54,
      "electricity": 4.71,
      "site_grid": 3.25,
      "operations": 7.7,
      "total": 52.2,
      "electricity_usd_2026_kwh": 0.1888,
      "wacc": 0.05,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.99,
      "electricity": 6.04,
      "site_grid": 3.91,
      "operations": 15.28,
      "total": 71.22,
      "electricity_usd_2026_kwh": 0.1888,
      "wacc": 0.05,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.85,
      "electricity": 11.09,
      "site_grid": 7.18,
      "operations": 18.33,
      "total": 117.45,
      "electricity_usd_2026_kwh": 0.1888,
      "wacc": 0.05,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.75,
      "electricity": 14.21,
      "site_grid": 8.65,
      "operations": 36.49,
      "total": 161.11,
      "electricity_usd_2026_kwh": 0.1888,
      "wacc": 0.05,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.24,
      "electricity": 1.91,
      "site_grid": 1.61,
      "operations": 3.32,
      "total": 24.09,
      "electricity_usd_2026_kwh": 0.2075,
      "wacc": 0.0558,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.7,
      "electricity": 2.45,
      "site_grid": 1.93,
      "operations": 6.56,
      "total": 32.64,
      "electricity_usd_2026_kwh": 0.2075,
      "wacc": 0.0558,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.95,
      "electricity": 5.18,
      "site_grid": 3.46,
      "operations": 7.7,
      "total": 53.28,
      "electricity_usd_2026_kwh": 0.2075,
      "wacc": 0.0558,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.49,
      "electricity": 6.63,
      "site_grid": 4.13,
      "operations": 15.28,
      "total": 72.54,
      "electricity_usd_2026_kwh": 0.2075,
      "wacc": 0.0558,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.74,
      "electricity": 12.19,
      "site_grid": 7.65,
      "operations": 18.33,
      "total": 119.91,
      "electricity_usd_2026_kwh": 0.2075,
      "wacc": 0.0558,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.86,
      "electricity": 15.62,
      "site_grid": 9.14,
      "operations": 36.49,
      "total": 164.12,
      "electricity_usd_2026_kwh": 0.2075,
      "wacc": 0.0558,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.0,
      "electricity": 1.78,
      "site_grid": 1.59,
      "operations": 3.32,
      "total": 23.69,
      "electricity_usd_2026_kwh": 0.194,
      "wacc": 0.0481,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.39,
      "electricity": 2.29,
      "site_grid": 1.92,
      "operations": 6.56,
      "total": 32.16,
      "electricity_usd_2026_kwh": 0.194,
      "wacc": 0.0481,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.41,
      "electricity": 4.84,
      "site_grid": 3.41,
      "operations": 7.7,
      "total": 52.36,
      "electricity_usd_2026_kwh": 0.194,
      "wacc": 0.0481,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.83,
      "electricity": 6.2,
      "site_grid": 4.12,
      "operations": 15.28,
      "total": 71.43,
      "electricity_usd_2026_kwh": 0.194,
      "wacc": 0.0481,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.56,
      "electricity": 11.4,
      "site_grid": 7.54,
      "operations": 18.33,
      "total": 117.83,
      "electricity_usd_2026_kwh": 0.194,
      "wacc": 0.0481,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.39,
      "electricity": 14.6,
      "site_grid": 9.11,
      "operations": 36.49,
      "total": 161.59,
      "electricity_usd_2026_kwh": 0.194,
      "wacc": 0.0481,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.74,
      "electricity": 1.79,
      "site_grid": 1.53,
      "operations": 3.32,
      "total": 23.37,
      "electricity_usd_2026_kwh": 0.1941,
      "wacc": 0.0356,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.89,
      "electricity": 2.29,
      "site_grid": 1.82,
      "operations": 6.56,
      "total": 31.56,
      "electricity_usd_2026_kwh": 0.1941,
      "wacc": 0.0356,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.86,
      "electricity": 4.84,
      "site_grid": 3.27,
      "operations": 7.7,
      "total": 51.67,
      "electricity_usd_2026_kwh": 0.1941,
      "wacc": 0.0356,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.76,
      "electricity": 6.2,
      "site_grid": 3.89,
      "operations": 15.28,
      "total": 70.13,
      "electricity_usd_2026_kwh": 0.1941,
      "wacc": 0.0356,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.33,
      "electricity": 11.4,
      "site_grid": 7.23,
      "operations": 18.33,
      "total": 116.3,
      "electricity_usd_2026_kwh": 0.1941,
      "wacc": 0.0356,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.02,
      "electricity": 14.61,
      "site_grid": 8.62,
      "operations": 36.49,
      "total": 158.74,
      "electricity_usd_2026_kwh": 0.1941,
      "wacc": 0.0356,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.77,
      "electricity": 2.25,
      "site_grid": 1.55,
      "operations": 3.32,
      "total": 23.9,
      "electricity_usd_2026_kwh": 0.2447,
      "wacc": 0.0412,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.11,
      "electricity": 2.89,
      "site_grid": 1.89,
      "operations": 6.56,
      "total": 32.45,
      "electricity_usd_2026_kwh": 0.2447,
      "wacc": 0.0412,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.94,
      "electricity": 6.11,
      "site_grid": 3.31,
      "operations": 7.7,
      "total": 53.06,
      "electricity_usd_2026_kwh": 0.2447,
      "wacc": 0.0412,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.23,
      "electricity": 7.82,
      "site_grid": 4.04,
      "operations": 15.28,
      "total": 72.38,
      "electricity_usd_2026_kwh": 0.2447,
      "wacc": 0.0412,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.51,
      "electricity": 14.38,
      "site_grid": 7.33,
      "operations": 18.33,
      "total": 119.55,
      "electricity_usd_2026_kwh": 0.2447,
      "wacc": 0.0412,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.07,
      "electricity": 18.43,
      "site_grid": 8.95,
      "operations": 36.49,
      "total": 163.94,
      "electricity_usd_2026_kwh": 0.2447,
      "wacc": 0.0412,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.26,
      "electricity": 2.76,
      "site_grid": 1.95,
      "operations": 3.32,
      "total": 25.29,
      "electricity_usd_2026_kwh": 0.3005,
      "wacc": 0.0562,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.72,
      "electricity": 3.54,
      "site_grid": 2.33,
      "operations": 6.56,
      "total": 34.15,
      "electricity_usd_2026_kwh": 0.3005,
      "wacc": 0.0562,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.97,
      "electricity": 7.5,
      "site_grid": 4.17,
      "operations": 7.7,
      "total": 56.35,
      "electricity_usd_2026_kwh": 0.3005,
      "wacc": 0.0562,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.53,
      "electricity": 9.6,
      "site_grid": 4.99,
      "operations": 15.28,
      "total": 76.4,
      "electricity_usd_2026_kwh": 0.3005,
      "wacc": 0.0562,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.8,
      "electricity": 17.65,
      "site_grid": 9.24,
      "operations": 18.33,
      "total": 127.02,
      "electricity_usd_2026_kwh": 0.3005,
      "wacc": 0.0562,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.94,
      "electricity": 22.62,
      "site_grid": 11.03,
      "operations": 36.49,
      "total": 173.08,
      "electricity_usd_2026_kwh": 0.3005,
      "wacc": 0.0562,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.58,
      "electricity": 2.92,
      "site_grid": 2.16,
      "operations": 3.32,
      "total": 25.98,
      "electricity_usd_2026_kwh": 0.3174,
      "wacc": 0.0663,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.12,
      "electricity": 3.74,
      "site_grid": 2.54,
      "operations": 6.56,
      "total": 34.97,
      "electricity_usd_2026_kwh": 0.3174,
      "wacc": 0.0663,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.67,
      "electricity": 7.92,
      "site_grid": 4.62,
      "operations": 7.7,
      "total": 57.91,
      "electricity_usd_2026_kwh": 0.3174,
      "wacc": 0.0663,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.4,
      "electricity": 10.15,
      "site_grid": 5.44,
      "operations": 15.28,
      "total": 78.27,
      "electricity_usd_2026_kwh": 0.3174,
      "wacc": 0.0663,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.35,
      "electricity": 18.65,
      "site_grid": 10.22,
      "operations": 18.33,
      "total": 130.54,
      "electricity_usd_2026_kwh": 0.3174,
      "wacc": 0.0663,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.87,
      "electricity": 23.89,
      "site_grid": 12.04,
      "operations": 36.49,
      "total": 177.3,
      "electricity_usd_2026_kwh": 0.3174,
      "wacc": 0.0663,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.66,
      "electricity": 2.68,
      "site_grid": 2.12,
      "operations": 3.32,
      "total": 25.79,
      "electricity_usd_2026_kwh": 0.2914,
      "wacc": 0.0688,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.23,
      "electricity": 3.44,
      "site_grid": 2.49,
      "operations": 6.56,
      "total": 34.72,
      "electricity_usd_2026_kwh": 0.2914,
      "wacc": 0.0688,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.85,
      "electricity": 7.27,
      "site_grid": 4.55,
      "operations": 7.7,
      "total": 57.37,
      "electricity_usd_2026_kwh": 0.2914,
      "wacc": 0.0688,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.62,
      "electricity": 9.32,
      "site_grid": 5.34,
      "operations": 15.28,
      "total": 77.55,
      "electricity_usd_2026_kwh": 0.2914,
      "wacc": 0.0688,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.73,
      "electricity": 17.12,
      "site_grid": 10.06,
      "operations": 18.33,
      "total": 129.24,
      "electricity_usd_2026_kwh": 0.2914,
      "wacc": 0.0688,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.35,
      "electricity": 21.94,
      "site_grid": 11.81,
      "operations": 36.49,
      "total": 175.6,
      "electricity_usd_2026_kwh": 0.2914,
      "wacc": 0.0688,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.69,
      "electricity": 2.83,
      "site_grid": 2.11,
      "operations": 3.32,
      "total": 25.95,
      "electricity_usd_2026_kwh": 0.3072,
      "wacc": 0.0696,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.26,
      "electricity": 3.62,
      "site_grid": 2.47,
      "operations": 6.56,
      "total": 34.92,
      "electricity_usd_2026_kwh": 0.3072,
      "wacc": 0.0696,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.91,
      "electricity": 7.66,
      "site_grid": 4.51,
      "operations": 7.7,
      "total": 57.79,
      "electricity_usd_2026_kwh": 0.3072,
      "wacc": 0.0696,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.69,
      "electricity": 9.82,
      "site_grid": 5.3,
      "operations": 15.28,
      "total": 78.09,
      "electricity_usd_2026_kwh": 0.3072,
      "wacc": 0.0696,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.86,
      "electricity": 18.05,
      "site_grid": 9.98,
      "operations": 18.33,
      "total": 130.23,
      "electricity_usd_2026_kwh": 0.3072,
      "wacc": 0.0696,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.52,
      "electricity": 23.13,
      "site_grid": 11.72,
      "operations": 36.49,
      "total": 176.85,
      "electricity_usd_2026_kwh": 0.3072,
      "wacc": 0.0696,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.7,
      "electricity": 2.69,
      "site_grid": 2.12,
      "operations": 3.32,
      "total": 25.84,
      "electricity_usd_2026_kwh": 0.2926,
      "wacc": 0.07,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.28,
      "electricity": 3.45,
      "site_grid": 2.48,
      "operations": 6.56,
      "total": 34.77,
      "electricity_usd_2026_kwh": 0.2926,
      "wacc": 0.07,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.93,
      "electricity": 7.3,
      "site_grid": 4.54,
      "operations": 7.7,
      "total": 57.47,
      "electricity_usd_2026_kwh": 0.2926,
      "wacc": 0.07,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.73,
      "electricity": 9.35,
      "site_grid": 5.32,
      "operations": 15.28,
      "total": 77.68,
      "electricity_usd_2026_kwh": 0.2926,
      "wacc": 0.07,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.92,
      "electricity": 17.19,
      "site_grid": 10.04,
      "operations": 18.33,
      "total": 129.48,
      "electricity_usd_2026_kwh": 0.2926,
      "wacc": 0.07,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.59,
      "electricity": 22.03,
      "site_grid": 11.77,
      "operations": 36.49,
      "total": 175.88,
      "electricity_usd_2026_kwh": 0.2926,
      "wacc": 0.07,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.2,
      "electricity": 2.79,
      "site_grid": 1.5,
      "operations": 3.34,
      "total": 25.83,
      "electricity_usd_2026_kwh": 0.2846,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.92,
      "electricity": 3.57,
      "site_grid": 1.5,
      "operations": 6.1,
      "total": 34.1,
      "electricity_usd_2026_kwh": 0.2846,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.99,
      "electricity": 7.57,
      "site_grid": 3.22,
      "operations": 7.74,
      "total": 57.51,
      "electricity_usd_2026_kwh": 0.2846,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.11,
      "electricity": 9.69,
      "site_grid": 3.21,
      "operations": 14.29,
      "total": 76.31,
      "electricity_usd_2026_kwh": 0.2846,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.25,
      "electricity": 17.82,
      "site_grid": 7.12,
      "operations": 18.42,
      "total": 129.61,
      "electricity_usd_2026_kwh": 0.2846,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.65,
      "electricity": 22.82,
      "site_grid": 7.11,
      "operations": 34.32,
      "total": 172.9,
      "electricity_usd_2026_kwh": 0.2846,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.32,
      "electricity": 3.19,
      "site_grid": 1.52,
      "operations": 3.34,
      "total": 26.37,
      "electricity_usd_2026_kwh": 0.3256,
      "wacc": 0.0725,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.08,
      "electricity": 4.09,
      "site_grid": 1.51,
      "operations": 6.1,
      "total": 34.78,
      "electricity_usd_2026_kwh": 0.3256,
      "wacc": 0.0725,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.25,
      "electricity": 8.66,
      "site_grid": 3.25,
      "operations": 7.74,
      "total": 58.9,
      "electricity_usd_2026_kwh": 0.3256,
      "wacc": 0.0725,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.44,
      "electricity": 11.09,
      "site_grid": 3.23,
      "operations": 14.29,
      "total": 78.05,
      "electricity_usd_2026_kwh": 0.3256,
      "wacc": 0.0725,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.83,
      "electricity": 20.38,
      "site_grid": 7.2,
      "operations": 18.42,
      "total": 132.83,
      "electricity_usd_2026_kwh": 0.3256,
      "wacc": 0.0725,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.38,
      "electricity": 26.11,
      "site_grid": 7.15,
      "operations": 34.32,
      "total": 176.96,
      "electricity_usd_2026_kwh": 0.3256,
      "wacc": 0.0725,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.33,
      "electricity": 3.11,
      "site_grid": 1.53,
      "operations": 3.34,
      "total": 26.3,
      "electricity_usd_2026_kwh": 0.3169,
      "wacc": 0.0727,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.09,
      "electricity": 3.98,
      "site_grid": 1.52,
      "operations": 6.1,
      "total": 34.69,
      "electricity_usd_2026_kwh": 0.3169,
      "wacc": 0.0727,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.26,
      "electricity": 8.43,
      "site_grid": 3.28,
      "operations": 7.74,
      "total": 58.71,
      "electricity_usd_2026_kwh": 0.3169,
      "wacc": 0.0727,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.46,
      "electricity": 10.79,
      "site_grid": 3.25,
      "operations": 14.29,
      "total": 77.8,
      "electricity_usd_2026_kwh": 0.3169,
      "wacc": 0.0727,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.87,
      "electricity": 19.84,
      "site_grid": 7.25,
      "operations": 18.42,
      "total": 132.37,
      "electricity_usd_2026_kwh": 0.3169,
      "wacc": 0.0727,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.43,
      "electricity": 25.41,
      "site_grid": 7.2,
      "operations": 34.32,
      "total": 176.35,
      "electricity_usd_2026_kwh": 0.3169,
      "wacc": 0.0727,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.31,
      "electricity": 3.14,
      "site_grid": 1.54,
      "operations": 3.34,
      "total": 26.33,
      "electricity_usd_2026_kwh": 0.3202,
      "wacc": 0.0722,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.06,
      "electricity": 4.02,
      "site_grid": 1.53,
      "operations": 6.1,
      "total": 34.71,
      "electricity_usd_2026_kwh": 0.3202,
      "wacc": 0.0722,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.23,
      "electricity": 8.51,
      "site_grid": 3.29,
      "operations": 7.74,
      "total": 58.77,
      "electricity_usd_2026_kwh": 0.3202,
      "wacc": 0.0722,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.41,
      "electricity": 10.9,
      "site_grid": 3.27,
      "operations": 14.29,
      "total": 77.88,
      "electricity_usd_2026_kwh": 0.3202,
      "wacc": 0.0722,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.78,
      "electricity": 20.04,
      "site_grid": 7.28,
      "operations": 18.42,
      "total": 132.53,
      "electricity_usd_2026_kwh": 0.3202,
      "wacc": 0.0722,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.32,
      "electricity": 25.67,
      "site_grid": 7.24,
      "operations": 34.32,
      "total": 176.55,
      "electricity_usd_2026_kwh": 0.3202,
      "wacc": 0.0722,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.14,
      "electricity": 3.14,
      "site_grid": 1.51,
      "operations": 3.34,
      "total": 26.13,
      "electricity_usd_2026_kwh": 0.3206,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.85,
      "electricity": 4.03,
      "site_grid": 1.51,
      "operations": 6.1,
      "total": 34.49,
      "electricity_usd_2026_kwh": 0.3206,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.86,
      "electricity": 8.52,
      "site_grid": 3.23,
      "operations": 7.74,
      "total": 58.36,
      "electricity_usd_2026_kwh": 0.3206,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.95,
      "electricity": 10.92,
      "site_grid": 3.23,
      "operations": 14.29,
      "total": 77.4,
      "electricity_usd_2026_kwh": 0.3206,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.97,
      "electricity": 20.07,
      "site_grid": 7.15,
      "operations": 18.42,
      "total": 131.62,
      "electricity_usd_2026_kwh": 0.3206,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.31,
      "electricity": 25.71,
      "site_grid": 7.15,
      "operations": 34.32,
      "total": 175.48,
      "electricity_usd_2026_kwh": 0.3206,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.84,
      "electricity": 2.43,
      "site_grid": 1.45,
      "operations": 3.34,
      "total": 25.06,
      "electricity_usd_2026_kwh": 0.2481,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.47,
      "electricity": 3.12,
      "site_grid": 1.46,
      "operations": 6.1,
      "total": 33.15,
      "electricity_usd_2026_kwh": 0.2481,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.21,
      "electricity": 6.6,
      "site_grid": 3.1,
      "operations": 7.74,
      "total": 55.65,
      "electricity_usd_2026_kwh": 0.2481,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.15,
      "electricity": 8.45,
      "site_grid": 3.13,
      "operations": 14.29,
      "total": 74.02,
      "electricity_usd_2026_kwh": 0.2481,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.54,
      "electricity": 15.53,
      "site_grid": 6.86,
      "operations": 18.42,
      "total": 125.35,
      "electricity_usd_2026_kwh": 0.2481,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.52,
      "electricity": 19.89,
      "site_grid": 6.93,
      "operations": 34.32,
      "total": 167.66,
      "electricity_usd_2026_kwh": 0.2481,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.74,
      "electricity": 2.3,
      "site_grid": 1.41,
      "operations": 3.34,
      "total": 24.79,
      "electricity_usd_2026_kwh": 0.2349,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.35,
      "electricity": 2.95,
      "site_grid": 1.43,
      "operations": 6.1,
      "total": 32.83,
      "electricity_usd_2026_kwh": 0.2349,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.0,
      "electricity": 6.25,
      "site_grid": 3.02,
      "operations": 7.74,
      "total": 55.0,
      "electricity_usd_2026_kwh": 0.2349,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.88,
      "electricity": 8.0,
      "site_grid": 3.06,
      "operations": 14.29,
      "total": 73.23,
      "electricity_usd_2026_kwh": 0.2349,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.07,
      "electricity": 14.71,
      "site_grid": 6.67,
      "operations": 18.42,
      "total": 123.87,
      "electricity_usd_2026_kwh": 0.2349,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.92,
      "electricity": 18.84,
      "site_grid": 6.78,
      "operations": 34.32,
      "total": 165.86,
      "electricity_usd_2026_kwh": 0.2349,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.9,
      "electricity": 2.19,
      "site_grid": 1.46,
      "operations": 3.34,
      "total": 24.89,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.55,
      "electricity": 2.8,
      "site_grid": 1.47,
      "operations": 6.1,
      "total": 32.93,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.35,
      "electricity": 5.93,
      "site_grid": 3.13,
      "operations": 7.74,
      "total": 55.15,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.32,
      "electricity": 7.59,
      "site_grid": 3.16,
      "operations": 14.29,
      "total": 73.36,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.85,
      "electricity": 13.96,
      "site_grid": 6.93,
      "operations": 18.42,
      "total": 124.15,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.9,
      "electricity": 17.88,
      "site_grid": 6.99,
      "operations": 34.32,
      "total": 166.08,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.09,
      "electricity": 2.18,
      "site_grid": 1.55,
      "operations": 3.34,
      "total": 25.17,
      "electricity_usd_2026_kwh": 0.2221,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.8,
      "electricity": 2.79,
      "site_grid": 1.56,
      "operations": 6.1,
      "total": 33.24,
      "electricity_usd_2026_kwh": 0.2221,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.77,
      "electricity": 5.9,
      "site_grid": 3.33,
      "operations": 7.74,
      "total": 55.74,
      "electricity_usd_2026_kwh": 0.2221,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.84,
      "electricity": 7.56,
      "site_grid": 3.33,
      "operations": 14.29,
      "total": 74.03,
      "electricity_usd_2026_kwh": 0.2221,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.77,
      "electricity": 13.9,
      "site_grid": 7.37,
      "operations": 18.42,
      "total": 125.46,
      "electricity_usd_2026_kwh": 0.2221,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.05,
      "electricity": 17.81,
      "site_grid": 7.38,
      "operations": 34.32,
      "total": 167.55,
      "electricity_usd_2026_kwh": 0.2221,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.84,
      "electricity": 2.32,
      "site_grid": 1.54,
      "operations": 3.34,
      "total": 25.03,
      "electricity_usd_2026_kwh": 0.2363,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.47,
      "electricity": 2.97,
      "site_grid": 1.55,
      "operations": 6.1,
      "total": 33.1,
      "electricity_usd_2026_kwh": 0.2363,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.22,
      "electricity": 6.28,
      "site_grid": 3.29,
      "operations": 7.74,
      "total": 55.53,
      "electricity_usd_2026_kwh": 0.2363,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.15,
      "electricity": 8.04,
      "site_grid": 3.33,
      "operations": 14.29,
      "total": 73.81,
      "electricity_usd_2026_kwh": 0.2363,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.55,
      "electricity": 14.79,
      "site_grid": 7.28,
      "operations": 18.42,
      "total": 125.04,
      "electricity_usd_2026_kwh": 0.2363,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.52,
      "electricity": 18.95,
      "site_grid": 7.36,
      "operations": 34.32,
      "total": 167.15,
      "electricity_usd_2026_kwh": 0.2363,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.42,
      "electricity": 2.16,
      "site_grid": 1.43,
      "operations": 3.34,
      "total": 24.35,
      "electricity_usd_2026_kwh": 0.22,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.95,
      "electricity": 2.76,
      "site_grid": 1.47,
      "operations": 6.1,
      "total": 32.29,
      "electricity_usd_2026_kwh": 0.22,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.33,
      "electricity": 5.85,
      "site_grid": 3.07,
      "operations": 7.74,
      "total": 53.98,
      "electricity_usd_2026_kwh": 0.22,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.04,
      "electricity": 7.49,
      "site_grid": 3.15,
      "operations": 14.29,
      "total": 71.97,
      "electricity_usd_2026_kwh": 0.22,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.58,
      "electricity": 13.77,
      "site_grid": 6.78,
      "operations": 18.42,
      "total": 121.56,
      "electricity_usd_2026_kwh": 0.22,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.06,
      "electricity": 17.64,
      "site_grid": 6.98,
      "operations": 34.32,
      "total": 162.99,
      "electricity_usd_2026_kwh": 0.22,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.61,
      "electricity": 2.43,
      "site_grid": 1.5,
      "operations": 3.34,
      "total": 24.88,
      "electricity_usd_2026_kwh": 0.248,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.18,
      "electricity": 3.11,
      "site_grid": 1.53,
      "operations": 6.1,
      "total": 32.93,
      "electricity_usd_2026_kwh": 0.248,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.72,
      "electricity": 6.59,
      "site_grid": 3.2,
      "operations": 7.74,
      "total": 55.26,
      "electricity_usd_2026_kwh": 0.248,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.53,
      "electricity": 8.44,
      "site_grid": 3.27,
      "operations": 14.29,
      "total": 73.54,
      "electricity_usd_2026_kwh": 0.248,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.46,
      "electricity": 15.53,
      "site_grid": 7.09,
      "operations": 18.42,
      "total": 124.49,
      "electricity_usd_2026_kwh": 0.248,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.16,
      "electricity": 19.89,
      "site_grid": 7.24,
      "operations": 34.32,
      "total": 166.6,
      "electricity_usd_2026_kwh": 0.248,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.11,
      "electricity": 3.44,
      "site_grid": 1.88,
      "operations": 3.34,
      "total": 26.76,
      "electricity_usd_2026_kwh": 0.3507,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.81,
      "electricity": 4.41,
      "site_grid": 1.88,
      "operations": 6.1,
      "total": 35.2,
      "electricity_usd_2026_kwh": 0.3507,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.8,
      "electricity": 9.32,
      "site_grid": 4.02,
      "operations": 7.74,
      "total": 59.88,
      "electricity_usd_2026_kwh": 0.3507,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.87,
      "electricity": 11.94,
      "site_grid": 4.02,
      "operations": 14.29,
      "total": 79.13,
      "electricity_usd_2026_kwh": 0.3507,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.83,
      "electricity": 21.96,
      "site_grid": 8.89,
      "operations": 18.42,
      "total": 135.1,
      "electricity_usd_2026_kwh": 0.3507,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.13,
      "electricity": 28.12,
      "site_grid": 8.9,
      "operations": 34.32,
      "total": 179.47,
      "electricity_usd_2026_kwh": 0.3507,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.45,
      "electricity": 2.72,
      "site_grid": 2.07,
      "operations": 3.34,
      "total": 26.58,
      "electricity_usd_2026_kwh": 0.2774,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.24,
      "electricity": 3.48,
      "site_grid": 2.05,
      "operations": 6.1,
      "total": 34.87,
      "electricity_usd_2026_kwh": 0.2774,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.52,
      "electricity": 7.38,
      "site_grid": 4.44,
      "operations": 7.74,
      "total": 59.07,
      "electricity_usd_2026_kwh": 0.2774,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.78,
      "electricity": 9.45,
      "site_grid": 4.39,
      "operations": 14.29,
      "total": 77.91,
      "electricity_usd_2026_kwh": 0.2774,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.43,
      "electricity": 17.37,
      "site_grid": 9.81,
      "operations": 18.42,
      "total": 133.03,
      "electricity_usd_2026_kwh": 0.2774,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.14,
      "electricity": 22.25,
      "site_grid": 9.7,
      "operations": 34.32,
      "total": 176.4,
      "electricity_usd_2026_kwh": 0.2774,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.53,
      "electricity": 2.44,
      "site_grid": 2.04,
      "operations": 3.34,
      "total": 26.35,
      "electricity_usd_2026_kwh": 0.2488,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.34,
      "electricity": 3.12,
      "site_grid": 2.01,
      "operations": 6.1,
      "total": 34.57,
      "electricity_usd_2026_kwh": 0.2488,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.7,
      "electricity": 6.61,
      "site_grid": 4.36,
      "operations": 7.74,
      "total": 58.42,
      "electricity_usd_2026_kwh": 0.2488,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.01,
      "electricity": 8.47,
      "site_grid": 4.3,
      "operations": 14.29,
      "total": 77.07,
      "electricity_usd_2026_kwh": 0.2488,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.83,
      "electricity": 15.58,
      "site_grid": 9.65,
      "operations": 18.42,
      "total": 131.48,
      "electricity_usd_2026_kwh": 0.2488,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.63,
      "electricity": 19.95,
      "site_grid": 9.52,
      "operations": 34.32,
      "total": 174.41,
      "electricity_usd_2026_kwh": 0.2488,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.56,
      "electricity": 2.58,
      "site_grid": 2.02,
      "operations": 3.34,
      "total": 26.5,
      "electricity_usd_2026_kwh": 0.2633,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.38,
      "electricity": 3.31,
      "site_grid": 1.99,
      "operations": 6.1,
      "total": 34.78,
      "electricity_usd_2026_kwh": 0.2633,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.76,
      "electricity": 7.0,
      "site_grid": 4.33,
      "operations": 7.74,
      "total": 58.83,
      "electricity_usd_2026_kwh": 0.2633,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.08,
      "electricity": 8.97,
      "site_grid": 4.27,
      "operations": 14.29,
      "total": 77.61,
      "electricity_usd_2026_kwh": 0.2633,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.97,
      "electricity": 16.48,
      "site_grid": 9.58,
      "operations": 18.42,
      "total": 132.45,
      "electricity_usd_2026_kwh": 0.2633,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.8,
      "electricity": 21.11,
      "site_grid": 9.44,
      "operations": 34.32,
      "total": 175.67,
      "electricity_usd_2026_kwh": 0.2633,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.57,
      "electricity": 2.48,
      "site_grid": 2.03,
      "operations": 3.34,
      "total": 26.42,
      "electricity_usd_2026_kwh": 0.2526,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.39,
      "electricity": 3.17,
      "site_grid": 2.0,
      "operations": 6.1,
      "total": 34.67,
      "electricity_usd_2026_kwh": 0.2526,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.79,
      "electricity": 6.72,
      "site_grid": 4.35,
      "operations": 7.74,
      "total": 58.6,
      "electricity_usd_2026_kwh": 0.2526,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.12,
      "electricity": 8.6,
      "site_grid": 4.28,
      "operations": 14.29,
      "total": 77.3,
      "electricity_usd_2026_kwh": 0.2526,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.03,
      "electricity": 15.82,
      "site_grid": 9.63,
      "operations": 18.42,
      "total": 131.89,
      "electricity_usd_2026_kwh": 0.2526,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.88,
      "electricity": 20.26,
      "site_grid": 9.48,
      "operations": 34.32,
      "total": 174.93,
      "electricity_usd_2026_kwh": 0.2526,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.56,
      "electricity": 1.67,
      "site_grid": 1.32,
      "operations": 3.24,
      "total": 24.78,
      "electricity_usd_2026_kwh": 0.1806,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.42,
      "electricity": 2.14,
      "site_grid": 1.17,
      "operations": 5.58,
      "total": 32.31,
      "electricity_usd_2026_kwh": 0.1806,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.76,
      "electricity": 4.51,
      "site_grid": 2.83,
      "operations": 7.52,
      "total": 54.63,
      "electricity_usd_2026_kwh": 0.1806,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.18,
      "electricity": 5.8,
      "site_grid": 2.5,
      "operations": 13.18,
      "total": 71.66,
      "electricity_usd_2026_kwh": 0.1806,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.97,
      "electricity": 10.63,
      "site_grid": 6.26,
      "operations": 17.93,
      "total": 122.79,
      "electricity_usd_2026_kwh": 0.1806,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.02,
      "electricity": 13.66,
      "site_grid": 5.53,
      "operations": 31.87,
      "total": 162.07,
      "electricity_usd_2026_kwh": 0.1806,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.41,
      "electricity": 1.97,
      "site_grid": 1.27,
      "operations": 3.24,
      "total": 24.88,
      "electricity_usd_2026_kwh": 0.2133,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.24,
      "electricity": 2.53,
      "site_grid": 1.12,
      "operations": 5.58,
      "total": 32.47,
      "electricity_usd_2026_kwh": 0.2133,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.45,
      "electricity": 5.33,
      "site_grid": 2.71,
      "operations": 7.52,
      "total": 55.01,
      "electricity_usd_2026_kwh": 0.2133,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.79,
      "electricity": 6.85,
      "site_grid": 2.41,
      "operations": 13.18,
      "total": 72.23,
      "electricity_usd_2026_kwh": 0.2133,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.28,
      "electricity": 12.55,
      "site_grid": 6.0,
      "operations": 17.93,
      "total": 123.76,
      "electricity_usd_2026_kwh": 0.2133,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.15,
      "electricity": 16.14,
      "site_grid": 5.33,
      "operations": 31.87,
      "total": 163.47,
      "electricity_usd_2026_kwh": 0.2133,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.08,
      "electricity": 1.89,
      "site_grid": 1.19,
      "operations": 3.24,
      "total": 24.4,
      "electricity_usd_2026_kwh": 0.2047,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.82,
      "electricity": 2.43,
      "site_grid": 1.07,
      "operations": 5.58,
      "total": 31.9,
      "electricity_usd_2026_kwh": 0.2047,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.74,
      "electricity": 5.12,
      "site_grid": 2.56,
      "operations": 7.52,
      "total": 53.93,
      "electricity_usd_2026_kwh": 0.2047,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.9,
      "electricity": 6.58,
      "site_grid": 2.3,
      "operations": 13.18,
      "total": 70.95,
      "electricity_usd_2026_kwh": 0.2047,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.71,
      "electricity": 12.05,
      "site_grid": 5.65,
      "operations": 17.93,
      "total": 121.34,
      "electricity_usd_2026_kwh": 0.2047,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.18,
      "electricity": 15.49,
      "site_grid": 5.08,
      "operations": 31.87,
      "total": 160.61,
      "electricity_usd_2026_kwh": 0.2047,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.27,
      "electricity": 1.98,
      "site_grid": 1.25,
      "operations": 3.24,
      "total": 24.73,
      "electricity_usd_2026_kwh": 0.2145,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.05,
      "electricity": 2.54,
      "site_grid": 1.11,
      "operations": 5.58,
      "total": 32.29,
      "electricity_usd_2026_kwh": 0.2145,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.14,
      "electricity": 5.36,
      "site_grid": 2.67,
      "operations": 7.52,
      "total": 54.69,
      "electricity_usd_2026_kwh": 0.2145,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.39,
      "electricity": 6.89,
      "site_grid": 2.39,
      "operations": 13.18,
      "total": 71.85,
      "electricity_usd_2026_kwh": 0.2145,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.58,
      "electricity": 12.63,
      "site_grid": 5.91,
      "operations": 17.93,
      "total": 123.06,
      "electricity_usd_2026_kwh": 0.2145,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.28,
      "electricity": 16.23,
      "site_grid": 5.28,
      "operations": 31.87,
      "total": 162.65,
      "electricity_usd_2026_kwh": 0.2145,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.33,
      "electricity": 2.01,
      "site_grid": 1.28,
      "operations": 3.24,
      "total": 24.87,
      "electricity_usd_2026_kwh": 0.2184,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.13,
      "electricity": 2.59,
      "site_grid": 1.14,
      "operations": 5.58,
      "total": 32.45,
      "electricity_usd_2026_kwh": 0.2184,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.27,
      "electricity": 5.46,
      "site_grid": 2.75,
      "operations": 7.52,
      "total": 55.0,
      "electricity_usd_2026_kwh": 0.2184,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.57,
      "electricity": 7.02,
      "site_grid": 2.45,
      "operations": 13.18,
      "total": 72.21,
      "electricity_usd_2026_kwh": 0.2184,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.89,
      "electricity": 12.86,
      "site_grid": 6.08,
      "operations": 17.93,
      "total": 123.76,
      "electricity_usd_2026_kwh": 0.2184,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.66,
      "electricity": 16.53,
      "site_grid": 5.42,
      "operations": 31.87,
      "total": 163.47,
      "electricity_usd_2026_kwh": 0.2184,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.19,
      "electricity": 1.69,
      "site_grid": 1.27,
      "operations": 3.24,
      "total": 24.39,
      "electricity_usd_2026_kwh": 0.1828,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.96,
      "electricity": 2.17,
      "site_grid": 1.14,
      "operations": 5.58,
      "total": 31.85,
      "electricity_usd_2026_kwh": 0.1828,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.98,
      "electricity": 4.57,
      "site_grid": 2.73,
      "operations": 7.52,
      "total": 53.8,
      "electricity_usd_2026_kwh": 0.1828,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.2,
      "electricity": 5.87,
      "site_grid": 2.44,
      "operations": 13.18,
      "total": 70.69,
      "electricity_usd_2026_kwh": 0.1828,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.24,
      "electricity": 10.76,
      "site_grid": 6.03,
      "operations": 17.93,
      "total": 120.96,
      "electricity_usd_2026_kwh": 0.1828,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.85,
      "electricity": 13.83,
      "site_grid": 5.4,
      "operations": 31.87,
      "total": 159.94,
      "electricity_usd_2026_kwh": 0.1828,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.09,
      "electricity": 1.66,
      "site_grid": 1.24,
      "operations": 3.24,
      "total": 24.23,
      "electricity_usd_2026_kwh": 0.1804,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.84,
      "electricity": 2.14,
      "site_grid": 1.11,
      "operations": 5.58,
      "total": 31.67,
      "electricity_usd_2026_kwh": 0.1804,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.77,
      "electricity": 4.51,
      "site_grid": 2.65,
      "operations": 7.52,
      "total": 53.45,
      "electricity_usd_2026_kwh": 0.1804,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.93,
      "electricity": 5.79,
      "site_grid": 2.38,
      "operations": 13.18,
      "total": 70.29,
      "electricity_usd_2026_kwh": 0.1804,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.76,
      "electricity": 10.62,
      "site_grid": 5.87,
      "operations": 17.93,
      "total": 120.18,
      "electricity_usd_2026_kwh": 0.1804,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.25,
      "electricity": 13.65,
      "site_grid": 5.27,
      "operations": 31.87,
      "total": 159.03,
      "electricity_usd_2026_kwh": 0.1804,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.26,
      "electricity": 1.64,
      "site_grid": 1.29,
      "operations": 3.24,
      "total": 24.42,
      "electricity_usd_2026_kwh": 0.1781,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.05,
      "electricity": 2.11,
      "site_grid": 1.15,
      "operations": 5.58,
      "total": 31.88,
      "electricity_usd_2026_kwh": 0.1781,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.12,
      "electricity": 4.45,
      "site_grid": 2.75,
      "operations": 7.52,
      "total": 53.85,
      "electricity_usd_2026_kwh": 0.1781,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.37,
      "electricity": 5.72,
      "site_grid": 2.46,
      "operations": 13.18,
      "total": 70.74,
      "electricity_usd_2026_kwh": 0.1781,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.55,
      "electricity": 10.49,
      "site_grid": 6.09,
      "operations": 17.93,
      "total": 121.06,
      "electricity_usd_2026_kwh": 0.1781,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.23,
      "electricity": 13.48,
      "site_grid": 5.44,
      "operations": 31.87,
      "total": 160.01,
      "electricity_usd_2026_kwh": 0.1781,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.46,
      "electricity": 1.5,
      "site_grid": 1.36,
      "operations": 3.24,
      "total": 24.55,
      "electricity_usd_2026_kwh": 0.1622,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.29,
      "electricity": 1.92,
      "site_grid": 1.21,
      "operations": 5.58,
      "total": 32.01,
      "electricity_usd_2026_kwh": 0.1622,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.54,
      "electricity": 4.05,
      "site_grid": 2.92,
      "operations": 7.52,
      "total": 54.04,
      "electricity_usd_2026_kwh": 0.1622,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.9,
      "electricity": 5.21,
      "site_grid": 2.59,
      "operations": 13.18,
      "total": 70.89,
      "electricity_usd_2026_kwh": 0.1622,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.48,
      "electricity": 9.55,
      "site_grid": 6.47,
      "operations": 17.93,
      "total": 121.43,
      "electricity_usd_2026_kwh": 0.1622,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.41,
      "electricity": 12.27,
      "site_grid": 5.74,
      "operations": 31.87,
      "total": 160.27,
      "electricity_usd_2026_kwh": 0.1622,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.2,
      "electricity": 1.42,
      "site_grid": 1.35,
      "operations": 3.24,
      "total": 24.2,
      "electricity_usd_2026_kwh": 0.1536,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.97,
      "electricity": 1.82,
      "site_grid": 1.21,
      "operations": 5.58,
      "total": 31.58,
      "electricity_usd_2026_kwh": 0.1536,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.98,
      "electricity": 3.84,
      "site_grid": 2.89,
      "operations": 7.52,
      "total": 53.24,
      "electricity_usd_2026_kwh": 0.1536,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.2,
      "electricity": 4.94,
      "site_grid": 2.59,
      "operations": 13.18,
      "total": 69.91,
      "electricity_usd_2026_kwh": 0.1536,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.25,
      "electricity": 9.04,
      "site_grid": 6.4,
      "operations": 17.93,
      "total": 119.62,
      "electricity_usd_2026_kwh": 0.1536,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.86,
      "electricity": 11.63,
      "site_grid": 5.73,
      "operations": 31.87,
      "total": 158.07,
      "electricity_usd_2026_kwh": 0.1536,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.77,
      "electricity": 1.4,
      "site_grid": 1.26,
      "operations": 3.24,
      "total": 23.68,
      "electricity_usd_2026_kwh": 0.152,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.44,
      "electricity": 1.8,
      "site_grid": 1.15,
      "operations": 5.58,
      "total": 30.97,
      "electricity_usd_2026_kwh": 0.152,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.08,
      "electricity": 3.8,
      "site_grid": 2.7,
      "operations": 7.52,
      "total": 52.11,
      "electricity_usd_2026_kwh": 0.152,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.07,
      "electricity": 4.88,
      "site_grid": 2.46,
      "operations": 13.18,
      "total": 68.59,
      "electricity_usd_2026_kwh": 0.152,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.25,
      "electricity": 8.95,
      "site_grid": 5.98,
      "operations": 17.93,
      "total": 117.11,
      "electricity_usd_2026_kwh": 0.152,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.35,
      "electricity": 11.5,
      "site_grid": 5.43,
      "operations": 31.87,
      "total": 155.16,
      "electricity_usd_2026_kwh": 0.152,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.96,
      "electricity": 1.57,
      "site_grid": 1.32,
      "operations": 3.24,
      "total": 24.09,
      "electricity_usd_2026_kwh": 0.1705,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.67,
      "electricity": 2.02,
      "site_grid": 1.19,
      "operations": 5.58,
      "total": 31.46,
      "electricity_usd_2026_kwh": 0.1705,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.48,
      "electricity": 4.26,
      "site_grid": 2.82,
      "operations": 7.52,
      "total": 53.09,
      "electricity_usd_2026_kwh": 0.1705,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.58,
      "electricity": 5.48,
      "site_grid": 2.55,
      "operations": 13.18,
      "total": 69.78,
      "electricity_usd_2026_kwh": 0.1705,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.14,
      "electricity": 10.04,
      "site_grid": 6.24,
      "operations": 17.93,
      "total": 119.35,
      "electricity_usd_2026_kwh": 0.1705,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.47,
      "electricity": 12.9,
      "site_grid": 5.63,
      "operations": 31.87,
      "total": 157.87,
      "electricity_usd_2026_kwh": 0.1705,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.47,
      "electricity": 1.87,
      "site_grid": 1.65,
      "operations": 3.24,
      "total": 25.22,
      "electricity_usd_2026_kwh": 0.2026,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.31,
      "electricity": 2.4,
      "site_grid": 1.46,
      "operations": 5.58,
      "total": 32.75,
      "electricity_usd_2026_kwh": 0.2026,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.57,
      "electricity": 5.06,
      "site_grid": 3.53,
      "operations": 7.52,
      "total": 55.69,
      "electricity_usd_2026_kwh": 0.2026,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.94,
      "electricity": 6.51,
      "site_grid": 3.13,
      "operations": 13.18,
      "total": 72.76,
      "electricity_usd_2026_kwh": 0.2026,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.55,
      "electricity": 11.93,
      "site_grid": 7.81,
      "operations": 17.93,
      "total": 125.22,
      "electricity_usd_2026_kwh": 0.2026,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.49,
      "electricity": 15.33,
      "site_grid": 6.92,
      "operations": 31.87,
      "total": 164.6,
      "electricity_usd_2026_kwh": 0.2026,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.81,
      "electricity": 1.61,
      "site_grid": 1.82,
      "operations": 3.24,
      "total": 25.47,
      "electricity_usd_2026_kwh": 0.1745,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.74,
      "electricity": 2.07,
      "site_grid": 1.59,
      "operations": 5.58,
      "total": 32.98,
      "electricity_usd_2026_kwh": 0.1745,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.31,
      "electricity": 4.36,
      "site_grid": 3.89,
      "operations": 7.52,
      "total": 56.08,
      "electricity_usd_2026_kwh": 0.1745,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.86,
      "electricity": 5.61,
      "site_grid": 3.41,
      "operations": 13.18,
      "total": 73.06,
      "electricity_usd_2026_kwh": 0.1745,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.17,
      "electricity": 10.27,
      "site_grid": 8.61,
      "operations": 17.93,
      "total": 125.98,
      "electricity_usd_2026_kwh": 0.1745,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.52,
      "electricity": 13.2,
      "site_grid": 7.54,
      "operations": 31.87,
      "total": 165.13,
      "electricity_usd_2026_kwh": 0.1745,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.9,
      "electricity": 1.54,
      "site_grid": 1.79,
      "operations": 3.24,
      "total": 25.46,
      "electricity_usd_2026_kwh": 0.167,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.85,
      "electricity": 1.98,
      "site_grid": 1.56,
      "operations": 5.58,
      "total": 32.97,
      "electricity_usd_2026_kwh": 0.167,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.49,
      "electricity": 4.17,
      "site_grid": 3.83,
      "operations": 7.52,
      "total": 56.01,
      "electricity_usd_2026_kwh": 0.167,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.09,
      "electricity": 5.36,
      "site_grid": 3.34,
      "operations": 13.18,
      "total": 72.98,
      "electricity_usd_2026_kwh": 0.167,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.57,
      "electricity": 9.83,
      "site_grid": 8.46,
      "operations": 17.93,
      "total": 125.8,
      "electricity_usd_2026_kwh": 0.167,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 113.03,
      "electricity": 12.63,
      "site_grid": 7.39,
      "operations": 31.87,
      "total": 164.92,
      "electricity_usd_2026_kwh": 0.167,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.93,
      "electricity": 1.46,
      "site_grid": 1.77,
      "operations": 3.24,
      "total": 25.4,
      "electricity_usd_2026_kwh": 0.1587,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.88,
      "electricity": 1.88,
      "site_grid": 1.55,
      "operations": 5.58,
      "total": 32.89,
      "electricity_usd_2026_kwh": 0.1587,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.55,
      "electricity": 3.97,
      "site_grid": 3.8,
      "operations": 7.52,
      "total": 55.83,
      "electricity_usd_2026_kwh": 0.1587,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.17,
      "electricity": 5.1,
      "site_grid": 3.31,
      "operations": 13.18,
      "total": 72.76,
      "electricity_usd_2026_kwh": 0.1587,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.71,
      "electricity": 9.34,
      "site_grid": 8.4,
      "operations": 17.93,
      "total": 125.39,
      "electricity_usd_2026_kwh": 0.1587,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 113.2,
      "electricity": 12.01,
      "site_grid": 7.33,
      "operations": 31.87,
      "total": 164.4,
      "electricity_usd_2026_kwh": 0.1587,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.94,
      "electricity": 1.44,
      "site_grid": 1.78,
      "operations": 3.24,
      "total": 25.4,
      "electricity_usd_2026_kwh": 0.1561,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.9,
      "electricity": 1.85,
      "site_grid": 1.55,
      "operations": 5.58,
      "total": 32.88,
      "electricity_usd_2026_kwh": 0.1561,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.58,
      "electricity": 3.9,
      "site_grid": 3.81,
      "operations": 7.52,
      "total": 55.82,
      "electricity_usd_2026_kwh": 0.1561,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.2,
      "electricity": 5.01,
      "site_grid": 3.33,
      "operations": 13.18,
      "total": 72.73,
      "electricity_usd_2026_kwh": 0.1561,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.77,
      "electricity": 9.19,
      "site_grid": 8.44,
      "operations": 17.93,
      "total": 125.33,
      "electricity_usd_2026_kwh": 0.1561,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 113.28,
      "electricity": 11.81,
      "site_grid": 7.36,
      "operations": 31.87,
      "total": 164.31,
      "electricity_usd_2026_kwh": 0.1561,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.28,
      "electricity": 1.89,
      "site_grid": 1.3,
      "operations": 3.21,
      "total": 24.68,
      "electricity_usd_2026_kwh": 0.2051,
      "wacc": 0.0708,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.05,
      "electricity": 2.43,
      "site_grid": 1.16,
      "operations": 5.54,
      "total": 32.19,
      "electricity_usd_2026_kwh": 0.2051,
      "wacc": 0.0708,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.16,
      "electricity": 5.12,
      "site_grid": 2.78,
      "operations": 7.47,
      "total": 54.53,
      "electricity_usd_2026_kwh": 0.2051,
      "wacc": 0.0708,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.39,
      "electricity": 6.58,
      "site_grid": 2.49,
      "operations": 13.1,
      "total": 71.56,
      "electricity_usd_2026_kwh": 0.2051,
      "wacc": 0.0708,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.64,
      "electricity": 12.07,
      "site_grid": 6.15,
      "operations": 17.81,
      "total": 122.66,
      "electricity_usd_2026_kwh": 0.2051,
      "wacc": 0.0708,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.27,
      "electricity": 15.5,
      "site_grid": 5.5,
      "operations": 31.68,
      "total": 161.96,
      "electricity_usd_2026_kwh": 0.2051,
      "wacc": 0.0708,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.13,
      "electricity": 1.97,
      "site_grid": 1.24,
      "operations": 3.21,
      "total": 24.56,
      "electricity_usd_2026_kwh": 0.2135,
      "wacc": 0.0665,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.87,
      "electricity": 2.53,
      "site_grid": 1.12,
      "operations": 5.54,
      "total": 32.06,
      "electricity_usd_2026_kwh": 0.2135,
      "wacc": 0.0665,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.85,
      "electricity": 5.33,
      "site_grid": 2.66,
      "operations": 7.47,
      "total": 54.31,
      "electricity_usd_2026_kwh": 0.2135,
      "wacc": 0.0665,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.0,
      "electricity": 6.85,
      "site_grid": 2.4,
      "operations": 13.1,
      "total": 71.35,
      "electricity_usd_2026_kwh": 0.2135,
      "wacc": 0.0665,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.95,
      "electricity": 12.56,
      "site_grid": 5.9,
      "operations": 17.81,
      "total": 122.21,
      "electricity_usd_2026_kwh": 0.2135,
      "wacc": 0.0665,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.41,
      "electricity": 16.14,
      "site_grid": 5.3,
      "operations": 31.68,
      "total": 161.53,
      "electricity_usd_2026_kwh": 0.2135,
      "wacc": 0.0665,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.81,
      "electricity": 1.95,
      "site_grid": 1.17,
      "operations": 3.21,
      "total": 24.13,
      "electricity_usd_2026_kwh": 0.2112,
      "wacc": 0.0567,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.46,
      "electricity": 2.5,
      "site_grid": 1.07,
      "operations": 5.54,
      "total": 31.57,
      "electricity_usd_2026_kwh": 0.2112,
      "wacc": 0.0567,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.15,
      "electricity": 5.28,
      "site_grid": 2.51,
      "operations": 7.47,
      "total": 53.4,
      "electricity_usd_2026_kwh": 0.2112,
      "wacc": 0.0567,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.12,
      "electricity": 6.78,
      "site_grid": 2.28,
      "operations": 13.1,
      "total": 70.29,
      "electricity_usd_2026_kwh": 0.2112,
      "wacc": 0.0567,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.4,
      "electricity": 12.43,
      "site_grid": 5.55,
      "operations": 17.81,
      "total": 120.19,
      "electricity_usd_2026_kwh": 0.2112,
      "wacc": 0.0567,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.47,
      "electricity": 15.96,
      "site_grid": 5.05,
      "operations": 31.68,
      "total": 159.17,
      "electricity_usd_2026_kwh": 0.2112,
      "wacc": 0.0567,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.99,
      "electricity": 2.13,
      "site_grid": 1.23,
      "operations": 3.21,
      "total": 24.56,
      "electricity_usd_2026_kwh": 0.2316,
      "wacc": 0.0622,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.69,
      "electricity": 2.74,
      "site_grid": 1.11,
      "operations": 5.54,
      "total": 32.08,
      "electricity_usd_2026_kwh": 0.2316,
      "wacc": 0.0622,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.54,
      "electricity": 5.79,
      "site_grid": 2.63,
      "operations": 7.47,
      "total": 54.42,
      "electricity_usd_2026_kwh": 0.2316,
      "wacc": 0.0622,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.61,
      "electricity": 7.43,
      "site_grid": 2.37,
      "operations": 13.1,
      "total": 71.52,
      "electricity_usd_2026_kwh": 0.2316,
      "wacc": 0.0622,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.26,
      "electricity": 13.63,
      "site_grid": 5.81,
      "operations": 17.81,
      "total": 122.51,
      "electricity_usd_2026_kwh": 0.2316,
      "wacc": 0.0622,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.55,
      "electricity": 17.5,
      "site_grid": 5.25,
      "operations": 31.68,
      "total": 161.99,
      "electricity_usd_2026_kwh": 0.2316,
      "wacc": 0.0622,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.05,
      "electricity": 2.0,
      "site_grid": 1.26,
      "operations": 3.21,
      "total": 24.52,
      "electricity_usd_2026_kwh": 0.217,
      "wacc": 0.0641,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.77,
      "electricity": 2.57,
      "site_grid": 1.14,
      "operations": 5.54,
      "total": 32.02,
      "electricity_usd_2026_kwh": 0.217,
      "wacc": 0.0641,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.68,
      "electricity": 5.42,
      "site_grid": 2.7,
      "operations": 7.47,
      "total": 54.26,
      "electricity_usd_2026_kwh": 0.217,
      "wacc": 0.0641,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.78,
      "electricity": 6.97,
      "site_grid": 2.44,
      "operations": 13.1,
      "total": 71.29,
      "electricity_usd_2026_kwh": 0.217,
      "wacc": 0.0641,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.56,
      "electricity": 12.77,
      "site_grid": 5.97,
      "operations": 17.81,
      "total": 122.12,
      "electricity_usd_2026_kwh": 0.217,
      "wacc": 0.0641,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.93,
      "electricity": 16.4,
      "site_grid": 5.39,
      "operations": 31.68,
      "total": 161.41,
      "electricity_usd_2026_kwh": 0.217,
      "wacc": 0.0641,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.92,
      "electricity": 1.42,
      "site_grid": 1.25,
      "operations": 3.21,
      "total": 23.8,
      "electricity_usd_2026_kwh": 0.1537,
      "wacc": 0.0601,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.6,
      "electricity": 1.82,
      "site_grid": 1.13,
      "operations": 5.54,
      "total": 31.1,
      "electricity_usd_2026_kwh": 0.1537,
      "wacc": 0.0601,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.39,
      "electricity": 3.84,
      "site_grid": 2.68,
      "operations": 7.47,
      "total": 52.37,
      "electricity_usd_2026_kwh": 0.1537,
      "wacc": 0.0601,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.42,
      "electricity": 4.93,
      "site_grid": 2.43,
      "operations": 13.1,
      "total": 68.88,
      "electricity_usd_2026_kwh": 0.1537,
      "wacc": 0.0601,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.93,
      "electricity": 9.05,
      "site_grid": 5.92,
      "operations": 17.81,
      "total": 117.7,
      "electricity_usd_2026_kwh": 0.1537,
      "wacc": 0.0601,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.13,
      "electricity": 11.62,
      "site_grid": 5.37,
      "operations": 31.68,
      "total": 155.8,
      "electricity_usd_2026_kwh": 0.1537,
      "wacc": 0.0601,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.82,
      "electricity": 1.28,
      "site_grid": 1.22,
      "operations": 3.21,
      "total": 23.53,
      "electricity_usd_2026_kwh": 0.1389,
      "wacc": 0.0571,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.48,
      "electricity": 1.64,
      "site_grid": 1.11,
      "operations": 5.54,
      "total": 30.77,
      "electricity_usd_2026_kwh": 0.1389,
      "wacc": 0.0571,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.17,
      "electricity": 3.47,
      "site_grid": 2.61,
      "operations": 7.47,
      "total": 51.71,
      "electricity_usd_2026_kwh": 0.1389,
      "wacc": 0.0571,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.15,
      "electricity": 4.46,
      "site_grid": 2.37,
      "operations": 13.1,
      "total": 68.08,
      "electricity_usd_2026_kwh": 0.1389,
      "wacc": 0.0571,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.45,
      "electricity": 8.17,
      "site_grid": 5.76,
      "operations": 17.81,
      "total": 116.2,
      "electricity_usd_2026_kwh": 0.1389,
      "wacc": 0.0571,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.53,
      "electricity": 10.5,
      "site_grid": 5.25,
      "operations": 31.68,
      "total": 153.96,
      "electricity_usd_2026_kwh": 0.1389,
      "wacc": 0.0571,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.98,
      "electricity": 1.17,
      "site_grid": 1.26,
      "operations": 3.21,
      "total": 23.62,
      "electricity_usd_2026_kwh": 0.1266,
      "wacc": 0.062,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.68,
      "electricity": 1.5,
      "site_grid": 1.14,
      "operations": 5.54,
      "total": 30.87,
      "electricity_usd_2026_kwh": 0.1266,
      "wacc": 0.062,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.52,
      "electricity": 3.16,
      "site_grid": 2.7,
      "operations": 7.47,
      "total": 51.86,
      "electricity_usd_2026_kwh": 0.1266,
      "wacc": 0.062,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.59,
      "electricity": 4.06,
      "site_grid": 2.45,
      "operations": 13.1,
      "total": 68.21,
      "electricity_usd_2026_kwh": 0.1266,
      "wacc": 0.062,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.23,
      "electricity": 7.45,
      "site_grid": 5.98,
      "operations": 17.81,
      "total": 116.47,
      "electricity_usd_2026_kwh": 0.1266,
      "wacc": 0.062,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.51,
      "electricity": 9.57,
      "site_grid": 5.41,
      "operations": 31.68,
      "total": 154.18,
      "electricity_usd_2026_kwh": 0.1266,
      "wacc": 0.062,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.18,
      "electricity": 1.24,
      "site_grid": 1.34,
      "operations": 3.21,
      "total": 23.97,
      "electricity_usd_2026_kwh": 0.135,
      "wacc": 0.0678,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.93,
      "electricity": 1.6,
      "site_grid": 1.2,
      "operations": 5.54,
      "total": 31.27,
      "electricity_usd_2026_kwh": 0.135,
      "wacc": 0.0678,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.94,
      "electricity": 3.37,
      "site_grid": 2.87,
      "operations": 7.47,
      "total": 52.65,
      "electricity_usd_2026_kwh": 0.135,
      "wacc": 0.0678,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.12,
      "electricity": 4.33,
      "site_grid": 2.58,
      "operations": 13.1,
      "total": 69.13,
      "electricity_usd_2026_kwh": 0.135,
      "wacc": 0.0678,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.15,
      "electricity": 7.95,
      "site_grid": 6.36,
      "operations": 17.81,
      "total": 118.26,
      "electricity_usd_2026_kwh": 0.135,
      "wacc": 0.0678,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.67,
      "electricity": 10.21,
      "site_grid": 5.71,
      "operations": 31.68,
      "total": 156.26,
      "electricity_usd_2026_kwh": 0.135,
      "wacc": 0.0678,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.92,
      "electricity": 1.25,
      "site_grid": 1.33,
      "operations": 3.21,
      "total": 23.7,
      "electricity_usd_2026_kwh": 0.1355,
      "wacc": 0.0601,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.6,
      "electricity": 1.6,
      "site_grid": 1.2,
      "operations": 5.54,
      "total": 30.95,
      "electricity_usd_2026_kwh": 0.1355,
      "wacc": 0.0601,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.39,
      "electricity": 3.38,
      "site_grid": 2.84,
      "operations": 7.47,
      "total": 52.08,
      "electricity_usd_2026_kwh": 0.1355,
      "wacc": 0.0601,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.43,
      "electricity": 4.35,
      "site_grid": 2.58,
      "operations": 13.1,
      "total": 68.45,
      "electricity_usd_2026_kwh": 0.1355,
      "wacc": 0.0601,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.93,
      "electricity": 7.97,
      "site_grid": 6.28,
      "operations": 17.81,
      "total": 117.0,
      "electricity_usd_2026_kwh": 0.1355,
      "wacc": 0.0601,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.14,
      "electricity": 10.24,
      "site_grid": 5.7,
      "operations": 31.68,
      "total": 154.76,
      "electricity_usd_2026_kwh": 0.1355,
      "wacc": 0.0601,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.5,
      "electricity": 1.32,
      "site_grid": 1.24,
      "operations": 3.21,
      "total": 23.27,
      "electricity_usd_2026_kwh": 0.1436,
      "wacc": 0.0476,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.08,
      "electricity": 1.7,
      "site_grid": 1.14,
      "operations": 5.54,
      "total": 30.47,
      "electricity_usd_2026_kwh": 0.1436,
      "wacc": 0.0476,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.5,
      "electricity": 3.59,
      "site_grid": 2.65,
      "operations": 7.47,
      "total": 51.2,
      "electricity_usd_2026_kwh": 0.1436,
      "wacc": 0.0476,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.31,
      "electricity": 4.61,
      "site_grid": 2.44,
      "operations": 13.1,
      "total": 67.46,
      "electricity_usd_2026_kwh": 0.1436,
      "wacc": 0.0476,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.96,
      "electricity": 8.45,
      "site_grid": 5.86,
      "operations": 17.81,
      "total": 115.08,
      "electricity_usd_2026_kwh": 0.1436,
      "wacc": 0.0476,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.66,
      "electricity": 10.85,
      "site_grid": 5.4,
      "operations": 31.68,
      "total": 152.6,
      "electricity_usd_2026_kwh": 0.1436,
      "wacc": 0.0476,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.69,
      "electricity": 1.62,
      "site_grid": 1.29,
      "operations": 3.21,
      "total": 23.82,
      "electricity_usd_2026_kwh": 0.1762,
      "wacc": 0.0532,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.31,
      "electricity": 2.09,
      "site_grid": 1.18,
      "operations": 5.54,
      "total": 31.13,
      "electricity_usd_2026_kwh": 0.1762,
      "wacc": 0.0532,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.9,
      "electricity": 4.4,
      "site_grid": 2.77,
      "operations": 7.47,
      "total": 52.53,
      "electricity_usd_2026_kwh": 0.1762,
      "wacc": 0.0532,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.81,
      "electricity": 5.66,
      "site_grid": 2.53,
      "operations": 13.1,
      "total": 69.09,
      "electricity_usd_2026_kwh": 0.1762,
      "wacc": 0.0532,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.84,
      "electricity": 10.37,
      "site_grid": 6.13,
      "operations": 17.81,
      "total": 118.14,
      "electricity_usd_2026_kwh": 0.1762,
      "wacc": 0.0532,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.76,
      "electricity": 13.32,
      "site_grid": 5.6,
      "operations": 31.68,
      "total": 156.37,
      "electricity_usd_2026_kwh": 0.1762,
      "wacc": 0.0532,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.19,
      "electricity": 2.8,
      "site_grid": 1.62,
      "operations": 3.21,
      "total": 25.82,
      "electricity_usd_2026_kwh": 0.3033,
      "wacc": 0.0682,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.94,
      "electricity": 3.59,
      "site_grid": 1.45,
      "operations": 5.54,
      "total": 33.53,
      "electricity_usd_2026_kwh": 0.3033,
      "wacc": 0.0682,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.97,
      "electricity": 7.58,
      "site_grid": 3.47,
      "operations": 7.47,
      "total": 57.48,
      "electricity_usd_2026_kwh": 0.3033,
      "wacc": 0.0682,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.15,
      "electricity": 9.73,
      "site_grid": 3.11,
      "operations": 13.1,
      "total": 75.1,
      "electricity_usd_2026_kwh": 0.3033,
      "wacc": 0.0682,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.22,
      "electricity": 17.85,
      "site_grid": 7.68,
      "operations": 17.81,
      "total": 129.55,
      "electricity_usd_2026_kwh": 0.3033,
      "wacc": 0.0682,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.74,
      "electricity": 22.93,
      "site_grid": 6.89,
      "operations": 31.68,
      "total": 170.25,
      "electricity_usd_2026_kwh": 0.3033,
      "wacc": 0.0682,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.53,
      "electricity": 1.78,
      "site_grid": 1.79,
      "operations": 3.21,
      "total": 25.3,
      "electricity_usd_2026_kwh": 0.1929,
      "wacc": 0.0783,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.37,
      "electricity": 2.28,
      "site_grid": 1.58,
      "operations": 5.54,
      "total": 32.78,
      "electricity_usd_2026_kwh": 0.1929,
      "wacc": 0.0783,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.7,
      "electricity": 4.82,
      "site_grid": 3.83,
      "operations": 7.47,
      "total": 55.81,
      "electricity_usd_2026_kwh": 0.1929,
      "wacc": 0.0783,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.06,
      "electricity": 6.19,
      "site_grid": 3.39,
      "operations": 13.1,
      "total": 72.75,
      "electricity_usd_2026_kwh": 0.1929,
      "wacc": 0.0783,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.82,
      "electricity": 11.35,
      "site_grid": 8.46,
      "operations": 17.81,
      "total": 125.45,
      "electricity_usd_2026_kwh": 0.1929,
      "wacc": 0.0783,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.76,
      "electricity": 14.58,
      "site_grid": 7.51,
      "operations": 31.68,
      "total": 164.53,
      "electricity_usd_2026_kwh": 0.1929,
      "wacc": 0.0783,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.61,
      "electricity": 1.75,
      "site_grid": 1.76,
      "operations": 3.21,
      "total": 25.33,
      "electricity_usd_2026_kwh": 0.1897,
      "wacc": 0.0808,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.47,
      "electricity": 2.25,
      "site_grid": 1.55,
      "operations": 5.54,
      "total": 32.82,
      "electricity_usd_2026_kwh": 0.1897,
      "wacc": 0.0808,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.88,
      "electricity": 4.74,
      "site_grid": 3.76,
      "operations": 7.47,
      "total": 55.84,
      "electricity_usd_2026_kwh": 0.1897,
      "wacc": 0.0808,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.29,
      "electricity": 6.09,
      "site_grid": 3.33,
      "operations": 13.1,
      "total": 72.81,
      "electricity_usd_2026_kwh": 0.1897,
      "wacc": 0.0808,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.22,
      "electricity": 11.16,
      "site_grid": 8.32,
      "operations": 17.81,
      "total": 125.52,
      "electricity_usd_2026_kwh": 0.1897,
      "wacc": 0.0808,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.26,
      "electricity": 14.34,
      "site_grid": 7.36,
      "operations": 31.68,
      "total": 164.64,
      "electricity_usd_2026_kwh": 0.1897,
      "wacc": 0.0808,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.64,
      "electricity": 1.71,
      "site_grid": 1.74,
      "operations": 3.21,
      "total": 25.3,
      "electricity_usd_2026_kwh": 0.1851,
      "wacc": 0.0816,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.51,
      "electricity": 2.19,
      "site_grid": 1.54,
      "operations": 5.54,
      "total": 32.78,
      "electricity_usd_2026_kwh": 0.1851,
      "wacc": 0.0816,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.94,
      "electricity": 4.63,
      "site_grid": 3.73,
      "operations": 7.47,
      "total": 55.76,
      "electricity_usd_2026_kwh": 0.1851,
      "wacc": 0.0816,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.37,
      "electricity": 5.94,
      "site_grid": 3.3,
      "operations": 13.1,
      "total": 72.71,
      "electricity_usd_2026_kwh": 0.1851,
      "wacc": 0.0816,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.36,
      "electricity": 10.89,
      "site_grid": 8.26,
      "operations": 17.81,
      "total": 125.32,
      "electricity_usd_2026_kwh": 0.1851,
      "wacc": 0.0816,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.43,
      "electricity": 13.99,
      "site_grid": 7.3,
      "operations": 31.68,
      "total": 164.4,
      "electricity_usd_2026_kwh": 0.1851,
      "wacc": 0.0816,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.65,
      "electricity": 1.68,
      "site_grid": 1.75,
      "operations": 3.21,
      "total": 25.3,
      "electricity_usd_2026_kwh": 0.1824,
      "wacc": 0.082,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.52,
      "electricity": 2.16,
      "site_grid": 1.55,
      "operations": 5.54,
      "total": 32.78,
      "electricity_usd_2026_kwh": 0.1824,
      "wacc": 0.082,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.97,
      "electricity": 4.56,
      "site_grid": 3.75,
      "operations": 7.47,
      "total": 55.74,
      "electricity_usd_2026_kwh": 0.1824,
      "wacc": 0.082,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.4,
      "electricity": 5.86,
      "site_grid": 3.31,
      "operations": 13.1,
      "total": 72.67,
      "electricity_usd_2026_kwh": 0.1824,
      "wacc": 0.082,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.42,
      "electricity": 10.74,
      "site_grid": 8.3,
      "operations": 17.81,
      "total": 125.26,
      "electricity_usd_2026_kwh": 0.1824,
      "wacc": 0.082,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.5,
      "electricity": 13.79,
      "site_grid": 7.33,
      "operations": 31.68,
      "total": 164.31,
      "electricity_usd_2026_kwh": 0.1824,
      "wacc": 0.082,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.17,
      "electricity": 1.9,
      "site_grid": 1.43,
      "operations": 3.35,
      "total": 23.85,
      "electricity_usd_2026_kwh": 0.2051,
      "wacc": 0.0538,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.6,
      "electricity": 2.44,
      "site_grid": 1.44,
      "operations": 6.67,
      "total": 32.15,
      "electricity_usd_2026_kwh": 0.2051,
      "wacc": 0.0538,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.8,
      "electricity": 5.16,
      "site_grid": 3.06,
      "operations": 7.75,
      "total": 52.77,
      "electricity_usd_2026_kwh": 0.2051,
      "wacc": 0.0538,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.28,
      "electricity": 6.61,
      "site_grid": 3.09,
      "operations": 15.51,
      "total": 71.48,
      "electricity_usd_2026_kwh": 0.2051,
      "wacc": 0.0538,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.41,
      "electricity": 12.16,
      "site_grid": 6.77,
      "operations": 18.44,
      "total": 118.77,
      "electricity_usd_2026_kwh": 0.2051,
      "wacc": 0.0538,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.38,
      "electricity": 15.56,
      "site_grid": 6.84,
      "operations": 36.99,
      "total": 161.78,
      "electricity_usd_2026_kwh": 0.2051,
      "wacc": 0.0538,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.03,
      "electricity": 1.9,
      "site_grid": 1.37,
      "operations": 3.35,
      "total": 23.65,
      "electricity_usd_2026_kwh": 0.2049,
      "wacc": 0.0495,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.43,
      "electricity": 2.44,
      "site_grid": 1.39,
      "operations": 6.67,
      "total": 31.92,
      "electricity_usd_2026_kwh": 0.2049,
      "wacc": 0.0495,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.5,
      "electricity": 5.16,
      "site_grid": 2.93,
      "operations": 7.75,
      "total": 52.34,
      "electricity_usd_2026_kwh": 0.2049,
      "wacc": 0.0495,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.9,
      "electricity": 6.6,
      "site_grid": 2.98,
      "operations": 15.51,
      "total": 70.99,
      "electricity_usd_2026_kwh": 0.2049,
      "wacc": 0.0495,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.75,
      "electricity": 12.14,
      "site_grid": 6.48,
      "operations": 18.44,
      "total": 117.81,
      "electricity_usd_2026_kwh": 0.2049,
      "wacc": 0.0495,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.56,
      "electricity": 15.55,
      "site_grid": 6.58,
      "operations": 36.99,
      "total": 160.68,
      "electricity_usd_2026_kwh": 0.2049,
      "wacc": 0.0495,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.73,
      "electricity": 1.77,
      "site_grid": 1.28,
      "operations": 3.35,
      "total": 23.13,
      "electricity_usd_2026_kwh": 0.1908,
      "wacc": 0.0397,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.03,
      "electricity": 2.27,
      "site_grid": 1.32,
      "operations": 6.67,
      "total": 31.29,
      "electricity_usd_2026_kwh": 0.1908,
      "wacc": 0.0397,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.84,
      "electricity": 4.8,
      "site_grid": 2.75,
      "operations": 7.75,
      "total": 51.15,
      "electricity_usd_2026_kwh": 0.1908,
      "wacc": 0.0397,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.06,
      "electricity": 6.15,
      "site_grid": 2.83,
      "operations": 15.51,
      "total": 69.55,
      "electricity_usd_2026_kwh": 0.1908,
      "wacc": 0.0397,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.3,
      "electricity": 11.31,
      "site_grid": 6.09,
      "operations": 18.44,
      "total": 115.14,
      "electricity_usd_2026_kwh": 0.1908,
      "wacc": 0.0397,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.7,
      "electricity": 14.48,
      "site_grid": 6.26,
      "operations": 36.99,
      "total": 157.43,
      "electricity_usd_2026_kwh": 0.1908,
      "wacc": 0.0397,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.9,
      "electricity": 1.74,
      "site_grid": 1.34,
      "operations": 3.35,
      "total": 23.32,
      "electricity_usd_2026_kwh": 0.1869,
      "wacc": 0.0452,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.25,
      "electricity": 2.22,
      "site_grid": 1.37,
      "operations": 6.67,
      "total": 31.52,
      "electricity_usd_2026_kwh": 0.1869,
      "wacc": 0.0452,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.2,
      "electricity": 4.7,
      "site_grid": 2.88,
      "operations": 7.75,
      "total": 51.54,
      "electricity_usd_2026_kwh": 0.1869,
      "wacc": 0.0452,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.53,
      "electricity": 6.02,
      "site_grid": 2.94,
      "operations": 15.51,
      "total": 70.01,
      "electricity_usd_2026_kwh": 0.1869,
      "wacc": 0.0452,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.09,
      "electricity": 11.08,
      "site_grid": 6.37,
      "operations": 18.44,
      "total": 115.98,
      "electricity_usd_2026_kwh": 0.1869,
      "wacc": 0.0452,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.74,
      "electricity": 14.18,
      "site_grid": 6.51,
      "operations": 36.99,
      "total": 158.43,
      "electricity_usd_2026_kwh": 0.1869,
      "wacc": 0.0452,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.96,
      "electricity": 1.72,
      "site_grid": 1.38,
      "operations": 3.35,
      "total": 23.41,
      "electricity_usd_2026_kwh": 0.185,
      "wacc": 0.0471,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.33,
      "electricity": 2.2,
      "site_grid": 1.41,
      "operations": 6.67,
      "total": 31.61,
      "electricity_usd_2026_kwh": 0.185,
      "wacc": 0.0471,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.33,
      "electricity": 4.66,
      "site_grid": 2.96,
      "operations": 7.75,
      "total": 51.71,
      "electricity_usd_2026_kwh": 0.185,
      "wacc": 0.0471,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.7,
      "electricity": 5.96,
      "site_grid": 3.02,
      "operations": 15.51,
      "total": 70.19,
      "electricity_usd_2026_kwh": 0.185,
      "wacc": 0.0471,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.38,
      "electricity": 10.97,
      "site_grid": 6.56,
      "operations": 18.44,
      "total": 116.35,
      "electricity_usd_2026_kwh": 0.185,
      "wacc": 0.0471,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.1,
      "electricity": 14.04,
      "site_grid": 6.69,
      "operations": 36.99,
      "total": 158.82,
      "electricity_usd_2026_kwh": 0.185,
      "wacc": 0.0471,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.83,
      "electricity": 1.31,
      "site_grid": 1.37,
      "operations": 3.35,
      "total": 22.85,
      "electricity_usd_2026_kwh": 0.141,
      "wacc": 0.0431,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.17,
      "electricity": 1.68,
      "site_grid": 1.4,
      "operations": 6.67,
      "total": 30.92,
      "electricity_usd_2026_kwh": 0.141,
      "wacc": 0.0431,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.05,
      "electricity": 3.55,
      "site_grid": 2.93,
      "operations": 7.75,
      "total": 50.29,
      "electricity_usd_2026_kwh": 0.141,
      "wacc": 0.0431,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.35,
      "electricity": 4.54,
      "site_grid": 3.01,
      "operations": 15.51,
      "total": 68.41,
      "electricity_usd_2026_kwh": 0.141,
      "wacc": 0.0431,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.77,
      "electricity": 8.35,
      "site_grid": 6.49,
      "operations": 18.44,
      "total": 113.05,
      "electricity_usd_2026_kwh": 0.141,
      "wacc": 0.0431,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.33,
      "electricity": 10.7,
      "site_grid": 6.65,
      "operations": 36.99,
      "total": 154.68,
      "electricity_usd_2026_kwh": 0.141,
      "wacc": 0.0431,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.73,
      "electricity": 1.23,
      "site_grid": 1.33,
      "operations": 3.35,
      "total": 22.64,
      "electricity_usd_2026_kwh": 0.132,
      "wacc": 0.0401,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.05,
      "electricity": 1.57,
      "site_grid": 1.37,
      "operations": 6.67,
      "total": 30.66,
      "electricity_usd_2026_kwh": 0.132,
      "wacc": 0.0401,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.85,
      "electricity": 3.32,
      "site_grid": 2.85,
      "operations": 7.75,
      "total": 49.78,
      "electricity_usd_2026_kwh": 0.132,
      "wacc": 0.0401,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.09,
      "electricity": 4.25,
      "site_grid": 2.94,
      "operations": 15.51,
      "total": 67.79,
      "electricity_usd_2026_kwh": 0.132,
      "wacc": 0.0401,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.31,
      "electricity": 7.82,
      "site_grid": 6.31,
      "operations": 18.44,
      "total": 111.89,
      "electricity_usd_2026_kwh": 0.132,
      "wacc": 0.0401,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.76,
      "electricity": 10.01,
      "site_grid": 6.5,
      "operations": 36.99,
      "total": 153.27,
      "electricity_usd_2026_kwh": 0.132,
      "wacc": 0.0401,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.89,
      "electricity": 1.12,
      "site_grid": 1.38,
      "operations": 3.35,
      "total": 22.74,
      "electricity_usd_2026_kwh": 0.1206,
      "wacc": 0.045,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.24,
      "electricity": 1.43,
      "site_grid": 1.42,
      "operations": 6.67,
      "total": 30.76,
      "electricity_usd_2026_kwh": 0.1206,
      "wacc": 0.045,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.19,
      "electricity": 3.04,
      "site_grid": 2.97,
      "operations": 7.75,
      "total": 49.94,
      "electricity_usd_2026_kwh": 0.1206,
      "wacc": 0.045,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.52,
      "electricity": 3.89,
      "site_grid": 3.03,
      "operations": 15.51,
      "total": 67.94,
      "electricity_usd_2026_kwh": 0.1206,
      "wacc": 0.045,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.06,
      "electricity": 7.15,
      "site_grid": 6.56,
      "operations": 18.44,
      "total": 112.21,
      "electricity_usd_2026_kwh": 0.1206,
      "wacc": 0.045,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.7,
      "electricity": 9.15,
      "site_grid": 6.71,
      "operations": 36.99,
      "total": 153.55,
      "electricity_usd_2026_kwh": 0.1206,
      "wacc": 0.045,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.08,
      "electricity": 1.21,
      "site_grid": 1.47,
      "operations": 3.35,
      "total": 23.11,
      "electricity_usd_2026_kwh": 0.1305,
      "wacc": 0.0508,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.48,
      "electricity": 1.55,
      "site_grid": 1.5,
      "operations": 6.67,
      "total": 31.2,
      "electricity_usd_2026_kwh": 0.1305,
      "wacc": 0.0508,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.59,
      "electricity": 3.28,
      "site_grid": 3.16,
      "operations": 7.75,
      "total": 50.78,
      "electricity_usd_2026_kwh": 0.1305,
      "wacc": 0.0508,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.02,
      "electricity": 4.21,
      "site_grid": 3.2,
      "operations": 15.51,
      "total": 68.93,
      "electricity_usd_2026_kwh": 0.1305,
      "wacc": 0.0508,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.94,
      "electricity": 7.74,
      "site_grid": 6.99,
      "operations": 18.44,
      "total": 114.11,
      "electricity_usd_2026_kwh": 0.1305,
      "wacc": 0.0508,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.8,
      "electricity": 9.9,
      "site_grid": 7.09,
      "operations": 36.99,
      "total": 155.79,
      "electricity_usd_2026_kwh": 0.1305,
      "wacc": 0.0508,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.83,
      "electricity": 1.21,
      "site_grid": 1.45,
      "operations": 3.35,
      "total": 22.84,
      "electricity_usd_2026_kwh": 0.1304,
      "wacc": 0.0431,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.17,
      "electricity": 1.55,
      "site_grid": 1.49,
      "operations": 6.67,
      "total": 30.88,
      "electricity_usd_2026_kwh": 0.1304,
      "wacc": 0.0431,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.06,
      "electricity": 3.28,
      "site_grid": 3.11,
      "operations": 7.75,
      "total": 50.21,
      "electricity_usd_2026_kwh": 0.1304,
      "wacc": 0.0431,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.35,
      "electricity": 4.2,
      "site_grid": 3.19,
      "operations": 15.51,
      "total": 68.25,
      "electricity_usd_2026_kwh": 0.1304,
      "wacc": 0.0431,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.77,
      "electricity": 7.73,
      "site_grid": 6.89,
      "operations": 18.44,
      "total": 112.83,
      "electricity_usd_2026_kwh": 0.1304,
      "wacc": 0.0431,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.34,
      "electricity": 9.9,
      "site_grid": 7.06,
      "operations": 36.99,
      "total": 154.29,
      "electricity_usd_2026_kwh": 0.1304,
      "wacc": 0.0431,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.73,
      "electricity": 1.26,
      "site_grid": 1.45,
      "operations": 3.35,
      "total": 22.79,
      "electricity_usd_2026_kwh": 0.1361,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.85,
      "electricity": 1.62,
      "site_grid": 1.45,
      "operations": 6.67,
      "total": 30.58,
      "electricity_usd_2026_kwh": 0.1361,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.84,
      "electricity": 3.42,
      "site_grid": 3.1,
      "operations": 7.75,
      "total": 50.12,
      "electricity_usd_2026_kwh": 0.1361,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.66,
      "electricity": 4.38,
      "site_grid": 3.1,
      "operations": 15.51,
      "total": 67.65,
      "electricity_usd_2026_kwh": 0.1361,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.3,
      "electricity": 8.06,
      "site_grid": 6.85,
      "operations": 18.44,
      "total": 112.66,
      "electricity_usd_2026_kwh": 0.1361,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.81,
      "electricity": 10.32,
      "site_grid": 6.85,
      "operations": 36.99,
      "total": 152.98,
      "electricity_usd_2026_kwh": 0.1361,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.73,
      "electricity": 1.29,
      "site_grid": 1.45,
      "operations": 3.35,
      "total": 22.82,
      "electricity_usd_2026_kwh": 0.1391,
      "wacc": 0.0362,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.89,
      "electricity": 1.65,
      "site_grid": 1.46,
      "operations": 6.67,
      "total": 30.68,
      "electricity_usd_2026_kwh": 0.1391,
      "wacc": 0.0362,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.84,
      "electricity": 3.5,
      "site_grid": 3.11,
      "operations": 7.75,
      "total": 50.21,
      "electricity_usd_2026_kwh": 0.1391,
      "wacc": 0.0362,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.76,
      "electricity": 4.48,
      "site_grid": 3.13,
      "operations": 15.51,
      "total": 67.88,
      "electricity_usd_2026_kwh": 0.1391,
      "wacc": 0.0362,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.3,
      "electricity": 8.25,
      "site_grid": 6.89,
      "operations": 18.44,
      "total": 112.88,
      "electricity_usd_2026_kwh": 0.1391,
      "wacc": 0.0362,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.03,
      "electricity": 10.56,
      "site_grid": 6.93,
      "operations": 36.99,
      "total": 153.51,
      "electricity_usd_2026_kwh": 0.1391,
      "wacc": 0.0362,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.09,
      "electricity": 1.55,
      "site_grid": 1.78,
      "operations": 3.35,
      "total": 23.77,
      "electricity_usd_2026_kwh": 0.1669,
      "wacc": 0.0512,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.49,
      "electricity": 1.98,
      "site_grid": 1.81,
      "operations": 6.67,
      "total": 31.95,
      "electricity_usd_2026_kwh": 0.1669,
      "wacc": 0.0512,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.61,
      "electricity": 4.2,
      "site_grid": 3.82,
      "operations": 7.75,
      "total": 52.38,
      "electricity_usd_2026_kwh": 0.1669,
      "wacc": 0.0512,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.05,
      "electricity": 5.38,
      "site_grid": 3.87,
      "operations": 15.51,
      "total": 70.8,
      "electricity_usd_2026_kwh": 0.1669,
      "wacc": 0.0512,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.0,
      "electricity": 9.89,
      "site_grid": 8.44,
      "operations": 18.44,
      "total": 117.78,
      "electricity_usd_2026_kwh": 0.1669,
      "wacc": 0.0512,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.88,
      "electricity": 12.66,
      "site_grid": 8.56,
      "operations": 36.99,
      "total": 160.1,
      "electricity_usd_2026_kwh": 0.1669,
      "wacc": 0.0512,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.41,
      "electricity": 2.63,
      "site_grid": 1.97,
      "operations": 3.35,
      "total": 25.36,
      "electricity_usd_2026_kwh": 0.2833,
      "wacc": 0.0613,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.9,
      "electricity": 3.37,
      "site_grid": 1.97,
      "operations": 6.67,
      "total": 33.91,
      "electricity_usd_2026_kwh": 0.2833,
      "wacc": 0.0613,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.31,
      "electricity": 7.13,
      "site_grid": 4.22,
      "operations": 7.75,
      "total": 56.42,
      "electricity_usd_2026_kwh": 0.2833,
      "wacc": 0.0613,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.92,
      "electricity": 9.13,
      "site_grid": 4.23,
      "operations": 15.51,
      "total": 75.78,
      "electricity_usd_2026_kwh": 0.2833,
      "wacc": 0.0613,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.54,
      "electricity": 16.79,
      "site_grid": 9.34,
      "operations": 18.44,
      "total": 127.12,
      "electricity_usd_2026_kwh": 0.2833,
      "wacc": 0.0613,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.81,
      "electricity": 21.5,
      "site_grid": 9.35,
      "operations": 36.99,
      "total": 171.65,
      "electricity_usd_2026_kwh": 0.2833,
      "wacc": 0.0613,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.5,
      "electricity": 2.16,
      "site_grid": 1.94,
      "operations": 3.35,
      "total": 24.95,
      "electricity_usd_2026_kwh": 0.233,
      "wacc": 0.0638,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.0,
      "electricity": 2.77,
      "site_grid": 1.94,
      "operations": 6.67,
      "total": 33.38,
      "electricity_usd_2026_kwh": 0.233,
      "wacc": 0.0638,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.48,
      "electricity": 5.87,
      "site_grid": 4.16,
      "operations": 7.75,
      "total": 55.26,
      "electricity_usd_2026_kwh": 0.233,
      "wacc": 0.0638,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.14,
      "electricity": 7.51,
      "site_grid": 4.15,
      "operations": 15.51,
      "total": 74.3,
      "electricity_usd_2026_kwh": 0.233,
      "wacc": 0.0638,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.93,
      "electricity": 13.81,
      "site_grid": 9.2,
      "operations": 18.44,
      "total": 124.38,
      "electricity_usd_2026_kwh": 0.233,
      "wacc": 0.0638,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.28,
      "electricity": 17.68,
      "site_grid": 9.17,
      "operations": 36.99,
      "total": 168.14,
      "electricity_usd_2026_kwh": 0.233,
      "wacc": 0.0638,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.52,
      "electricity": 1.88,
      "site_grid": 1.93,
      "operations": 3.35,
      "total": 24.68,
      "electricity_usd_2026_kwh": 0.2026,
      "wacc": 0.0646,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.04,
      "electricity": 2.41,
      "site_grid": 1.92,
      "operations": 6.67,
      "total": 33.03,
      "electricity_usd_2026_kwh": 0.2026,
      "wacc": 0.0646,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.54,
      "electricity": 5.1,
      "site_grid": 4.13,
      "operations": 7.75,
      "total": 54.52,
      "electricity_usd_2026_kwh": 0.2026,
      "wacc": 0.0646,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.21,
      "electricity": 6.53,
      "site_grid": 4.11,
      "operations": 15.51,
      "total": 73.36,
      "electricity_usd_2026_kwh": 0.2026,
      "wacc": 0.0646,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.06,
      "electricity": 12.01,
      "site_grid": 9.13,
      "operations": 18.44,
      "total": 122.64,
      "electricity_usd_2026_kwh": 0.2026,
      "wacc": 0.0646,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.45,
      "electricity": 15.37,
      "site_grid": 9.1,
      "operations": 36.99,
      "total": 165.91,
      "electricity_usd_2026_kwh": 0.2026,
      "wacc": 0.0646,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.53,
      "electricity": 1.83,
      "site_grid": 1.94,
      "operations": 3.35,
      "total": 24.65,
      "electricity_usd_2026_kwh": 0.1969,
      "wacc": 0.065,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.05,
      "electricity": 2.34,
      "site_grid": 1.93,
      "operations": 6.67,
      "total": 32.99,
      "electricity_usd_2026_kwh": 0.1969,
      "wacc": 0.065,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.57,
      "electricity": 4.96,
      "site_grid": 4.15,
      "operations": 7.75,
      "total": 54.43,
      "electricity_usd_2026_kwh": 0.1969,
      "wacc": 0.065,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.24,
      "electricity": 6.34,
      "site_grid": 4.13,
      "operations": 15.51,
      "total": 73.23,
      "electricity_usd_2026_kwh": 0.1969,
      "wacc": 0.065,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.12,
      "electricity": 11.67,
      "site_grid": 9.18,
      "operations": 18.44,
      "total": 122.41,
      "electricity_usd_2026_kwh": 0.1969,
      "wacc": 0.065,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.52,
      "electricity": 14.94,
      "site_grid": 9.14,
      "operations": 36.99,
      "total": 165.6,
      "electricity_usd_2026_kwh": 0.1969,
      "wacc": 0.065,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.44,
      "electricity": 3.67,
      "site_grid": 1.59,
      "operations": 3.49,
      "total": 28.19,
      "electricity_usd_2026_kwh": 0.3547,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.57,
      "electricity": 4.71,
      "site_grid": 1.58,
      "operations": 6.15,
      "total": 37.0,
      "electricity_usd_2026_kwh": 0.3547,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.66,
      "electricity": 9.94,
      "site_grid": 3.4,
      "operations": 8.07,
      "total": 63.07,
      "electricity_usd_2026_kwh": 0.3547,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.63,
      "electricity": 12.76,
      "site_grid": 3.38,
      "operations": 14.4,
      "total": 83.17,
      "electricity_usd_2026_kwh": 0.3547,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 92.16,
      "electricity": 23.42,
      "site_grid": 7.52,
      "operations": 19.15,
      "total": 142.25,
      "electricity_usd_2026_kwh": 0.3547,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 116.44,
      "electricity": 30.05,
      "site_grid": 7.47,
      "operations": 34.57,
      "total": 188.53,
      "electricity_usd_2026_kwh": 0.3547,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.29,
      "electricity": 3.79,
      "site_grid": 1.52,
      "operations": 3.49,
      "total": 28.09,
      "electricity_usd_2026_kwh": 0.3662,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.37,
      "electricity": 4.86,
      "site_grid": 1.52,
      "operations": 6.15,
      "total": 36.9,
      "electricity_usd_2026_kwh": 0.3662,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.33,
      "electricity": 10.26,
      "site_grid": 3.26,
      "operations": 8.07,
      "total": 62.92,
      "electricity_usd_2026_kwh": 0.3662,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.22,
      "electricity": 13.17,
      "site_grid": 3.26,
      "operations": 14.4,
      "total": 83.05,
      "electricity_usd_2026_kwh": 0.3662,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 91.43,
      "electricity": 24.17,
      "site_grid": 7.21,
      "operations": 19.15,
      "total": 141.97,
      "electricity_usd_2026_kwh": 0.3662,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 115.53,
      "electricity": 31.01,
      "site_grid": 7.21,
      "operations": 34.57,
      "total": 188.32,
      "electricity_usd_2026_kwh": 0.3662,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.94,
      "electricity": 3.44,
      "site_grid": 1.43,
      "operations": 3.49,
      "total": 27.31,
      "electricity_usd_2026_kwh": 0.333,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.94,
      "electricity": 4.42,
      "site_grid": 1.45,
      "operations": 6.15,
      "total": 35.96,
      "electricity_usd_2026_kwh": 0.333,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.58,
      "electricity": 9.33,
      "site_grid": 3.07,
      "operations": 8.07,
      "total": 61.06,
      "electricity_usd_2026_kwh": 0.333,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.29,
      "electricity": 11.98,
      "site_grid": 3.11,
      "operations": 14.4,
      "total": 80.77,
      "electricity_usd_2026_kwh": 0.333,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.79,
      "electricity": 21.98,
      "site_grid": 6.79,
      "operations": 19.15,
      "total": 137.71,
      "electricity_usd_2026_kwh": 0.333,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 113.46,
      "electricity": 28.2,
      "site_grid": 6.87,
      "operations": 34.57,
      "total": 183.11,
      "electricity_usd_2026_kwh": 0.333,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.14,
      "electricity": 3.48,
      "site_grid": 1.5,
      "operations": 3.49,
      "total": 27.61,
      "electricity_usd_2026_kwh": 0.3364,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.18,
      "electricity": 4.46,
      "site_grid": 1.51,
      "operations": 6.15,
      "total": 36.3,
      "electricity_usd_2026_kwh": 0.3364,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.0,
      "electricity": 9.43,
      "site_grid": 3.21,
      "operations": 8.07,
      "total": 61.71,
      "electricity_usd_2026_kwh": 0.3364,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.81,
      "electricity": 12.1,
      "site_grid": 3.23,
      "operations": 14.4,
      "total": 81.53,
      "electricity_usd_2026_kwh": 0.3364,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.7,
      "electricity": 22.2,
      "site_grid": 7.11,
      "operations": 19.15,
      "total": 139.16,
      "electricity_usd_2026_kwh": 0.3364,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 114.61,
      "electricity": 28.49,
      "site_grid": 7.14,
      "operations": 34.57,
      "total": 184.81,
      "electricity_usd_2026_kwh": 0.3364,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.2,
      "electricity": 3.41,
      "site_grid": 1.54,
      "operations": 3.49,
      "total": 27.65,
      "electricity_usd_2026_kwh": 0.3294,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.26,
      "electricity": 4.37,
      "site_grid": 1.55,
      "operations": 6.15,
      "total": 36.33,
      "electricity_usd_2026_kwh": 0.3294,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.14,
      "electricity": 9.23,
      "site_grid": 3.3,
      "operations": 8.07,
      "total": 61.75,
      "electricity_usd_2026_kwh": 0.3294,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.99,
      "electricity": 11.85,
      "site_grid": 3.31,
      "operations": 14.4,
      "total": 81.55,
      "electricity_usd_2026_kwh": 0.3294,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 91.02,
      "electricity": 21.74,
      "site_grid": 7.31,
      "operations": 19.15,
      "total": 139.23,
      "electricity_usd_2026_kwh": 0.3294,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 115.02,
      "electricity": 27.9,
      "site_grid": 7.33,
      "operations": 34.57,
      "total": 184.81,
      "electricity_usd_2026_kwh": 0.3294,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.06,
      "electricity": 2.4,
      "site_grid": 1.53,
      "operations": 3.49,
      "total": 26.49,
      "electricity_usd_2026_kwh": 0.2325,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.09,
      "electricity": 3.08,
      "site_grid": 1.54,
      "operations": 6.15,
      "total": 34.86,
      "electricity_usd_2026_kwh": 0.2325,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.84,
      "electricity": 6.52,
      "site_grid": 3.28,
      "operations": 8.07,
      "total": 58.7,
      "electricity_usd_2026_kwh": 0.2325,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.6,
      "electricity": 8.36,
      "site_grid": 3.3,
      "operations": 14.4,
      "total": 77.67,
      "electricity_usd_2026_kwh": 0.2325,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.35,
      "electricity": 15.35,
      "site_grid": 7.25,
      "operations": 19.15,
      "total": 132.09,
      "electricity_usd_2026_kwh": 0.2325,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 114.17,
      "electricity": 19.69,
      "site_grid": 7.3,
      "operations": 34.57,
      "total": 175.73,
      "electricity_usd_2026_kwh": 0.2325,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.95,
      "electricity": 2.22,
      "site_grid": 1.49,
      "operations": 3.49,
      "total": 26.16,
      "electricity_usd_2026_kwh": 0.215,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.95,
      "electricity": 2.85,
      "site_grid": 1.5,
      "operations": 6.15,
      "total": 34.46,
      "electricity_usd_2026_kwh": 0.215,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.61,
      "electricity": 6.03,
      "site_grid": 3.19,
      "operations": 8.07,
      "total": 57.9,
      "electricity_usd_2026_kwh": 0.215,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.32,
      "electricity": 7.73,
      "site_grid": 3.22,
      "operations": 14.4,
      "total": 76.68,
      "electricity_usd_2026_kwh": 0.215,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.84,
      "electricity": 14.19,
      "site_grid": 7.06,
      "operations": 19.15,
      "total": 130.25,
      "electricity_usd_2026_kwh": 0.215,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 113.54,
      "electricity": 18.21,
      "site_grid": 7.13,
      "operations": 34.57,
      "total": 173.45,
      "electricity_usd_2026_kwh": 0.215,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.13,
      "electricity": 2.14,
      "site_grid": 1.54,
      "operations": 3.49,
      "total": 26.31,
      "electricity_usd_2026_kwh": 0.2069,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.17,
      "electricity": 2.74,
      "site_grid": 1.55,
      "operations": 6.15,
      "total": 34.62,
      "electricity_usd_2026_kwh": 0.2069,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.98,
      "electricity": 5.8,
      "site_grid": 3.31,
      "operations": 8.07,
      "total": 58.16,
      "electricity_usd_2026_kwh": 0.2069,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.79,
      "electricity": 7.44,
      "site_grid": 3.32,
      "operations": 14.4,
      "total": 76.95,
      "electricity_usd_2026_kwh": 0.2069,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.67,
      "electricity": 13.65,
      "site_grid": 7.32,
      "operations": 19.15,
      "total": 130.79,
      "electricity_usd_2026_kwh": 0.2069,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 114.57,
      "electricity": 17.52,
      "site_grid": 7.35,
      "operations": 34.57,
      "total": 174.02,
      "electricity_usd_2026_kwh": 0.2069,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.33,
      "electricity": 2.17,
      "site_grid": 1.64,
      "operations": 3.49,
      "total": 26.64,
      "electricity_usd_2026_kwh": 0.2097,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.43,
      "electricity": 2.78,
      "site_grid": 1.64,
      "operations": 6.15,
      "total": 35.0,
      "electricity_usd_2026_kwh": 0.2097,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.42,
      "electricity": 5.88,
      "site_grid": 3.52,
      "operations": 8.07,
      "total": 58.89,
      "electricity_usd_2026_kwh": 0.2097,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.34,
      "electricity": 7.54,
      "site_grid": 3.51,
      "operations": 14.4,
      "total": 77.79,
      "electricity_usd_2026_kwh": 0.2097,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 91.64,
      "electricity": 13.84,
      "site_grid": 7.78,
      "operations": 19.15,
      "total": 132.42,
      "electricity_usd_2026_kwh": 0.2097,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 115.8,
      "electricity": 17.76,
      "site_grid": 7.76,
      "operations": 34.57,
      "total": 175.89,
      "electricity_usd_2026_kwh": 0.2097,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.06,
      "electricity": 2.02,
      "site_grid": 1.62,
      "operations": 3.49,
      "total": 26.2,
      "electricity_usd_2026_kwh": 0.1955,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.09,
      "electricity": 2.59,
      "site_grid": 1.63,
      "operations": 6.15,
      "total": 34.47,
      "electricity_usd_2026_kwh": 0.1955,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.84,
      "electricity": 5.48,
      "site_grid": 3.48,
      "operations": 8.07,
      "total": 57.87,
      "electricity_usd_2026_kwh": 0.1955,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.61,
      "electricity": 7.03,
      "site_grid": 3.5,
      "operations": 14.4,
      "total": 76.54,
      "electricity_usd_2026_kwh": 0.1955,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.35,
      "electricity": 12.9,
      "site_grid": 7.69,
      "operations": 19.15,
      "total": 130.1,
      "electricity_usd_2026_kwh": 0.1955,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 114.17,
      "electricity": 16.56,
      "site_grid": 7.74,
      "operations": 34.57,
      "total": 173.05,
      "electricity_usd_2026_kwh": 0.1955,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.62,
      "electricity": 2.02,
      "site_grid": 1.51,
      "operations": 3.49,
      "total": 25.65,
      "electricity_usd_2026_kwh": 0.1958,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.53,
      "electricity": 2.6,
      "site_grid": 1.55,
      "operations": 6.15,
      "total": 33.83,
      "electricity_usd_2026_kwh": 0.1958,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.89,
      "electricity": 5.49,
      "site_grid": 3.24,
      "operations": 8.07,
      "total": 56.7,
      "electricity_usd_2026_kwh": 0.1958,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.42,
      "electricity": 7.04,
      "site_grid": 3.32,
      "operations": 14.4,
      "total": 75.19,
      "electricity_usd_2026_kwh": 0.1958,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.26,
      "electricity": 12.92,
      "site_grid": 7.18,
      "operations": 19.15,
      "total": 127.52,
      "electricity_usd_2026_kwh": 0.1958,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.55,
      "electricity": 16.58,
      "site_grid": 7.35,
      "operations": 34.57,
      "total": 170.05,
      "electricity_usd_2026_kwh": 0.1958,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.82,
      "electricity": 2.05,
      "site_grid": 1.58,
      "operations": 3.49,
      "total": 25.94,
      "electricity_usd_2026_kwh": 0.1981,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.78,
      "electricity": 2.63,
      "site_grid": 1.61,
      "operations": 6.15,
      "total": 34.17,
      "electricity_usd_2026_kwh": 0.1981,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.31,
      "electricity": 5.55,
      "site_grid": 3.39,
      "operations": 8.07,
      "total": 57.33,
      "electricity_usd_2026_kwh": 0.1981,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.95,
      "electricity": 7.13,
      "site_grid": 3.44,
      "operations": 14.4,
      "total": 75.92,
      "electricity_usd_2026_kwh": 0.1981,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.19,
      "electricity": 13.08,
      "site_grid": 7.5,
      "operations": 19.15,
      "total": 128.92,
      "electricity_usd_2026_kwh": 0.1981,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.72,
      "electricity": 16.78,
      "site_grid": 7.62,
      "operations": 34.57,
      "total": 171.69,
      "electricity_usd_2026_kwh": 0.1981,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.35,
      "electricity": 1.66,
      "site_grid": 1.98,
      "operations": 3.49,
      "total": 26.48,
      "electricity_usd_2026_kwh": 0.1603,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.45,
      "electricity": 2.13,
      "site_grid": 1.98,
      "operations": 6.15,
      "total": 34.7,
      "electricity_usd_2026_kwh": 0.1603,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.45,
      "electricity": 4.49,
      "site_grid": 4.24,
      "operations": 8.07,
      "total": 58.26,
      "electricity_usd_2026_kwh": 0.1603,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.38,
      "electricity": 5.76,
      "site_grid": 4.23,
      "operations": 14.4,
      "total": 76.78,
      "electricity_usd_2026_kwh": 0.1603,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 91.71,
      "electricity": 10.58,
      "site_grid": 9.39,
      "operations": 19.15,
      "total": 130.84,
      "electricity_usd_2026_kwh": 0.1603,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 115.88,
      "electricity": 13.57,
      "site_grid": 9.36,
      "operations": 34.57,
      "total": 173.39,
      "electricity_usd_2026_kwh": 0.1603,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.71,
      "electricity": 1.71,
      "site_grid": 2.18,
      "operations": 3.49,
      "total": 27.1,
      "electricity_usd_2026_kwh": 0.1656,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.9,
      "electricity": 2.2,
      "site_grid": 2.15,
      "operations": 6.15,
      "total": 35.4,
      "electricity_usd_2026_kwh": 0.1656,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.22,
      "electricity": 4.64,
      "site_grid": 4.68,
      "operations": 8.07,
      "total": 59.62,
      "electricity_usd_2026_kwh": 0.1656,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.35,
      "electricity": 5.96,
      "site_grid": 4.61,
      "operations": 14.4,
      "total": 78.31,
      "electricity_usd_2026_kwh": 0.1656,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 93.41,
      "electricity": 10.93,
      "site_grid": 10.35,
      "operations": 19.15,
      "total": 133.85,
      "electricity_usd_2026_kwh": 0.1656,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 118.02,
      "electricity": 14.03,
      "site_grid": 10.2,
      "operations": 34.57,
      "total": 176.82,
      "electricity_usd_2026_kwh": 0.1656,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.8,
      "electricity": 1.62,
      "site_grid": 2.15,
      "operations": 3.49,
      "total": 27.06,
      "electricity_usd_2026_kwh": 0.1571,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.01,
      "electricity": 2.08,
      "site_grid": 2.11,
      "operations": 6.15,
      "total": 35.35,
      "electricity_usd_2026_kwh": 0.1571,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.41,
      "electricity": 4.4,
      "site_grid": 4.6,
      "operations": 8.07,
      "total": 59.49,
      "electricity_usd_2026_kwh": 0.1571,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.59,
      "electricity": 5.65,
      "site_grid": 4.52,
      "operations": 14.4,
      "total": 78.16,
      "electricity_usd_2026_kwh": 0.1571,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 93.84,
      "electricity": 10.37,
      "site_grid": 10.18,
      "operations": 19.15,
      "total": 133.53,
      "electricity_usd_2026_kwh": 0.1571,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 118.55,
      "electricity": 13.3,
      "site_grid": 10.0,
      "operations": 34.57,
      "total": 176.42,
      "electricity_usd_2026_kwh": 0.1571,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.83,
      "electricity": 1.62,
      "site_grid": 2.13,
      "operations": 3.49,
      "total": 27.07,
      "electricity_usd_2026_kwh": 0.1568,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.05,
      "electricity": 2.08,
      "site_grid": 2.09,
      "operations": 6.15,
      "total": 35.37,
      "electricity_usd_2026_kwh": 0.1568,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.48,
      "electricity": 4.39,
      "site_grid": 4.56,
      "operations": 8.07,
      "total": 59.51,
      "electricity_usd_2026_kwh": 0.1568,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.67,
      "electricity": 5.64,
      "site_grid": 4.48,
      "operations": 14.4,
      "total": 78.19,
      "electricity_usd_2026_kwh": 0.1568,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 93.98,
      "electricity": 10.35,
      "site_grid": 10.1,
      "operations": 19.15,
      "total": 133.58,
      "electricity_usd_2026_kwh": 0.1568,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 118.73,
      "electricity": 13.28,
      "site_grid": 9.91,
      "operations": 34.57,
      "total": 176.5,
      "electricity_usd_2026_kwh": 0.1568,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.84,
      "electricity": 1.6,
      "site_grid": 2.14,
      "operations": 3.49,
      "total": 27.08,
      "electricity_usd_2026_kwh": 0.155,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.07,
      "electricity": 2.06,
      "site_grid": 2.1,
      "operations": 6.15,
      "total": 35.37,
      "electricity_usd_2026_kwh": 0.155,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.51,
      "electricity": 4.35,
      "site_grid": 4.59,
      "operations": 8.07,
      "total": 59.51,
      "electricity_usd_2026_kwh": 0.155,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.7,
      "electricity": 5.58,
      "site_grid": 4.5,
      "operations": 14.4,
      "total": 78.18,
      "electricity_usd_2026_kwh": 0.155,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.04,
      "electricity": 10.23,
      "site_grid": 10.15,
      "operations": 19.15,
      "total": 133.58,
      "electricity_usd_2026_kwh": 0.155,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 118.81,
      "electricity": 13.13,
      "site_grid": 9.96,
      "operations": 34.57,
      "total": 176.47,
      "electricity_usd_2026_kwh": 0.155,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.07,
      "electricity": 1.83,
      "site_grid": 1.5,
      "operations": 3.29,
      "total": 23.69,
      "electricity_usd_2026_kwh": 0.1992,
      "wacc": 0.0558,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.47,
      "electricity": 2.35,
      "site_grid": 1.73,
      "operations": 6.47,
      "total": 32.02,
      "electricity_usd_2026_kwh": 0.1992,
      "wacc": 0.0558,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.58,
      "electricity": 4.97,
      "site_grid": 3.22,
      "operations": 7.63,
      "total": 52.39,
      "electricity_usd_2026_kwh": 0.1992,
      "wacc": 0.0558,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.0,
      "electricity": 6.36,
      "site_grid": 3.72,
      "operations": 15.08,
      "total": 71.15,
      "electricity_usd_2026_kwh": 0.1992,
      "wacc": 0.0558,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.92,
      "electricity": 11.7,
      "site_grid": 7.12,
      "operations": 18.16,
      "total": 117.9,
      "electricity_usd_2026_kwh": 0.1992,
      "wacc": 0.0558,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.77,
      "electricity": 14.98,
      "site_grid": 8.22,
      "operations": 36.04,
      "total": 161.01,
      "electricity_usd_2026_kwh": 0.1992,
      "wacc": 0.0558,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.93,
      "electricity": 1.82,
      "site_grid": 1.44,
      "operations": 3.29,
      "total": 23.48,
      "electricity_usd_2026_kwh": 0.1981,
      "wacc": 0.0515,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.3,
      "electricity": 2.33,
      "site_grid": 1.67,
      "operations": 6.47,
      "total": 31.77,
      "electricity_usd_2026_kwh": 0.1981,
      "wacc": 0.0515,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.28,
      "electricity": 4.94,
      "site_grid": 3.08,
      "operations": 7.63,
      "total": 51.93,
      "electricity_usd_2026_kwh": 0.1981,
      "wacc": 0.0515,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.63,
      "electricity": 6.33,
      "site_grid": 3.58,
      "operations": 15.08,
      "total": 70.61,
      "electricity_usd_2026_kwh": 0.1981,
      "wacc": 0.0515,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.26,
      "electricity": 11.64,
      "site_grid": 6.82,
      "operations": 18.16,
      "total": 116.88,
      "electricity_usd_2026_kwh": 0.1981,
      "wacc": 0.0515,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.95,
      "electricity": 14.9,
      "site_grid": 7.92,
      "operations": 36.04,
      "total": 159.81,
      "electricity_usd_2026_kwh": 0.1981,
      "wacc": 0.0515,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.62,
      "electricity": 1.65,
      "site_grid": 1.35,
      "operations": 3.29,
      "total": 22.9,
      "electricity_usd_2026_kwh": 0.1789,
      "wacc": 0.0417,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.91,
      "electricity": 2.11,
      "site_grid": 1.59,
      "operations": 6.47,
      "total": 31.07,
      "electricity_usd_2026_kwh": 0.1789,
      "wacc": 0.0417,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.61,
      "electricity": 4.46,
      "site_grid": 2.89,
      "operations": 7.63,
      "total": 50.59,
      "electricity_usd_2026_kwh": 0.1789,
      "wacc": 0.0417,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.8,
      "electricity": 5.71,
      "site_grid": 3.4,
      "operations": 15.08,
      "total": 68.99,
      "electricity_usd_2026_kwh": 0.1789,
      "wacc": 0.0417,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.79,
      "electricity": 10.51,
      "site_grid": 6.39,
      "operations": 18.16,
      "total": 113.85,
      "electricity_usd_2026_kwh": 0.1789,
      "wacc": 0.0417,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.11,
      "electricity": 13.45,
      "site_grid": 7.53,
      "operations": 36.04,
      "total": 156.13,
      "electricity_usd_2026_kwh": 0.1789,
      "wacc": 0.0417,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.8,
      "electricity": 1.64,
      "site_grid": 1.41,
      "operations": 3.29,
      "total": 23.14,
      "electricity_usd_2026_kwh": 0.1781,
      "wacc": 0.0472,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.13,
      "electricity": 2.1,
      "site_grid": 1.65,
      "operations": 6.47,
      "total": 31.34,
      "electricity_usd_2026_kwh": 0.1781,
      "wacc": 0.0472,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.98,
      "electricity": 4.44,
      "site_grid": 3.03,
      "operations": 7.63,
      "total": 51.08,
      "electricity_usd_2026_kwh": 0.1781,
      "wacc": 0.0472,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.26,
      "electricity": 5.69,
      "site_grid": 3.54,
      "operations": 15.08,
      "total": 69.56,
      "electricity_usd_2026_kwh": 0.1781,
      "wacc": 0.0472,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.61,
      "electricity": 10.46,
      "site_grid": 6.71,
      "operations": 18.16,
      "total": 114.94,
      "electricity_usd_2026_kwh": 0.1781,
      "wacc": 0.0472,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.13,
      "electricity": 13.39,
      "site_grid": 7.83,
      "operations": 36.04,
      "total": 157.4,
      "electricity_usd_2026_kwh": 0.1781,
      "wacc": 0.0472,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.86,
      "electricity": 1.56,
      "site_grid": 1.46,
      "operations": 3.29,
      "total": 23.16,
      "electricity_usd_2026_kwh": 0.1691,
      "wacc": 0.0491,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.2,
      "electricity": 1.99,
      "site_grid": 1.7,
      "operations": 6.47,
      "total": 31.36,
      "electricity_usd_2026_kwh": 0.1691,
      "wacc": 0.0491,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.11,
      "electricity": 4.22,
      "site_grid": 3.12,
      "operations": 7.63,
      "total": 51.08,
      "electricity_usd_2026_kwh": 0.1691,
      "wacc": 0.0491,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.42,
      "electricity": 5.4,
      "site_grid": 3.64,
      "operations": 15.08,
      "total": 69.53,
      "electricity_usd_2026_kwh": 0.1691,
      "wacc": 0.0491,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.9,
      "electricity": 9.93,
      "site_grid": 6.9,
      "operations": 18.16,
      "total": 114.89,
      "electricity_usd_2026_kwh": 0.1691,
      "wacc": 0.0491,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.49,
      "electricity": 12.71,
      "site_grid": 8.04,
      "operations": 36.04,
      "total": 157.29,
      "electricity_usd_2026_kwh": 0.1691,
      "wacc": 0.0491,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.73,
      "electricity": 1.24,
      "site_grid": 1.44,
      "operations": 3.29,
      "total": 22.7,
      "electricity_usd_2026_kwh": 0.1353,
      "wacc": 0.0451,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.04,
      "electricity": 1.59,
      "site_grid": 1.69,
      "operations": 6.47,
      "total": 30.79,
      "electricity_usd_2026_kwh": 0.1353,
      "wacc": 0.0451,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.84,
      "electricity": 3.37,
      "site_grid": 3.09,
      "operations": 7.63,
      "total": 49.93,
      "electricity_usd_2026_kwh": 0.1353,
      "wacc": 0.0451,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.08,
      "electricity": 4.32,
      "site_grid": 3.62,
      "operations": 15.08,
      "total": 68.1,
      "electricity_usd_2026_kwh": 0.1353,
      "wacc": 0.0451,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.29,
      "electricity": 7.95,
      "site_grid": 6.83,
      "operations": 18.16,
      "total": 112.23,
      "electricity_usd_2026_kwh": 0.1353,
      "wacc": 0.0451,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.74,
      "electricity": 10.18,
      "site_grid": 8.0,
      "operations": 36.04,
      "total": 153.96,
      "electricity_usd_2026_kwh": 0.1353,
      "wacc": 0.0451,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.63,
      "electricity": 1.17,
      "site_grid": 1.4,
      "operations": 3.29,
      "total": 22.49,
      "electricity_usd_2026_kwh": 0.1267,
      "wacc": 0.0421,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.92,
      "electricity": 1.49,
      "site_grid": 1.65,
      "operations": 6.47,
      "total": 30.53,
      "electricity_usd_2026_kwh": 0.1267,
      "wacc": 0.0421,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.64,
      "electricity": 3.16,
      "site_grid": 3.0,
      "operations": 7.63,
      "total": 49.42,
      "electricity_usd_2026_kwh": 0.1267,
      "wacc": 0.0421,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.83,
      "electricity": 4.05,
      "site_grid": 3.53,
      "operations": 15.08,
      "total": 67.48,
      "electricity_usd_2026_kwh": 0.1267,
      "wacc": 0.0421,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.84,
      "electricity": 7.44,
      "site_grid": 6.64,
      "operations": 18.16,
      "total": 111.08,
      "electricity_usd_2026_kwh": 0.1267,
      "wacc": 0.0421,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.17,
      "electricity": 9.53,
      "site_grid": 7.82,
      "operations": 36.04,
      "total": 152.55,
      "electricity_usd_2026_kwh": 0.1267,
      "wacc": 0.0421,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.79,
      "electricity": 1.18,
      "site_grid": 1.46,
      "operations": 3.29,
      "total": 22.71,
      "electricity_usd_2026_kwh": 0.128,
      "wacc": 0.047,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.12,
      "electricity": 1.51,
      "site_grid": 1.7,
      "operations": 6.47,
      "total": 30.8,
      "electricity_usd_2026_kwh": 0.128,
      "wacc": 0.047,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.97,
      "electricity": 3.19,
      "site_grid": 3.12,
      "operations": 7.63,
      "total": 49.91,
      "electricity_usd_2026_kwh": 0.128,
      "wacc": 0.047,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.24,
      "electricity": 4.09,
      "site_grid": 3.65,
      "operations": 15.08,
      "total": 68.05,
      "electricity_usd_2026_kwh": 0.128,
      "wacc": 0.047,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.58,
      "electricity": 7.52,
      "site_grid": 6.91,
      "operations": 18.16,
      "total": 112.17,
      "electricity_usd_2026_kwh": 0.128,
      "wacc": 0.047,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.09,
      "electricity": 9.63,
      "site_grid": 8.07,
      "operations": 36.04,
      "total": 153.83,
      "electricity_usd_2026_kwh": 0.128,
      "wacc": 0.047,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.97,
      "electricity": 1.27,
      "site_grid": 1.55,
      "operations": 3.29,
      "total": 23.08,
      "electricity_usd_2026_kwh": 0.1376,
      "wacc": 0.0528,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.35,
      "electricity": 1.62,
      "site_grid": 1.8,
      "operations": 6.47,
      "total": 31.24,
      "electricity_usd_2026_kwh": 0.1376,
      "wacc": 0.0528,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.37,
      "electricity": 3.43,
      "site_grid": 3.33,
      "operations": 7.63,
      "total": 50.75,
      "electricity_usd_2026_kwh": 0.1376,
      "wacc": 0.0528,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.74,
      "electricity": 4.39,
      "site_grid": 3.85,
      "operations": 15.08,
      "total": 69.06,
      "electricity_usd_2026_kwh": 0.1376,
      "wacc": 0.0528,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.46,
      "electricity": 8.08,
      "site_grid": 7.36,
      "operations": 18.16,
      "total": 114.06,
      "electricity_usd_2026_kwh": 0.1376,
      "wacc": 0.0528,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.19,
      "electricity": 10.35,
      "site_grid": 8.53,
      "operations": 36.04,
      "total": 156.11,
      "electricity_usd_2026_kwh": 0.1376,
      "wacc": 0.0528,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.73,
      "electricity": 1.29,
      "site_grid": 1.53,
      "operations": 3.29,
      "total": 22.84,
      "electricity_usd_2026_kwh": 0.1405,
      "wacc": 0.0451,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.04,
      "electricity": 1.65,
      "site_grid": 1.79,
      "operations": 6.47,
      "total": 30.96,
      "electricity_usd_2026_kwh": 0.1405,
      "wacc": 0.0451,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.84,
      "electricity": 3.5,
      "site_grid": 3.28,
      "operations": 7.63,
      "total": 50.25,
      "electricity_usd_2026_kwh": 0.1405,
      "wacc": 0.0451,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.08,
      "electricity": 4.49,
      "site_grid": 3.84,
      "operations": 15.08,
      "total": 68.48,
      "electricity_usd_2026_kwh": 0.1405,
      "wacc": 0.0451,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.3,
      "electricity": 8.25,
      "site_grid": 7.25,
      "operations": 18.16,
      "total": 112.96,
      "electricity_usd_2026_kwh": 0.1405,
      "wacc": 0.0451,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.74,
      "electricity": 10.56,
      "site_grid": 8.49,
      "operations": 36.04,
      "total": 154.84,
      "electricity_usd_2026_kwh": 0.1405,
      "wacc": 0.0451,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.57,
      "electricity": 1.49,
      "site_grid": 1.5,
      "operations": 3.29,
      "total": 22.84,
      "electricity_usd_2026_kwh": 0.1615,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.64,
      "electricity": 1.9,
      "site_grid": 1.72,
      "operations": 6.47,
      "total": 30.73,
      "electricity_usd_2026_kwh": 0.1615,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.5,
      "electricity": 4.03,
      "site_grid": 3.21,
      "operations": 7.63,
      "total": 50.36,
      "electricity_usd_2026_kwh": 0.1615,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.23,
      "electricity": 5.16,
      "site_grid": 3.68,
      "operations": 15.08,
      "total": 68.14,
      "electricity_usd_2026_kwh": 0.1615,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.53,
      "electricity": 9.48,
      "site_grid": 7.11,
      "operations": 18.16,
      "total": 113.28,
      "electricity_usd_2026_kwh": 0.1615,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 97.85,
      "electricity": 12.15,
      "site_grid": 8.15,
      "operations": 36.04,
      "total": 154.18,
      "electricity_usd_2026_kwh": 0.1615,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.57,
      "electricity": 1.65,
      "site_grid": 1.51,
      "operations": 3.29,
      "total": 23.01,
      "electricity_usd_2026_kwh": 0.179,
      "wacc": 0.0382,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.77,
      "electricity": 2.11,
      "site_grid": 1.76,
      "operations": 6.47,
      "total": 31.11,
      "electricity_usd_2026_kwh": 0.179,
      "wacc": 0.0382,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.5,
      "electricity": 4.46,
      "site_grid": 3.23,
      "operations": 7.63,
      "total": 50.82,
      "electricity_usd_2026_kwh": 0.179,
      "wacc": 0.0382,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.49,
      "electricity": 5.72,
      "site_grid": 3.77,
      "operations": 15.08,
      "total": 69.06,
      "electricity_usd_2026_kwh": 0.179,
      "wacc": 0.0382,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.53,
      "electricity": 10.51,
      "site_grid": 7.14,
      "operations": 18.16,
      "total": 114.35,
      "electricity_usd_2026_kwh": 0.179,
      "wacc": 0.0382,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.44,
      "electricity": 13.46,
      "site_grid": 8.34,
      "operations": 36.04,
      "total": 156.28,
      "electricity_usd_2026_kwh": 0.179,
      "wacc": 0.0382,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.99,
      "electricity": 1.99,
      "site_grid": 1.87,
      "operations": 3.29,
      "total": 24.14,
      "electricity_usd_2026_kwh": 0.2161,
      "wacc": 0.0532,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.36,
      "electricity": 2.55,
      "site_grid": 2.17,
      "operations": 6.47,
      "total": 32.55,
      "electricity_usd_2026_kwh": 0.2161,
      "wacc": 0.0532,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.39,
      "electricity": 5.39,
      "site_grid": 4.02,
      "operations": 7.63,
      "total": 53.43,
      "electricity_usd_2026_kwh": 0.2161,
      "wacc": 0.0532,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.77,
      "electricity": 6.9,
      "site_grid": 4.65,
      "operations": 15.08,
      "total": 72.4,
      "electricity_usd_2026_kwh": 0.2161,
      "wacc": 0.0532,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.52,
      "electricity": 12.69,
      "site_grid": 8.89,
      "operations": 18.16,
      "total": 120.26,
      "electricity_usd_2026_kwh": 0.2161,
      "wacc": 0.0532,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.27,
      "electricity": 16.25,
      "site_grid": 10.29,
      "operations": 36.04,
      "total": 163.85,
      "electricity_usd_2026_kwh": 0.2161,
      "wacc": 0.0532,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.31,
      "electricity": 2.5,
      "site_grid": 2.08,
      "operations": 3.29,
      "total": 25.17,
      "electricity_usd_2026_kwh": 0.2714,
      "wacc": 0.0633,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.77,
      "electricity": 3.2,
      "site_grid": 2.37,
      "operations": 6.47,
      "total": 33.81,
      "electricity_usd_2026_kwh": 0.2714,
      "wacc": 0.0633,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.09,
      "electricity": 6.77,
      "site_grid": 4.45,
      "operations": 7.63,
      "total": 55.93,
      "electricity_usd_2026_kwh": 0.2714,
      "wacc": 0.0633,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.64,
      "electricity": 8.67,
      "site_grid": 5.08,
      "operations": 15.08,
      "total": 75.46,
      "electricity_usd_2026_kwh": 0.2714,
      "wacc": 0.0633,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.05,
      "electricity": 15.94,
      "site_grid": 9.84,
      "operations": 18.16,
      "total": 125.99,
      "electricity_usd_2026_kwh": 0.2714,
      "wacc": 0.0633,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.18,
      "electricity": 20.41,
      "site_grid": 11.24,
      "operations": 36.04,
      "total": 170.87,
      "electricity_usd_2026_kwh": 0.2714,
      "wacc": 0.0633,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.39,
      "electricity": 2.2,
      "site_grid": 2.04,
      "operations": 3.29,
      "total": 24.92,
      "electricity_usd_2026_kwh": 0.2393,
      "wacc": 0.0658,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.87,
      "electricity": 2.82,
      "site_grid": 2.33,
      "operations": 6.47,
      "total": 33.48,
      "electricity_usd_2026_kwh": 0.2393,
      "wacc": 0.0658,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.26,
      "electricity": 5.97,
      "site_grid": 4.38,
      "operations": 7.63,
      "total": 55.23,
      "electricity_usd_2026_kwh": 0.2393,
      "wacc": 0.0658,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.85,
      "electricity": 7.64,
      "site_grid": 4.99,
      "operations": 15.08,
      "total": 74.55,
      "electricity_usd_2026_kwh": 0.2393,
      "wacc": 0.0658,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.43,
      "electricity": 14.05,
      "site_grid": 9.68,
      "operations": 18.16,
      "total": 124.33,
      "electricity_usd_2026_kwh": 0.2393,
      "wacc": 0.0658,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.65,
      "electricity": 18.0,
      "site_grid": 11.03,
      "operations": 36.04,
      "total": 168.72,
      "electricity_usd_2026_kwh": 0.2393,
      "wacc": 0.0658,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.42,
      "electricity": 2.17,
      "site_grid": 2.03,
      "operations": 3.29,
      "total": 24.91,
      "electricity_usd_2026_kwh": 0.2362,
      "wacc": 0.0666,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.9,
      "electricity": 2.78,
      "site_grid": 2.31,
      "operations": 6.47,
      "total": 33.46,
      "electricity_usd_2026_kwh": 0.2362,
      "wacc": 0.0666,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.32,
      "electricity": 5.89,
      "site_grid": 4.35,
      "operations": 7.63,
      "total": 55.18,
      "electricity_usd_2026_kwh": 0.2362,
      "wacc": 0.0666,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.92,
      "electricity": 7.54,
      "site_grid": 4.94,
      "operations": 15.08,
      "total": 74.49,
      "electricity_usd_2026_kwh": 0.2362,
      "wacc": 0.0666,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.56,
      "electricity": 13.87,
      "site_grid": 9.61,
      "operations": 18.16,
      "total": 124.2,
      "electricity_usd_2026_kwh": 0.2362,
      "wacc": 0.0666,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.81,
      "electricity": 17.76,
      "site_grid": 10.94,
      "operations": 36.04,
      "total": 168.56,
      "electricity_usd_2026_kwh": 0.2362,
      "wacc": 0.0666,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.43,
      "electricity": 2.1,
      "site_grid": 2.04,
      "operations": 3.29,
      "total": 24.86,
      "electricity_usd_2026_kwh": 0.2283,
      "wacc": 0.067,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.92,
      "electricity": 2.69,
      "site_grid": 2.32,
      "operations": 6.47,
      "total": 33.39,
      "electricity_usd_2026_kwh": 0.2283,
      "wacc": 0.067,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.34,
      "electricity": 5.69,
      "site_grid": 4.37,
      "operations": 7.63,
      "total": 55.03,
      "electricity_usd_2026_kwh": 0.2283,
      "wacc": 0.067,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.96,
      "electricity": 7.29,
      "site_grid": 4.97,
      "operations": 15.08,
      "total": 74.29,
      "electricity_usd_2026_kwh": 0.2283,
      "wacc": 0.067,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.61,
      "electricity": 13.41,
      "site_grid": 9.66,
      "operations": 18.16,
      "total": 123.85,
      "electricity_usd_2026_kwh": 0.2283,
      "wacc": 0.067,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.89,
      "electricity": 17.17,
      "site_grid": 10.99,
      "operations": 36.04,
      "total": 168.09,
      "electricity_usd_2026_kwh": 0.2283,
      "wacc": 0.067,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.36,
      "electricity": 1.85,
      "site_grid": 1.41,
      "operations": 3.23,
      "total": 24.85,
      "electricity_usd_2026_kwh": 0.1976,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.13,
      "electricity": 2.38,
      "site_grid": 1.32,
      "operations": 5.59,
      "total": 32.42,
      "electricity_usd_2026_kwh": 0.1976,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.34,
      "electricity": 5.02,
      "site_grid": 3.01,
      "operations": 7.5,
      "total": 54.88,
      "electricity_usd_2026_kwh": 0.1976,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.56,
      "electricity": 6.44,
      "site_grid": 2.83,
      "operations": 13.2,
      "total": 72.03,
      "electricity_usd_2026_kwh": 0.1976,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.04,
      "electricity": 11.83,
      "site_grid": 6.66,
      "operations": 17.88,
      "total": 123.42,
      "electricity_usd_2026_kwh": 0.1976,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.65,
      "electricity": 15.17,
      "site_grid": 6.27,
      "operations": 31.89,
      "total": 162.98,
      "electricity_usd_2026_kwh": 0.1976,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.22,
      "electricity": 1.88,
      "site_grid": 1.35,
      "operations": 3.23,
      "total": 24.67,
      "electricity_usd_2026_kwh": 0.2,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.95,
      "electricity": 2.41,
      "site_grid": 1.27,
      "operations": 5.59,
      "total": 32.22,
      "electricity_usd_2026_kwh": 0.2,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.03,
      "electricity": 5.08,
      "site_grid": 2.89,
      "operations": 7.5,
      "total": 54.51,
      "electricity_usd_2026_kwh": 0.2,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.17,
      "electricity": 6.52,
      "site_grid": 2.73,
      "operations": 13.2,
      "total": 71.62,
      "electricity_usd_2026_kwh": 0.2,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.36,
      "electricity": 11.98,
      "site_grid": 6.39,
      "operations": 17.88,
      "total": 122.6,
      "electricity_usd_2026_kwh": 0.2,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.79,
      "electricity": 15.36,
      "site_grid": 6.04,
      "operations": 31.89,
      "total": 162.07,
      "electricity_usd_2026_kwh": 0.2,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.89,
      "electricity": 1.63,
      "site_grid": 1.27,
      "operations": 3.23,
      "total": 24.01,
      "electricity_usd_2026_kwh": 0.1733,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.54,
      "electricity": 2.08,
      "site_grid": 1.22,
      "operations": 5.59,
      "total": 31.43,
      "electricity_usd_2026_kwh": 0.1733,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.33,
      "electricity": 4.41,
      "site_grid": 2.72,
      "operations": 7.5,
      "total": 52.96,
      "electricity_usd_2026_kwh": 0.1733,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.29,
      "electricity": 5.65,
      "site_grid": 2.6,
      "operations": 13.2,
      "total": 69.74,
      "electricity_usd_2026_kwh": 0.1733,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.8,
      "electricity": 10.38,
      "site_grid": 6.02,
      "operations": 17.88,
      "total": 119.08,
      "electricity_usd_2026_kwh": 0.1733,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.84,
      "electricity": 13.31,
      "site_grid": 5.76,
      "operations": 31.89,
      "total": 157.8,
      "electricity_usd_2026_kwh": 0.1733,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.07,
      "electricity": 1.6,
      "site_grid": 1.33,
      "operations": 3.23,
      "total": 24.23,
      "electricity_usd_2026_kwh": 0.1704,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.77,
      "electricity": 2.05,
      "site_grid": 1.26,
      "operations": 5.59,
      "total": 31.67,
      "electricity_usd_2026_kwh": 0.1704,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.72,
      "electricity": 4.33,
      "site_grid": 2.85,
      "operations": 7.5,
      "total": 53.4,
      "electricity_usd_2026_kwh": 0.1704,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.78,
      "electricity": 5.56,
      "site_grid": 2.71,
      "operations": 13.2,
      "total": 70.24,
      "electricity_usd_2026_kwh": 0.1704,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.67,
      "electricity": 10.21,
      "site_grid": 6.29,
      "operations": 17.88,
      "total": 120.05,
      "electricity_usd_2026_kwh": 0.1704,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.93,
      "electricity": 13.09,
      "site_grid": 5.98,
      "operations": 31.89,
      "total": 158.89,
      "electricity_usd_2026_kwh": 0.1704,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.14,
      "electricity": 1.44,
      "site_grid": 1.37,
      "operations": 3.23,
      "total": 24.17,
      "electricity_usd_2026_kwh": 0.1538,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.85,
      "electricity": 1.85,
      "site_grid": 1.3,
      "operations": 5.59,
      "total": 31.59,
      "electricity_usd_2026_kwh": 0.1538,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.86,
      "electricity": 3.91,
      "site_grid": 2.93,
      "operations": 7.5,
      "total": 53.2,
      "electricity_usd_2026_kwh": 0.1538,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.95,
      "electricity": 5.02,
      "site_grid": 2.78,
      "operations": 13.2,
      "total": 69.94,
      "electricity_usd_2026_kwh": 0.1538,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.97,
      "electricity": 9.21,
      "site_grid": 6.47,
      "operations": 17.88,
      "total": 119.54,
      "electricity_usd_2026_kwh": 0.1538,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.31,
      "electricity": 11.81,
      "site_grid": 6.14,
      "operations": 31.89,
      "total": 158.15,
      "electricity_usd_2026_kwh": 0.1538,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.0,
      "electricity": 1.27,
      "site_grid": 1.35,
      "operations": 3.23,
      "total": 23.85,
      "electricity_usd_2026_kwh": 0.1349,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.68,
      "electricity": 1.62,
      "site_grid": 1.29,
      "operations": 5.59,
      "total": 31.18,
      "electricity_usd_2026_kwh": 0.1349,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.57,
      "electricity": 3.43,
      "site_grid": 2.9,
      "operations": 7.5,
      "total": 52.4,
      "electricity_usd_2026_kwh": 0.1349,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.59,
      "electricity": 4.4,
      "site_grid": 2.77,
      "operations": 13.2,
      "total": 68.96,
      "electricity_usd_2026_kwh": 0.1349,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.33,
      "electricity": 8.08,
      "site_grid": 6.42,
      "operations": 17.88,
      "total": 117.71,
      "electricity_usd_2026_kwh": 0.1349,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.51,
      "electricity": 10.36,
      "site_grid": 6.12,
      "operations": 31.89,
      "total": 155.88,
      "electricity_usd_2026_kwh": 0.1349,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.9,
      "electricity": 1.16,
      "site_grid": 1.32,
      "operations": 3.23,
      "total": 23.61,
      "electricity_usd_2026_kwh": 0.1237,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.56,
      "electricity": 1.49,
      "site_grid": 1.26,
      "operations": 5.59,
      "total": 30.9,
      "electricity_usd_2026_kwh": 0.1237,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.36,
      "electricity": 3.15,
      "site_grid": 2.82,
      "operations": 7.5,
      "total": 51.83,
      "electricity_usd_2026_kwh": 0.1237,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.32,
      "electricity": 4.03,
      "site_grid": 2.7,
      "operations": 13.2,
      "total": 68.26,
      "electricity_usd_2026_kwh": 0.1237,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.86,
      "electricity": 7.41,
      "site_grid": 6.25,
      "operations": 17.88,
      "total": 116.4,
      "electricity_usd_2026_kwh": 0.1237,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.91,
      "electricity": 9.5,
      "site_grid": 5.98,
      "operations": 31.89,
      "total": 154.28,
      "electricity_usd_2026_kwh": 0.1237,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.07,
      "electricity": 1.23,
      "site_grid": 1.37,
      "operations": 3.23,
      "total": 23.9,
      "electricity_usd_2026_kwh": 0.1317,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.76,
      "electricity": 1.58,
      "site_grid": 1.3,
      "operations": 5.59,
      "total": 31.24,
      "electricity_usd_2026_kwh": 0.1317,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.71,
      "electricity": 3.35,
      "site_grid": 2.93,
      "operations": 7.5,
      "total": 52.49,
      "electricity_usd_2026_kwh": 0.1317,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.77,
      "electricity": 4.29,
      "site_grid": 2.79,
      "operations": 13.2,
      "total": 69.04,
      "electricity_usd_2026_kwh": 0.1317,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.64,
      "electricity": 7.88,
      "site_grid": 6.48,
      "operations": 17.88,
      "total": 117.89,
      "electricity_usd_2026_kwh": 0.1317,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.89,
      "electricity": 10.11,
      "site_grid": 6.17,
      "operations": 31.89,
      "total": 156.05,
      "electricity_usd_2026_kwh": 0.1317,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.26,
      "electricity": 1.28,
      "site_grid": 1.45,
      "operations": 3.23,
      "total": 24.23,
      "electricity_usd_2026_kwh": 0.1368,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.0,
      "electricity": 1.65,
      "site_grid": 1.37,
      "operations": 5.59,
      "total": 31.61,
      "electricity_usd_2026_kwh": 0.1368,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.13,
      "electricity": 3.48,
      "site_grid": 3.11,
      "operations": 7.5,
      "total": 53.22,
      "electricity_usd_2026_kwh": 0.1368,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.29,
      "electricity": 4.46,
      "site_grid": 2.94,
      "operations": 13.2,
      "total": 69.89,
      "electricity_usd_2026_kwh": 0.1368,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.56,
      "electricity": 8.19,
      "site_grid": 6.89,
      "operations": 17.88,
      "total": 119.52,
      "electricity_usd_2026_kwh": 0.1368,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.04,
      "electricity": 10.51,
      "site_grid": 6.5,
      "operations": 31.89,
      "total": 157.94,
      "electricity_usd_2026_kwh": 0.1368,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.0,
      "electricity": 1.24,
      "site_grid": 1.44,
      "operations": 3.23,
      "total": 23.91,
      "electricity_usd_2026_kwh": 0.1326,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.68,
      "electricity": 1.59,
      "site_grid": 1.37,
      "operations": 5.59,
      "total": 31.24,
      "electricity_usd_2026_kwh": 0.1326,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.57,
      "electricity": 3.37,
      "site_grid": 3.08,
      "operations": 7.5,
      "total": 52.52,
      "electricity_usd_2026_kwh": 0.1326,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.6,
      "electricity": 4.32,
      "site_grid": 2.93,
      "operations": 13.2,
      "total": 69.05,
      "electricity_usd_2026_kwh": 0.1326,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.34,
      "electricity": 7.94,
      "site_grid": 6.81,
      "operations": 17.88,
      "total": 117.97,
      "electricity_usd_2026_kwh": 0.1326,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.51,
      "electricity": 10.18,
      "site_grid": 6.49,
      "operations": 31.89,
      "total": 156.08,
      "electricity_usd_2026_kwh": 0.1326,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.59,
      "electricity": 1.48,
      "site_grid": 1.34,
      "operations": 3.23,
      "total": 23.64,
      "electricity_usd_2026_kwh": 0.1577,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.16,
      "electricity": 1.9,
      "site_grid": 1.3,
      "operations": 5.59,
      "total": 30.95,
      "electricity_usd_2026_kwh": 0.1577,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.68,
      "electricity": 4.01,
      "site_grid": 2.87,
      "operations": 7.5,
      "total": 52.07,
      "electricity_usd_2026_kwh": 0.1577,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.48,
      "electricity": 5.14,
      "site_grid": 2.79,
      "operations": 13.2,
      "total": 68.6,
      "electricity_usd_2026_kwh": 0.1577,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.36,
      "electricity": 9.45,
      "site_grid": 6.36,
      "operations": 17.88,
      "total": 117.05,
      "electricity_usd_2026_kwh": 0.1577,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.04,
      "electricity": 12.11,
      "site_grid": 6.16,
      "operations": 31.89,
      "total": 155.21,
      "electricity_usd_2026_kwh": 0.1577,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.77,
      "electricity": 1.49,
      "site_grid": 1.4,
      "operations": 3.23,
      "total": 23.89,
      "electricity_usd_2026_kwh": 0.1585,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.39,
      "electricity": 1.91,
      "site_grid": 1.35,
      "operations": 5.59,
      "total": 31.24,
      "electricity_usd_2026_kwh": 0.1585,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.08,
      "electricity": 4.03,
      "site_grid": 3.0,
      "operations": 7.5,
      "total": 52.61,
      "electricity_usd_2026_kwh": 0.1585,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.98,
      "electricity": 5.17,
      "site_grid": 2.89,
      "operations": 13.2,
      "total": 69.23,
      "electricity_usd_2026_kwh": 0.1585,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.24,
      "electricity": 9.49,
      "site_grid": 6.64,
      "operations": 17.88,
      "total": 118.26,
      "electricity_usd_2026_kwh": 0.1585,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.14,
      "electricity": 12.17,
      "site_grid": 6.39,
      "operations": 31.89,
      "total": 156.59,
      "electricity_usd_2026_kwh": 0.1585,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.28,
      "electricity": 1.82,
      "site_grid": 1.75,
      "operations": 3.23,
      "total": 25.07,
      "electricity_usd_2026_kwh": 0.1937,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.02,
      "electricity": 2.33,
      "site_grid": 1.66,
      "operations": 5.59,
      "total": 32.6,
      "electricity_usd_2026_kwh": 0.1937,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.15,
      "electricity": 4.93,
      "site_grid": 3.76,
      "operations": 7.5,
      "total": 55.34,
      "electricity_usd_2026_kwh": 0.1937,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.32,
      "electricity": 6.32,
      "site_grid": 3.55,
      "operations": 13.2,
      "total": 72.38,
      "electricity_usd_2026_kwh": 0.1937,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.62,
      "electricity": 11.6,
      "site_grid": 8.32,
      "operations": 17.88,
      "total": 124.42,
      "electricity_usd_2026_kwh": 0.1937,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.12,
      "electricity": 14.88,
      "site_grid": 7.85,
      "operations": 31.89,
      "total": 163.74,
      "electricity_usd_2026_kwh": 0.1937,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.61,
      "electricity": 2.34,
      "site_grid": 1.93,
      "operations": 3.23,
      "total": 26.12,
      "electricity_usd_2026_kwh": 0.2495,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.45,
      "electricity": 3.0,
      "site_grid": 1.8,
      "operations": 5.59,
      "total": 33.84,
      "electricity_usd_2026_kwh": 0.2495,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.88,
      "electricity": 6.35,
      "site_grid": 4.14,
      "operations": 7.5,
      "total": 57.87,
      "electricity_usd_2026_kwh": 0.2495,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.23,
      "electricity": 8.14,
      "site_grid": 3.86,
      "operations": 13.2,
      "total": 75.43,
      "electricity_usd_2026_kwh": 0.2495,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.23,
      "electricity": 14.94,
      "site_grid": 9.16,
      "operations": 17.88,
      "total": 130.22,
      "electricity_usd_2026_kwh": 0.2495,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.13,
      "electricity": 19.16,
      "site_grid": 8.55,
      "operations": 31.89,
      "total": 170.74,
      "electricity_usd_2026_kwh": 0.2495,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.7,
      "electricity": 2.24,
      "site_grid": 1.9,
      "operations": 3.23,
      "total": 26.06,
      "electricity_usd_2026_kwh": 0.2385,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.55,
      "electricity": 2.87,
      "site_grid": 1.77,
      "operations": 5.59,
      "total": 33.78,
      "electricity_usd_2026_kwh": 0.2385,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.06,
      "electricity": 6.06,
      "site_grid": 4.07,
      "operations": 7.5,
      "total": 57.7,
      "electricity_usd_2026_kwh": 0.2385,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.46,
      "electricity": 7.78,
      "site_grid": 3.79,
      "operations": 13.2,
      "total": 75.22,
      "electricity_usd_2026_kwh": 0.2385,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.63,
      "electricity": 14.28,
      "site_grid": 9.01,
      "operations": 17.88,
      "total": 129.8,
      "electricity_usd_2026_kwh": 0.2385,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.63,
      "electricity": 18.31,
      "site_grid": 8.38,
      "operations": 31.89,
      "total": 170.22,
      "electricity_usd_2026_kwh": 0.2385,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.73,
      "electricity": 2.13,
      "site_grid": 1.89,
      "operations": 3.23,
      "total": 25.97,
      "electricity_usd_2026_kwh": 0.2268,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.59,
      "electricity": 2.73,
      "site_grid": 1.75,
      "operations": 5.59,
      "total": 33.66,
      "electricity_usd_2026_kwh": 0.2268,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.12,
      "electricity": 5.77,
      "site_grid": 4.04,
      "operations": 7.5,
      "total": 57.43,
      "electricity_usd_2026_kwh": 0.2268,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.54,
      "electricity": 7.4,
      "site_grid": 3.76,
      "operations": 13.2,
      "total": 74.89,
      "electricity_usd_2026_kwh": 0.2268,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.77,
      "electricity": 13.58,
      "site_grid": 8.94,
      "operations": 17.88,
      "total": 129.17,
      "electricity_usd_2026_kwh": 0.2268,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.8,
      "electricity": 17.42,
      "site_grid": 8.31,
      "operations": 31.89,
      "total": 169.42,
      "electricity_usd_2026_kwh": 0.2268,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.74,
      "electricity": 2.06,
      "site_grid": 1.9,
      "operations": 3.23,
      "total": 25.92,
      "electricity_usd_2026_kwh": 0.2196,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.6,
      "electricity": 2.64,
      "site_grid": 1.76,
      "operations": 5.59,
      "total": 33.6,
      "electricity_usd_2026_kwh": 0.2196,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.15,
      "electricity": 5.58,
      "site_grid": 4.06,
      "operations": 7.5,
      "total": 57.3,
      "electricity_usd_2026_kwh": 0.2196,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.57,
      "electricity": 7.16,
      "site_grid": 3.77,
      "operations": 13.2,
      "total": 74.7,
      "electricity_usd_2026_kwh": 0.2196,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.83,
      "electricity": 13.15,
      "site_grid": 8.99,
      "operations": 17.88,
      "total": 128.85,
      "electricity_usd_2026_kwh": 0.2196,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.88,
      "electricity": 16.86,
      "site_grid": 8.35,
      "operations": 31.89,
      "total": 168.98,
      "electricity_usd_2026_kwh": 0.2196,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.14,
      "electricity": 1.83,
      "site_grid": 1.36,
      "operations": 3.28,
      "total": 24.61,
      "electricity_usd_2026_kwh": 0.1864,
      "wacc": 0.0668,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.86,
      "electricity": 2.34,
      "site_grid": 1.26,
      "operations": 5.77,
      "total": 32.23,
      "electricity_usd_2026_kwh": 0.1864,
      "wacc": 0.0668,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.86,
      "electricity": 4.96,
      "site_grid": 2.92,
      "operations": 7.62,
      "total": 54.35,
      "electricity_usd_2026_kwh": 0.1864,
      "wacc": 0.0668,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.98,
      "electricity": 6.35,
      "site_grid": 2.7,
      "operations": 13.58,
      "total": 71.61,
      "electricity_usd_2026_kwh": 0.1864,
      "wacc": 0.0668,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.97,
      "electricity": 11.68,
      "site_grid": 6.46,
      "operations": 18.14,
      "total": 122.24,
      "electricity_usd_2026_kwh": 0.1864,
      "wacc": 0.0668,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.36,
      "electricity": 14.96,
      "site_grid": 5.98,
      "operations": 32.73,
      "total": 162.04,
      "electricity_usd_2026_kwh": 0.1864,
      "wacc": 0.0668,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.17,
      "electricity": 2.01,
      "site_grid": 1.63,
      "operations": 3.28,
      "total": 26.09,
      "electricity_usd_2026_kwh": 0.2048,
      "wacc": 0.0975,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.16,
      "electricity": 2.57,
      "site_grid": 1.46,
      "operations": 5.77,
      "total": 33.96,
      "electricity_usd_2026_kwh": 0.2048,
      "wacc": 0.0975,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.08,
      "electricity": 5.45,
      "site_grid": 3.49,
      "operations": 7.62,
      "total": 57.63,
      "electricity_usd_2026_kwh": 0.2048,
      "wacc": 0.0975,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.76,
      "electricity": 6.98,
      "site_grid": 3.12,
      "operations": 13.58,
      "total": 75.44,
      "electricity_usd_2026_kwh": 0.2048,
      "wacc": 0.0975,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.88,
      "electricity": 12.83,
      "site_grid": 7.72,
      "operations": 18.14,
      "total": 129.56,
      "electricity_usd_2026_kwh": 0.2048,
      "wacc": 0.0975,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 114.51,
      "electricity": 16.44,
      "site_grid": 6.91,
      "operations": 32.73,
      "total": 170.59,
      "electricity_usd_2026_kwh": 0.2048,
      "wacc": 0.0975,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.01,
      "electricity": 2.08,
      "site_grid": 1.59,
      "operations": 3.28,
      "total": 25.96,
      "electricity_usd_2026_kwh": 0.212,
      "wacc": 0.0927,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.95,
      "electricity": 2.67,
      "site_grid": 1.43,
      "operations": 5.77,
      "total": 33.82,
      "electricity_usd_2026_kwh": 0.212,
      "wacc": 0.0927,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.73,
      "electricity": 5.64,
      "site_grid": 3.41,
      "operations": 7.62,
      "total": 57.39,
      "electricity_usd_2026_kwh": 0.212,
      "wacc": 0.0927,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.32,
      "electricity": 7.23,
      "site_grid": 3.06,
      "operations": 13.58,
      "total": 75.19,
      "electricity_usd_2026_kwh": 0.212,
      "wacc": 0.0927,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.1,
      "electricity": 13.28,
      "site_grid": 7.54,
      "operations": 18.14,
      "total": 129.06,
      "electricity_usd_2026_kwh": 0.212,
      "wacc": 0.0927,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 113.55,
      "electricity": 17.02,
      "site_grid": 6.78,
      "operations": 32.73,
      "total": 170.08,
      "electricity_usd_2026_kwh": 0.212,
      "wacc": 0.0927,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.69,
      "electricity": 2.12,
      "site_grid": 1.51,
      "operations": 3.28,
      "total": 25.6,
      "electricity_usd_2026_kwh": 0.2159,
      "wacc": 0.0832,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.55,
      "electricity": 2.71,
      "site_grid": 1.37,
      "operations": 5.77,
      "total": 33.41,
      "electricity_usd_2026_kwh": 0.2159,
      "wacc": 0.0832,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.04,
      "electricity": 5.74,
      "site_grid": 3.24,
      "operations": 7.62,
      "total": 56.63,
      "electricity_usd_2026_kwh": 0.2159,
      "wacc": 0.0832,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.46,
      "electricity": 7.36,
      "site_grid": 2.94,
      "operations": 13.58,
      "total": 74.33,
      "electricity_usd_2026_kwh": 0.2159,
      "wacc": 0.0832,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.57,
      "electricity": 13.52,
      "site_grid": 7.17,
      "operations": 18.14,
      "total": 127.41,
      "electricity_usd_2026_kwh": 0.2159,
      "wacc": 0.0832,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.63,
      "electricity": 17.33,
      "site_grid": 6.51,
      "operations": 32.73,
      "total": 168.2,
      "electricity_usd_2026_kwh": 0.2159,
      "wacc": 0.0832,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.25,
      "electricity": 2.14,
      "site_grid": 1.41,
      "operations": 3.28,
      "total": 25.08,
      "electricity_usd_2026_kwh": 0.218,
      "wacc": 0.0701,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.0,
      "electricity": 2.74,
      "site_grid": 1.3,
      "operations": 5.77,
      "total": 32.81,
      "electricity_usd_2026_kwh": 0.218,
      "wacc": 0.0701,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.09,
      "electricity": 5.8,
      "site_grid": 3.03,
      "operations": 7.62,
      "total": 55.53,
      "electricity_usd_2026_kwh": 0.218,
      "wacc": 0.0701,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.27,
      "electricity": 7.43,
      "site_grid": 2.79,
      "operations": 13.58,
      "total": 73.07,
      "electricity_usd_2026_kwh": 0.218,
      "wacc": 0.0701,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.48,
      "electricity": 13.65,
      "site_grid": 6.7,
      "operations": 18.14,
      "total": 124.98,
      "electricity_usd_2026_kwh": 0.218,
      "wacc": 0.0701,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.01,
      "electricity": 17.5,
      "site_grid": 6.18,
      "operations": 32.73,
      "total": 165.42,
      "electricity_usd_2026_kwh": 0.218,
      "wacc": 0.0701,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.78,
      "electricity": 1.74,
      "site_grid": 1.31,
      "operations": 3.28,
      "total": 24.11,
      "electricity_usd_2026_kwh": 0.1776,
      "wacc": 0.0561,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.41,
      "electricity": 2.23,
      "site_grid": 1.23,
      "operations": 5.77,
      "total": 31.64,
      "electricity_usd_2026_kwh": 0.1776,
      "wacc": 0.0561,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.09,
      "electricity": 4.72,
      "site_grid": 2.81,
      "operations": 7.62,
      "total": 53.23,
      "electricity_usd_2026_kwh": 0.1776,
      "wacc": 0.0561,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.02,
      "electricity": 6.05,
      "site_grid": 2.63,
      "operations": 13.58,
      "total": 70.28,
      "electricity_usd_2026_kwh": 0.1776,
      "wacc": 0.0561,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.26,
      "electricity": 11.12,
      "site_grid": 6.21,
      "operations": 18.14,
      "total": 119.74,
      "electricity_usd_2026_kwh": 0.1776,
      "wacc": 0.0561,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.23,
      "electricity": 14.25,
      "site_grid": 5.83,
      "operations": 32.73,
      "total": 159.05,
      "electricity_usd_2026_kwh": 0.1776,
      "wacc": 0.0561,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.68,
      "electricity": 1.69,
      "site_grid": 1.28,
      "operations": 3.28,
      "total": 23.92,
      "electricity_usd_2026_kwh": 0.1721,
      "wacc": 0.0531,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.29,
      "electricity": 2.16,
      "site_grid": 1.2,
      "operations": 5.77,
      "total": 31.42,
      "electricity_usd_2026_kwh": 0.1721,
      "wacc": 0.0531,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.87,
      "electricity": 4.58,
      "site_grid": 2.73,
      "operations": 7.62,
      "total": 52.8,
      "electricity_usd_2026_kwh": 0.1721,
      "wacc": 0.0531,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.75,
      "electricity": 5.86,
      "site_grid": 2.57,
      "operations": 13.58,
      "total": 69.76,
      "electricity_usd_2026_kwh": 0.1721,
      "wacc": 0.0531,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.79,
      "electricity": 10.78,
      "site_grid": 6.05,
      "operations": 18.14,
      "total": 118.75,
      "electricity_usd_2026_kwh": 0.1721,
      "wacc": 0.0531,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.64,
      "electricity": 13.81,
      "site_grid": 5.7,
      "operations": 32.73,
      "total": 157.88,
      "electricity_usd_2026_kwh": 0.1721,
      "wacc": 0.0531,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.84,
      "electricity": 1.71,
      "site_grid": 1.32,
      "operations": 3.28,
      "total": 24.16,
      "electricity_usd_2026_kwh": 0.1746,
      "wacc": 0.058,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.49,
      "electricity": 2.2,
      "site_grid": 1.24,
      "operations": 5.77,
      "total": 31.69,
      "electricity_usd_2026_kwh": 0.1746,
      "wacc": 0.058,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.22,
      "electricity": 4.64,
      "site_grid": 2.84,
      "operations": 7.62,
      "total": 53.32,
      "electricity_usd_2026_kwh": 0.1746,
      "wacc": 0.058,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.19,
      "electricity": 5.95,
      "site_grid": 2.66,
      "operations": 13.58,
      "total": 70.37,
      "electricity_usd_2026_kwh": 0.1746,
      "wacc": 0.058,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.56,
      "electricity": 10.94,
      "site_grid": 6.28,
      "operations": 18.14,
      "total": 119.92,
      "electricity_usd_2026_kwh": 0.1746,
      "wacc": 0.058,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.61,
      "electricity": 14.02,
      "site_grid": 5.88,
      "operations": 32.73,
      "total": 159.23,
      "electricity_usd_2026_kwh": 0.1746,
      "wacc": 0.058,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.03,
      "electricity": 1.75,
      "site_grid": 1.41,
      "operations": 3.28,
      "total": 24.47,
      "electricity_usd_2026_kwh": 0.1782,
      "wacc": 0.0638,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.73,
      "electricity": 2.24,
      "site_grid": 1.31,
      "operations": 5.77,
      "total": 32.05,
      "electricity_usd_2026_kwh": 0.1782,
      "wacc": 0.0638,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.64,
      "electricity": 4.74,
      "site_grid": 3.02,
      "operations": 7.62,
      "total": 54.01,
      "electricity_usd_2026_kwh": 0.1782,
      "wacc": 0.0638,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.71,
      "electricity": 6.08,
      "site_grid": 2.8,
      "operations": 13.58,
      "total": 71.16,
      "electricity_usd_2026_kwh": 0.1782,
      "wacc": 0.0638,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.48,
      "electricity": 11.16,
      "site_grid": 6.68,
      "operations": 18.14,
      "total": 121.46,
      "electricity_usd_2026_kwh": 0.1782,
      "wacc": 0.0638,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.76,
      "electricity": 14.31,
      "site_grid": 6.2,
      "operations": 32.73,
      "total": 161.0,
      "electricity_usd_2026_kwh": 0.1782,
      "wacc": 0.0638,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.78,
      "electricity": 1.65,
      "site_grid": 1.39,
      "operations": 3.28,
      "total": 24.1,
      "electricity_usd_2026_kwh": 0.1681,
      "wacc": 0.0561,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.41,
      "electricity": 2.11,
      "site_grid": 1.31,
      "operations": 5.77,
      "total": 31.6,
      "electricity_usd_2026_kwh": 0.1681,
      "wacc": 0.0561,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.09,
      "electricity": 4.47,
      "site_grid": 2.98,
      "operations": 7.62,
      "total": 53.15,
      "electricity_usd_2026_kwh": 0.1681,
      "wacc": 0.0561,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.02,
      "electricity": 5.73,
      "site_grid": 2.8,
      "operations": 13.58,
      "total": 70.12,
      "electricity_usd_2026_kwh": 0.1681,
      "wacc": 0.0561,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.27,
      "electricity": 10.53,
      "site_grid": 6.59,
      "operations": 18.14,
      "total": 119.53,
      "electricity_usd_2026_kwh": 0.1681,
      "wacc": 0.0561,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.24,
      "electricity": 13.49,
      "site_grid": 6.19,
      "operations": 32.73,
      "total": 158.64,
      "electricity_usd_2026_kwh": 0.1681,
      "wacc": 0.0561,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.36,
      "electricity": 1.6,
      "site_grid": 1.3,
      "operations": 3.28,
      "total": 23.54,
      "electricity_usd_2026_kwh": 0.1633,
      "wacc": 0.0436,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.89,
      "electricity": 2.05,
      "site_grid": 1.24,
      "operations": 5.77,
      "total": 30.95,
      "electricity_usd_2026_kwh": 0.1633,
      "wacc": 0.0436,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.2,
      "electricity": 4.34,
      "site_grid": 2.78,
      "operations": 7.62,
      "total": 51.94,
      "electricity_usd_2026_kwh": 0.1633,
      "wacc": 0.0436,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.91,
      "electricity": 5.56,
      "site_grid": 2.65,
      "operations": 13.58,
      "total": 68.7,
      "electricity_usd_2026_kwh": 0.1633,
      "wacc": 0.0436,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.3,
      "electricity": 10.23,
      "site_grid": 6.15,
      "operations": 18.14,
      "total": 116.81,
      "electricity_usd_2026_kwh": 0.1633,
      "wacc": 0.0436,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.77,
      "electricity": 13.1,
      "site_grid": 5.86,
      "operations": 32.73,
      "total": 155.47,
      "electricity_usd_2026_kwh": 0.1633,
      "wacc": 0.0436,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.55,
      "electricity": 1.59,
      "site_grid": 1.36,
      "operations": 3.28,
      "total": 23.78,
      "electricity_usd_2026_kwh": 0.1625,
      "wacc": 0.0492,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.12,
      "electricity": 2.04,
      "site_grid": 1.28,
      "operations": 5.77,
      "total": 31.22,
      "electricity_usd_2026_kwh": 0.1625,
      "wacc": 0.0492,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.6,
      "electricity": 4.32,
      "site_grid": 2.9,
      "operations": 7.62,
      "total": 52.44,
      "electricity_usd_2026_kwh": 0.1625,
      "wacc": 0.0492,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.4,
      "electricity": 5.54,
      "site_grid": 2.75,
      "operations": 13.58,
      "total": 69.26,
      "electricity_usd_2026_kwh": 0.1625,
      "wacc": 0.0492,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.18,
      "electricity": 10.18,
      "site_grid": 6.42,
      "operations": 18.14,
      "total": 117.92,
      "electricity_usd_2026_kwh": 0.1625,
      "wacc": 0.0492,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.87,
      "electricity": 13.04,
      "site_grid": 6.08,
      "operations": 32.73,
      "total": 156.73,
      "electricity_usd_2026_kwh": 0.1625,
      "wacc": 0.0492,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.05,
      "electricity": 1.49,
      "site_grid": 1.7,
      "operations": 3.28,
      "total": 24.52,
      "electricity_usd_2026_kwh": 0.1523,
      "wacc": 0.0642,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.75,
      "electricity": 1.91,
      "site_grid": 1.58,
      "operations": 5.77,
      "total": 32.01,
      "electricity_usd_2026_kwh": 0.1523,
      "wacc": 0.0642,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.67,
      "electricity": 4.05,
      "site_grid": 3.64,
      "operations": 7.62,
      "total": 53.98,
      "electricity_usd_2026_kwh": 0.1523,
      "wacc": 0.0642,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.74,
      "electricity": 5.19,
      "site_grid": 3.38,
      "operations": 13.58,
      "total": 70.89,
      "electricity_usd_2026_kwh": 0.1523,
      "wacc": 0.0642,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.55,
      "electricity": 9.54,
      "site_grid": 8.06,
      "operations": 18.14,
      "total": 121.29,
      "electricity_usd_2026_kwh": 0.1523,
      "wacc": 0.0642,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.84,
      "electricity": 12.23,
      "site_grid": 7.49,
      "operations": 32.73,
      "total": 160.28,
      "electricity_usd_2026_kwh": 0.1523,
      "wacc": 0.0642,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.39,
      "electricity": 1.22,
      "site_grid": 1.88,
      "operations": 3.28,
      "total": 24.76,
      "electricity_usd_2026_kwh": 0.1241,
      "wacc": 0.0743,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.17,
      "electricity": 1.56,
      "site_grid": 1.72,
      "operations": 5.77,
      "total": 32.22,
      "electricity_usd_2026_kwh": 0.1241,
      "wacc": 0.0743,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.39,
      "electricity": 3.3,
      "site_grid": 4.02,
      "operations": 7.62,
      "total": 54.33,
      "electricity_usd_2026_kwh": 0.1241,
      "wacc": 0.0743,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.65,
      "electricity": 4.23,
      "site_grid": 3.69,
      "operations": 13.58,
      "total": 71.15,
      "electricity_usd_2026_kwh": 0.1241,
      "wacc": 0.0743,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.15,
      "electricity": 7.77,
      "site_grid": 8.9,
      "operations": 18.14,
      "total": 121.96,
      "electricity_usd_2026_kwh": 0.1241,
      "wacc": 0.0743,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.85,
      "electricity": 9.96,
      "site_grid": 8.16,
      "operations": 32.73,
      "total": 160.7,
      "electricity_usd_2026_kwh": 0.1241,
      "wacc": 0.0743,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.47,
      "electricity": 1.39,
      "site_grid": 1.85,
      "operations": 3.28,
      "total": 24.99,
      "electricity_usd_2026_kwh": 0.1414,
      "wacc": 0.0768,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.28,
      "electricity": 1.78,
      "site_grid": 1.69,
      "operations": 5.77,
      "total": 32.51,
      "electricity_usd_2026_kwh": 0.1414,
      "wacc": 0.0768,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.57,
      "electricity": 3.76,
      "site_grid": 3.96,
      "operations": 7.62,
      "total": 54.9,
      "electricity_usd_2026_kwh": 0.1414,
      "wacc": 0.0768,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.88,
      "electricity": 4.82,
      "site_grid": 3.62,
      "operations": 13.58,
      "total": 71.89,
      "electricity_usd_2026_kwh": 0.1414,
      "wacc": 0.0768,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.55,
      "electricity": 8.86,
      "site_grid": 8.75,
      "operations": 18.14,
      "total": 123.3,
      "electricity_usd_2026_kwh": 0.1414,
      "wacc": 0.0768,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.34,
      "electricity": 11.35,
      "site_grid": 8.0,
      "operations": 32.73,
      "total": 162.43,
      "electricity_usd_2026_kwh": 0.1414,
      "wacc": 0.0768,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.5,
      "electricity": 1.51,
      "site_grid": 1.83,
      "operations": 3.28,
      "total": 25.12,
      "electricity_usd_2026_kwh": 0.1538,
      "wacc": 0.0776,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.32,
      "electricity": 1.93,
      "site_grid": 1.67,
      "operations": 5.77,
      "total": 32.69,
      "electricity_usd_2026_kwh": 0.1538,
      "wacc": 0.0776,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.63,
      "electricity": 4.09,
      "site_grid": 3.93,
      "operations": 7.62,
      "total": 55.26,
      "electricity_usd_2026_kwh": 0.1538,
      "wacc": 0.0776,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.95,
      "electricity": 5.24,
      "site_grid": 3.59,
      "operations": 13.58,
      "total": 72.36,
      "electricity_usd_2026_kwh": 0.1538,
      "wacc": 0.0776,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.68,
      "electricity": 9.63,
      "site_grid": 8.69,
      "operations": 18.14,
      "total": 124.14,
      "electricity_usd_2026_kwh": 0.1538,
      "wacc": 0.0776,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.51,
      "electricity": 12.34,
      "site_grid": 7.94,
      "operations": 32.73,
      "total": 163.53,
      "electricity_usd_2026_kwh": 0.1538,
      "wacc": 0.0776,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.51,
      "electricity": 1.5,
      "site_grid": 1.84,
      "operations": 3.28,
      "total": 25.13,
      "electricity_usd_2026_kwh": 0.1524,
      "wacc": 0.078,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.33,
      "electricity": 1.92,
      "site_grid": 1.68,
      "operations": 5.77,
      "total": 32.7,
      "electricity_usd_2026_kwh": 0.1524,
      "wacc": 0.078,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.66,
      "electricity": 4.05,
      "site_grid": 3.95,
      "operations": 7.62,
      "total": 55.27,
      "electricity_usd_2026_kwh": 0.1524,
      "wacc": 0.078,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.99,
      "electricity": 5.19,
      "site_grid": 3.6,
      "operations": 13.58,
      "total": 72.36,
      "electricity_usd_2026_kwh": 0.1524,
      "wacc": 0.078,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.74,
      "electricity": 9.55,
      "site_grid": 8.73,
      "operations": 18.14,
      "total": 124.16,
      "electricity_usd_2026_kwh": 0.1524,
      "wacc": 0.078,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.59,
      "electricity": 12.23,
      "site_grid": 7.97,
      "operations": 32.73,
      "total": 163.53,
      "electricity_usd_2026_kwh": 0.1524,
      "wacc": 0.078,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.19,
      "electricity": 1.61,
      "site_grid": 1.45,
      "operations": 3.26,
      "total": 25.51,
      "electricity_usd_2026_kwh": 0.1666,
      "wacc": 0.0868,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.23,
      "electricity": 2.07,
      "site_grid": 1.28,
      "operations": 5.45,
      "total": 33.02,
      "electricity_usd_2026_kwh": 0.1666,
      "wacc": 0.0868,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.11,
      "electricity": 4.36,
      "site_grid": 3.12,
      "operations": 7.56,
      "total": 56.15,
      "electricity_usd_2026_kwh": 0.1666,
      "wacc": 0.0868,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.9,
      "electricity": 5.6,
      "site_grid": 2.74,
      "operations": 12.89,
      "total": 73.14,
      "electricity_usd_2026_kwh": 0.1666,
      "wacc": 0.0868,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.95,
      "electricity": 10.27,
      "site_grid": 6.9,
      "operations": 18.02,
      "total": 126.13,
      "electricity_usd_2026_kwh": 0.1666,
      "wacc": 0.0868,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 114.83,
      "electricity": 13.19,
      "site_grid": 6.06,
      "operations": 31.23,
      "total": 165.32,
      "electricity_usd_2026_kwh": 0.1666,
      "wacc": 0.0868,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.04,
      "electricity": 1.59,
      "site_grid": 1.4,
      "operations": 3.26,
      "total": 25.28,
      "electricity_usd_2026_kwh": 0.1643,
      "wacc": 0.0825,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.04,
      "electricity": 2.04,
      "site_grid": 1.23,
      "operations": 5.45,
      "total": 32.76,
      "electricity_usd_2026_kwh": 0.1643,
      "wacc": 0.0825,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.79,
      "electricity": 4.3,
      "site_grid": 2.99,
      "operations": 7.56,
      "total": 55.64,
      "electricity_usd_2026_kwh": 0.1643,
      "wacc": 0.0825,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.5,
      "electricity": 5.52,
      "site_grid": 2.65,
      "operations": 12.89,
      "total": 72.56,
      "electricity_usd_2026_kwh": 0.1643,
      "wacc": 0.0825,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.24,
      "electricity": 10.12,
      "site_grid": 6.62,
      "operations": 18.02,
      "total": 125.01,
      "electricity_usd_2026_kwh": 0.1643,
      "wacc": 0.0825,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 113.94,
      "electricity": 13.0,
      "site_grid": 5.85,
      "operations": 31.23,
      "total": 164.03,
      "electricity_usd_2026_kwh": 0.1643,
      "wacc": 0.0825,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.7,
      "electricity": 1.43,
      "site_grid": 1.32,
      "operations": 3.26,
      "total": 24.7,
      "electricity_usd_2026_kwh": 0.1477,
      "wacc": 0.0727,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.62,
      "electricity": 1.83,
      "site_grid": 1.18,
      "operations": 5.45,
      "total": 32.07,
      "electricity_usd_2026_kwh": 0.1477,
      "wacc": 0.0727,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.07,
      "electricity": 3.87,
      "site_grid": 2.83,
      "operations": 7.56,
      "total": 54.32,
      "electricity_usd_2026_kwh": 0.1477,
      "wacc": 0.0727,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.6,
      "electricity": 4.96,
      "site_grid": 2.53,
      "operations": 12.89,
      "total": 70.98,
      "electricity_usd_2026_kwh": 0.1477,
      "wacc": 0.0727,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.65,
      "electricity": 9.1,
      "site_grid": 6.26,
      "operations": 18.02,
      "total": 122.03,
      "electricity_usd_2026_kwh": 0.1477,
      "wacc": 0.0727,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.94,
      "electricity": 11.69,
      "site_grid": 5.59,
      "operations": 31.23,
      "total": 160.46,
      "electricity_usd_2026_kwh": 0.1477,
      "wacc": 0.0727,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.89,
      "electricity": 1.57,
      "site_grid": 1.38,
      "operations": 3.26,
      "total": 25.09,
      "electricity_usd_2026_kwh": 0.1624,
      "wacc": 0.0782,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.85,
      "electricity": 2.01,
      "site_grid": 1.22,
      "operations": 5.45,
      "total": 32.54,
      "electricity_usd_2026_kwh": 0.1624,
      "wacc": 0.0782,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.47,
      "electricity": 4.25,
      "site_grid": 2.95,
      "operations": 7.56,
      "total": 55.24,
      "electricity_usd_2026_kwh": 0.1624,
      "wacc": 0.0782,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.1,
      "electricity": 5.46,
      "site_grid": 2.62,
      "operations": 12.89,
      "total": 72.08,
      "electricity_usd_2026_kwh": 0.1624,
      "wacc": 0.0782,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.54,
      "electricity": 10.01,
      "site_grid": 6.53,
      "operations": 18.02,
      "total": 124.1,
      "electricity_usd_2026_kwh": 0.1624,
      "wacc": 0.0782,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 113.06,
      "electricity": 12.86,
      "site_grid": 5.8,
      "operations": 31.23,
      "total": 162.95,
      "electricity_usd_2026_kwh": 0.1624,
      "wacc": 0.0782,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.95,
      "electricity": 1.51,
      "site_grid": 1.42,
      "operations": 3.26,
      "total": 25.14,
      "electricity_usd_2026_kwh": 0.1563,
      "wacc": 0.0801,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.93,
      "electricity": 1.94,
      "site_grid": 1.26,
      "operations": 5.45,
      "total": 32.57,
      "electricity_usd_2026_kwh": 0.1563,
      "wacc": 0.0801,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.61,
      "electricity": 4.09,
      "site_grid": 3.04,
      "operations": 7.56,
      "total": 55.3,
      "electricity_usd_2026_kwh": 0.1563,
      "wacc": 0.0801,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.28,
      "electricity": 5.25,
      "site_grid": 2.69,
      "operations": 12.89,
      "total": 72.11,
      "electricity_usd_2026_kwh": 0.1563,
      "wacc": 0.0801,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.85,
      "electricity": 9.63,
      "site_grid": 6.72,
      "operations": 18.02,
      "total": 124.21,
      "electricity_usd_2026_kwh": 0.1563,
      "wacc": 0.0801,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 113.45,
      "electricity": 12.37,
      "site_grid": 5.95,
      "operations": 31.23,
      "total": 163.0,
      "electricity_usd_2026_kwh": 0.1563,
      "wacc": 0.0801,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.82,
      "electricity": 1.22,
      "site_grid": 1.41,
      "operations": 3.26,
      "total": 24.7,
      "electricity_usd_2026_kwh": 0.1263,
      "wacc": 0.0761,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.76,
      "electricity": 1.57,
      "site_grid": 1.25,
      "operations": 5.45,
      "total": 32.03,
      "electricity_usd_2026_kwh": 0.1263,
      "wacc": 0.0761,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.32,
      "electricity": 3.31,
      "site_grid": 3.01,
      "operations": 7.56,
      "total": 54.19,
      "electricity_usd_2026_kwh": 0.1263,
      "wacc": 0.0761,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.91,
      "electricity": 4.25,
      "site_grid": 2.68,
      "operations": 12.89,
      "total": 70.73,
      "electricity_usd_2026_kwh": 0.1263,
      "wacc": 0.0761,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.19,
      "electricity": 7.78,
      "site_grid": 6.67,
      "operations": 18.02,
      "total": 121.66,
      "electricity_usd_2026_kwh": 0.1263,
      "wacc": 0.0761,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.62,
      "electricity": 10.0,
      "site_grid": 5.93,
      "operations": 31.23,
      "total": 159.79,
      "electricity_usd_2026_kwh": 0.1263,
      "wacc": 0.0761,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.71,
      "electricity": 1.13,
      "site_grid": 1.37,
      "operations": 3.26,
      "total": 24.47,
      "electricity_usd_2026_kwh": 0.1167,
      "wacc": 0.0731,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.63,
      "electricity": 1.45,
      "site_grid": 1.22,
      "operations": 5.45,
      "total": 31.75,
      "electricity_usd_2026_kwh": 0.1167,
      "wacc": 0.0731,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.09,
      "electricity": 3.05,
      "site_grid": 2.94,
      "operations": 7.56,
      "total": 53.65,
      "electricity_usd_2026_kwh": 0.1167,
      "wacc": 0.0731,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.63,
      "electricity": 3.92,
      "site_grid": 2.62,
      "operations": 12.89,
      "total": 70.07,
      "electricity_usd_2026_kwh": 0.1167,
      "wacc": 0.0731,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.7,
      "electricity": 7.19,
      "site_grid": 6.5,
      "operations": 18.02,
      "total": 120.41,
      "electricity_usd_2026_kwh": 0.1167,
      "wacc": 0.0731,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.01,
      "electricity": 9.24,
      "site_grid": 5.8,
      "operations": 31.23,
      "total": 158.29,
      "electricity_usd_2026_kwh": 0.1167,
      "wacc": 0.0731,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.88,
      "electricity": 1.14,
      "site_grid": 1.42,
      "operations": 3.26,
      "total": 24.7,
      "electricity_usd_2026_kwh": 0.1185,
      "wacc": 0.078,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.84,
      "electricity": 1.47,
      "site_grid": 1.26,
      "operations": 5.45,
      "total": 32.02,
      "electricity_usd_2026_kwh": 0.1185,
      "wacc": 0.078,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.46,
      "electricity": 3.1,
      "site_grid": 3.04,
      "operations": 7.56,
      "total": 54.16,
      "electricity_usd_2026_kwh": 0.1185,
      "wacc": 0.078,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.08,
      "electricity": 3.98,
      "site_grid": 2.7,
      "operations": 12.89,
      "total": 70.66,
      "electricity_usd_2026_kwh": 0.1185,
      "wacc": 0.078,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.5,
      "electricity": 7.3,
      "site_grid": 6.73,
      "operations": 18.02,
      "total": 121.55,
      "electricity_usd_2026_kwh": 0.1185,
      "wacc": 0.078,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 113.01,
      "electricity": 9.38,
      "site_grid": 5.98,
      "operations": 31.23,
      "total": 159.6,
      "electricity_usd_2026_kwh": 0.1185,
      "wacc": 0.078,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.08,
      "electricity": 1.27,
      "site_grid": 1.51,
      "operations": 3.26,
      "total": 25.12,
      "electricity_usd_2026_kwh": 0.1319,
      "wacc": 0.0838,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.09,
      "electricity": 1.64,
      "site_grid": 1.33,
      "operations": 5.45,
      "total": 32.51,
      "electricity_usd_2026_kwh": 0.1319,
      "wacc": 0.0838,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.89,
      "electricity": 3.45,
      "site_grid": 3.23,
      "operations": 7.56,
      "total": 55.12,
      "electricity_usd_2026_kwh": 0.1319,
      "wacc": 0.0838,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.62,
      "electricity": 4.43,
      "site_grid": 2.85,
      "operations": 12.89,
      "total": 71.8,
      "electricity_usd_2026_kwh": 0.1319,
      "wacc": 0.0838,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.45,
      "electricity": 8.13,
      "site_grid": 7.14,
      "operations": 18.02,
      "total": 123.74,
      "electricity_usd_2026_kwh": 0.1319,
      "wacc": 0.0838,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 114.21,
      "electricity": 10.44,
      "site_grid": 6.3,
      "operations": 31.23,
      "total": 162.18,
      "electricity_usd_2026_kwh": 0.1319,
      "wacc": 0.0838,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.82,
      "electricity": 1.39,
      "site_grid": 1.49,
      "operations": 3.26,
      "total": 24.95,
      "electricity_usd_2026_kwh": 0.1438,
      "wacc": 0.0761,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.76,
      "electricity": 1.78,
      "site_grid": 1.33,
      "operations": 5.45,
      "total": 32.32,
      "electricity_usd_2026_kwh": 0.1438,
      "wacc": 0.0761,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.32,
      "electricity": 3.76,
      "site_grid": 3.2,
      "operations": 7.56,
      "total": 54.84,
      "electricity_usd_2026_kwh": 0.1438,
      "wacc": 0.0761,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.91,
      "electricity": 4.83,
      "site_grid": 2.85,
      "operations": 12.89,
      "total": 71.48,
      "electricity_usd_2026_kwh": 0.1438,
      "wacc": 0.0761,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.2,
      "electricity": 8.86,
      "site_grid": 7.08,
      "operations": 18.02,
      "total": 123.15,
      "electricity_usd_2026_kwh": 0.1438,
      "wacc": 0.0761,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.63,
      "electricity": 11.38,
      "site_grid": 6.3,
      "operations": 31.23,
      "total": 161.54,
      "electricity_usd_2026_kwh": 0.1438,
      "wacc": 0.0761,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.39,
      "electricity": 1.47,
      "site_grid": 1.4,
      "operations": 3.26,
      "total": 24.51,
      "electricity_usd_2026_kwh": 0.1518,
      "wacc": 0.0636,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.22,
      "electricity": 1.88,
      "site_grid": 1.26,
      "operations": 5.45,
      "total": 31.82,
      "electricity_usd_2026_kwh": 0.1518,
      "wacc": 0.0636,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.4,
      "electricity": 3.97,
      "site_grid": 3.0,
      "operations": 7.56,
      "total": 53.93,
      "electricity_usd_2026_kwh": 0.1518,
      "wacc": 0.0636,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.76,
      "electricity": 5.1,
      "site_grid": 2.71,
      "operations": 12.89,
      "total": 70.46,
      "electricity_usd_2026_kwh": 0.1518,
      "wacc": 0.0636,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.17,
      "electricity": 9.35,
      "site_grid": 6.63,
      "operations": 18.02,
      "total": 121.17,
      "electricity_usd_2026_kwh": 0.1518,
      "wacc": 0.0636,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.08,
      "electricity": 12.02,
      "site_grid": 5.99,
      "operations": 31.23,
      "total": 159.32,
      "electricity_usd_2026_kwh": 0.1518,
      "wacc": 0.0636,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.58,
      "electricity": 1.59,
      "site_grid": 1.46,
      "operations": 3.26,
      "total": 24.89,
      "electricity_usd_2026_kwh": 0.1649,
      "wacc": 0.0692,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.46,
      "electricity": 2.04,
      "site_grid": 1.31,
      "operations": 5.45,
      "total": 32.26,
      "electricity_usd_2026_kwh": 0.1649,
      "wacc": 0.0692,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.81,
      "electricity": 4.31,
      "site_grid": 3.13,
      "operations": 7.56,
      "total": 54.81,
      "electricity_usd_2026_kwh": 0.1649,
      "wacc": 0.0692,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.27,
      "electricity": 5.54,
      "site_grid": 2.8,
      "operations": 12.89,
      "total": 71.51,
      "electricity_usd_2026_kwh": 0.1649,
      "wacc": 0.0692,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.07,
      "electricity": 10.16,
      "site_grid": 6.92,
      "operations": 18.02,
      "total": 123.16,
      "electricity_usd_2026_kwh": 0.1649,
      "wacc": 0.0692,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.22,
      "electricity": 13.05,
      "site_grid": 6.2,
      "operations": 31.23,
      "total": 161.7,
      "electricity_usd_2026_kwh": 0.1649,
      "wacc": 0.0692,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.1,
      "electricity": 3.4,
      "site_grid": 1.82,
      "operations": 3.26,
      "total": 27.57,
      "electricity_usd_2026_kwh": 0.3521,
      "wacc": 0.0842,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.11,
      "electricity": 4.36,
      "site_grid": 1.6,
      "operations": 5.45,
      "total": 35.53,
      "electricity_usd_2026_kwh": 0.3521,
      "wacc": 0.0842,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.91,
      "electricity": 9.21,
      "site_grid": 3.9,
      "operations": 7.56,
      "total": 61.58,
      "electricity_usd_2026_kwh": 0.3521,
      "wacc": 0.0842,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.66,
      "electricity": 11.83,
      "site_grid": 3.44,
      "operations": 12.89,
      "total": 79.82,
      "electricity_usd_2026_kwh": 0.3521,
      "wacc": 0.0842,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 90.52,
      "electricity": 21.69,
      "site_grid": 8.62,
      "operations": 18.02,
      "total": 138.85,
      "electricity_usd_2026_kwh": 0.3521,
      "wacc": 0.0842,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 114.29,
      "electricity": 27.87,
      "site_grid": 7.6,
      "operations": 31.23,
      "total": 180.99,
      "electricity_usd_2026_kwh": 0.3521,
      "wacc": 0.0842,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.45,
      "electricity": 1.98,
      "site_grid": 2.0,
      "operations": 3.26,
      "total": 26.68,
      "electricity_usd_2026_kwh": 0.2054,
      "wacc": 0.0943,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.55,
      "electricity": 2.55,
      "site_grid": 1.74,
      "operations": 5.45,
      "total": 34.29,
      "electricity_usd_2026_kwh": 0.2054,
      "wacc": 0.0943,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.66,
      "electricity": 5.37,
      "site_grid": 4.28,
      "operations": 7.56,
      "total": 58.87,
      "electricity_usd_2026_kwh": 0.2054,
      "wacc": 0.0943,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.6,
      "electricity": 6.9,
      "site_grid": 3.73,
      "operations": 12.89,
      "total": 76.13,
      "electricity_usd_2026_kwh": 0.2054,
      "wacc": 0.0943,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 92.17,
      "electricity": 12.65,
      "site_grid": 9.47,
      "operations": 18.02,
      "total": 132.31,
      "electricity_usd_2026_kwh": 0.2054,
      "wacc": 0.0943,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 116.36,
      "electricity": 16.25,
      "site_grid": 8.26,
      "operations": 31.23,
      "total": 172.11,
      "electricity_usd_2026_kwh": 0.2054,
      "wacc": 0.0943,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.53,
      "electricity": 1.8,
      "site_grid": 1.96,
      "operations": 3.26,
      "total": 26.55,
      "electricity_usd_2026_kwh": 0.1863,
      "wacc": 0.0968,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.66,
      "electricity": 2.31,
      "site_grid": 1.71,
      "operations": 5.45,
      "total": 34.12,
      "electricity_usd_2026_kwh": 0.1863,
      "wacc": 0.0968,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.85,
      "electricity": 4.87,
      "site_grid": 4.21,
      "operations": 7.56,
      "total": 58.49,
      "electricity_usd_2026_kwh": 0.1863,
      "wacc": 0.0968,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.83,
      "electricity": 6.26,
      "site_grid": 3.66,
      "operations": 12.89,
      "total": 75.65,
      "electricity_usd_2026_kwh": 0.1863,
      "wacc": 0.0968,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 92.58,
      "electricity": 11.48,
      "site_grid": 9.3,
      "operations": 18.02,
      "total": 131.38,
      "electricity_usd_2026_kwh": 0.1863,
      "wacc": 0.0968,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 116.88,
      "electricity": 14.75,
      "site_grid": 8.1,
      "operations": 31.23,
      "total": 170.95,
      "electricity_usd_2026_kwh": 0.1863,
      "wacc": 0.0968,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.56,
      "electricity": 2.02,
      "site_grid": 1.95,
      "operations": 3.26,
      "total": 26.78,
      "electricity_usd_2026_kwh": 0.2092,
      "wacc": 0.0976,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.69,
      "electricity": 2.59,
      "site_grid": 1.69,
      "operations": 5.45,
      "total": 34.43,
      "electricity_usd_2026_kwh": 0.2092,
      "wacc": 0.0976,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.91,
      "electricity": 5.47,
      "site_grid": 4.17,
      "operations": 7.56,
      "total": 59.12,
      "electricity_usd_2026_kwh": 0.2092,
      "wacc": 0.0976,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.91,
      "electricity": 7.03,
      "site_grid": 3.63,
      "operations": 12.89,
      "total": 76.46,
      "electricity_usd_2026_kwh": 0.2092,
      "wacc": 0.0976,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 92.72,
      "electricity": 12.89,
      "site_grid": 9.23,
      "operations": 18.02,
      "total": 132.86,
      "electricity_usd_2026_kwh": 0.2092,
      "wacc": 0.0976,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 117.05,
      "electricity": 16.56,
      "site_grid": 8.03,
      "operations": 31.23,
      "total": 172.87,
      "electricity_usd_2026_kwh": 0.2092,
      "wacc": 0.0976,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.57,
      "electricity": 2.09,
      "site_grid": 1.96,
      "operations": 3.26,
      "total": 26.88,
      "electricity_usd_2026_kwh": 0.2164,
      "wacc": 0.098,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.71,
      "electricity": 2.68,
      "site_grid": 1.7,
      "operations": 5.45,
      "total": 34.54,
      "electricity_usd_2026_kwh": 0.2164,
      "wacc": 0.098,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.94,
      "electricity": 5.66,
      "site_grid": 4.19,
      "operations": 7.56,
      "total": 59.35,
      "electricity_usd_2026_kwh": 0.2164,
      "wacc": 0.098,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.94,
      "electricity": 7.27,
      "site_grid": 3.64,
      "operations": 12.89,
      "total": 76.76,
      "electricity_usd_2026_kwh": 0.2164,
      "wacc": 0.098,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 92.78,
      "electricity": 13.33,
      "site_grid": 9.28,
      "operations": 18.02,
      "total": 133.41,
      "electricity_usd_2026_kwh": 0.2164,
      "wacc": 0.098,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 117.13,
      "electricity": 17.13,
      "site_grid": 8.06,
      "operations": 31.23,
      "total": 173.56,
      "electricity_usd_2026_kwh": 0.2164,
      "wacc": 0.098,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.37,
      "electricity": 2.26,
      "site_grid": 1.37,
      "operations": 3.24,
      "total": 25.24,
      "electricity_usd_2026_kwh": 0.2384,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.16,
      "electricity": 2.9,
      "site_grid": 1.24,
      "operations": 5.65,
      "total": 32.94,
      "electricity_usd_2026_kwh": 0.2384,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.36,
      "electricity": 6.12,
      "site_grid": 2.93,
      "operations": 7.53,
      "total": 55.94,
      "electricity_usd_2026_kwh": 0.2384,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.61,
      "electricity": 7.85,
      "site_grid": 2.65,
      "operations": 13.33,
      "total": 73.44,
      "electricity_usd_2026_kwh": 0.2384,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.08,
      "electricity": 14.41,
      "site_grid": 6.48,
      "operations": 17.96,
      "total": 125.93,
      "electricity_usd_2026_kwh": 0.2384,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.76,
      "electricity": 18.49,
      "site_grid": 5.86,
      "operations": 32.19,
      "total": 166.3,
      "electricity_usd_2026_kwh": 0.2384,
      "wacc": 0.0738,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.23,
      "electricity": 2.46,
      "site_grid": 1.31,
      "operations": 3.24,
      "total": 25.24,
      "electricity_usd_2026_kwh": 0.2595,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.97,
      "electricity": 3.15,
      "site_grid": 1.19,
      "operations": 5.65,
      "total": 32.97,
      "electricity_usd_2026_kwh": 0.2595,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.05,
      "electricity": 6.66,
      "site_grid": 2.81,
      "operations": 7.53,
      "total": 56.05,
      "electricity_usd_2026_kwh": 0.2595,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.22,
      "electricity": 8.54,
      "site_grid": 2.55,
      "operations": 13.33,
      "total": 73.65,
      "electricity_usd_2026_kwh": 0.2595,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.39,
      "electricity": 15.69,
      "site_grid": 6.22,
      "operations": 17.96,
      "total": 126.25,
      "electricity_usd_2026_kwh": 0.2595,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.9,
      "electricity": 20.12,
      "site_grid": 5.65,
      "operations": 32.19,
      "total": 166.86,
      "electricity_usd_2026_kwh": 0.2595,
      "wacc": 0.0695,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.9,
      "electricity": 2.27,
      "site_grid": 1.24,
      "operations": 3.24,
      "total": 24.64,
      "electricity_usd_2026_kwh": 0.2393,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.56,
      "electricity": 2.91,
      "site_grid": 1.14,
      "operations": 5.65,
      "total": 32.26,
      "electricity_usd_2026_kwh": 0.2393,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.35,
      "electricity": 6.14,
      "site_grid": 2.65,
      "operations": 7.53,
      "total": 54.67,
      "electricity_usd_2026_kwh": 0.2393,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.34,
      "electricity": 7.88,
      "site_grid": 2.43,
      "operations": 13.33,
      "total": 71.99,
      "electricity_usd_2026_kwh": 0.2393,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.84,
      "electricity": 14.47,
      "site_grid": 5.86,
      "operations": 17.96,
      "total": 123.12,
      "electricity_usd_2026_kwh": 0.2393,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.95,
      "electricity": 18.56,
      "site_grid": 5.39,
      "operations": 32.19,
      "total": 163.09,
      "electricity_usd_2026_kwh": 0.2393,
      "wacc": 0.0597,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.08,
      "electricity": 2.28,
      "site_grid": 1.29,
      "operations": 3.24,
      "total": 24.9,
      "electricity_usd_2026_kwh": 0.2407,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.79,
      "electricity": 2.92,
      "site_grid": 1.18,
      "operations": 5.65,
      "total": 32.55,
      "electricity_usd_2026_kwh": 0.2407,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.74,
      "electricity": 6.18,
      "site_grid": 2.77,
      "operations": 7.53,
      "total": 55.22,
      "electricity_usd_2026_kwh": 0.2407,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.83,
      "electricity": 7.93,
      "site_grid": 2.53,
      "operations": 13.33,
      "total": 72.62,
      "electricity_usd_2026_kwh": 0.2407,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.7,
      "electricity": 14.55,
      "site_grid": 6.13,
      "operations": 17.96,
      "total": 124.34,
      "electricity_usd_2026_kwh": 0.2407,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.04,
      "electricity": 18.67,
      "site_grid": 5.6,
      "operations": 32.19,
      "total": 164.49,
      "electricity_usd_2026_kwh": 0.2407,
      "wacc": 0.0652,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.14,
      "electricity": 2.04,
      "site_grid": 1.33,
      "operations": 3.24,
      "total": 24.76,
      "electricity_usd_2026_kwh": 0.2158,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.87,
      "electricity": 2.62,
      "site_grid": 1.21,
      "operations": 5.65,
      "total": 32.36,
      "electricity_usd_2026_kwh": 0.2158,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.88,
      "electricity": 5.54,
      "site_grid": 2.85,
      "operations": 7.53,
      "total": 54.8,
      "electricity_usd_2026_kwh": 0.2158,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.0,
      "electricity": 7.11,
      "site_grid": 2.6,
      "operations": 13.33,
      "total": 72.04,
      "electricity_usd_2026_kwh": 0.2158,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.01,
      "electricity": 13.05,
      "site_grid": 6.3,
      "operations": 17.96,
      "total": 123.31,
      "electricity_usd_2026_kwh": 0.2158,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.41,
      "electricity": 16.74,
      "site_grid": 5.74,
      "operations": 32.19,
      "total": 163.09,
      "electricity_usd_2026_kwh": 0.2158,
      "wacc": 0.0671,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.01,
      "electricity": 1.65,
      "site_grid": 1.32,
      "operations": 3.24,
      "total": 24.22,
      "electricity_usd_2026_kwh": 0.174,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.7,
      "electricity": 2.11,
      "site_grid": 1.21,
      "operations": 5.65,
      "total": 31.68,
      "electricity_usd_2026_kwh": 0.174,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.59,
      "electricity": 4.47,
      "site_grid": 2.82,
      "operations": 7.53,
      "total": 53.41,
      "electricity_usd_2026_kwh": 0.174,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.64,
      "electricity": 5.73,
      "site_grid": 2.59,
      "operations": 13.33,
      "total": 70.29,
      "electricity_usd_2026_kwh": 0.174,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.37,
      "electricity": 10.52,
      "site_grid": 6.25,
      "operations": 17.96,
      "total": 120.09,
      "electricity_usd_2026_kwh": 0.174,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.62,
      "electricity": 13.49,
      "site_grid": 5.72,
      "operations": 32.19,
      "total": 159.02,
      "electricity_usd_2026_kwh": 0.174,
      "wacc": 0.0631,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.91,
      "electricity": 1.59,
      "site_grid": 1.28,
      "operations": 3.24,
      "total": 24.03,
      "electricity_usd_2026_kwh": 0.168,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.58,
      "electricity": 2.04,
      "site_grid": 1.18,
      "operations": 5.65,
      "total": 31.45,
      "electricity_usd_2026_kwh": 0.168,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.37,
      "electricity": 4.31,
      "site_grid": 2.75,
      "operations": 7.53,
      "total": 52.97,
      "electricity_usd_2026_kwh": 0.168,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.37,
      "electricity": 5.53,
      "site_grid": 2.53,
      "operations": 13.33,
      "total": 69.77,
      "electricity_usd_2026_kwh": 0.168,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.89,
      "electricity": 10.16,
      "site_grid": 6.08,
      "operations": 17.96,
      "total": 119.09,
      "electricity_usd_2026_kwh": 0.168,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.02,
      "electricity": 13.03,
      "site_grid": 5.59,
      "operations": 32.19,
      "total": 157.83,
      "electricity_usd_2026_kwh": 0.168,
      "wacc": 0.0601,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.07,
      "electricity": 1.61,
      "site_grid": 1.33,
      "operations": 3.24,
      "total": 24.26,
      "electricity_usd_2026_kwh": 0.17,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.78,
      "electricity": 2.06,
      "site_grid": 1.22,
      "operations": 5.65,
      "total": 31.72,
      "electricity_usd_2026_kwh": 0.17,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.72,
      "electricity": 4.36,
      "site_grid": 2.85,
      "operations": 7.53,
      "total": 53.47,
      "electricity_usd_2026_kwh": 0.17,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.81,
      "electricity": 5.6,
      "site_grid": 2.61,
      "operations": 13.33,
      "total": 70.35,
      "electricity_usd_2026_kwh": 0.17,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.67,
      "electricity": 10.28,
      "site_grid": 6.31,
      "operations": 17.96,
      "total": 120.21,
      "electricity_usd_2026_kwh": 0.17,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.0,
      "electricity": 13.18,
      "site_grid": 5.77,
      "operations": 32.19,
      "total": 159.13,
      "electricity_usd_2026_kwh": 0.17,
      "wacc": 0.065,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.27,
      "electricity": 1.74,
      "site_grid": 1.41,
      "operations": 3.24,
      "total": 24.67,
      "electricity_usd_2026_kwh": 0.184,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.03,
      "electricity": 2.23,
      "site_grid": 1.28,
      "operations": 5.65,
      "total": 32.2,
      "electricity_usd_2026_kwh": 0.184,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.14,
      "electricity": 4.72,
      "site_grid": 3.03,
      "operations": 7.53,
      "total": 54.43,
      "electricity_usd_2026_kwh": 0.184,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.34,
      "electricity": 6.06,
      "site_grid": 2.75,
      "operations": 13.33,
      "total": 71.48,
      "electricity_usd_2026_kwh": 0.184,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.6,
      "electricity": 11.12,
      "site_grid": 6.7,
      "operations": 17.96,
      "total": 122.38,
      "electricity_usd_2026_kwh": 0.184,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.15,
      "electricity": 14.27,
      "site_grid": 6.08,
      "operations": 32.19,
      "total": 161.7,
      "electricity_usd_2026_kwh": 0.184,
      "wacc": 0.0708,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.01,
      "electricity": 1.78,
      "site_grid": 1.4,
      "operations": 3.24,
      "total": 24.44,
      "electricity_usd_2026_kwh": 0.1885,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.7,
      "electricity": 2.29,
      "site_grid": 1.28,
      "operations": 5.65,
      "total": 31.93,
      "electricity_usd_2026_kwh": 0.1885,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.59,
      "electricity": 4.84,
      "site_grid": 3.0,
      "operations": 7.53,
      "total": 53.96,
      "electricity_usd_2026_kwh": 0.1885,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.65,
      "electricity": 6.21,
      "site_grid": 2.74,
      "operations": 13.33,
      "total": 70.93,
      "electricity_usd_2026_kwh": 0.1885,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.37,
      "electricity": 11.39,
      "site_grid": 6.63,
      "operations": 17.96,
      "total": 121.35,
      "electricity_usd_2026_kwh": 0.1885,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.62,
      "electricity": 14.62,
      "site_grid": 6.07,
      "operations": 32.19,
      "total": 160.5,
      "electricity_usd_2026_kwh": 0.1885,
      "wacc": 0.0631,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.59,
      "electricity": 1.82,
      "site_grid": 1.31,
      "operations": 3.24,
      "total": 23.96,
      "electricity_usd_2026_kwh": 0.1923,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.18,
      "electricity": 2.34,
      "site_grid": 1.22,
      "operations": 5.65,
      "total": 31.39,
      "electricity_usd_2026_kwh": 0.1923,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.7,
      "electricity": 4.94,
      "site_grid": 2.8,
      "operations": 7.53,
      "total": 52.96,
      "electricity_usd_2026_kwh": 0.1923,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.53,
      "electricity": 6.33,
      "site_grid": 2.6,
      "operations": 13.33,
      "total": 69.79,
      "electricity_usd_2026_kwh": 0.1923,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.4,
      "electricity": 11.62,
      "site_grid": 6.19,
      "operations": 17.96,
      "total": 119.17,
      "electricity_usd_2026_kwh": 0.1923,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.15,
      "electricity": 14.91,
      "site_grid": 5.76,
      "operations": 32.19,
      "total": 158.01,
      "electricity_usd_2026_kwh": 0.1923,
      "wacc": 0.0506,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.78,
      "electricity": 1.79,
      "site_grid": 1.36,
      "operations": 3.24,
      "total": 24.18,
      "electricity_usd_2026_kwh": 0.189,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.42,
      "electricity": 2.3,
      "site_grid": 1.26,
      "operations": 5.65,
      "total": 31.62,
      "electricity_usd_2026_kwh": 0.189,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.09,
      "electricity": 4.85,
      "site_grid": 2.92,
      "operations": 7.53,
      "total": 53.4,
      "electricity_usd_2026_kwh": 0.189,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.03,
      "electricity": 6.23,
      "site_grid": 2.7,
      "operations": 13.33,
      "total": 70.28,
      "electricity_usd_2026_kwh": 0.189,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.28,
      "electricity": 11.43,
      "site_grid": 6.47,
      "operations": 17.96,
      "total": 120.13,
      "electricity_usd_2026_kwh": 0.189,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.25,
      "electricity": 14.66,
      "site_grid": 5.97,
      "operations": 32.19,
      "total": 159.07,
      "electricity_usd_2026_kwh": 0.189,
      "wacc": 0.0562,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.28,
      "electricity": 2.58,
      "site_grid": 1.71,
      "operations": 3.24,
      "total": 25.82,
      "electricity_usd_2026_kwh": 0.2729,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.04,
      "electricity": 3.32,
      "site_grid": 1.55,
      "operations": 5.65,
      "total": 33.56,
      "electricity_usd_2026_kwh": 0.2729,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.17,
      "electricity": 7.01,
      "site_grid": 3.66,
      "operations": 7.53,
      "total": 57.37,
      "electricity_usd_2026_kwh": 0.2729,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.37,
      "electricity": 8.99,
      "site_grid": 3.32,
      "operations": 13.33,
      "total": 75.01,
      "electricity_usd_2026_kwh": 0.2729,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.66,
      "electricity": 16.5,
      "site_grid": 8.09,
      "operations": 17.96,
      "total": 129.21,
      "electricity_usd_2026_kwh": 0.2729,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.23,
      "electricity": 21.17,
      "site_grid": 7.34,
      "operations": 32.19,
      "total": 169.93,
      "electricity_usd_2026_kwh": 0.2729,
      "wacc": 0.0712,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.62,
      "electricity": 2.79,
      "site_grid": 1.88,
      "operations": 3.24,
      "total": 26.53,
      "electricity_usd_2026_kwh": 0.2944,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.47,
      "electricity": 3.58,
      "site_grid": 1.69,
      "operations": 5.65,
      "total": 34.39,
      "electricity_usd_2026_kwh": 0.2944,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.9,
      "electricity": 7.56,
      "site_grid": 4.03,
      "operations": 7.53,
      "total": 59.02,
      "electricity_usd_2026_kwh": 0.2944,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.28,
      "electricity": 9.7,
      "site_grid": 3.61,
      "operations": 13.33,
      "total": 76.92,
      "electricity_usd_2026_kwh": 0.2944,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.27,
      "electricity": 17.8,
      "site_grid": 8.92,
      "operations": 17.96,
      "total": 132.94,
      "electricity_usd_2026_kwh": 0.2944,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.25,
      "electricity": 22.83,
      "site_grid": 7.99,
      "operations": 32.19,
      "total": 174.27,
      "electricity_usd_2026_kwh": 0.2944,
      "wacc": 0.0813,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.71,
      "electricity": 2.13,
      "site_grid": 1.85,
      "operations": 3.24,
      "total": 25.93,
      "electricity_usd_2026_kwh": 0.2248,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.58,
      "electricity": 2.73,
      "site_grid": 1.65,
      "operations": 5.65,
      "total": 33.61,
      "electricity_usd_2026_kwh": 0.2248,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.08,
      "electricity": 5.77,
      "site_grid": 3.96,
      "operations": 7.53,
      "total": 57.35,
      "electricity_usd_2026_kwh": 0.2248,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.51,
      "electricity": 7.4,
      "site_grid": 3.54,
      "operations": 13.33,
      "total": 74.79,
      "electricity_usd_2026_kwh": 0.2248,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.67,
      "electricity": 13.59,
      "site_grid": 8.77,
      "operations": 17.96,
      "total": 128.98,
      "electricity_usd_2026_kwh": 0.2248,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.75,
      "electricity": 17.44,
      "site_grid": 7.84,
      "operations": 32.19,
      "total": 169.21,
      "electricity_usd_2026_kwh": 0.2248,
      "wacc": 0.0838,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.73,
      "electricity": 2.23,
      "site_grid": 1.84,
      "operations": 3.24,
      "total": 26.04,
      "electricity_usd_2026_kwh": 0.2353,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.61,
      "electricity": 2.86,
      "site_grid": 1.64,
      "operations": 5.65,
      "total": 33.76,
      "electricity_usd_2026_kwh": 0.2353,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.14,
      "electricity": 6.04,
      "site_grid": 3.93,
      "operations": 7.53,
      "total": 57.65,
      "electricity_usd_2026_kwh": 0.2353,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.59,
      "electricity": 7.75,
      "site_grid": 3.51,
      "operations": 13.33,
      "total": 75.18,
      "electricity_usd_2026_kwh": 0.2353,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.8,
      "electricity": 14.23,
      "site_grid": 8.7,
      "operations": 17.96,
      "total": 129.69,
      "electricity_usd_2026_kwh": 0.2353,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.92,
      "electricity": 18.25,
      "site_grid": 7.77,
      "operations": 32.19,
      "total": 170.13,
      "electricity_usd_2026_kwh": 0.2353,
      "wacc": 0.0846,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.75,
      "electricity": 2.27,
      "site_grid": 1.85,
      "operations": 3.24,
      "total": 26.11,
      "electricity_usd_2026_kwh": 0.2397,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.63,
      "electricity": 2.91,
      "site_grid": 1.65,
      "operations": 5.65,
      "total": 33.84,
      "electricity_usd_2026_kwh": 0.2397,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.17,
      "electricity": 6.15,
      "site_grid": 3.95,
      "operations": 7.53,
      "total": 57.8,
      "electricity_usd_2026_kwh": 0.2397,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.62,
      "electricity": 7.89,
      "site_grid": 3.53,
      "operations": 13.33,
      "total": 75.37,
      "electricity_usd_2026_kwh": 0.2397,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.86,
      "electricity": 14.49,
      "site_grid": 8.75,
      "operations": 17.96,
      "total": 130.05,
      "electricity_usd_2026_kwh": 0.2397,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.99,
      "electricity": 18.59,
      "site_grid": 7.81,
      "operations": 32.19,
      "total": 170.58,
      "electricity_usd_2026_kwh": 0.2397,
      "wacc": 0.085,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.96,
      "electricity": 1.9,
      "site_grid": 1.33,
      "operations": 3.26,
      "total": 24.45,
      "electricity_usd_2026_kwh": 0.2008,
      "wacc": 0.0668,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.62,
      "electricity": 2.44,
      "site_grid": 1.22,
      "operations": 5.84,
      "total": 32.12,
      "electricity_usd_2026_kwh": 0.2008,
      "wacc": 0.0668,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.48,
      "electricity": 5.15,
      "site_grid": 2.85,
      "operations": 7.56,
      "total": 54.04,
      "electricity_usd_2026_kwh": 0.2008,
      "wacc": 0.0668,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.47,
      "electricity": 6.61,
      "site_grid": 2.61,
      "operations": 13.74,
      "total": 71.42,
      "electricity_usd_2026_kwh": 0.2008,
      "wacc": 0.0668,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.12,
      "electricity": 12.13,
      "site_grid": 6.31,
      "operations": 18.02,
      "total": 121.58,
      "electricity_usd_2026_kwh": 0.2008,
      "wacc": 0.0668,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.23,
      "electricity": 15.56,
      "site_grid": 5.77,
      "operations": 33.09,
      "total": 161.65,
      "electricity_usd_2026_kwh": 0.2008,
      "wacc": 0.0668,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.81,
      "electricity": 1.89,
      "site_grid": 1.28,
      "operations": 3.26,
      "total": 24.24,
      "electricity_usd_2026_kwh": 0.1996,
      "wacc": 0.0625,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.44,
      "electricity": 2.42,
      "site_grid": 1.17,
      "operations": 5.84,
      "total": 31.88,
      "electricity_usd_2026_kwh": 0.1996,
      "wacc": 0.0625,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.17,
      "electricity": 5.12,
      "site_grid": 2.73,
      "operations": 7.56,
      "total": 53.58,
      "electricity_usd_2026_kwh": 0.1996,
      "wacc": 0.0625,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.09,
      "electricity": 6.56,
      "site_grid": 2.51,
      "operations": 13.74,
      "total": 70.9,
      "electricity_usd_2026_kwh": 0.1996,
      "wacc": 0.0625,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.44,
      "electricity": 12.06,
      "site_grid": 6.05,
      "operations": 18.02,
      "total": 120.57,
      "electricity_usd_2026_kwh": 0.1996,
      "wacc": 0.0625,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.38,
      "electricity": 15.46,
      "site_grid": 5.56,
      "operations": 33.09,
      "total": 160.5,
      "electricity_usd_2026_kwh": 0.1996,
      "wacc": 0.0625,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.49,
      "electricity": 1.65,
      "site_grid": 1.2,
      "operations": 3.26,
      "total": 23.6,
      "electricity_usd_2026_kwh": 0.1747,
      "wacc": 0.0527,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.04,
      "electricity": 2.12,
      "site_grid": 1.12,
      "operations": 5.84,
      "total": 31.12,
      "electricity_usd_2026_kwh": 0.1747,
      "wacc": 0.0527,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.48,
      "electricity": 4.48,
      "site_grid": 2.57,
      "operations": 7.56,
      "total": 52.09,
      "electricity_usd_2026_kwh": 0.1747,
      "wacc": 0.0527,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.22,
      "electricity": 5.75,
      "site_grid": 2.39,
      "operations": 13.74,
      "total": 69.1,
      "electricity_usd_2026_kwh": 0.1747,
      "wacc": 0.0527,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.91,
      "electricity": 10.56,
      "site_grid": 5.69,
      "operations": 18.02,
      "total": 117.18,
      "electricity_usd_2026_kwh": 0.1747,
      "wacc": 0.0527,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.47,
      "electricity": 13.54,
      "site_grid": 5.3,
      "operations": 33.09,
      "total": 156.39,
      "electricity_usd_2026_kwh": 0.1747,
      "wacc": 0.0527,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.67,
      "electricity": 1.71,
      "site_grid": 1.26,
      "operations": 3.26,
      "total": 23.89,
      "electricity_usd_2026_kwh": 0.1801,
      "wacc": 0.0582,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.27,
      "electricity": 2.19,
      "site_grid": 1.16,
      "operations": 5.84,
      "total": 31.46,
      "electricity_usd_2026_kwh": 0.1801,
      "wacc": 0.0582,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.86,
      "electricity": 4.62,
      "site_grid": 2.69,
      "operations": 7.56,
      "total": 52.74,
      "electricity_usd_2026_kwh": 0.1801,
      "wacc": 0.0582,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.7,
      "electricity": 5.93,
      "site_grid": 2.49,
      "operations": 13.74,
      "total": 69.86,
      "electricity_usd_2026_kwh": 0.1801,
      "wacc": 0.0582,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.77,
      "electricity": 10.89,
      "site_grid": 5.96,
      "operations": 18.02,
      "total": 118.63,
      "electricity_usd_2026_kwh": 0.1801,
      "wacc": 0.0582,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.54,
      "electricity": 13.96,
      "site_grid": 5.51,
      "operations": 33.09,
      "total": 158.09,
      "electricity_usd_2026_kwh": 0.1801,
      "wacc": 0.0582,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.73,
      "electricity": 1.5,
      "site_grid": 1.29,
      "operations": 3.26,
      "total": 23.79,
      "electricity_usd_2026_kwh": 0.159,
      "wacc": 0.0601,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.34,
      "electricity": 1.93,
      "site_grid": 1.19,
      "operations": 5.84,
      "total": 31.31,
      "electricity_usd_2026_kwh": 0.159,
      "wacc": 0.0601,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.0,
      "electricity": 4.08,
      "site_grid": 2.77,
      "operations": 7.56,
      "total": 52.41,
      "electricity_usd_2026_kwh": 0.159,
      "wacc": 0.0601,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.87,
      "electricity": 5.23,
      "site_grid": 2.55,
      "operations": 13.74,
      "total": 69.39,
      "electricity_usd_2026_kwh": 0.159,
      "wacc": 0.0601,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.06,
      "electricity": 9.61,
      "site_grid": 6.13,
      "operations": 18.02,
      "total": 117.81,
      "electricity_usd_2026_kwh": 0.159,
      "wacc": 0.0601,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.91,
      "electricity": 12.31,
      "site_grid": 5.65,
      "operations": 33.09,
      "total": 156.97,
      "electricity_usd_2026_kwh": 0.159,
      "wacc": 0.0601,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.6,
      "electricity": 1.24,
      "site_grid": 1.28,
      "operations": 3.26,
      "total": 23.38,
      "electricity_usd_2026_kwh": 0.1314,
      "wacc": 0.0561,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.18,
      "electricity": 1.59,
      "site_grid": 1.19,
      "operations": 5.84,
      "total": 30.8,
      "electricity_usd_2026_kwh": 0.1314,
      "wacc": 0.0561,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.71,
      "electricity": 3.37,
      "site_grid": 2.74,
      "operations": 7.56,
      "total": 51.39,
      "electricity_usd_2026_kwh": 0.1314,
      "wacc": 0.0561,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.52,
      "electricity": 4.32,
      "site_grid": 2.54,
      "operations": 13.74,
      "total": 68.12,
      "electricity_usd_2026_kwh": 0.1314,
      "wacc": 0.0561,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.43,
      "electricity": 7.94,
      "site_grid": 6.07,
      "operations": 18.02,
      "total": 115.46,
      "electricity_usd_2026_kwh": 0.1314,
      "wacc": 0.0561,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.12,
      "electricity": 10.18,
      "site_grid": 5.63,
      "operations": 33.09,
      "total": 154.02,
      "electricity_usd_2026_kwh": 0.1314,
      "wacc": 0.0561,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.5,
      "electricity": 1.21,
      "site_grid": 1.25,
      "operations": 3.26,
      "total": 23.22,
      "electricity_usd_2026_kwh": 0.128,
      "wacc": 0.0531,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.05,
      "electricity": 1.55,
      "site_grid": 1.16,
      "operations": 5.84,
      "total": 30.61,
      "electricity_usd_2026_kwh": 0.128,
      "wacc": 0.0531,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.5,
      "electricity": 3.28,
      "site_grid": 2.67,
      "operations": 7.56,
      "total": 51.02,
      "electricity_usd_2026_kwh": 0.128,
      "wacc": 0.0531,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.25,
      "electricity": 4.21,
      "site_grid": 2.49,
      "operations": 13.74,
      "total": 67.69,
      "electricity_usd_2026_kwh": 0.128,
      "wacc": 0.0531,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.96,
      "electricity": 7.73,
      "site_grid": 5.91,
      "operations": 18.02,
      "total": 114.63,
      "electricity_usd_2026_kwh": 0.128,
      "wacc": 0.0531,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.53,
      "electricity": 9.92,
      "site_grid": 5.5,
      "operations": 33.09,
      "total": 153.04,
      "electricity_usd_2026_kwh": 0.128,
      "wacc": 0.0531,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.67,
      "electricity": 1.13,
      "site_grid": 1.29,
      "operations": 3.26,
      "total": 23.35,
      "electricity_usd_2026_kwh": 0.1195,
      "wacc": 0.058,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.26,
      "electricity": 1.45,
      "site_grid": 1.2,
      "operations": 5.84,
      "total": 30.75,
      "electricity_usd_2026_kwh": 0.1195,
      "wacc": 0.058,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.85,
      "electricity": 3.07,
      "site_grid": 2.77,
      "operations": 7.56,
      "total": 51.25,
      "electricity_usd_2026_kwh": 0.1195,
      "wacc": 0.058,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.68,
      "electricity": 3.93,
      "site_grid": 2.56,
      "operations": 13.74,
      "total": 67.92,
      "electricity_usd_2026_kwh": 0.1195,
      "wacc": 0.058,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.73,
      "electricity": 7.22,
      "site_grid": 6.13,
      "operations": 18.02,
      "total": 115.1,
      "electricity_usd_2026_kwh": 0.1195,
      "wacc": 0.058,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.5,
      "electricity": 9.26,
      "site_grid": 5.67,
      "operations": 33.09,
      "total": 153.52,
      "electricity_usd_2026_kwh": 0.1195,
      "wacc": 0.058,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.86,
      "electricity": 1.27,
      "site_grid": 1.38,
      "operations": 3.26,
      "total": 23.76,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.0638,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.5,
      "electricity": 1.63,
      "site_grid": 1.26,
      "operations": 5.84,
      "total": 31.23,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.0638,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.26,
      "electricity": 3.44,
      "site_grid": 2.95,
      "operations": 7.56,
      "total": 52.21,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.0638,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.2,
      "electricity": 4.41,
      "site_grid": 2.71,
      "operations": 13.74,
      "total": 69.06,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.0638,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.64,
      "electricity": 8.11,
      "site_grid": 6.52,
      "operations": 18.02,
      "total": 117.29,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.0638,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.64,
      "electricity": 10.39,
      "site_grid": 5.99,
      "operations": 33.09,
      "total": 156.11,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.0638,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.6,
      "electricity": 1.31,
      "site_grid": 1.36,
      "operations": 3.26,
      "total": 23.53,
      "electricity_usd_2026_kwh": 0.1384,
      "wacc": 0.0561,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.18,
      "electricity": 1.68,
      "site_grid": 1.26,
      "operations": 5.84,
      "total": 30.96,
      "electricity_usd_2026_kwh": 0.1384,
      "wacc": 0.0561,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.71,
      "electricity": 3.55,
      "site_grid": 2.91,
      "operations": 7.56,
      "total": 51.74,
      "electricity_usd_2026_kwh": 0.1384,
      "wacc": 0.0561,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.52,
      "electricity": 4.55,
      "site_grid": 2.7,
      "operations": 13.74,
      "total": 68.51,
      "electricity_usd_2026_kwh": 0.1384,
      "wacc": 0.0561,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.44,
      "electricity": 8.37,
      "site_grid": 6.44,
      "operations": 18.02,
      "total": 116.27,
      "electricity_usd_2026_kwh": 0.1384,
      "wacc": 0.0561,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.13,
      "electricity": 10.73,
      "site_grid": 5.97,
      "operations": 33.09,
      "total": 154.92,
      "electricity_usd_2026_kwh": 0.1384,
      "wacc": 0.0561,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.19,
      "electricity": 1.35,
      "site_grid": 1.27,
      "operations": 3.26,
      "total": 23.07,
      "electricity_usd_2026_kwh": 0.1429,
      "wacc": 0.0436,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.66,
      "electricity": 1.73,
      "site_grid": 1.19,
      "operations": 5.84,
      "total": 30.44,
      "electricity_usd_2026_kwh": 0.1429,
      "wacc": 0.0436,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.83,
      "electricity": 3.67,
      "site_grid": 2.71,
      "operations": 7.56,
      "total": 50.78,
      "electricity_usd_2026_kwh": 0.1429,
      "wacc": 0.0436,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.42,
      "electricity": 4.7,
      "site_grid": 2.56,
      "operations": 13.74,
      "total": 67.41,
      "electricity_usd_2026_kwh": 0.1429,
      "wacc": 0.0436,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.49,
      "electricity": 8.64,
      "site_grid": 6.0,
      "operations": 18.02,
      "total": 114.15,
      "electricity_usd_2026_kwh": 0.1429,
      "wacc": 0.0436,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.69,
      "electricity": 11.07,
      "site_grid": 5.66,
      "operations": 33.09,
      "total": 152.51,
      "electricity_usd_2026_kwh": 0.1429,
      "wacc": 0.0436,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.37,
      "electricity": 1.31,
      "site_grid": 1.32,
      "operations": 3.26,
      "total": 23.27,
      "electricity_usd_2026_kwh": 0.1385,
      "wacc": 0.0492,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.89,
      "electricity": 1.68,
      "site_grid": 1.24,
      "operations": 5.84,
      "total": 30.66,
      "electricity_usd_2026_kwh": 0.1385,
      "wacc": 0.0492,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.23,
      "electricity": 3.55,
      "site_grid": 2.84,
      "operations": 7.56,
      "total": 51.18,
      "electricity_usd_2026_kwh": 0.1385,
      "wacc": 0.0492,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.91,
      "electricity": 4.55,
      "site_grid": 2.65,
      "operations": 13.74,
      "total": 67.85,
      "electricity_usd_2026_kwh": 0.1385,
      "wacc": 0.0492,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.36,
      "electricity": 8.37,
      "site_grid": 6.28,
      "operations": 18.02,
      "total": 115.02,
      "electricity_usd_2026_kwh": 0.1385,
      "wacc": 0.0492,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.77,
      "electricity": 10.73,
      "site_grid": 5.87,
      "operations": 33.09,
      "total": 153.46,
      "electricity_usd_2026_kwh": 0.1385,
      "wacc": 0.0492,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.87,
      "electricity": 2.0,
      "site_grid": 1.66,
      "operations": 3.26,
      "total": 24.79,
      "electricity_usd_2026_kwh": 0.2113,
      "wacc": 0.0642,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.51,
      "electricity": 2.56,
      "site_grid": 1.52,
      "operations": 5.84,
      "total": 32.45,
      "electricity_usd_2026_kwh": 0.2113,
      "wacc": 0.0642,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.29,
      "electricity": 5.42,
      "site_grid": 3.56,
      "operations": 7.56,
      "total": 54.83,
      "electricity_usd_2026_kwh": 0.2113,
      "wacc": 0.0642,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.24,
      "electricity": 6.95,
      "site_grid": 3.27,
      "operations": 13.74,
      "total": 72.19,
      "electricity_usd_2026_kwh": 0.2113,
      "wacc": 0.0642,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.71,
      "electricity": 12.77,
      "site_grid": 7.88,
      "operations": 18.02,
      "total": 123.37,
      "electricity_usd_2026_kwh": 0.2113,
      "wacc": 0.0642,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.72,
      "electricity": 16.37,
      "site_grid": 7.23,
      "operations": 33.09,
      "total": 163.4,
      "electricity_usd_2026_kwh": 0.2113,
      "wacc": 0.0642,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.21,
      "electricity": 2.37,
      "site_grid": 1.83,
      "operations": 3.26,
      "total": 25.66,
      "electricity_usd_2026_kwh": 0.25,
      "wacc": 0.0743,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.93,
      "electricity": 3.03,
      "site_grid": 1.66,
      "operations": 5.84,
      "total": 33.47,
      "electricity_usd_2026_kwh": 0.25,
      "wacc": 0.0743,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.0,
      "electricity": 6.42,
      "site_grid": 3.93,
      "operations": 7.56,
      "total": 56.91,
      "electricity_usd_2026_kwh": 0.25,
      "wacc": 0.0743,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.13,
      "electricity": 8.22,
      "site_grid": 3.56,
      "operations": 13.74,
      "total": 74.66,
      "electricity_usd_2026_kwh": 0.25,
      "wacc": 0.0743,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.29,
      "electricity": 15.11,
      "site_grid": 8.69,
      "operations": 18.02,
      "total": 128.11,
      "electricity_usd_2026_kwh": 0.25,
      "wacc": 0.0743,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.7,
      "electricity": 19.37,
      "site_grid": 7.88,
      "operations": 33.09,
      "total": 169.04,
      "electricity_usd_2026_kwh": 0.25,
      "wacc": 0.0743,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.29,
      "electricity": 1.9,
      "site_grid": 1.8,
      "operations": 3.26,
      "total": 25.25,
      "electricity_usd_2026_kwh": 0.2011,
      "wacc": 0.0768,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.04,
      "electricity": 2.44,
      "site_grid": 1.63,
      "operations": 5.84,
      "total": 32.95,
      "electricity_usd_2026_kwh": 0.2011,
      "wacc": 0.0768,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.18,
      "electricity": 5.16,
      "site_grid": 3.86,
      "operations": 7.56,
      "total": 55.77,
      "electricity_usd_2026_kwh": 0.2011,
      "wacc": 0.0768,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.36,
      "electricity": 6.61,
      "site_grid": 3.49,
      "operations": 13.74,
      "total": 73.2,
      "electricity_usd_2026_kwh": 0.2011,
      "wacc": 0.0768,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.69,
      "electricity": 12.15,
      "site_grid": 8.55,
      "operations": 18.02,
      "total": 125.4,
      "electricity_usd_2026_kwh": 0.2011,
      "wacc": 0.0768,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.19,
      "electricity": 15.58,
      "site_grid": 7.73,
      "operations": 33.09,
      "total": 165.59,
      "electricity_usd_2026_kwh": 0.2011,
      "wacc": 0.0768,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.32,
      "electricity": 1.68,
      "site_grid": 1.79,
      "operations": 3.26,
      "total": 25.04,
      "electricity_usd_2026_kwh": 0.1774,
      "wacc": 0.0776,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.07,
      "electricity": 2.15,
      "site_grid": 1.62,
      "operations": 5.84,
      "total": 32.68,
      "electricity_usd_2026_kwh": 0.1774,
      "wacc": 0.0776,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.24,
      "electricity": 4.55,
      "site_grid": 3.84,
      "operations": 7.56,
      "total": 55.19,
      "electricity_usd_2026_kwh": 0.1774,
      "wacc": 0.0776,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.43,
      "electricity": 5.84,
      "site_grid": 3.46,
      "operations": 13.74,
      "total": 72.47,
      "electricity_usd_2026_kwh": 0.1774,
      "wacc": 0.0776,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.82,
      "electricity": 10.72,
      "site_grid": 8.49,
      "operations": 18.02,
      "total": 124.04,
      "electricity_usd_2026_kwh": 0.1774,
      "wacc": 0.0776,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.36,
      "electricity": 13.74,
      "site_grid": 7.66,
      "operations": 33.09,
      "total": 163.86,
      "electricity_usd_2026_kwh": 0.1774,
      "wacc": 0.0776,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.33,
      "electricity": 1.63,
      "site_grid": 1.8,
      "operations": 3.26,
      "total": 25.02,
      "electricity_usd_2026_kwh": 0.1723,
      "wacc": 0.078,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.09,
      "electricity": 2.09,
      "site_grid": 1.62,
      "operations": 5.84,
      "total": 32.65,
      "electricity_usd_2026_kwh": 0.1723,
      "wacc": 0.078,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.27,
      "electricity": 4.42,
      "site_grid": 3.85,
      "operations": 7.56,
      "total": 55.11,
      "electricity_usd_2026_kwh": 0.1723,
      "wacc": 0.078,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.47,
      "electricity": 5.67,
      "site_grid": 3.48,
      "operations": 13.74,
      "total": 72.35,
      "electricity_usd_2026_kwh": 0.1723,
      "wacc": 0.078,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.88,
      "electricity": 10.42,
      "site_grid": 8.53,
      "operations": 18.02,
      "total": 123.84,
      "electricity_usd_2026_kwh": 0.1723,
      "wacc": 0.078,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.44,
      "electricity": 13.35,
      "site_grid": 7.7,
      "operations": 33.09,
      "total": 163.58,
      "electricity_usd_2026_kwh": 0.1723,
      "wacc": 0.078,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.68,
      "electricity": 2.23,
      "site_grid": 1.39,
      "operations": 3.24,
      "total": 24.54,
      "electricity_usd_2026_kwh": 0.2271,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.26,
      "electricity": 2.85,
      "site_grid": 1.35,
      "operations": 5.75,
      "total": 32.21,
      "electricity_usd_2026_kwh": 0.2271,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.88,
      "electricity": 6.04,
      "site_grid": 2.99,
      "operations": 7.53,
      "total": 54.43,
      "electricity_usd_2026_kwh": 0.2271,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.7,
      "electricity": 7.73,
      "site_grid": 2.89,
      "operations": 13.54,
      "total": 71.85,
      "electricity_usd_2026_kwh": 0.2271,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.81,
      "electricity": 14.21,
      "site_grid": 6.61,
      "operations": 17.94,
      "total": 122.58,
      "electricity_usd_2026_kwh": 0.2271,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.52,
      "electricity": 18.19,
      "site_grid": 6.39,
      "operations": 32.64,
      "total": 162.75,
      "electricity_usd_2026_kwh": 0.2271,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.8,
      "electricity": 2.3,
      "site_grid": 1.41,
      "operations": 3.24,
      "total": 24.75,
      "electricity_usd_2026_kwh": 0.2345,
      "wacc": 0.0675,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.41,
      "electricity": 2.94,
      "site_grid": 1.36,
      "operations": 5.75,
      "total": 32.46,
      "electricity_usd_2026_kwh": 0.2345,
      "wacc": 0.0675,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.14,
      "electricity": 6.23,
      "site_grid": 3.02,
      "operations": 7.53,
      "total": 54.92,
      "electricity_usd_2026_kwh": 0.2345,
      "wacc": 0.0675,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.02,
      "electricity": 7.98,
      "site_grid": 2.91,
      "operations": 13.54,
      "total": 72.44,
      "electricity_usd_2026_kwh": 0.2345,
      "wacc": 0.0675,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.38,
      "electricity": 14.68,
      "site_grid": 6.68,
      "operations": 17.94,
      "total": 123.68,
      "electricity_usd_2026_kwh": 0.2345,
      "wacc": 0.0675,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.24,
      "electricity": 18.79,
      "site_grid": 6.43,
      "operations": 32.64,
      "total": 164.1,
      "electricity_usd_2026_kwh": 0.2345,
      "wacc": 0.0675,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.81,
      "electricity": 2.19,
      "site_grid": 1.42,
      "operations": 3.24,
      "total": 24.65,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.0677,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.42,
      "electricity": 2.8,
      "site_grid": 1.37,
      "operations": 5.75,
      "total": 32.33,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.0677,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.16,
      "electricity": 5.92,
      "site_grid": 3.04,
      "operations": 7.53,
      "total": 54.65,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.0677,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.04,
      "electricity": 7.58,
      "site_grid": 2.93,
      "operations": 13.54,
      "total": 72.08,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.0677,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.41,
      "electricity": 13.95,
      "site_grid": 6.73,
      "operations": 17.94,
      "total": 123.03,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.0677,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.28,
      "electricity": 17.86,
      "site_grid": 6.47,
      "operations": 32.64,
      "total": 163.25,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.0677,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.79,
      "electricity": 2.24,
      "site_grid": 1.43,
      "operations": 3.24,
      "total": 24.7,
      "electricity_usd_2026_kwh": 0.2286,
      "wacc": 0.0672,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.4,
      "electricity": 2.87,
      "site_grid": 1.37,
      "operations": 5.75,
      "total": 32.39,
      "electricity_usd_2026_kwh": 0.2286,
      "wacc": 0.0672,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.12,
      "electricity": 6.07,
      "site_grid": 3.06,
      "operations": 7.53,
      "total": 54.77,
      "electricity_usd_2026_kwh": 0.2286,
      "wacc": 0.0672,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.99,
      "electricity": 7.78,
      "site_grid": 2.94,
      "operations": 13.54,
      "total": 72.24,
      "electricity_usd_2026_kwh": 0.2286,
      "wacc": 0.0672,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.33,
      "electricity": 14.31,
      "site_grid": 6.76,
      "operations": 17.94,
      "total": 123.34,
      "electricity_usd_2026_kwh": 0.2286,
      "wacc": 0.0672,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.17,
      "electricity": 18.31,
      "site_grid": 6.51,
      "operations": 32.64,
      "total": 163.63,
      "electricity_usd_2026_kwh": 0.2286,
      "wacc": 0.0672,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.62,
      "electricity": 2.19,
      "site_grid": 1.4,
      "operations": 3.24,
      "total": 24.46,
      "electricity_usd_2026_kwh": 0.2239,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.19,
      "electricity": 2.81,
      "site_grid": 1.36,
      "operations": 5.75,
      "total": 32.11,
      "electricity_usd_2026_kwh": 0.2239,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.76,
      "electricity": 5.95,
      "site_grid": 3.0,
      "operations": 7.53,
      "total": 54.24,
      "electricity_usd_2026_kwh": 0.2239,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.54,
      "electricity": 7.62,
      "site_grid": 2.91,
      "operations": 13.54,
      "total": 71.6,
      "electricity_usd_2026_kwh": 0.2239,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.54,
      "electricity": 14.01,
      "site_grid": 6.64,
      "operations": 17.94,
      "total": 122.13,
      "electricity_usd_2026_kwh": 0.2239,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.18,
      "electricity": 17.94,
      "site_grid": 6.43,
      "operations": 32.64,
      "total": 162.19,
      "electricity_usd_2026_kwh": 0.2239,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.33,
      "electricity": 1.75,
      "site_grid": 1.34,
      "operations": 3.24,
      "total": 23.66,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.82,
      "electricity": 2.24,
      "site_grid": 1.31,
      "operations": 5.75,
      "total": 31.13,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.13,
      "electricity": 4.74,
      "site_grid": 2.87,
      "operations": 7.53,
      "total": 52.27,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.75,
      "electricity": 6.07,
      "site_grid": 2.82,
      "operations": 13.54,
      "total": 69.18,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.14,
      "electricity": 11.17,
      "site_grid": 6.35,
      "operations": 17.94,
      "total": 117.61,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.44,
      "electricity": 14.3,
      "site_grid": 6.23,
      "operations": 32.64,
      "total": 156.6,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.23,
      "electricity": 1.59,
      "site_grid": 1.3,
      "operations": 3.24,
      "total": 23.37,
      "electricity_usd_2026_kwh": 0.1627,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.7,
      "electricity": 2.04,
      "site_grid": 1.28,
      "operations": 5.75,
      "total": 30.77,
      "electricity_usd_2026_kwh": 0.1627,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.92,
      "electricity": 4.32,
      "site_grid": 2.79,
      "operations": 7.53,
      "total": 51.56,
      "electricity_usd_2026_kwh": 0.1627,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.49,
      "electricity": 5.53,
      "site_grid": 2.75,
      "operations": 13.54,
      "total": 68.31,
      "electricity_usd_2026_kwh": 0.1627,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.68,
      "electricity": 10.18,
      "site_grid": 6.18,
      "operations": 17.94,
      "total": 115.98,
      "electricity_usd_2026_kwh": 0.1627,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.86,
      "electricity": 13.03,
      "site_grid": 6.09,
      "operations": 32.64,
      "total": 154.61,
      "electricity_usd_2026_kwh": 0.1627,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.39,
      "electricity": 1.56,
      "site_grid": 1.35,
      "operations": 3.24,
      "total": 23.55,
      "electricity_usd_2026_kwh": 0.1595,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.9,
      "electricity": 2.0,
      "site_grid": 1.32,
      "operations": 5.75,
      "total": 30.98,
      "electricity_usd_2026_kwh": 0.1595,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.26,
      "electricity": 4.24,
      "site_grid": 2.9,
      "operations": 7.53,
      "total": 51.93,
      "electricity_usd_2026_kwh": 0.1595,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.92,
      "electricity": 5.42,
      "site_grid": 2.84,
      "operations": 13.54,
      "total": 68.72,
      "electricity_usd_2026_kwh": 0.1595,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.44,
      "electricity": 9.98,
      "site_grid": 6.42,
      "operations": 17.94,
      "total": 116.78,
      "electricity_usd_2026_kwh": 0.1595,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.81,
      "electricity": 12.77,
      "site_grid": 6.28,
      "operations": 32.64,
      "total": 155.5,
      "electricity_usd_2026_kwh": 0.1595,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.58,
      "electricity": 1.64,
      "site_grid": 1.44,
      "operations": 3.24,
      "total": 23.91,
      "electricity_usd_2026_kwh": 0.1677,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.14,
      "electricity": 2.1,
      "site_grid": 1.4,
      "operations": 5.75,
      "total": 31.39,
      "electricity_usd_2026_kwh": 0.1677,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.67,
      "electricity": 4.46,
      "site_grid": 3.09,
      "operations": 7.53,
      "total": 52.74,
      "electricity_usd_2026_kwh": 0.1677,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.43,
      "electricity": 5.7,
      "site_grid": 3.0,
      "operations": 13.54,
      "total": 69.67,
      "electricity_usd_2026_kwh": 0.1677,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.34,
      "electricity": 10.49,
      "site_grid": 6.83,
      "operations": 17.94,
      "total": 118.6,
      "electricity_usd_2026_kwh": 0.1677,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.93,
      "electricity": 13.43,
      "site_grid": 6.63,
      "operations": 32.64,
      "total": 157.63,
      "electricity_usd_2026_kwh": 0.1677,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.33,
      "electricity": 1.6,
      "site_grid": 1.42,
      "operations": 3.24,
      "total": 23.59,
      "electricity_usd_2026_kwh": 0.1631,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.82,
      "electricity": 2.05,
      "site_grid": 1.39,
      "operations": 5.75,
      "total": 31.01,
      "electricity_usd_2026_kwh": 0.1631,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.13,
      "electricity": 4.33,
      "site_grid": 3.05,
      "operations": 7.53,
      "total": 52.04,
      "electricity_usd_2026_kwh": 0.1631,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.76,
      "electricity": 5.55,
      "site_grid": 2.99,
      "operations": 13.54,
      "total": 68.83,
      "electricity_usd_2026_kwh": 0.1631,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.15,
      "electricity": 10.2,
      "site_grid": 6.74,
      "operations": 17.94,
      "total": 117.04,
      "electricity_usd_2026_kwh": 0.1631,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.44,
      "electricity": 13.06,
      "site_grid": 6.61,
      "operations": 32.64,
      "total": 155.75,
      "electricity_usd_2026_kwh": 0.1631,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.92,
      "electricity": 1.61,
      "site_grid": 1.32,
      "operations": 3.24,
      "total": 23.1,
      "electricity_usd_2026_kwh": 0.1641,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.32,
      "electricity": 2.06,
      "site_grid": 1.32,
      "operations": 5.75,
      "total": 30.45,
      "electricity_usd_2026_kwh": 0.1641,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.26,
      "electricity": 4.36,
      "site_grid": 2.84,
      "operations": 7.53,
      "total": 50.99,
      "electricity_usd_2026_kwh": 0.1641,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.67,
      "electricity": 5.58,
      "site_grid": 2.83,
      "operations": 13.54,
      "total": 67.62,
      "electricity_usd_2026_kwh": 0.1641,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.22,
      "electricity": 10.27,
      "site_grid": 6.28,
      "operations": 17.94,
      "total": 114.71,
      "electricity_usd_2026_kwh": 0.1641,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.03,
      "electricity": 13.15,
      "site_grid": 6.26,
      "operations": 32.64,
      "total": 153.08,
      "electricity_usd_2026_kwh": 0.1641,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.11,
      "electricity": 1.79,
      "site_grid": 1.39,
      "operations": 3.24,
      "total": 23.52,
      "electricity_usd_2026_kwh": 0.1828,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.54,
      "electricity": 2.29,
      "site_grid": 1.37,
      "operations": 5.75,
      "total": 30.95,
      "electricity_usd_2026_kwh": 0.1828,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.65,
      "electricity": 4.86,
      "site_grid": 2.97,
      "operations": 7.53,
      "total": 52.0,
      "electricity_usd_2026_kwh": 0.1828,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.15,
      "electricity": 6.22,
      "site_grid": 2.94,
      "operations": 13.54,
      "total": 68.84,
      "electricity_usd_2026_kwh": 0.1828,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.08,
      "electricity": 11.44,
      "site_grid": 6.57,
      "operations": 17.94,
      "total": 117.02,
      "electricity_usd_2026_kwh": 0.1828,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.11,
      "electricity": 14.64,
      "site_grid": 6.5,
      "operations": 32.64,
      "total": 155.88,
      "electricity_usd_2026_kwh": 0.1828,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.59,
      "electricity": 2.38,
      "site_grid": 1.74,
      "operations": 3.24,
      "total": 24.95,
      "electricity_usd_2026_kwh": 0.2427,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.15,
      "electricity": 3.05,
      "site_grid": 1.69,
      "operations": 5.75,
      "total": 32.64,
      "electricity_usd_2026_kwh": 0.2427,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.7,
      "electricity": 6.45,
      "site_grid": 3.73,
      "operations": 7.53,
      "total": 55.4,
      "electricity_usd_2026_kwh": 0.2427,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.47,
      "electricity": 8.26,
      "site_grid": 3.62,
      "operations": 13.54,
      "total": 72.87,
      "electricity_usd_2026_kwh": 0.2427,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.4,
      "electricity": 15.19,
      "site_grid": 8.25,
      "operations": 17.94,
      "total": 124.78,
      "electricity_usd_2026_kwh": 0.2427,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.01,
      "electricity": 19.44,
      "site_grid": 8.0,
      "operations": 32.64,
      "total": 165.09,
      "electricity_usd_2026_kwh": 0.2427,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.93,
      "electricity": 1.8,
      "site_grid": 1.92,
      "operations": 3.24,
      "total": 24.89,
      "electricity_usd_2026_kwh": 0.1839,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.57,
      "electricity": 2.31,
      "site_grid": 1.84,
      "operations": 5.75,
      "total": 32.47,
      "electricity_usd_2026_kwh": 0.1839,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.41,
      "electricity": 4.89,
      "site_grid": 4.12,
      "operations": 7.53,
      "total": 54.94,
      "electricity_usd_2026_kwh": 0.1839,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.35,
      "electricity": 6.25,
      "site_grid": 3.95,
      "operations": 13.54,
      "total": 72.09,
      "electricity_usd_2026_kwh": 0.1839,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.97,
      "electricity": 11.51,
      "site_grid": 9.11,
      "operations": 17.94,
      "total": 123.53,
      "electricity_usd_2026_kwh": 0.1839,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.97,
      "electricity": 14.73,
      "site_grid": 8.73,
      "operations": 32.64,
      "total": 163.07,
      "electricity_usd_2026_kwh": 0.1839,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.01,
      "electricity": 1.56,
      "site_grid": 1.89,
      "operations": 3.24,
      "total": 24.7,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.67,
      "electricity": 2.0,
      "site_grid": 1.81,
      "operations": 5.75,
      "total": 32.23,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.58,
      "electricity": 4.24,
      "site_grid": 4.05,
      "operations": 7.53,
      "total": 54.4,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.57,
      "electricity": 5.42,
      "site_grid": 3.87,
      "operations": 13.54,
      "total": 71.4,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.36,
      "electricity": 9.98,
      "site_grid": 8.96,
      "operations": 17.94,
      "total": 122.24,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.46,
      "electricity": 12.77,
      "site_grid": 8.56,
      "operations": 32.64,
      "total": 161.43,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.04,
      "electricity": 1.56,
      "site_grid": 1.88,
      "operations": 3.24,
      "total": 24.71,
      "electricity_usd_2026_kwh": 0.1586,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.71,
      "electricity": 1.99,
      "site_grid": 1.79,
      "operations": 5.75,
      "total": 32.24,
      "electricity_usd_2026_kwh": 0.1586,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.64,
      "electricity": 4.22,
      "site_grid": 4.02,
      "operations": 7.53,
      "total": 54.41,
      "electricity_usd_2026_kwh": 0.1586,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.65,
      "electricity": 5.4,
      "site_grid": 3.84,
      "operations": 13.54,
      "total": 71.42,
      "electricity_usd_2026_kwh": 0.1586,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.49,
      "electricity": 9.93,
      "site_grid": 8.9,
      "operations": 17.94,
      "total": 122.26,
      "electricity_usd_2026_kwh": 0.1586,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.62,
      "electricity": 12.71,
      "site_grid": 8.49,
      "operations": 32.64,
      "total": 161.46,
      "electricity_usd_2026_kwh": 0.1586,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.05,
      "electricity": 1.49,
      "site_grid": 1.89,
      "operations": 3.24,
      "total": 24.66,
      "electricity_usd_2026_kwh": 0.1518,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.72,
      "electricity": 1.9,
      "site_grid": 1.8,
      "operations": 5.75,
      "total": 32.17,
      "electricity_usd_2026_kwh": 0.1518,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.67,
      "electricity": 4.03,
      "site_grid": 4.04,
      "operations": 7.53,
      "total": 54.27,
      "electricity_usd_2026_kwh": 0.1518,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.68,
      "electricity": 5.16,
      "site_grid": 3.86,
      "operations": 13.54,
      "total": 71.24,
      "electricity_usd_2026_kwh": 0.1518,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.55,
      "electricity": 9.5,
      "site_grid": 8.94,
      "operations": 17.94,
      "total": 121.93,
      "electricity_usd_2026_kwh": 0.1518,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.7,
      "electricity": 12.16,
      "site_grid": 8.53,
      "operations": 32.64,
      "total": 161.03,
      "electricity_usd_2026_kwh": 0.1518,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.74,
      "electricity": 1.51,
      "site_grid": 1.23,
      "operations": 3.24,
      "total": 22.71,
      "electricity_usd_2026_kwh": 0.1654,
      "wacc": 0.0508,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.04,
      "electricity": 1.91,
      "site_grid": 1.17,
      "operations": 6.32,
      "total": 30.45,
      "electricity_usd_2026_kwh": 0.1654,
      "wacc": 0.0508,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.86,
      "electricity": 4.09,
      "site_grid": 2.63,
      "operations": 7.52,
      "total": 50.1,
      "electricity_usd_2026_kwh": 0.1654,
      "wacc": 0.0508,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.08,
      "electricity": 5.18,
      "site_grid": 2.52,
      "operations": 14.75,
      "total": 67.53,
      "electricity_usd_2026_kwh": 0.1654,
      "wacc": 0.0508,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.34,
      "electricity": 9.62,
      "site_grid": 5.82,
      "operations": 17.92,
      "total": 112.71,
      "electricity_usd_2026_kwh": 0.1654,
      "wacc": 0.0508,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.73,
      "electricity": 12.2,
      "site_grid": 5.57,
      "operations": 35.32,
      "total": 152.82,
      "electricity_usd_2026_kwh": 0.1654,
      "wacc": 0.0508,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.6,
      "electricity": 1.6,
      "site_grid": 1.18,
      "operations": 3.24,
      "total": 22.62,
      "electricity_usd_2026_kwh": 0.176,
      "wacc": 0.0465,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.87,
      "electricity": 2.03,
      "site_grid": 1.13,
      "operations": 6.32,
      "total": 30.35,
      "electricity_usd_2026_kwh": 0.176,
      "wacc": 0.0465,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.57,
      "electricity": 4.35,
      "site_grid": 2.52,
      "operations": 7.52,
      "total": 49.96,
      "electricity_usd_2026_kwh": 0.176,
      "wacc": 0.0465,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.72,
      "electricity": 5.51,
      "site_grid": 2.42,
      "operations": 14.75,
      "total": 67.4,
      "electricity_usd_2026_kwh": 0.176,
      "wacc": 0.0465,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.7,
      "electricity": 10.24,
      "site_grid": 5.57,
      "operations": 17.92,
      "total": 112.43,
      "electricity_usd_2026_kwh": 0.176,
      "wacc": 0.0465,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.93,
      "electricity": 12.99,
      "site_grid": 5.36,
      "operations": 35.32,
      "total": 152.59,
      "electricity_usd_2026_kwh": 0.176,
      "wacc": 0.0465,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.4,
      "electricity": 1.34,
      "site_grid": 1.13,
      "operations": 3.24,
      "total": 22.1,
      "electricity_usd_2026_kwh": 0.1466,
      "wacc": 0.0367,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.49,
      "electricity": 1.69,
      "site_grid": 1.07,
      "operations": 6.32,
      "total": 29.57,
      "electricity_usd_2026_kwh": 0.1466,
      "wacc": 0.0367,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.13,
      "electricity": 3.62,
      "site_grid": 2.42,
      "operations": 7.52,
      "total": 48.69,
      "electricity_usd_2026_kwh": 0.1466,
      "wacc": 0.0367,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 43.89,
      "electricity": 4.59,
      "site_grid": 2.3,
      "operations": 14.75,
      "total": 65.54,
      "electricity_usd_2026_kwh": 0.1466,
      "wacc": 0.0367,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.73,
      "electricity": 8.53,
      "site_grid": 5.35,
      "operations": 17.92,
      "total": 109.53,
      "electricity_usd_2026_kwh": 0.1466,
      "wacc": 0.0367,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 97.11,
      "electricity": 10.82,
      "site_grid": 5.09,
      "operations": 35.32,
      "total": 148.34,
      "electricity_usd_2026_kwh": 0.1466,
      "wacc": 0.0367,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.47,
      "electricity": 1.33,
      "site_grid": 1.16,
      "operations": 3.24,
      "total": 22.19,
      "electricity_usd_2026_kwh": 0.1461,
      "wacc": 0.0422,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.7,
      "electricity": 1.69,
      "site_grid": 1.12,
      "operations": 6.32,
      "total": 29.83,
      "electricity_usd_2026_kwh": 0.1461,
      "wacc": 0.0422,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.28,
      "electricity": 3.61,
      "site_grid": 2.48,
      "operations": 7.52,
      "total": 48.88,
      "electricity_usd_2026_kwh": 0.1461,
      "wacc": 0.0422,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.35,
      "electricity": 4.58,
      "site_grid": 2.4,
      "operations": 14.75,
      "total": 66.08,
      "electricity_usd_2026_kwh": 0.1461,
      "wacc": 0.0422,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.05,
      "electricity": 8.5,
      "site_grid": 5.48,
      "operations": 17.92,
      "total": 109.95,
      "electricity_usd_2026_kwh": 0.1461,
      "wacc": 0.0422,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.12,
      "electricity": 10.78,
      "site_grid": 5.3,
      "operations": 35.32,
      "total": 149.52,
      "electricity_usd_2026_kwh": 0.1461,
      "wacc": 0.0422,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.53,
      "electricity": 1.16,
      "site_grid": 1.19,
      "operations": 3.24,
      "total": 22.12,
      "electricity_usd_2026_kwh": 0.1275,
      "wacc": 0.0441,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.78,
      "electricity": 1.47,
      "site_grid": 1.15,
      "operations": 6.32,
      "total": 29.72,
      "electricity_usd_2026_kwh": 0.1275,
      "wacc": 0.0441,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.41,
      "electricity": 3.15,
      "site_grid": 2.55,
      "operations": 7.52,
      "total": 48.63,
      "electricity_usd_2026_kwh": 0.1275,
      "wacc": 0.0441,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.51,
      "electricity": 3.99,
      "site_grid": 2.46,
      "operations": 14.75,
      "total": 65.72,
      "electricity_usd_2026_kwh": 0.1275,
      "wacc": 0.0441,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.34,
      "electricity": 7.42,
      "site_grid": 5.64,
      "operations": 17.92,
      "total": 109.31,
      "electricity_usd_2026_kwh": 0.1275,
      "wacc": 0.0441,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.48,
      "electricity": 9.41,
      "site_grid": 5.44,
      "operations": 35.32,
      "total": 148.64,
      "electricity_usd_2026_kwh": 0.1275,
      "wacc": 0.0441,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.4,
      "electricity": 0.85,
      "site_grid": 1.18,
      "operations": 3.24,
      "total": 21.67,
      "electricity_usd_2026_kwh": 0.0938,
      "wacc": 0.0401,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.62,
      "electricity": 1.08,
      "site_grid": 1.14,
      "operations": 6.32,
      "total": 29.16,
      "electricity_usd_2026_kwh": 0.0938,
      "wacc": 0.0401,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.14,
      "electricity": 2.32,
      "site_grid": 2.52,
      "operations": 7.52,
      "total": 47.5,
      "electricity_usd_2026_kwh": 0.0938,
      "wacc": 0.0401,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.17,
      "electricity": 2.94,
      "site_grid": 2.45,
      "operations": 14.75,
      "total": 64.31,
      "electricity_usd_2026_kwh": 0.0938,
      "wacc": 0.0401,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.74,
      "electricity": 5.46,
      "site_grid": 5.58,
      "operations": 17.92,
      "total": 106.7,
      "electricity_usd_2026_kwh": 0.0938,
      "wacc": 0.0401,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 97.73,
      "electricity": 6.92,
      "site_grid": 5.41,
      "operations": 35.32,
      "total": 145.39,
      "electricity_usd_2026_kwh": 0.0938,
      "wacc": 0.0401,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.4,
      "electricity": 0.88,
      "site_grid": 1.17,
      "operations": 3.24,
      "total": 21.69,
      "electricity_usd_2026_kwh": 0.097,
      "wacc": 0.0371,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.5,
      "electricity": 1.12,
      "site_grid": 1.12,
      "operations": 6.32,
      "total": 29.05,
      "electricity_usd_2026_kwh": 0.097,
      "wacc": 0.0371,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.13,
      "electricity": 2.39,
      "site_grid": 2.5,
      "operations": 7.52,
      "total": 47.55,
      "electricity_usd_2026_kwh": 0.097,
      "wacc": 0.0371,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 43.92,
      "electricity": 3.04,
      "site_grid": 2.39,
      "operations": 14.75,
      "total": 64.1,
      "electricity_usd_2026_kwh": 0.097,
      "wacc": 0.0371,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.73,
      "electricity": 5.64,
      "site_grid": 5.54,
      "operations": 17.92,
      "total": 106.83,
      "electricity_usd_2026_kwh": 0.097,
      "wacc": 0.0371,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 97.17,
      "electricity": 7.15,
      "site_grid": 5.29,
      "operations": 35.32,
      "total": 144.93,
      "electricity_usd_2026_kwh": 0.097,
      "wacc": 0.0371,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.46,
      "electricity": 0.9,
      "site_grid": 1.19,
      "operations": 3.24,
      "total": 21.79,
      "electricity_usd_2026_kwh": 0.0987,
      "wacc": 0.042,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.69,
      "electricity": 1.14,
      "site_grid": 1.15,
      "operations": 6.32,
      "total": 29.3,
      "electricity_usd_2026_kwh": 0.0987,
      "wacc": 0.042,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.27,
      "electricity": 2.44,
      "site_grid": 2.55,
      "operations": 7.52,
      "total": 47.77,
      "electricity_usd_2026_kwh": 0.0987,
      "wacc": 0.042,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.33,
      "electricity": 3.09,
      "site_grid": 2.47,
      "operations": 14.75,
      "total": 64.64,
      "electricity_usd_2026_kwh": 0.0987,
      "wacc": 0.042,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.02,
      "electricity": 5.74,
      "site_grid": 5.64,
      "operations": 17.92,
      "total": 107.33,
      "electricity_usd_2026_kwh": 0.0987,
      "wacc": 0.042,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.08,
      "electricity": 7.28,
      "site_grid": 5.46,
      "operations": 35.32,
      "total": 146.14,
      "electricity_usd_2026_kwh": 0.0987,
      "wacc": 0.042,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.64,
      "electricity": 1.0,
      "site_grid": 1.27,
      "operations": 3.24,
      "total": 22.15,
      "electricity_usd_2026_kwh": 0.1097,
      "wacc": 0.0478,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.92,
      "electricity": 1.27,
      "site_grid": 1.22,
      "operations": 6.32,
      "total": 29.72,
      "electricity_usd_2026_kwh": 0.1097,
      "wacc": 0.0478,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.66,
      "electricity": 2.71,
      "site_grid": 2.72,
      "operations": 7.52,
      "total": 48.6,
      "electricity_usd_2026_kwh": 0.1097,
      "wacc": 0.0478,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.82,
      "electricity": 3.44,
      "site_grid": 2.61,
      "operations": 14.75,
      "total": 65.62,
      "electricity_usd_2026_kwh": 0.1097,
      "wacc": 0.0478,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.89,
      "electricity": 6.38,
      "site_grid": 6.01,
      "operations": 17.92,
      "total": 109.2,
      "electricity_usd_2026_kwh": 0.1097,
      "wacc": 0.0478,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.17,
      "electricity": 8.09,
      "site_grid": 5.77,
      "operations": 35.32,
      "total": 148.35,
      "electricity_usd_2026_kwh": 0.1097,
      "wacc": 0.0478,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.4,
      "electricity": 0.97,
      "site_grid": 1.25,
      "operations": 3.24,
      "total": 21.85,
      "electricity_usd_2026_kwh": 0.1061,
      "wacc": 0.0401,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.62,
      "electricity": 1.23,
      "site_grid": 1.21,
      "operations": 6.32,
      "total": 29.38,
      "electricity_usd_2026_kwh": 0.1061,
      "wacc": 0.0401,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.14,
      "electricity": 2.62,
      "site_grid": 2.68,
      "operations": 7.52,
      "total": 47.96,
      "electricity_usd_2026_kwh": 0.1061,
      "wacc": 0.0401,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.18,
      "electricity": 3.33,
      "site_grid": 2.6,
      "operations": 14.75,
      "total": 64.85,
      "electricity_usd_2026_kwh": 0.1061,
      "wacc": 0.0401,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.74,
      "electricity": 6.17,
      "site_grid": 5.92,
      "operations": 17.92,
      "total": 107.76,
      "electricity_usd_2026_kwh": 0.1061,
      "wacc": 0.0401,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 97.74,
      "electricity": 7.83,
      "site_grid": 5.75,
      "operations": 35.32,
      "total": 146.63,
      "electricity_usd_2026_kwh": 0.1061,
      "wacc": 0.0401,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.4,
      "electricity": 0.84,
      "site_grid": 1.27,
      "operations": 3.24,
      "total": 21.74,
      "electricity_usd_2026_kwh": 0.0921,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.42,
      "electricity": 1.06,
      "site_grid": 1.2,
      "operations": 6.32,
      "total": 29.0,
      "electricity_usd_2026_kwh": 0.0921,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.13,
      "electricity": 2.27,
      "site_grid": 2.72,
      "operations": 7.52,
      "total": 47.65,
      "electricity_usd_2026_kwh": 0.0921,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 43.75,
      "electricity": 2.88,
      "site_grid": 2.56,
      "operations": 14.75,
      "total": 63.95,
      "electricity_usd_2026_kwh": 0.0921,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.73,
      "electricity": 5.36,
      "site_grid": 6.02,
      "operations": 17.92,
      "total": 107.02,
      "electricity_usd_2026_kwh": 0.0921,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 96.79,
      "electricity": 6.79,
      "site_grid": 5.67,
      "operations": 35.32,
      "total": 144.58,
      "electricity_usd_2026_kwh": 0.0921,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.4,
      "electricity": 1.11,
      "site_grid": 1.28,
      "operations": 3.24,
      "total": 22.02,
      "electricity_usd_2026_kwh": 0.1222,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.42,
      "electricity": 1.41,
      "site_grid": 1.2,
      "operations": 6.32,
      "total": 29.35,
      "electricity_usd_2026_kwh": 0.1222,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.13,
      "electricity": 3.02,
      "site_grid": 2.73,
      "operations": 7.52,
      "total": 48.4,
      "electricity_usd_2026_kwh": 0.1222,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 43.75,
      "electricity": 3.83,
      "site_grid": 2.58,
      "operations": 14.75,
      "total": 64.9,
      "electricity_usd_2026_kwh": 0.1222,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.73,
      "electricity": 7.1,
      "site_grid": 6.05,
      "operations": 17.92,
      "total": 108.8,
      "electricity_usd_2026_kwh": 0.1222,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 96.79,
      "electricity": 9.01,
      "site_grid": 5.7,
      "operations": 35.32,
      "total": 146.82,
      "electricity_usd_2026_kwh": 0.1222,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.66,
      "electricity": 1.43,
      "site_grid": 1.53,
      "operations": 3.24,
      "total": 22.86,
      "electricity_usd_2026_kwh": 0.1574,
      "wacc": 0.0482,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.94,
      "electricity": 1.82,
      "site_grid": 1.47,
      "operations": 6.32,
      "total": 30.54,
      "electricity_usd_2026_kwh": 0.1574,
      "wacc": 0.0482,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.69,
      "electricity": 3.89,
      "site_grid": 3.28,
      "operations": 7.52,
      "total": 50.37,
      "electricity_usd_2026_kwh": 0.1574,
      "wacc": 0.0482,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.86,
      "electricity": 4.93,
      "site_grid": 3.15,
      "operations": 14.75,
      "total": 67.69,
      "electricity_usd_2026_kwh": 0.1574,
      "wacc": 0.0482,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.95,
      "electricity": 9.15,
      "site_grid": 7.26,
      "operations": 17.92,
      "total": 113.28,
      "electricity_usd_2026_kwh": 0.1574,
      "wacc": 0.0482,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.24,
      "electricity": 11.61,
      "site_grid": 6.97,
      "operations": 35.32,
      "total": 153.14,
      "electricity_usd_2026_kwh": 0.1574,
      "wacc": 0.0482,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.97,
      "electricity": 1.05,
      "site_grid": 1.7,
      "operations": 3.24,
      "total": 22.96,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0583,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.33,
      "electricity": 1.34,
      "site_grid": 1.61,
      "operations": 6.32,
      "total": 30.6,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0583,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.37,
      "electricity": 2.86,
      "site_grid": 3.64,
      "operations": 7.52,
      "total": 50.38,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0583,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.71,
      "electricity": 3.62,
      "site_grid": 3.44,
      "operations": 14.75,
      "total": 67.52,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0583,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.46,
      "electricity": 6.72,
      "site_grid": 8.04,
      "operations": 17.92,
      "total": 113.15,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0583,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.13,
      "electricity": 8.53,
      "site_grid": 7.62,
      "operations": 35.32,
      "total": 152.59,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0583,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.05,
      "electricity": 0.93,
      "site_grid": 1.67,
      "operations": 3.24,
      "total": 22.89,
      "electricity_usd_2026_kwh": 0.1023,
      "wacc": 0.0608,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.43,
      "electricity": 1.18,
      "site_grid": 1.58,
      "operations": 6.32,
      "total": 30.51,
      "electricity_usd_2026_kwh": 0.1023,
      "wacc": 0.0608,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.54,
      "electricity": 2.53,
      "site_grid": 3.58,
      "operations": 7.52,
      "total": 50.16,
      "electricity_usd_2026_kwh": 0.1023,
      "wacc": 0.0608,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.92,
      "electricity": 3.21,
      "site_grid": 3.38,
      "operations": 14.75,
      "total": 67.26,
      "electricity_usd_2026_kwh": 0.1023,
      "wacc": 0.0608,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.83,
      "electricity": 5.95,
      "site_grid": 7.92,
      "operations": 17.92,
      "total": 112.62,
      "electricity_usd_2026_kwh": 0.1023,
      "wacc": 0.0608,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.59,
      "electricity": 7.55,
      "site_grid": 7.47,
      "operations": 35.32,
      "total": 151.94,
      "electricity_usd_2026_kwh": 0.1023,
      "wacc": 0.0608,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.08,
      "electricity": 1.02,
      "site_grid": 1.66,
      "operations": 3.24,
      "total": 23.0,
      "electricity_usd_2026_kwh": 0.1122,
      "wacc": 0.0616,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.47,
      "electricity": 1.3,
      "site_grid": 1.56,
      "operations": 6.32,
      "total": 30.65,
      "electricity_usd_2026_kwh": 0.1122,
      "wacc": 0.0616,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.59,
      "electricity": 2.77,
      "site_grid": 3.55,
      "operations": 7.52,
      "total": 50.44,
      "electricity_usd_2026_kwh": 0.1122,
      "wacc": 0.0616,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.99,
      "electricity": 3.51,
      "site_grid": 3.35,
      "operations": 14.75,
      "total": 67.61,
      "electricity_usd_2026_kwh": 0.1122,
      "wacc": 0.0616,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.96,
      "electricity": 6.52,
      "site_grid": 7.86,
      "operations": 17.92,
      "total": 113.27,
      "electricity_usd_2026_kwh": 0.1122,
      "wacc": 0.0616,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.75,
      "electricity": 8.28,
      "site_grid": 7.41,
      "operations": 35.32,
      "total": 152.76,
      "electricity_usd_2026_kwh": 0.1122,
      "wacc": 0.0616,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.09,
      "electricity": 1.01,
      "site_grid": 1.67,
      "operations": 3.24,
      "total": 23.01,
      "electricity_usd_2026_kwh": 0.1112,
      "wacc": 0.062,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.48,
      "electricity": 1.29,
      "site_grid": 1.57,
      "operations": 6.32,
      "total": 30.66,
      "electricity_usd_2026_kwh": 0.1112,
      "wacc": 0.062,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.62,
      "electricity": 2.75,
      "site_grid": 3.57,
      "operations": 7.52,
      "total": 50.46,
      "electricity_usd_2026_kwh": 0.1112,
      "wacc": 0.062,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.03,
      "electricity": 3.48,
      "site_grid": 3.37,
      "operations": 14.75,
      "total": 67.63,
      "electricity_usd_2026_kwh": 0.1112,
      "wacc": 0.062,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.02,
      "electricity": 6.47,
      "site_grid": 7.9,
      "operations": 17.92,
      "total": 113.31,
      "electricity_usd_2026_kwh": 0.1112,
      "wacc": 0.062,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.82,
      "electricity": 8.21,
      "site_grid": 7.45,
      "operations": 35.32,
      "total": 152.8,
      "electricity_usd_2026_kwh": 0.1112,
      "wacc": 0.062,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.54,
      "electricity": 0.75,
      "site_grid": 1.39,
      "operations": 3.43,
      "total": 24.12,
      "electricity_usd_2026_kwh": 0.0827,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.36,
      "electricity": 0.95,
      "site_grid": 1.34,
      "operations": 6.54,
      "total": 32.18,
      "electricity_usd_2026_kwh": 0.0827,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.72,
      "electricity": 2.05,
      "site_grid": 2.99,
      "operations": 7.93,
      "total": 52.68,
      "electricity_usd_2026_kwh": 0.0827,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.04,
      "electricity": 2.58,
      "site_grid": 2.86,
      "operations": 15.22,
      "total": 70.71,
      "electricity_usd_2026_kwh": 0.0827,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.87,
      "electricity": 4.82,
      "site_grid": 6.61,
      "operations": 18.84,
      "total": 118.14,
      "electricity_usd_2026_kwh": 0.0827,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.71,
      "electricity": 6.07,
      "site_grid": 6.33,
      "operations": 36.38,
      "total": 159.49,
      "electricity_usd_2026_kwh": 0.0827,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.39,
      "electricity": 0.82,
      "site_grid": 1.34,
      "operations": 3.43,
      "total": 23.98,
      "electricity_usd_2026_kwh": 0.09,
      "wacc": 0.0595,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.17,
      "electricity": 1.03,
      "site_grid": 1.29,
      "operations": 6.54,
      "total": 32.03,
      "electricity_usd_2026_kwh": 0.09,
      "wacc": 0.0595,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.4,
      "electricity": 2.23,
      "site_grid": 2.86,
      "operations": 7.93,
      "total": 52.42,
      "electricity_usd_2026_kwh": 0.09,
      "wacc": 0.0595,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.64,
      "electricity": 2.8,
      "site_grid": 2.76,
      "operations": 15.22,
      "total": 70.43,
      "electricity_usd_2026_kwh": 0.09,
      "wacc": 0.0595,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.17,
      "electricity": 5.24,
      "site_grid": 6.33,
      "operations": 18.84,
      "total": 117.58,
      "electricity_usd_2026_kwh": 0.09,
      "wacc": 0.0595,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.83,
      "electricity": 6.6,
      "site_grid": 6.1,
      "operations": 36.38,
      "total": 158.91,
      "electricity_usd_2026_kwh": 0.09,
      "wacc": 0.0595,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.06,
      "electricity": 0.77,
      "site_grid": 1.26,
      "operations": 3.43,
      "total": 23.51,
      "electricity_usd_2026_kwh": 0.084,
      "wacc": 0.0497,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.75,
      "electricity": 0.97,
      "site_grid": 1.23,
      "operations": 6.54,
      "total": 31.48,
      "electricity_usd_2026_kwh": 0.084,
      "wacc": 0.0497,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.69,
      "electricity": 2.08,
      "site_grid": 2.69,
      "operations": 7.93,
      "total": 51.38,
      "electricity_usd_2026_kwh": 0.084,
      "wacc": 0.0497,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.74,
      "electricity": 2.62,
      "site_grid": 2.63,
      "operations": 15.22,
      "total": 69.21,
      "electricity_usd_2026_kwh": 0.084,
      "wacc": 0.0497,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.59,
      "electricity": 4.89,
      "site_grid": 5.95,
      "operations": 18.84,
      "total": 115.27,
      "electricity_usd_2026_kwh": 0.084,
      "wacc": 0.0497,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.84,
      "electricity": 6.16,
      "site_grid": 5.81,
      "operations": 36.38,
      "total": 156.19,
      "electricity_usd_2026_kwh": 0.084,
      "wacc": 0.0497,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.24,
      "electricity": 0.8,
      "site_grid": 1.32,
      "operations": 3.43,
      "total": 23.79,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0552,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.98,
      "electricity": 1.01,
      "site_grid": 1.27,
      "operations": 6.54,
      "total": 31.81,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0552,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.09,
      "electricity": 2.18,
      "site_grid": 2.82,
      "operations": 7.93,
      "total": 52.01,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0552,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.25,
      "electricity": 2.75,
      "site_grid": 2.73,
      "operations": 15.22,
      "total": 69.95,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0552,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.47,
      "electricity": 5.13,
      "site_grid": 6.24,
      "operations": 18.84,
      "total": 116.68,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0552,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.95,
      "electricity": 6.47,
      "site_grid": 6.04,
      "operations": 36.38,
      "total": 157.84,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0552,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.31,
      "electricity": 0.8,
      "site_grid": 1.35,
      "operations": 3.43,
      "total": 23.89,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0571,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.07,
      "electricity": 1.01,
      "site_grid": 1.31,
      "operations": 6.54,
      "total": 31.92,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0571,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.22,
      "electricity": 2.18,
      "site_grid": 2.9,
      "operations": 7.93,
      "total": 52.23,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0571,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.42,
      "electricity": 2.75,
      "site_grid": 2.8,
      "operations": 15.22,
      "total": 70.19,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0571,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.78,
      "electricity": 5.13,
      "site_grid": 6.42,
      "operations": 18.84,
      "total": 117.16,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0571,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.33,
      "electricity": 6.47,
      "site_grid": 6.2,
      "operations": 36.38,
      "total": 158.38,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0571,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.17,
      "electricity": 0.65,
      "site_grid": 1.34,
      "operations": 3.43,
      "total": 23.59,
      "electricity_usd_2026_kwh": 0.0711,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.89,
      "electricity": 0.82,
      "site_grid": 1.3,
      "operations": 6.54,
      "total": 31.55,
      "electricity_usd_2026_kwh": 0.0711,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.93,
      "electricity": 1.76,
      "site_grid": 2.87,
      "operations": 7.93,
      "total": 51.49,
      "electricity_usd_2026_kwh": 0.0711,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.05,
      "electricity": 2.21,
      "site_grid": 2.79,
      "operations": 15.22,
      "total": 69.28,
      "electricity_usd_2026_kwh": 0.0711,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.13,
      "electricity": 4.14,
      "site_grid": 6.36,
      "operations": 18.84,
      "total": 115.46,
      "electricity_usd_2026_kwh": 0.0711,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.52,
      "electricity": 5.22,
      "site_grid": 6.17,
      "operations": 36.38,
      "total": 156.29,
      "electricity_usd_2026_kwh": 0.0711,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.07,
      "electricity": 0.97,
      "site_grid": 1.3,
      "operations": 3.43,
      "total": 23.77,
      "electricity_usd_2026_kwh": 0.1058,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.77,
      "electricity": 1.22,
      "site_grid": 1.27,
      "operations": 6.54,
      "total": 31.79,
      "electricity_usd_2026_kwh": 0.1058,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.71,
      "electricity": 2.62,
      "site_grid": 2.8,
      "operations": 7.93,
      "total": 52.05,
      "electricity_usd_2026_kwh": 0.1058,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.78,
      "electricity": 3.3,
      "site_grid": 2.73,
      "operations": 15.22,
      "total": 70.02,
      "electricity_usd_2026_kwh": 0.1058,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.64,
      "electricity": 6.16,
      "site_grid": 6.18,
      "operations": 18.84,
      "total": 116.82,
      "electricity_usd_2026_kwh": 0.1058,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.91,
      "electricity": 7.77,
      "site_grid": 6.03,
      "operations": 36.38,
      "total": 158.08,
      "electricity_usd_2026_kwh": 0.1058,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.24,
      "electricity": 1.11,
      "site_grid": 1.35,
      "operations": 3.43,
      "total": 24.12,
      "electricity_usd_2026_kwh": 0.1211,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.98,
      "electricity": 1.39,
      "site_grid": 1.31,
      "operations": 6.54,
      "total": 32.22,
      "electricity_usd_2026_kwh": 0.1211,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.07,
      "electricity": 3.0,
      "site_grid": 2.9,
      "operations": 7.93,
      "total": 52.9,
      "electricity_usd_2026_kwh": 0.1211,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.23,
      "electricity": 3.78,
      "site_grid": 2.81,
      "operations": 15.22,
      "total": 71.04,
      "electricity_usd_2026_kwh": 0.1211,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.44,
      "electricity": 7.06,
      "site_grid": 6.42,
      "operations": 18.84,
      "total": 118.75,
      "electricity_usd_2026_kwh": 0.1211,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.91,
      "electricity": 8.89,
      "site_grid": 6.22,
      "operations": 36.38,
      "total": 160.4,
      "electricity_usd_2026_kwh": 0.1211,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.43,
      "electricity": 0.83,
      "site_grid": 1.44,
      "operations": 3.43,
      "total": 24.13,
      "electricity_usd_2026_kwh": 0.0909,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.23,
      "electricity": 1.04,
      "site_grid": 1.39,
      "operations": 6.54,
      "total": 32.19,
      "electricity_usd_2026_kwh": 0.0909,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.5,
      "electricity": 2.25,
      "site_grid": 3.09,
      "operations": 7.93,
      "total": 52.76,
      "electricity_usd_2026_kwh": 0.0909,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.76,
      "electricity": 2.83,
      "site_grid": 2.97,
      "operations": 15.22,
      "total": 70.79,
      "electricity_usd_2026_kwh": 0.0909,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.38,
      "electricity": 5.29,
      "site_grid": 6.83,
      "operations": 18.84,
      "total": 118.34,
      "electricity_usd_2026_kwh": 0.0909,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.09,
      "electricity": 6.67,
      "site_grid": 6.57,
      "operations": 36.38,
      "total": 159.71,
      "electricity_usd_2026_kwh": 0.0909,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.17,
      "electricity": 0.77,
      "site_grid": 1.42,
      "operations": 3.43,
      "total": 23.79,
      "electricity_usd_2026_kwh": 0.084,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.9,
      "electricity": 0.97,
      "site_grid": 1.38,
      "operations": 6.54,
      "total": 31.78,
      "electricity_usd_2026_kwh": 0.084,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.93,
      "electricity": 2.08,
      "site_grid": 3.05,
      "operations": 7.93,
      "total": 51.99,
      "electricity_usd_2026_kwh": 0.084,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.05,
      "electricity": 2.62,
      "site_grid": 2.96,
      "operations": 15.22,
      "total": 69.86,
      "electricity_usd_2026_kwh": 0.084,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.13,
      "electricity": 4.89,
      "site_grid": 6.74,
      "operations": 18.84,
      "total": 116.6,
      "electricity_usd_2026_kwh": 0.084,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.52,
      "electricity": 6.16,
      "site_grid": 6.55,
      "operations": 36.38,
      "total": 157.62,
      "electricity_usd_2026_kwh": 0.084,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.75,
      "electricity": 0.97,
      "site_grid": 1.32,
      "operations": 3.43,
      "total": 23.47,
      "electricity_usd_2026_kwh": 0.1059,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.36,
      "electricity": 1.22,
      "site_grid": 1.31,
      "operations": 6.54,
      "total": 31.43,
      "electricity_usd_2026_kwh": 0.1059,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.02,
      "electricity": 2.62,
      "site_grid": 2.84,
      "operations": 7.93,
      "total": 51.41,
      "electricity_usd_2026_kwh": 0.1059,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.91,
      "electricity": 3.3,
      "site_grid": 2.8,
      "operations": 15.22,
      "total": 69.24,
      "electricity_usd_2026_kwh": 0.1059,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.11,
      "electricity": 6.17,
      "site_grid": 6.28,
      "operations": 18.84,
      "total": 115.4,
      "electricity_usd_2026_kwh": 0.1059,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.0,
      "electricity": 7.78,
      "site_grid": 6.2,
      "operations": 36.38,
      "total": 156.36,
      "electricity_usd_2026_kwh": 0.1059,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.93,
      "electricity": 0.83,
      "site_grid": 1.39,
      "operations": 3.43,
      "total": 23.58,
      "electricity_usd_2026_kwh": 0.0906,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.6,
      "electricity": 1.04,
      "site_grid": 1.36,
      "operations": 6.54,
      "total": 31.54,
      "electricity_usd_2026_kwh": 0.0906,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.43,
      "electricity": 2.24,
      "site_grid": 2.97,
      "operations": 7.93,
      "total": 51.57,
      "electricity_usd_2026_kwh": 0.0906,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.42,
      "electricity": 2.82,
      "site_grid": 2.91,
      "operations": 15.22,
      "total": 69.38,
      "electricity_usd_2026_kwh": 0.0906,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.01,
      "electricity": 5.28,
      "site_grid": 6.57,
      "operations": 18.84,
      "total": 115.69,
      "electricity_usd_2026_kwh": 0.0906,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.12,
      "electricity": 6.65,
      "site_grid": 6.44,
      "operations": 36.38,
      "total": 156.59,
      "electricity_usd_2026_kwh": 0.0906,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.45,
      "electricity": 0.84,
      "site_grid": 1.74,
      "operations": 3.43,
      "total": 24.46,
      "electricity_usd_2026_kwh": 0.0925,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.24,
      "electricity": 1.06,
      "site_grid": 1.67,
      "operations": 6.54,
      "total": 32.52,
      "electricity_usd_2026_kwh": 0.0925,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.53,
      "electricity": 2.29,
      "site_grid": 3.73,
      "operations": 7.93,
      "total": 53.47,
      "electricity_usd_2026_kwh": 0.0925,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.8,
      "electricity": 2.88,
      "site_grid": 3.58,
      "operations": 15.22,
      "total": 71.49,
      "electricity_usd_2026_kwh": 0.0925,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.45,
      "electricity": 5.39,
      "site_grid": 8.25,
      "operations": 18.84,
      "total": 119.92,
      "electricity_usd_2026_kwh": 0.0925,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.17,
      "electricity": 6.79,
      "site_grid": 7.93,
      "operations": 36.38,
      "total": 161.27,
      "electricity_usd_2026_kwh": 0.0925,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.8,
      "electricity": 0.85,
      "site_grid": 1.92,
      "operations": 3.43,
      "total": 25.0,
      "electricity_usd_2026_kwh": 0.0931,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.68,
      "electricity": 1.07,
      "site_grid": 1.82,
      "operations": 6.54,
      "total": 33.11,
      "electricity_usd_2026_kwh": 0.0931,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.27,
      "electricity": 2.3,
      "site_grid": 4.12,
      "operations": 7.93,
      "total": 54.62,
      "electricity_usd_2026_kwh": 0.0931,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.73,
      "electricity": 2.9,
      "site_grid": 3.91,
      "operations": 15.22,
      "total": 72.76,
      "electricity_usd_2026_kwh": 0.0931,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.09,
      "electricity": 5.43,
      "site_grid": 9.11,
      "operations": 18.84,
      "total": 122.46,
      "electricity_usd_2026_kwh": 0.0931,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.23,
      "electricity": 6.84,
      "site_grid": 8.65,
      "operations": 36.38,
      "total": 164.09,
      "electricity_usd_2026_kwh": 0.0931,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.88,
      "electricity": 0.95,
      "site_grid": 1.89,
      "operations": 3.43,
      "total": 25.15,
      "electricity_usd_2026_kwh": 0.1043,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.78,
      "electricity": 1.2,
      "site_grid": 1.79,
      "operations": 6.54,
      "total": 33.31,
      "electricity_usd_2026_kwh": 0.1043,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.45,
      "electricity": 2.58,
      "site_grid": 4.05,
      "operations": 7.93,
      "total": 55.01,
      "electricity_usd_2026_kwh": 0.1043,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.96,
      "electricity": 3.25,
      "site_grid": 3.83,
      "operations": 15.22,
      "total": 73.27,
      "electricity_usd_2026_kwh": 0.1043,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.5,
      "electricity": 6.08,
      "site_grid": 8.96,
      "operations": 18.84,
      "total": 123.37,
      "electricity_usd_2026_kwh": 0.1043,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.74,
      "electricity": 7.66,
      "site_grid": 8.48,
      "operations": 36.38,
      "total": 165.26,
      "electricity_usd_2026_kwh": 0.1043,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.91,
      "electricity": 0.78,
      "site_grid": 1.88,
      "operations": 3.43,
      "total": 25.0,
      "electricity_usd_2026_kwh": 0.086,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.82,
      "electricity": 0.99,
      "site_grid": 1.77,
      "operations": 6.54,
      "total": 33.12,
      "electricity_usd_2026_kwh": 0.086,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.52,
      "electricity": 2.13,
      "site_grid": 4.02,
      "operations": 7.93,
      "total": 54.59,
      "electricity_usd_2026_kwh": 0.086,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.04,
      "electricity": 2.68,
      "site_grid": 3.8,
      "operations": 15.22,
      "total": 72.74,
      "electricity_usd_2026_kwh": 0.086,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.64,
      "electricity": 5.01,
      "site_grid": 8.9,
      "operations": 18.84,
      "total": 122.38,
      "electricity_usd_2026_kwh": 0.086,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.91,
      "electricity": 6.31,
      "site_grid": 8.41,
      "operations": 36.38,
      "total": 164.01,
      "electricity_usd_2026_kwh": 0.086,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.92,
      "electricity": 0.78,
      "site_grid": 1.89,
      "operations": 3.43,
      "total": 25.02,
      "electricity_usd_2026_kwh": 0.086,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.84,
      "electricity": 0.99,
      "site_grid": 1.78,
      "operations": 6.54,
      "total": 33.15,
      "electricity_usd_2026_kwh": 0.086,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.54,
      "electricity": 2.13,
      "site_grid": 4.04,
      "operations": 7.93,
      "total": 54.64,
      "electricity_usd_2026_kwh": 0.086,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 51.07,
      "electricity": 2.68,
      "site_grid": 3.82,
      "operations": 15.22,
      "total": 72.8,
      "electricity_usd_2026_kwh": 0.086,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.7,
      "electricity": 5.01,
      "site_grid": 8.94,
      "operations": 18.84,
      "total": 122.48,
      "electricity_usd_2026_kwh": 0.086,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.99,
      "electricity": 6.31,
      "site_grid": 8.45,
      "operations": 36.38,
      "total": 164.13,
      "electricity_usd_2026_kwh": 0.086,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.94,
      "electricity": 1.8,
      "site_grid": 1.27,
      "operations": 3.3,
      "total": 23.31,
      "electricity_usd_2026_kwh": 0.1978,
      "wacc": 0.0518,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.29,
      "electricity": 2.29,
      "site_grid": 1.23,
      "operations": 6.58,
      "total": 31.38,
      "electricity_usd_2026_kwh": 0.1978,
      "wacc": 0.0518,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.29,
      "electricity": 4.88,
      "site_grid": 2.73,
      "operations": 7.65,
      "total": 51.55,
      "electricity_usd_2026_kwh": 0.1978,
      "wacc": 0.0518,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.61,
      "electricity": 6.2,
      "site_grid": 2.64,
      "operations": 15.3,
      "total": 69.75,
      "electricity_usd_2026_kwh": 0.1978,
      "wacc": 0.0518,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.28,
      "electricity": 11.5,
      "site_grid": 6.03,
      "operations": 18.22,
      "total": 116.03,
      "electricity_usd_2026_kwh": 0.1978,
      "wacc": 0.0518,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.91,
      "electricity": 14.59,
      "site_grid": 5.84,
      "operations": 36.54,
      "total": 157.88,
      "electricity_usd_2026_kwh": 0.1978,
      "wacc": 0.0518,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.8,
      "electricity": 1.88,
      "site_grid": 1.22,
      "operations": 3.3,
      "total": 23.19,
      "electricity_usd_2026_kwh": 0.206,
      "wacc": 0.0475,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.12,
      "electricity": 2.38,
      "site_grid": 1.19,
      "operations": 6.58,
      "total": 31.26,
      "electricity_usd_2026_kwh": 0.206,
      "wacc": 0.0475,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.99,
      "electricity": 5.09,
      "site_grid": 2.61,
      "operations": 7.65,
      "total": 51.34,
      "electricity_usd_2026_kwh": 0.206,
      "wacc": 0.0475,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.24,
      "electricity": 6.45,
      "site_grid": 2.54,
      "operations": 15.3,
      "total": 69.54,
      "electricity_usd_2026_kwh": 0.206,
      "wacc": 0.0475,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.63,
      "electricity": 11.98,
      "site_grid": 5.77,
      "operations": 18.22,
      "total": 115.6,
      "electricity_usd_2026_kwh": 0.206,
      "wacc": 0.0475,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.09,
      "electricity": 15.2,
      "site_grid": 5.62,
      "operations": 36.54,
      "total": 157.46,
      "electricity_usd_2026_kwh": 0.206,
      "wacc": 0.0475,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.56,
      "electricity": 1.5,
      "site_grid": 1.16,
      "operations": 3.3,
      "total": 22.52,
      "electricity_usd_2026_kwh": 0.165,
      "wacc": 0.0377,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.73,
      "electricity": 1.91,
      "site_grid": 1.13,
      "operations": 6.58,
      "total": 30.34,
      "electricity_usd_2026_kwh": 0.165,
      "wacc": 0.0377,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.48,
      "electricity": 4.08,
      "site_grid": 2.49,
      "operations": 7.65,
      "total": 49.69,
      "electricity_usd_2026_kwh": 0.165,
      "wacc": 0.0377,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.41,
      "electricity": 5.17,
      "site_grid": 2.42,
      "operations": 15.3,
      "total": 67.3,
      "electricity_usd_2026_kwh": 0.165,
      "wacc": 0.0377,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.5,
      "electricity": 9.6,
      "site_grid": 5.5,
      "operations": 18.22,
      "total": 111.81,
      "electricity_usd_2026_kwh": 0.165,
      "wacc": 0.0377,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.26,
      "electricity": 12.18,
      "site_grid": 5.34,
      "operations": 36.54,
      "total": 152.32,
      "electricity_usd_2026_kwh": 0.165,
      "wacc": 0.0377,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.66,
      "electricity": 1.57,
      "site_grid": 1.2,
      "operations": 3.3,
      "total": 22.73,
      "electricity_usd_2026_kwh": 0.1727,
      "wacc": 0.0432,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.95,
      "electricity": 2.0,
      "site_grid": 1.17,
      "operations": 6.58,
      "total": 30.69,
      "electricity_usd_2026_kwh": 0.1727,
      "wacc": 0.0432,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.7,
      "electricity": 4.27,
      "site_grid": 2.57,
      "operations": 7.65,
      "total": 50.18,
      "electricity_usd_2026_kwh": 0.1727,
      "wacc": 0.0432,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.88,
      "electricity": 5.41,
      "site_grid": 2.51,
      "operations": 15.3,
      "total": 68.1,
      "electricity_usd_2026_kwh": 0.1727,
      "wacc": 0.0432,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.98,
      "electricity": 10.04,
      "site_grid": 5.68,
      "operations": 18.22,
      "total": 112.91,
      "electricity_usd_2026_kwh": 0.1727,
      "wacc": 0.0432,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.28,
      "electricity": 12.74,
      "site_grid": 5.56,
      "operations": 36.54,
      "total": 154.13,
      "electricity_usd_2026_kwh": 0.1727,
      "wacc": 0.0432,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.72,
      "electricity": 1.36,
      "site_grid": 1.23,
      "operations": 3.3,
      "total": 22.61,
      "electricity_usd_2026_kwh": 0.149,
      "wacc": 0.0451,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.02,
      "electricity": 1.72,
      "site_grid": 1.21,
      "operations": 6.58,
      "total": 30.52,
      "electricity_usd_2026_kwh": 0.149,
      "wacc": 0.0451,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.83,
      "electricity": 3.68,
      "site_grid": 2.64,
      "operations": 7.65,
      "total": 49.8,
      "electricity_usd_2026_kwh": 0.149,
      "wacc": 0.0451,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.04,
      "electricity": 4.67,
      "site_grid": 2.58,
      "operations": 15.3,
      "total": 67.59,
      "electricity_usd_2026_kwh": 0.149,
      "wacc": 0.0451,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.26,
      "electricity": 8.67,
      "site_grid": 5.84,
      "operations": 18.22,
      "total": 111.99,
      "electricity_usd_2026_kwh": 0.149,
      "wacc": 0.0451,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.64,
      "electricity": 10.99,
      "site_grid": 5.71,
      "operations": 36.54,
      "total": 152.89,
      "electricity_usd_2026_kwh": 0.149,
      "wacc": 0.0451,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.59,
      "electricity": 1.03,
      "site_grid": 1.22,
      "operations": 3.3,
      "total": 22.14,
      "electricity_usd_2026_kwh": 0.1126,
      "wacc": 0.0411,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.86,
      "electricity": 1.3,
      "site_grid": 1.2,
      "operations": 6.58,
      "total": 29.94,
      "electricity_usd_2026_kwh": 0.1126,
      "wacc": 0.0411,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.55,
      "electricity": 2.78,
      "site_grid": 2.61,
      "operations": 7.65,
      "total": 48.6,
      "electricity_usd_2026_kwh": 0.1126,
      "wacc": 0.0411,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.7,
      "electricity": 3.53,
      "site_grid": 2.57,
      "operations": 15.3,
      "total": 66.1,
      "electricity_usd_2026_kwh": 0.1126,
      "wacc": 0.0411,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.66,
      "electricity": 6.55,
      "site_grid": 5.78,
      "operations": 18.22,
      "total": 109.21,
      "electricity_usd_2026_kwh": 0.1126,
      "wacc": 0.0411,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.88,
      "electricity": 8.31,
      "site_grid": 5.68,
      "operations": 36.54,
      "total": 149.42,
      "electricity_usd_2026_kwh": 0.1126,
      "wacc": 0.0411,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.56,
      "electricity": 1.08,
      "site_grid": 1.2,
      "operations": 3.3,
      "total": 22.14,
      "electricity_usd_2026_kwh": 0.1187,
      "wacc": 0.0381,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.74,
      "electricity": 1.37,
      "site_grid": 1.17,
      "operations": 6.58,
      "total": 29.86,
      "electricity_usd_2026_kwh": 0.1187,
      "wacc": 0.0381,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.48,
      "electricity": 2.93,
      "site_grid": 2.58,
      "operations": 7.65,
      "total": 48.64,
      "electricity_usd_2026_kwh": 0.1187,
      "wacc": 0.0381,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.44,
      "electricity": 3.72,
      "site_grid": 2.51,
      "operations": 15.3,
      "total": 65.97,
      "electricity_usd_2026_kwh": 0.1187,
      "wacc": 0.0381,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.5,
      "electricity": 6.9,
      "site_grid": 5.7,
      "operations": 18.22,
      "total": 109.32,
      "electricity_usd_2026_kwh": 0.1187,
      "wacc": 0.0381,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.32,
      "electricity": 8.76,
      "site_grid": 5.55,
      "operations": 36.54,
      "total": 149.17,
      "electricity_usd_2026_kwh": 0.1187,
      "wacc": 0.0381,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.66,
      "electricity": 0.98,
      "site_grid": 1.23,
      "operations": 3.3,
      "total": 22.17,
      "electricity_usd_2026_kwh": 0.1077,
      "wacc": 0.043,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.94,
      "electricity": 1.24,
      "site_grid": 1.21,
      "operations": 6.58,
      "total": 29.97,
      "electricity_usd_2026_kwh": 0.1077,
      "wacc": 0.043,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.68,
      "electricity": 2.66,
      "site_grid": 2.64,
      "operations": 7.65,
      "total": 48.64,
      "electricity_usd_2026_kwh": 0.1077,
      "wacc": 0.043,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.86,
      "electricity": 3.37,
      "site_grid": 2.59,
      "operations": 15.3,
      "total": 66.13,
      "electricity_usd_2026_kwh": 0.1077,
      "wacc": 0.043,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.95,
      "electricity": 6.27,
      "site_grid": 5.85,
      "operations": 18.22,
      "total": 109.27,
      "electricity_usd_2026_kwh": 0.1077,
      "wacc": 0.043,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.24,
      "electricity": 7.95,
      "site_grid": 5.73,
      "operations": 36.54,
      "total": 149.46,
      "electricity_usd_2026_kwh": 0.1077,
      "wacc": 0.043,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.84,
      "electricity": 1.17,
      "site_grid": 1.31,
      "operations": 3.3,
      "total": 22.62,
      "electricity_usd_2026_kwh": 0.1283,
      "wacc": 0.0488,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.17,
      "electricity": 1.48,
      "site_grid": 1.28,
      "operations": 6.58,
      "total": 30.5,
      "electricity_usd_2026_kwh": 0.1283,
      "wacc": 0.0488,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.08,
      "electricity": 3.17,
      "site_grid": 2.82,
      "operations": 7.65,
      "total": 49.71,
      "electricity_usd_2026_kwh": 0.1283,
      "wacc": 0.0488,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.35,
      "electricity": 4.02,
      "site_grid": 2.74,
      "operations": 15.3,
      "total": 67.41,
      "electricity_usd_2026_kwh": 0.1283,
      "wacc": 0.0488,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.82,
      "electricity": 7.46,
      "site_grid": 6.23,
      "operations": 18.22,
      "total": 111.73,
      "electricity_usd_2026_kwh": 0.1283,
      "wacc": 0.0488,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.34,
      "electricity": 9.46,
      "site_grid": 6.06,
      "operations": 36.54,
      "total": 152.4,
      "electricity_usd_2026_kwh": 0.1283,
      "wacc": 0.0488,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.6,
      "electricity": 1.05,
      "site_grid": 1.29,
      "operations": 3.3,
      "total": 22.24,
      "electricity_usd_2026_kwh": 0.115,
      "wacc": 0.0411,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.86,
      "electricity": 1.33,
      "site_grid": 1.27,
      "operations": 6.58,
      "total": 30.04,
      "electricity_usd_2026_kwh": 0.115,
      "wacc": 0.0411,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.56,
      "electricity": 2.84,
      "site_grid": 2.77,
      "operations": 7.65,
      "total": 48.82,
      "electricity_usd_2026_kwh": 0.115,
      "wacc": 0.0411,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.7,
      "electricity": 3.6,
      "site_grid": 2.73,
      "operations": 15.3,
      "total": 66.33,
      "electricity_usd_2026_kwh": 0.115,
      "wacc": 0.0411,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.66,
      "electricity": 6.69,
      "site_grid": 6.14,
      "operations": 18.22,
      "total": 109.7,
      "electricity_usd_2026_kwh": 0.115,
      "wacc": 0.0411,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.89,
      "electricity": 8.48,
      "site_grid": 6.03,
      "operations": 36.54,
      "total": 149.94,
      "electricity_usd_2026_kwh": 0.115,
      "wacc": 0.0411,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.56,
      "electricity": 0.66,
      "site_grid": 1.31,
      "operations": 3.3,
      "total": 21.82,
      "electricity_usd_2026_kwh": 0.0723,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.62,
      "electricity": 0.83,
      "site_grid": 1.25,
      "operations": 6.58,
      "total": 29.28,
      "electricity_usd_2026_kwh": 0.0723,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.48,
      "electricity": 1.78,
      "site_grid": 2.8,
      "operations": 7.65,
      "total": 47.72,
      "electricity_usd_2026_kwh": 0.0723,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.18,
      "electricity": 2.26,
      "site_grid": 2.68,
      "operations": 15.3,
      "total": 64.43,
      "electricity_usd_2026_kwh": 0.0723,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.5,
      "electricity": 4.2,
      "site_grid": 6.19,
      "operations": 18.22,
      "total": 107.11,
      "electricity_usd_2026_kwh": 0.0723,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 97.75,
      "electricity": 5.33,
      "site_grid": 5.92,
      "operations": 36.54,
      "total": 145.54,
      "electricity_usd_2026_kwh": 0.0723,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.56,
      "electricity": 1.32,
      "site_grid": 1.31,
      "operations": 3.3,
      "total": 22.49,
      "electricity_usd_2026_kwh": 0.1451,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.62,
      "electricity": 1.68,
      "site_grid": 1.25,
      "operations": 6.58,
      "total": 30.13,
      "electricity_usd_2026_kwh": 0.1451,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.48,
      "electricity": 3.58,
      "site_grid": 2.81,
      "operations": 7.65,
      "total": 49.53,
      "electricity_usd_2026_kwh": 0.1451,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.18,
      "electricity": 4.55,
      "site_grid": 2.69,
      "operations": 15.3,
      "total": 66.72,
      "electricity_usd_2026_kwh": 0.1451,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.5,
      "electricity": 8.44,
      "site_grid": 6.22,
      "operations": 18.22,
      "total": 111.38,
      "electricity_usd_2026_kwh": 0.1451,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 97.75,
      "electricity": 10.71,
      "site_grid": 5.95,
      "operations": 36.54,
      "total": 150.94,
      "electricity_usd_2026_kwh": 0.1451,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.85,
      "electricity": 1.95,
      "site_grid": 1.59,
      "operations": 3.3,
      "total": 23.69,
      "electricity_usd_2026_kwh": 0.2139,
      "wacc": 0.0492,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.18,
      "electricity": 2.47,
      "site_grid": 1.54,
      "operations": 6.58,
      "total": 31.77,
      "electricity_usd_2026_kwh": 0.2139,
      "wacc": 0.0492,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.11,
      "electricity": 5.28,
      "site_grid": 3.4,
      "operations": 7.65,
      "total": 52.44,
      "electricity_usd_2026_kwh": 0.2139,
      "wacc": 0.0492,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.39,
      "electricity": 6.7,
      "site_grid": 3.3,
      "operations": 15.3,
      "total": 70.7,
      "electricity_usd_2026_kwh": 0.2139,
      "wacc": 0.0492,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.88,
      "electricity": 12.44,
      "site_grid": 7.52,
      "operations": 18.22,
      "total": 118.06,
      "electricity_usd_2026_kwh": 0.2139,
      "wacc": 0.0492,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.41,
      "electricity": 15.78,
      "site_grid": 7.31,
      "operations": 36.54,
      "total": 160.05,
      "electricity_usd_2026_kwh": 0.2139,
      "wacc": 0.0492,
      "construction_real_factor": 1.0102,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.17,
      "electricity": 1.05,
      "site_grid": 1.76,
      "operations": 3.3,
      "total": 23.28,
      "electricity_usd_2026_kwh": 0.1151,
      "wacc": 0.0593,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.59,
      "electricity": 1.33,
      "site_grid": 1.69,
      "operations": 6.58,
      "total": 31.18,
      "electricity_usd_2026_kwh": 0.1151,
      "wacc": 0.0593,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.8,
      "electricity": 2.84,
      "site_grid": 3.76,
      "operations": 7.65,
      "total": 51.06,
      "electricity_usd_2026_kwh": 0.1151,
      "wacc": 0.0593,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.25,
      "electricity": 3.61,
      "site_grid": 3.61,
      "operations": 15.3,
      "total": 68.77,
      "electricity_usd_2026_kwh": 0.1151,
      "wacc": 0.0593,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.41,
      "electricity": 6.7,
      "site_grid": 8.33,
      "operations": 18.22,
      "total": 114.65,
      "electricity_usd_2026_kwh": 0.1151,
      "wacc": 0.0593,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.32,
      "electricity": 8.5,
      "site_grid": 7.99,
      "operations": 36.54,
      "total": 155.34,
      "electricity_usd_2026_kwh": 0.1151,
      "wacc": 0.0593,
      "construction_real_factor": 1.04368,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.25,
      "electricity": 0.81,
      "site_grid": 1.73,
      "operations": 3.3,
      "total": 23.09,
      "electricity_usd_2026_kwh": 0.0889,
      "wacc": 0.0618,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.69,
      "electricity": 1.03,
      "site_grid": 1.65,
      "operations": 6.58,
      "total": 30.94,
      "electricity_usd_2026_kwh": 0.0889,
      "wacc": 0.0618,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.97,
      "electricity": 2.2,
      "site_grid": 3.71,
      "operations": 7.65,
      "total": 50.52,
      "electricity_usd_2026_kwh": 0.0889,
      "wacc": 0.0618,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.46,
      "electricity": 2.79,
      "site_grid": 3.54,
      "operations": 15.3,
      "total": 68.09,
      "electricity_usd_2026_kwh": 0.0889,
      "wacc": 0.0618,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.79,
      "electricity": 5.17,
      "site_grid": 8.2,
      "operations": 18.22,
      "total": 113.37,
      "electricity_usd_2026_kwh": 0.0889,
      "wacc": 0.0618,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.79,
      "electricity": 6.56,
      "site_grid": 7.84,
      "operations": 36.54,
      "total": 153.73,
      "electricity_usd_2026_kwh": 0.0889,
      "wacc": 0.0618,
      "construction_real_factor": 1.01036,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.28,
      "electricity": 0.87,
      "site_grid": 1.72,
      "operations": 3.3,
      "total": 23.17,
      "electricity_usd_2026_kwh": 0.0955,
      "wacc": 0.0626,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.72,
      "electricity": 1.1,
      "site_grid": 1.64,
      "operations": 6.58,
      "total": 31.04,
      "electricity_usd_2026_kwh": 0.0955,
      "wacc": 0.0626,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.03,
      "electricity": 2.36,
      "site_grid": 3.68,
      "operations": 7.65,
      "total": 50.72,
      "electricity_usd_2026_kwh": 0.0955,
      "wacc": 0.0626,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.53,
      "electricity": 2.99,
      "site_grid": 3.52,
      "operations": 15.3,
      "total": 68.35,
      "electricity_usd_2026_kwh": 0.0955,
      "wacc": 0.0626,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.91,
      "electricity": 5.56,
      "site_grid": 8.14,
      "operations": 18.22,
      "total": 113.83,
      "electricity_usd_2026_kwh": 0.0955,
      "wacc": 0.0626,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.95,
      "electricity": 7.05,
      "site_grid": 7.78,
      "operations": 36.54,
      "total": 154.32,
      "electricity_usd_2026_kwh": 0.0955,
      "wacc": 0.0626,
      "construction_real_factor": 0.99742,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.29,
      "electricity": 0.86,
      "site_grid": 1.73,
      "operations": 3.3,
      "total": 23.18,
      "electricity_usd_2026_kwh": 0.0948,
      "wacc": 0.063,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.73,
      "electricity": 1.1,
      "site_grid": 1.65,
      "operations": 6.58,
      "total": 31.05,
      "electricity_usd_2026_kwh": 0.0948,
      "wacc": 0.063,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.05,
      "electricity": 2.34,
      "site_grid": 3.7,
      "operations": 7.65,
      "total": 50.74,
      "electricity_usd_2026_kwh": 0.0948,
      "wacc": 0.063,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.57,
      "electricity": 2.97,
      "site_grid": 3.53,
      "operations": 15.3,
      "total": 68.37,
      "electricity_usd_2026_kwh": 0.0948,
      "wacc": 0.063,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.97,
      "electricity": 5.52,
      "site_grid": 8.18,
      "operations": 18.22,
      "total": 113.89,
      "electricity_usd_2026_kwh": 0.0948,
      "wacc": 0.063,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.02,
      "electricity": 7.0,
      "site_grid": 7.81,
      "operations": 36.54,
      "total": 154.37,
      "electricity_usd_2026_kwh": 0.0948,
      "wacc": 0.063,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.11,
      "electricity": 2.33,
      "site_grid": 1.41,
      "operations": 3.42,
      "total": 24.27,
      "electricity_usd_2026_kwh": 0.2515,
      "wacc": 0.0468,
      "construction_real_factor": 0.79525,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.5,
      "electricity": 2.99,
      "site_grid": 1.5,
      "operations": 6.98,
      "total": 32.97,
      "electricity_usd_2026_kwh": 0.2515,
      "wacc": 0.0468,
      "construction_real_factor": 0.79525,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.65,
      "electricity": 6.33,
      "site_grid": 3.02,
      "operations": 7.91,
      "total": 53.91,
      "electricity_usd_2026_kwh": 0.2515,
      "wacc": 0.0468,
      "construction_real_factor": 0.79525,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.07,
      "electricity": 8.1,
      "site_grid": 3.21,
      "operations": 16.16,
      "total": 73.54,
      "electricity_usd_2026_kwh": 0.2515,
      "wacc": 0.0468,
      "construction_real_factor": 0.79525,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.09,
      "electricity": 14.9,
      "site_grid": 6.69,
      "operations": 18.78,
      "total": 121.45,
      "electricity_usd_2026_kwh": 0.2515,
      "wacc": 0.0468,
      "construction_real_factor": 0.79525,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.93,
      "electricity": 19.07,
      "site_grid": 7.1,
      "operations": 38.45,
      "total": 166.54,
      "electricity_usd_2026_kwh": 0.2515,
      "wacc": 0.0468,
      "construction_real_factor": 0.79525,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.97,
      "electricity": 2.54,
      "site_grid": 1.35,
      "operations": 3.42,
      "total": 24.27,
      "electricity_usd_2026_kwh": 0.2735,
      "wacc": 0.0425,
      "construction_real_factor": 0.78459,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.33,
      "electricity": 3.25,
      "site_grid": 1.44,
      "operations": 6.98,
      "total": 33.0,
      "electricity_usd_2026_kwh": 0.2735,
      "wacc": 0.0425,
      "construction_real_factor": 0.78459,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.35,
      "electricity": 6.88,
      "site_grid": 2.89,
      "operations": 7.91,
      "total": 54.03,
      "electricity_usd_2026_kwh": 0.2735,
      "wacc": 0.0425,
      "construction_real_factor": 0.78459,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.7,
      "electricity": 8.8,
      "site_grid": 3.09,
      "operations": 16.16,
      "total": 73.76,
      "electricity_usd_2026_kwh": 0.2735,
      "wacc": 0.0425,
      "construction_real_factor": 0.78459,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.42,
      "electricity": 16.21,
      "site_grid": 6.4,
      "operations": 18.78,
      "total": 121.8,
      "electricity_usd_2026_kwh": 0.2735,
      "wacc": 0.0425,
      "construction_real_factor": 0.78459,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.1,
      "electricity": 20.74,
      "site_grid": 6.83,
      "operations": 38.45,
      "total": 167.11,
      "electricity_usd_2026_kwh": 0.2735,
      "wacc": 0.0425,
      "construction_real_factor": 0.78459,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.89,
      "electricity": 2.37,
      "site_grid": 1.33,
      "operations": 3.42,
      "total": 24.0,
      "electricity_usd_2026_kwh": 0.2553,
      "wacc": 0.035,
      "construction_real_factor": 0.7887,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.03,
      "electricity": 3.03,
      "site_grid": 1.39,
      "operations": 6.98,
      "total": 32.42,
      "electricity_usd_2026_kwh": 0.2553,
      "wacc": 0.035,
      "construction_real_factor": 0.7887,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.18,
      "electricity": 6.42,
      "site_grid": 2.85,
      "operations": 7.91,
      "total": 53.36,
      "electricity_usd_2026_kwh": 0.2553,
      "wacc": 0.035,
      "construction_real_factor": 0.7887,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.05,
      "electricity": 8.22,
      "site_grid": 2.97,
      "operations": 16.16,
      "total": 72.4,
      "electricity_usd_2026_kwh": 0.2553,
      "wacc": 0.035,
      "construction_real_factor": 0.7887,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.04,
      "electricity": 15.13,
      "site_grid": 6.31,
      "operations": 18.78,
      "total": 120.26,
      "electricity_usd_2026_kwh": 0.2553,
      "wacc": 0.035,
      "construction_real_factor": 0.7887,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.67,
      "electricity": 19.35,
      "site_grid": 6.57,
      "operations": 38.45,
      "total": 164.04,
      "electricity_usd_2026_kwh": 0.2553,
      "wacc": 0.035,
      "construction_real_factor": 0.7887,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.89,
      "electricity": 2.49,
      "site_grid": 1.34,
      "operations": 3.42,
      "total": 24.13,
      "electricity_usd_2026_kwh": 0.268,
      "wacc": 0.0382,
      "construction_real_factor": 0.79534,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.15,
      "electricity": 3.18,
      "site_grid": 1.42,
      "operations": 6.98,
      "total": 32.74,
      "electricity_usd_2026_kwh": 0.268,
      "wacc": 0.0382,
      "construction_real_factor": 0.79534,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.18,
      "electricity": 6.74,
      "site_grid": 2.88,
      "operations": 7.91,
      "total": 53.7,
      "electricity_usd_2026_kwh": 0.268,
      "wacc": 0.0382,
      "construction_real_factor": 0.79534,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.32,
      "electricity": 8.63,
      "site_grid": 3.05,
      "operations": 16.16,
      "total": 73.17,
      "electricity_usd_2026_kwh": 0.268,
      "wacc": 0.0382,
      "construction_real_factor": 0.79534,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.04,
      "electricity": 15.88,
      "site_grid": 6.37,
      "operations": 18.78,
      "total": 121.06,
      "electricity_usd_2026_kwh": 0.268,
      "wacc": 0.0382,
      "construction_real_factor": 0.79534,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.27,
      "electricity": 20.31,
      "site_grid": 6.75,
      "operations": 38.45,
      "total": 165.79,
      "electricity_usd_2026_kwh": 0.268,
      "wacc": 0.0382,
      "construction_real_factor": 0.79534,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.89,
      "electricity": 2.49,
      "site_grid": 1.37,
      "operations": 3.42,
      "total": 24.16,
      "electricity_usd_2026_kwh": 0.2679,
      "wacc": 0.0401,
      "construction_real_factor": 0.80787,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.23,
      "electricity": 3.18,
      "site_grid": 1.46,
      "operations": 6.98,
      "total": 32.85,
      "electricity_usd_2026_kwh": 0.2679,
      "wacc": 0.0401,
      "construction_real_factor": 0.80787,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.18,
      "electricity": 6.74,
      "site_grid": 2.93,
      "operations": 7.91,
      "total": 53.76,
      "electricity_usd_2026_kwh": 0.2679,
      "wacc": 0.0401,
      "construction_real_factor": 0.80787,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.49,
      "electricity": 8.62,
      "site_grid": 3.14,
      "operations": 16.16,
      "total": 73.41,
      "electricity_usd_2026_kwh": 0.2679,
      "wacc": 0.0401,
      "construction_real_factor": 0.80787,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.05,
      "electricity": 15.87,
      "site_grid": 6.47,
      "operations": 18.78,
      "total": 121.18,
      "electricity_usd_2026_kwh": 0.2679,
      "wacc": 0.0401,
      "construction_real_factor": 0.80787,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.64,
      "electricity": 20.31,
      "site_grid": 6.94,
      "operations": 38.45,
      "total": 166.33,
      "electricity_usd_2026_kwh": 0.2679,
      "wacc": 0.0401,
      "construction_real_factor": 0.80787,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.89,
      "electricity": 2.0,
      "site_grid": 1.39,
      "operations": 3.42,
      "total": 23.7,
      "electricity_usd_2026_kwh": 0.216,
      "wacc": 0.0361,
      "construction_real_factor": 0.82253,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.07,
      "electricity": 2.57,
      "site_grid": 1.46,
      "operations": 6.98,
      "total": 32.07,
      "electricity_usd_2026_kwh": 0.216,
      "wacc": 0.0361,
      "construction_real_factor": 0.82253,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.18,
      "electricity": 5.44,
      "site_grid": 2.98,
      "operations": 7.91,
      "total": 52.5,
      "electricity_usd_2026_kwh": 0.216,
      "wacc": 0.0361,
      "construction_real_factor": 0.82253,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.14,
      "electricity": 6.95,
      "site_grid": 3.12,
      "operations": 16.16,
      "total": 71.38,
      "electricity_usd_2026_kwh": 0.216,
      "wacc": 0.0361,
      "construction_real_factor": 0.82253,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.04,
      "electricity": 12.8,
      "site_grid": 6.59,
      "operations": 18.78,
      "total": 118.2,
      "electricity_usd_2026_kwh": 0.216,
      "wacc": 0.0361,
      "construction_real_factor": 0.82253,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.87,
      "electricity": 16.38,
      "site_grid": 6.9,
      "operations": 38.45,
      "total": 161.59,
      "electricity_usd_2026_kwh": 0.216,
      "wacc": 0.0361,
      "construction_real_factor": 0.82253,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.89,
      "electricity": 1.91,
      "site_grid": 1.38,
      "operations": 3.42,
      "total": 23.6,
      "electricity_usd_2026_kwh": 0.2062,
      "wacc": 0.035,
      "construction_real_factor": 0.81728,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.03,
      "electricity": 2.45,
      "site_grid": 1.44,
      "operations": 6.98,
      "total": 31.89,
      "electricity_usd_2026_kwh": 0.2062,
      "wacc": 0.035,
      "construction_real_factor": 0.81728,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.18,
      "electricity": 5.19,
      "site_grid": 2.96,
      "operations": 7.91,
      "total": 52.23,
      "electricity_usd_2026_kwh": 0.2062,
      "wacc": 0.035,
      "construction_real_factor": 0.81728,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.05,
      "electricity": 6.64,
      "site_grid": 3.08,
      "operations": 16.16,
      "total": 70.93,
      "electricity_usd_2026_kwh": 0.2062,
      "wacc": 0.035,
      "construction_real_factor": 0.81728,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.04,
      "electricity": 12.21,
      "site_grid": 6.54,
      "operations": 18.78,
      "total": 117.57,
      "electricity_usd_2026_kwh": 0.2062,
      "wacc": 0.035,
      "construction_real_factor": 0.81728,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.67,
      "electricity": 15.63,
      "site_grid": 6.81,
      "operations": 38.45,
      "total": 160.55,
      "electricity_usd_2026_kwh": 0.2062,
      "wacc": 0.035,
      "construction_real_factor": 0.81728,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.89,
      "electricity": 1.92,
      "site_grid": 1.39,
      "operations": 3.42,
      "total": 23.61,
      "electricity_usd_2026_kwh": 0.2071,
      "wacc": 0.038,
      "construction_real_factor": 0.82039,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.15,
      "electricity": 2.46,
      "site_grid": 1.47,
      "operations": 6.98,
      "total": 32.05,
      "electricity_usd_2026_kwh": 0.2071,
      "wacc": 0.038,
      "construction_real_factor": 0.82039,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.18,
      "electricity": 5.21,
      "site_grid": 2.97,
      "operations": 7.91,
      "total": 52.26,
      "electricity_usd_2026_kwh": 0.2071,
      "wacc": 0.038,
      "construction_real_factor": 0.82039,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.31,
      "electricity": 6.66,
      "site_grid": 3.15,
      "operations": 16.16,
      "total": 71.28,
      "electricity_usd_2026_kwh": 0.2071,
      "wacc": 0.038,
      "construction_real_factor": 0.82039,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.04,
      "electricity": 12.27,
      "site_grid": 6.57,
      "operations": 18.78,
      "total": 117.65,
      "electricity_usd_2026_kwh": 0.2071,
      "wacc": 0.038,
      "construction_real_factor": 0.82039,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.23,
      "electricity": 15.7,
      "site_grid": 6.96,
      "operations": 38.45,
      "total": 161.34,
      "electricity_usd_2026_kwh": 0.2071,
      "wacc": 0.038,
      "construction_real_factor": 0.82039,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.01,
      "electricity": 1.97,
      "site_grid": 1.46,
      "operations": 3.42,
      "total": 23.85,
      "electricity_usd_2026_kwh": 0.2119,
      "wacc": 0.0438,
      "construction_real_factor": 0.8388,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.38,
      "electricity": 2.52,
      "site_grid": 1.55,
      "operations": 6.98,
      "total": 32.43,
      "electricity_usd_2026_kwh": 0.2119,
      "wacc": 0.0438,
      "construction_real_factor": 0.8388,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.44,
      "electricity": 5.33,
      "site_grid": 3.12,
      "operations": 7.91,
      "total": 52.8,
      "electricity_usd_2026_kwh": 0.2119,
      "wacc": 0.0438,
      "construction_real_factor": 0.8388,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.81,
      "electricity": 6.82,
      "site_grid": 3.33,
      "operations": 16.16,
      "total": 72.12,
      "electricity_usd_2026_kwh": 0.2119,
      "wacc": 0.0438,
      "construction_real_factor": 0.8388,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.62,
      "electricity": 12.55,
      "site_grid": 6.9,
      "operations": 18.78,
      "total": 118.86,
      "electricity_usd_2026_kwh": 0.2119,
      "wacc": 0.0438,
      "construction_real_factor": 0.8388,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.35,
      "electricity": 16.06,
      "site_grid": 7.36,
      "operations": 38.45,
      "total": 163.22,
      "electricity_usd_2026_kwh": 0.2119,
      "wacc": 0.0438,
      "construction_real_factor": 0.8388,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.89,
      "electricity": 1.95,
      "site_grid": 1.47,
      "operations": 3.42,
      "total": 23.73,
      "electricity_usd_2026_kwh": 0.2103,
      "wacc": 0.0361,
      "construction_real_factor": 0.87274,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.07,
      "electricity": 2.5,
      "site_grid": 1.54,
      "operations": 6.98,
      "total": 32.09,
      "electricity_usd_2026_kwh": 0.2103,
      "wacc": 0.0361,
      "construction_real_factor": 0.87274,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.18,
      "electricity": 5.29,
      "site_grid": 3.16,
      "operations": 7.91,
      "total": 52.53,
      "electricity_usd_2026_kwh": 0.2103,
      "wacc": 0.0361,
      "construction_real_factor": 0.87274,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.14,
      "electricity": 6.77,
      "site_grid": 3.31,
      "operations": 16.16,
      "total": 71.39,
      "electricity_usd_2026_kwh": 0.2103,
      "wacc": 0.0361,
      "construction_real_factor": 0.87274,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.04,
      "electricity": 12.46,
      "site_grid": 6.99,
      "operations": 18.78,
      "total": 118.26,
      "electricity_usd_2026_kwh": 0.2103,
      "wacc": 0.0361,
      "construction_real_factor": 0.87274,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.88,
      "electricity": 15.94,
      "site_grid": 7.32,
      "operations": 38.45,
      "total": 161.59,
      "electricity_usd_2026_kwh": 0.2103,
      "wacc": 0.0361,
      "construction_real_factor": 0.87274,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.89,
      "electricity": 2.05,
      "site_grid": 1.5,
      "operations": 3.42,
      "total": 23.85,
      "electricity_usd_2026_kwh": 0.2209,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.03,
      "electricity": 2.62,
      "site_grid": 1.56,
      "operations": 6.98,
      "total": 32.19,
      "electricity_usd_2026_kwh": 0.2209,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.18,
      "electricity": 5.56,
      "site_grid": 3.21,
      "operations": 7.91,
      "total": 52.85,
      "electricity_usd_2026_kwh": 0.2209,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.05,
      "electricity": 7.11,
      "site_grid": 3.34,
      "operations": 16.16,
      "total": 71.67,
      "electricity_usd_2026_kwh": 0.2209,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.04,
      "electricity": 13.09,
      "site_grid": 7.11,
      "operations": 18.78,
      "total": 119.01,
      "electricity_usd_2026_kwh": 0.2209,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.67,
      "electricity": 16.75,
      "site_grid": 7.4,
      "operations": 38.45,
      "total": 162.26,
      "electricity_usd_2026_kwh": 0.2209,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.89,
      "electricity": 2.21,
      "site_grid": 1.51,
      "operations": 3.42,
      "total": 24.02,
      "electricity_usd_2026_kwh": 0.238,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.03,
      "electricity": 2.83,
      "site_grid": 1.57,
      "operations": 6.98,
      "total": 32.4,
      "electricity_usd_2026_kwh": 0.238,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.18,
      "electricity": 5.99,
      "site_grid": 3.23,
      "operations": 7.91,
      "total": 53.3,
      "electricity_usd_2026_kwh": 0.238,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.05,
      "electricity": 7.66,
      "site_grid": 3.36,
      "operations": 16.16,
      "total": 72.24,
      "electricity_usd_2026_kwh": 0.238,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.04,
      "electricity": 14.1,
      "site_grid": 7.14,
      "operations": 18.78,
      "total": 120.06,
      "electricity_usd_2026_kwh": 0.238,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.67,
      "electricity": 18.04,
      "site_grid": 7.44,
      "operations": 38.45,
      "total": 163.59,
      "electricity_usd_2026_kwh": 0.238,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.02,
      "electricity": 2.62,
      "site_grid": 1.76,
      "operations": 3.42,
      "total": 24.82,
      "electricity_usd_2026_kwh": 0.2827,
      "wacc": 0.0442,
      "construction_real_factor": 1.0102,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.4,
      "electricity": 3.36,
      "site_grid": 1.87,
      "operations": 6.98,
      "total": 33.61,
      "electricity_usd_2026_kwh": 0.2827,
      "wacc": 0.0442,
      "construction_real_factor": 1.0102,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.47,
      "electricity": 7.11,
      "site_grid": 3.77,
      "operations": 7.91,
      "total": 55.25,
      "electricity_usd_2026_kwh": 0.2827,
      "wacc": 0.0442,
      "construction_real_factor": 1.0102,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.84,
      "electricity": 9.1,
      "site_grid": 4.01,
      "operations": 16.16,
      "total": 75.12,
      "electricity_usd_2026_kwh": 0.2827,
      "wacc": 0.0442,
      "construction_real_factor": 1.0102,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.68,
      "electricity": 16.75,
      "site_grid": 8.34,
      "operations": 18.78,
      "total": 124.54,
      "electricity_usd_2026_kwh": 0.2827,
      "wacc": 0.0442,
      "construction_real_factor": 1.0102,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.42,
      "electricity": 21.43,
      "site_grid": 8.88,
      "operations": 38.45,
      "total": 170.18,
      "electricity_usd_2026_kwh": 0.2827,
      "wacc": 0.0442,
      "construction_real_factor": 1.0102,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.35,
      "electricity": 2.73,
      "site_grid": 1.95,
      "operations": 3.42,
      "total": 25.44,
      "electricity_usd_2026_kwh": 0.2938,
      "wacc": 0.0543,
      "construction_real_factor": 1.04368,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.81,
      "electricity": 3.49,
      "site_grid": 2.05,
      "operations": 6.98,
      "total": 34.32,
      "electricity_usd_2026_kwh": 0.2938,
      "wacc": 0.0543,
      "construction_real_factor": 1.04368,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.17,
      "electricity": 7.39,
      "site_grid": 4.18,
      "operations": 7.91,
      "total": 56.64,
      "electricity_usd_2026_kwh": 0.2938,
      "wacc": 0.0543,
      "construction_real_factor": 1.04368,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.72,
      "electricity": 9.46,
      "site_grid": 4.39,
      "operations": 16.16,
      "total": 76.73,
      "electricity_usd_2026_kwh": 0.2938,
      "wacc": 0.0543,
      "construction_real_factor": 1.04368,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.23,
      "electricity": 17.41,
      "site_grid": 9.24,
      "operations": 18.78,
      "total": 127.66,
      "electricity_usd_2026_kwh": 0.2938,
      "wacc": 0.0543,
      "construction_real_factor": 1.04368,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.36,
      "electricity": 22.27,
      "site_grid": 9.71,
      "operations": 38.45,
      "total": 173.79,
      "electricity_usd_2026_kwh": 0.2938,
      "wacc": 0.0543,
      "construction_real_factor": 1.04368,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.43,
      "electricity": 2.44,
      "site_grid": 1.92,
      "operations": 3.42,
      "total": 25.21,
      "electricity_usd_2026_kwh": 0.2628,
      "wacc": 0.0568,
      "construction_real_factor": 1.01036,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.91,
      "electricity": 3.12,
      "site_grid": 2.01,
      "operations": 6.98,
      "total": 34.02,
      "electricity_usd_2026_kwh": 0.2628,
      "wacc": 0.0568,
      "construction_real_factor": 1.01036,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.34,
      "electricity": 6.61,
      "site_grid": 4.11,
      "operations": 7.91,
      "total": 55.98,
      "electricity_usd_2026_kwh": 0.2628,
      "wacc": 0.0568,
      "construction_real_factor": 1.01036,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.94,
      "electricity": 8.46,
      "site_grid": 4.31,
      "operations": 16.16,
      "total": 75.87,
      "electricity_usd_2026_kwh": 0.2628,
      "wacc": 0.0568,
      "construction_real_factor": 1.01036,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.62,
      "electricity": 15.57,
      "site_grid": 9.1,
      "operations": 18.78,
      "total": 126.07,
      "electricity_usd_2026_kwh": 0.2628,
      "wacc": 0.0568,
      "construction_real_factor": 1.01036,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.84,
      "electricity": 19.93,
      "site_grid": 9.54,
      "operations": 38.45,
      "total": 171.75,
      "electricity_usd_2026_kwh": 0.2628,
      "wacc": 0.0568,
      "construction_real_factor": 1.01036,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.46,
      "electricity": 2.43,
      "site_grid": 1.91,
      "operations": 3.42,
      "total": 25.21,
      "electricity_usd_2026_kwh": 0.2614,
      "wacc": 0.0576,
      "construction_real_factor": 0.99742,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.94,
      "electricity": 3.1,
      "site_grid": 2.0,
      "operations": 6.98,
      "total": 34.02,
      "electricity_usd_2026_kwh": 0.2614,
      "wacc": 0.0576,
      "construction_real_factor": 0.99742,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.4,
      "electricity": 6.58,
      "site_grid": 4.09,
      "operations": 7.91,
      "total": 55.97,
      "electricity_usd_2026_kwh": 0.2614,
      "wacc": 0.0576,
      "construction_real_factor": 0.99742,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.01,
      "electricity": 8.42,
      "site_grid": 4.28,
      "operations": 16.16,
      "total": 75.87,
      "electricity_usd_2026_kwh": 0.2614,
      "wacc": 0.0576,
      "construction_real_factor": 0.99742,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.75,
      "electricity": 15.49,
      "site_grid": 9.04,
      "operations": 18.78,
      "total": 126.05,
      "electricity_usd_2026_kwh": 0.2614,
      "wacc": 0.0576,
      "construction_real_factor": 0.99742,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.0,
      "electricity": 19.82,
      "site_grid": 9.46,
      "operations": 38.45,
      "total": 171.73,
      "electricity_usd_2026_kwh": 0.2614,
      "wacc": 0.0576,
      "construction_real_factor": 0.99742,
      "power_source": "EU-anchored European proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.47,
      "electricity": 2.43,
      "site_grid": 1.92,
      "operations": 3.42,
      "total": 25.23,
      "electricity_usd_2026_kwh": 0.2614,
      "wacc": 0.058,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.96,
      "electricity": 3.1,
      "site_grid": 2.0,
      "operations": 6.98,
      "total": 34.04,
      "electricity_usd_2026_kwh": 0.2614,
      "wacc": 0.058,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.43,
      "electricity": 6.58,
      "site_grid": 4.11,
      "operations": 7.91,
      "total": 56.02,
      "electricity_usd_2026_kwh": 0.2614,
      "wacc": 0.058,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.04,
      "electricity": 8.42,
      "site_grid": 4.3,
      "operations": 16.16,
      "total": 75.92,
      "electricity_usd_2026_kwh": 0.2614,
      "wacc": 0.058,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.81,
      "electricity": 15.49,
      "site_grid": 9.09,
      "operations": 18.78,
      "total": 126.16,
      "electricity_usd_2026_kwh": 0.2614,
      "wacc": 0.058,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.08,
      "electricity": 19.82,
      "site_grid": 9.5,
      "operations": 38.45,
      "total": 171.84,
      "electricity_usd_2026_kwh": 0.2614,
      "wacc": 0.058,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.44,
      "electricity": 1.86,
      "site_grid": 1.55,
      "operations": 3.33,
      "total": 24.18,
      "electricity_usd_2026_kwh": 0.1999,
      "wacc": 0.0618,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.94,
      "electricity": 2.38,
      "site_grid": 1.73,
      "operations": 6.56,
      "total": 32.61,
      "electricity_usd_2026_kwh": 0.1999,
      "wacc": 0.0618,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.36,
      "electricity": 5.03,
      "site_grid": 3.33,
      "operations": 7.72,
      "total": 53.44,
      "electricity_usd_2026_kwh": 0.1999,
      "wacc": 0.0618,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.02,
      "electricity": 6.45,
      "site_grid": 3.7,
      "operations": 15.28,
      "total": 72.44,
      "electricity_usd_2026_kwh": 0.1999,
      "wacc": 0.0618,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.66,
      "electricity": 11.85,
      "site_grid": 7.36,
      "operations": 18.36,
      "total": 120.24,
      "electricity_usd_2026_kwh": 0.1999,
      "wacc": 0.0618,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.02,
      "electricity": 15.18,
      "site_grid": 8.18,
      "operations": 36.49,
      "total": 163.88,
      "electricity_usd_2026_kwh": 0.1999,
      "wacc": 0.0618,
      "construction_real_factor": 0.79525,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.3,
      "electricity": 1.92,
      "site_grid": 1.49,
      "operations": 3.33,
      "total": 24.04,
      "electricity_usd_2026_kwh": 0.2072,
      "wacc": 0.0575,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.77,
      "electricity": 2.47,
      "site_grid": 1.66,
      "operations": 6.56,
      "total": 32.46,
      "electricity_usd_2026_kwh": 0.2072,
      "wacc": 0.0575,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.06,
      "electricity": 5.22,
      "site_grid": 3.19,
      "operations": 7.72,
      "total": 53.19,
      "electricity_usd_2026_kwh": 0.2072,
      "wacc": 0.0575,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.64,
      "electricity": 6.68,
      "site_grid": 3.56,
      "operations": 15.28,
      "total": 72.17,
      "electricity_usd_2026_kwh": 0.2072,
      "wacc": 0.0575,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.0,
      "electricity": 12.29,
      "site_grid": 7.06,
      "operations": 18.36,
      "total": 119.7,
      "electricity_usd_2026_kwh": 0.2072,
      "wacc": 0.0575,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.19,
      "electricity": 15.74,
      "site_grid": 7.88,
      "operations": 36.49,
      "total": 163.31,
      "electricity_usd_2026_kwh": 0.2072,
      "wacc": 0.0575,
      "construction_real_factor": 0.78459,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.98,
      "electricity": 2.01,
      "site_grid": 1.4,
      "operations": 3.33,
      "total": 23.72,
      "electricity_usd_2026_kwh": 0.2161,
      "wacc": 0.0477,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.38,
      "electricity": 2.57,
      "site_grid": 1.58,
      "operations": 6.56,
      "total": 32.09,
      "electricity_usd_2026_kwh": 0.2161,
      "wacc": 0.0477,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.39,
      "electricity": 5.44,
      "site_grid": 2.99,
      "operations": 7.72,
      "total": 52.54,
      "electricity_usd_2026_kwh": 0.2161,
      "wacc": 0.0477,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.8,
      "electricity": 6.97,
      "site_grid": 3.39,
      "operations": 15.28,
      "total": 71.44,
      "electricity_usd_2026_kwh": 0.2161,
      "wacc": 0.0477,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.5,
      "electricity": 12.81,
      "site_grid": 6.62,
      "operations": 18.36,
      "total": 118.3,
      "electricity_usd_2026_kwh": 0.2161,
      "wacc": 0.0477,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.32,
      "electricity": 16.41,
      "site_grid": 7.5,
      "operations": 36.49,
      "total": 161.73,
      "electricity_usd_2026_kwh": 0.2161,
      "wacc": 0.0477,
      "construction_real_factor": 0.7887,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.16,
      "electricity": 2.07,
      "site_grid": 1.46,
      "operations": 3.33,
      "total": 24.02,
      "electricity_usd_2026_kwh": 0.2225,
      "wacc": 0.0532,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.6,
      "electricity": 2.65,
      "site_grid": 1.65,
      "operations": 6.56,
      "total": 32.45,
      "electricity_usd_2026_kwh": 0.2225,
      "wacc": 0.0532,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.77,
      "electricity": 5.6,
      "site_grid": 3.14,
      "operations": 7.72,
      "total": 53.22,
      "electricity_usd_2026_kwh": 0.2225,
      "wacc": 0.0532,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.27,
      "electricity": 7.17,
      "site_grid": 3.53,
      "operations": 15.28,
      "total": 72.25,
      "electricity_usd_2026_kwh": 0.2225,
      "wacc": 0.0532,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.34,
      "electricity": 13.19,
      "site_grid": 6.94,
      "operations": 18.36,
      "total": 119.83,
      "electricity_usd_2026_kwh": 0.2225,
      "wacc": 0.0532,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.36,
      "electricity": 16.9,
      "site_grid": 7.8,
      "operations": 36.49,
      "total": 163.56,
      "electricity_usd_2026_kwh": 0.2225,
      "wacc": 0.0532,
      "construction_real_factor": 0.79534,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.22,
      "electricity": 2.26,
      "site_grid": 1.51,
      "operations": 3.33,
      "total": 24.32,
      "electricity_usd_2026_kwh": 0.2438,
      "wacc": 0.0551,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.67,
      "electricity": 2.9,
      "site_grid": 1.69,
      "operations": 6.56,
      "total": 32.83,
      "electricity_usd_2026_kwh": 0.2438,
      "wacc": 0.0551,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.9,
      "electricity": 6.14,
      "site_grid": 3.23,
      "operations": 7.72,
      "total": 53.98,
      "electricity_usd_2026_kwh": 0.2438,
      "wacc": 0.0551,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.43,
      "electricity": 7.86,
      "site_grid": 3.62,
      "operations": 15.28,
      "total": 73.19,
      "electricity_usd_2026_kwh": 0.2438,
      "wacc": 0.0551,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.63,
      "electricity": 14.45,
      "site_grid": 7.14,
      "operations": 18.36,
      "total": 121.59,
      "electricity_usd_2026_kwh": 0.2438,
      "wacc": 0.0551,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.73,
      "electricity": 18.52,
      "site_grid": 8.01,
      "operations": 36.49,
      "total": 165.75,
      "electricity_usd_2026_kwh": 0.2438,
      "wacc": 0.0551,
      "construction_real_factor": 0.80787,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.09,
      "electricity": 2.16,
      "site_grid": 1.49,
      "operations": 3.33,
      "total": 24.08,
      "electricity_usd_2026_kwh": 0.2329,
      "wacc": 0.0511,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.51,
      "electricity": 2.77,
      "site_grid": 1.68,
      "operations": 6.56,
      "total": 32.53,
      "electricity_usd_2026_kwh": 0.2329,
      "wacc": 0.0511,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.62,
      "electricity": 5.86,
      "site_grid": 3.2,
      "operations": 7.72,
      "total": 53.4,
      "electricity_usd_2026_kwh": 0.2329,
      "wacc": 0.0511,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.09,
      "electricity": 7.51,
      "site_grid": 3.6,
      "operations": 15.28,
      "total": 72.48,
      "electricity_usd_2026_kwh": 0.2329,
      "wacc": 0.0511,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.02,
      "electricity": 13.81,
      "site_grid": 7.07,
      "operations": 18.36,
      "total": 120.26,
      "electricity_usd_2026_kwh": 0.2329,
      "wacc": 0.0511,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.96,
      "electricity": 17.69,
      "site_grid": 7.97,
      "operations": 36.49,
      "total": 164.12,
      "electricity_usd_2026_kwh": 0.2329,
      "wacc": 0.0511,
      "construction_real_factor": 0.82253,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.99,
      "electricity": 1.88,
      "site_grid": 1.45,
      "operations": 3.33,
      "total": 23.66,
      "electricity_usd_2026_kwh": 0.2024,
      "wacc": 0.0481,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.39,
      "electricity": 2.41,
      "site_grid": 1.64,
      "operations": 6.56,
      "total": 32.0,
      "electricity_usd_2026_kwh": 0.2024,
      "wacc": 0.0481,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.41,
      "electricity": 5.1,
      "site_grid": 3.11,
      "operations": 7.72,
      "total": 52.33,
      "electricity_usd_2026_kwh": 0.2024,
      "wacc": 0.0481,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.83,
      "electricity": 6.53,
      "site_grid": 3.52,
      "operations": 15.28,
      "total": 71.15,
      "electricity_usd_2026_kwh": 0.2024,
      "wacc": 0.0481,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.56,
      "electricity": 12.0,
      "site_grid": 6.88,
      "operations": 18.36,
      "total": 117.8,
      "electricity_usd_2026_kwh": 0.2024,
      "wacc": 0.0481,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.38,
      "electricity": 15.37,
      "site_grid": 7.79,
      "operations": 36.49,
      "total": 161.04,
      "electricity_usd_2026_kwh": 0.2024,
      "wacc": 0.0481,
      "construction_real_factor": 0.81728,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.15,
      "electricity": 1.78,
      "site_grid": 1.51,
      "operations": 3.33,
      "total": 23.77,
      "electricity_usd_2026_kwh": 0.1912,
      "wacc": 0.053,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.59,
      "electricity": 2.28,
      "site_grid": 1.7,
      "operations": 6.56,
      "total": 32.12,
      "electricity_usd_2026_kwh": 0.1912,
      "wacc": 0.053,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.75,
      "electricity": 4.81,
      "site_grid": 3.23,
      "operations": 7.72,
      "total": 52.51,
      "electricity_usd_2026_kwh": 0.1912,
      "wacc": 0.053,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.25,
      "electricity": 6.17,
      "site_grid": 3.63,
      "operations": 15.28,
      "total": 71.33,
      "electricity_usd_2026_kwh": 0.1912,
      "wacc": 0.053,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.31,
      "electricity": 11.34,
      "site_grid": 7.15,
      "operations": 18.36,
      "total": 118.16,
      "electricity_usd_2026_kwh": 0.1912,
      "wacc": 0.053,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.32,
      "electricity": 14.53,
      "site_grid": 8.04,
      "operations": 36.49,
      "total": 161.38,
      "electricity_usd_2026_kwh": 0.1912,
      "wacc": 0.053,
      "construction_real_factor": 0.82039,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.34,
      "electricity": 1.99,
      "site_grid": 1.61,
      "operations": 3.33,
      "total": 24.27,
      "electricity_usd_2026_kwh": 0.2145,
      "wacc": 0.0588,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.82,
      "electricity": 2.55,
      "site_grid": 1.79,
      "operations": 6.56,
      "total": 32.73,
      "electricity_usd_2026_kwh": 0.2145,
      "wacc": 0.0588,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.15,
      "electricity": 5.4,
      "site_grid": 3.44,
      "operations": 7.72,
      "total": 53.71,
      "electricity_usd_2026_kwh": 0.2145,
      "wacc": 0.0588,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.75,
      "electricity": 6.92,
      "site_grid": 3.84,
      "operations": 15.28,
      "total": 72.79,
      "electricity_usd_2026_kwh": 0.2145,
      "wacc": 0.0588,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.2,
      "electricity": 12.72,
      "site_grid": 7.61,
      "operations": 18.36,
      "total": 120.89,
      "electricity_usd_2026_kwh": 0.2145,
      "wacc": 0.0588,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.44,
      "electricity": 16.3,
      "site_grid": 8.49,
      "operations": 36.49,
      "total": 164.72,
      "electricity_usd_2026_kwh": 0.2145,
      "wacc": 0.0588,
      "construction_real_factor": 0.8388,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.09,
      "electricity": 2.07,
      "site_grid": 1.58,
      "operations": 3.33,
      "total": 24.08,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.0511,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.51,
      "electricity": 2.65,
      "site_grid": 1.79,
      "operations": 6.56,
      "total": 32.51,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.0511,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.62,
      "electricity": 5.61,
      "site_grid": 3.39,
      "operations": 7.72,
      "total": 53.34,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.0511,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.09,
      "electricity": 7.19,
      "site_grid": 3.83,
      "operations": 15.28,
      "total": 72.38,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.0511,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.02,
      "electricity": 13.22,
      "site_grid": 7.51,
      "operations": 18.36,
      "total": 120.11,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.0511,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.96,
      "electricity": 16.93,
      "site_grid": 8.46,
      "operations": 36.49,
      "total": 163.85,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.0511,
      "construction_real_factor": 0.87274,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.74,
      "electricity": 2.23,
      "site_grid": 1.49,
      "operations": 3.33,
      "total": 23.79,
      "electricity_usd_2026_kwh": 0.2403,
      "wacc": 0.0386,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.01,
      "electricity": 2.86,
      "site_grid": 1.69,
      "operations": 6.56,
      "total": 32.12,
      "electricity_usd_2026_kwh": 0.2403,
      "wacc": 0.0386,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.86,
      "electricity": 6.05,
      "site_grid": 3.19,
      "operations": 7.72,
      "total": 52.81,
      "electricity_usd_2026_kwh": 0.2403,
      "wacc": 0.0386,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.01,
      "electricity": 7.75,
      "site_grid": 3.62,
      "operations": 15.28,
      "total": 71.66,
      "electricity_usd_2026_kwh": 0.2403,
      "wacc": 0.0386,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.33,
      "electricity": 14.25,
      "site_grid": 7.05,
      "operations": 18.36,
      "total": 119.0,
      "electricity_usd_2026_kwh": 0.2403,
      "wacc": 0.0386,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.58,
      "electricity": 18.26,
      "site_grid": 8.01,
      "operations": 36.49,
      "total": 162.34,
      "electricity_usd_2026_kwh": 0.2403,
      "wacc": 0.0386,
      "construction_real_factor": 0.88762,
      "power_source": "Eurostat observed/interpolated",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.87,
      "electricity": 2.96,
      "site_grid": 1.54,
      "operations": 3.33,
      "total": 24.7,
      "electricity_usd_2026_kwh": 0.3186,
      "wacc": 0.0442,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.23,
      "electricity": 3.79,
      "site_grid": 1.75,
      "operations": 6.56,
      "total": 33.34,
      "electricity_usd_2026_kwh": 0.3186,
      "wacc": 0.0442,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.14,
      "electricity": 8.02,
      "site_grid": 3.3,
      "operations": 7.72,
      "total": 55.18,
      "electricity_usd_2026_kwh": 0.3186,
      "wacc": 0.0442,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.49,
      "electricity": 10.28,
      "site_grid": 3.76,
      "operations": 15.28,
      "total": 74.8,
      "electricity_usd_2026_kwh": 0.3186,
      "wacc": 0.0442,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.96,
      "electricity": 18.89,
      "site_grid": 7.31,
      "operations": 18.36,
      "total": 124.52,
      "electricity_usd_2026_kwh": 0.3186,
      "wacc": 0.0442,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.64,
      "electricity": 24.2,
      "site_grid": 8.32,
      "operations": 36.49,
      "total": 169.65,
      "electricity_usd_2026_kwh": 0.3186,
      "wacc": 0.0442,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.35,
      "electricity": 3.51,
      "site_grid": 1.94,
      "operations": 3.33,
      "total": 26.14,
      "electricity_usd_2026_kwh": 0.3784,
      "wacc": 0.0592,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.84,
      "electricity": 4.5,
      "site_grid": 2.16,
      "operations": 6.56,
      "total": 35.07,
      "electricity_usd_2026_kwh": 0.3784,
      "wacc": 0.0592,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.18,
      "electricity": 9.53,
      "site_grid": 4.15,
      "operations": 7.72,
      "total": 58.58,
      "electricity_usd_2026_kwh": 0.3784,
      "wacc": 0.0592,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.79,
      "electricity": 12.2,
      "site_grid": 4.63,
      "operations": 15.28,
      "total": 78.9,
      "electricity_usd_2026_kwh": 0.3784,
      "wacc": 0.0592,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.26,
      "electricity": 22.44,
      "site_grid": 9.19,
      "operations": 18.36,
      "total": 132.25,
      "electricity_usd_2026_kwh": 0.3784,
      "wacc": 0.0592,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.51,
      "electricity": 28.74,
      "site_grid": 10.25,
      "operations": 36.49,
      "total": 179.0,
      "electricity_usd_2026_kwh": 0.3784,
      "wacc": 0.0592,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.68,
      "electricity": 3.65,
      "site_grid": 2.14,
      "operations": 3.33,
      "total": 26.81,
      "electricity_usd_2026_kwh": 0.3933,
      "wacc": 0.0693,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.25,
      "electricity": 4.68,
      "site_grid": 2.36,
      "operations": 6.56,
      "total": 35.85,
      "electricity_usd_2026_kwh": 0.3933,
      "wacc": 0.0693,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.88,
      "electricity": 9.9,
      "site_grid": 4.59,
      "operations": 7.72,
      "total": 60.09,
      "electricity_usd_2026_kwh": 0.3933,
      "wacc": 0.0693,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.66,
      "electricity": 12.68,
      "site_grid": 5.05,
      "operations": 15.28,
      "total": 80.68,
      "electricity_usd_2026_kwh": 0.3933,
      "wacc": 0.0693,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.81,
      "electricity": 23.32,
      "site_grid": 10.16,
      "operations": 18.36,
      "total": 135.65,
      "electricity_usd_2026_kwh": 0.3933,
      "wacc": 0.0693,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.45,
      "electricity": 29.87,
      "site_grid": 11.18,
      "operations": 36.49,
      "total": 183.0,
      "electricity_usd_2026_kwh": 0.3933,
      "wacc": 0.0693,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.76,
      "electricity": 3.27,
      "site_grid": 2.11,
      "operations": 3.33,
      "total": 26.47,
      "electricity_usd_2026_kwh": 0.3518,
      "wacc": 0.0718,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.35,
      "electricity": 4.19,
      "site_grid": 2.31,
      "operations": 6.56,
      "total": 35.41,
      "electricity_usd_2026_kwh": 0.3518,
      "wacc": 0.0718,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.06,
      "electricity": 8.86,
      "site_grid": 4.52,
      "operations": 7.72,
      "total": 59.15,
      "electricity_usd_2026_kwh": 0.3518,
      "wacc": 0.0718,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.88,
      "electricity": 11.35,
      "site_grid": 4.96,
      "operations": 15.28,
      "total": 79.47,
      "electricity_usd_2026_kwh": 0.3518,
      "wacc": 0.0718,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.19,
      "electricity": 20.86,
      "site_grid": 9.99,
      "operations": 18.36,
      "total": 133.41,
      "electricity_usd_2026_kwh": 0.3518,
      "wacc": 0.0718,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.93,
      "electricity": 26.73,
      "site_grid": 10.97,
      "operations": 36.49,
      "total": 180.12,
      "electricity_usd_2026_kwh": 0.3518,
      "wacc": 0.0718,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.79,
      "electricity": 3.25,
      "site_grid": 2.09,
      "operations": 3.33,
      "total": 26.46,
      "electricity_usd_2026_kwh": 0.35,
      "wacc": 0.0726,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.38,
      "electricity": 4.16,
      "site_grid": 2.29,
      "operations": 6.56,
      "total": 35.41,
      "electricity_usd_2026_kwh": 0.35,
      "wacc": 0.0726,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.12,
      "electricity": 8.81,
      "site_grid": 4.48,
      "operations": 7.72,
      "total": 59.13,
      "electricity_usd_2026_kwh": 0.35,
      "wacc": 0.0726,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.96,
      "electricity": 11.29,
      "site_grid": 4.92,
      "operations": 15.28,
      "total": 79.44,
      "electricity_usd_2026_kwh": 0.35,
      "wacc": 0.0726,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.32,
      "electricity": 20.75,
      "site_grid": 9.92,
      "operations": 18.36,
      "total": 133.36,
      "electricity_usd_2026_kwh": 0.35,
      "wacc": 0.0726,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.09,
      "electricity": 26.58,
      "site_grid": 10.88,
      "operations": 36.49,
      "total": 180.05,
      "electricity_usd_2026_kwh": 0.35,
      "wacc": 0.0726,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.8,
      "electricity": 3.25,
      "site_grid": 2.1,
      "operations": 3.33,
      "total": 26.49,
      "electricity_usd_2026_kwh": 0.35,
      "wacc": 0.073,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.4,
      "electricity": 4.16,
      "site_grid": 2.31,
      "operations": 6.56,
      "total": 35.43,
      "electricity_usd_2026_kwh": 0.35,
      "wacc": 0.073,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.14,
      "electricity": 8.81,
      "site_grid": 4.51,
      "operations": 7.72,
      "total": 59.18,
      "electricity_usd_2026_kwh": 0.35,
      "wacc": 0.073,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.99,
      "electricity": 11.29,
      "site_grid": 4.94,
      "operations": 15.28,
      "total": 79.49,
      "electricity_usd_2026_kwh": 0.35,
      "wacc": 0.073,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.38,
      "electricity": 20.75,
      "site_grid": 9.97,
      "operations": 18.36,
      "total": 133.47,
      "electricity_usd_2026_kwh": 0.35,
      "wacc": 0.073,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.17,
      "electricity": 26.58,
      "site_grid": 10.93,
      "operations": 36.49,
      "total": 180.17,
      "electricity_usd_2026_kwh": 0.35,
      "wacc": 0.073,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.15,
      "electricity": 0.98,
      "site_grid": 1.5,
      "operations": 3.29,
      "total": 22.92,
      "electricity_usd_2026_kwh": 0.1026,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.58,
      "electricity": 1.25,
      "site_grid": 1.5,
      "operations": 6.58,
      "total": 30.92,
      "electricity_usd_2026_kwh": 0.1026,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.75,
      "electricity": 2.65,
      "site_grid": 3.21,
      "operations": 7.64,
      "total": 50.26,
      "electricity_usd_2026_kwh": 0.1026,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.24,
      "electricity": 3.4,
      "site_grid": 3.21,
      "operations": 15.32,
      "total": 68.17,
      "electricity_usd_2026_kwh": 0.1026,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.3,
      "electricity": 6.25,
      "site_grid": 7.1,
      "operations": 18.19,
      "total": 112.85,
      "electricity_usd_2026_kwh": 0.1026,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.3,
      "electricity": 8.0,
      "site_grid": 7.09,
      "operations": 36.59,
      "total": 153.98,
      "electricity_usd_2026_kwh": 0.1026,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.02,
      "electricity": 0.96,
      "site_grid": 1.44,
      "operations": 3.29,
      "total": 22.7,
      "electricity_usd_2026_kwh": 0.1002,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.41,
      "electricity": 1.22,
      "site_grid": 1.44,
      "operations": 6.58,
      "total": 30.66,
      "electricity_usd_2026_kwh": 0.1002,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.46,
      "electricity": 2.59,
      "site_grid": 3.08,
      "operations": 7.64,
      "total": 49.77,
      "electricity_usd_2026_kwh": 0.1002,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.87,
      "electricity": 3.32,
      "site_grid": 3.09,
      "operations": 15.32,
      "total": 67.6,
      "electricity_usd_2026_kwh": 0.1002,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.65,
      "electricity": 6.11,
      "site_grid": 6.81,
      "operations": 18.19,
      "total": 111.77,
      "electricity_usd_2026_kwh": 0.1002,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.49,
      "electricity": 7.82,
      "site_grid": 6.84,
      "operations": 36.59,
      "total": 152.73,
      "electricity_usd_2026_kwh": 0.1002,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.71,
      "electricity": 0.92,
      "site_grid": 1.35,
      "operations": 3.29,
      "total": 22.27,
      "electricity_usd_2026_kwh": 0.096,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.03,
      "electricity": 1.17,
      "site_grid": 1.37,
      "operations": 6.58,
      "total": 30.16,
      "electricity_usd_2026_kwh": 0.096,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.8,
      "electricity": 2.48,
      "site_grid": 2.9,
      "operations": 7.64,
      "total": 48.82,
      "electricity_usd_2026_kwh": 0.096,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.05,
      "electricity": 3.18,
      "site_grid": 2.94,
      "operations": 15.32,
      "total": 66.5,
      "electricity_usd_2026_kwh": 0.096,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.2,
      "electricity": 5.85,
      "site_grid": 6.41,
      "operations": 18.19,
      "total": 109.65,
      "electricity_usd_2026_kwh": 0.096,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.66,
      "electricity": 7.49,
      "site_grid": 6.51,
      "operations": 36.59,
      "total": 150.26,
      "electricity_usd_2026_kwh": 0.096,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.88,
      "electricity": 0.93,
      "site_grid": 1.42,
      "operations": 3.29,
      "total": 22.52,
      "electricity_usd_2026_kwh": 0.0978,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.24,
      "electricity": 1.19,
      "site_grid": 1.43,
      "operations": 6.58,
      "total": 30.45,
      "electricity_usd_2026_kwh": 0.0978,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.17,
      "electricity": 2.53,
      "site_grid": 3.03,
      "operations": 7.64,
      "total": 49.37,
      "electricity_usd_2026_kwh": 0.0978,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.51,
      "electricity": 3.24,
      "site_grid": 3.06,
      "operations": 15.32,
      "total": 67.13,
      "electricity_usd_2026_kwh": 0.0978,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.01,
      "electricity": 5.96,
      "site_grid": 6.71,
      "operations": 18.19,
      "total": 110.87,
      "electricity_usd_2026_kwh": 0.0978,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.68,
      "electricity": 7.63,
      "site_grid": 6.77,
      "operations": 36.59,
      "total": 151.66,
      "electricity_usd_2026_kwh": 0.0978,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.94,
      "electricity": 0.95,
      "site_grid": 1.46,
      "operations": 3.29,
      "total": 22.64,
      "electricity_usd_2026_kwh": 0.0991,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.32,
      "electricity": 1.21,
      "site_grid": 1.47,
      "operations": 6.58,
      "total": 30.58,
      "electricity_usd_2026_kwh": 0.0991,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.29,
      "electricity": 2.56,
      "site_grid": 3.12,
      "operations": 7.64,
      "total": 49.62,
      "electricity_usd_2026_kwh": 0.0991,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.67,
      "electricity": 3.28,
      "site_grid": 3.14,
      "operations": 15.32,
      "total": 67.41,
      "electricity_usd_2026_kwh": 0.0991,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.29,
      "electricity": 6.04,
      "site_grid": 6.9,
      "operations": 18.19,
      "total": 111.43,
      "electricity_usd_2026_kwh": 0.0991,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.04,
      "electricity": 7.73,
      "site_grid": 6.95,
      "operations": 36.59,
      "total": 152.3,
      "electricity_usd_2026_kwh": 0.0991,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.81,
      "electricity": 0.92,
      "site_grid": 1.44,
      "operations": 3.29,
      "total": 22.47,
      "electricity_usd_2026_kwh": 0.0964,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.16,
      "electricity": 1.18,
      "site_grid": 1.46,
      "operations": 6.58,
      "total": 30.38,
      "electricity_usd_2026_kwh": 0.0964,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.02,
      "electricity": 2.49,
      "site_grid": 3.09,
      "operations": 7.64,
      "total": 49.25,
      "electricity_usd_2026_kwh": 0.0964,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.33,
      "electricity": 3.19,
      "site_grid": 3.13,
      "operations": 15.32,
      "total": 66.97,
      "electricity_usd_2026_kwh": 0.0964,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.69,
      "electricity": 5.87,
      "site_grid": 6.84,
      "operations": 18.19,
      "total": 110.6,
      "electricity_usd_2026_kwh": 0.0964,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.29,
      "electricity": 7.52,
      "site_grid": 6.92,
      "operations": 36.59,
      "total": 151.31,
      "electricity_usd_2026_kwh": 0.0964,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.72,
      "electricity": 0.89,
      "site_grid": 1.4,
      "operations": 3.29,
      "total": 22.31,
      "electricity_usd_2026_kwh": 0.0931,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.04,
      "electricity": 1.14,
      "site_grid": 1.43,
      "operations": 6.58,
      "total": 30.19,
      "electricity_usd_2026_kwh": 0.0931,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.82,
      "electricity": 2.41,
      "site_grid": 3.01,
      "operations": 7.64,
      "total": 48.88,
      "electricity_usd_2026_kwh": 0.0931,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.08,
      "electricity": 3.08,
      "site_grid": 3.06,
      "operations": 15.32,
      "total": 66.54,
      "electricity_usd_2026_kwh": 0.0931,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.25,
      "electricity": 5.67,
      "site_grid": 6.66,
      "operations": 18.19,
      "total": 109.77,
      "electricity_usd_2026_kwh": 0.0931,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.73,
      "electricity": 7.26,
      "site_grid": 6.76,
      "operations": 36.59,
      "total": 150.34,
      "electricity_usd_2026_kwh": 0.0931,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.87,
      "electricity": 0.89,
      "site_grid": 1.46,
      "operations": 3.29,
      "total": 22.51,
      "electricity_usd_2026_kwh": 0.0928,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.23,
      "electricity": 1.13,
      "site_grid": 1.47,
      "operations": 6.58,
      "total": 30.42,
      "electricity_usd_2026_kwh": 0.0928,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.15,
      "electricity": 2.4,
      "site_grid": 3.12,
      "operations": 7.64,
      "total": 49.31,
      "electricity_usd_2026_kwh": 0.0928,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.49,
      "electricity": 3.07,
      "site_grid": 3.15,
      "operations": 15.32,
      "total": 67.04,
      "electricity_usd_2026_kwh": 0.0928,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.98,
      "electricity": 5.65,
      "site_grid": 6.91,
      "operations": 18.19,
      "total": 110.73,
      "electricity_usd_2026_kwh": 0.0928,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.64,
      "electricity": 7.24,
      "site_grid": 6.98,
      "operations": 36.59,
      "total": 151.44,
      "electricity_usd_2026_kwh": 0.0928,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.06,
      "electricity": 0.87,
      "site_grid": 1.55,
      "operations": 3.29,
      "total": 22.77,
      "electricity_usd_2026_kwh": 0.0911,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.46,
      "electricity": 1.11,
      "site_grid": 1.55,
      "operations": 6.58,
      "total": 30.71,
      "electricity_usd_2026_kwh": 0.0911,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.54,
      "electricity": 2.36,
      "site_grid": 3.32,
      "operations": 7.64,
      "total": 49.86,
      "electricity_usd_2026_kwh": 0.0911,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.98,
      "electricity": 3.02,
      "site_grid": 3.33,
      "operations": 15.32,
      "total": 67.65,
      "electricity_usd_2026_kwh": 0.0911,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.85,
      "electricity": 5.55,
      "site_grid": 7.34,
      "operations": 18.19,
      "total": 111.93,
      "electricity_usd_2026_kwh": 0.0911,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.73,
      "electricity": 7.1,
      "site_grid": 7.36,
      "operations": 36.59,
      "total": 152.78,
      "electricity_usd_2026_kwh": 0.0911,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.81,
      "electricity": 0.84,
      "site_grid": 1.53,
      "operations": 3.29,
      "total": 22.48,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.16,
      "electricity": 1.08,
      "site_grid": 1.55,
      "operations": 6.58,
      "total": 30.37,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.02,
      "electricity": 2.28,
      "site_grid": 3.28,
      "operations": 7.64,
      "total": 49.22,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.33,
      "electricity": 2.92,
      "site_grid": 3.32,
      "operations": 15.32,
      "total": 66.89,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.7,
      "electricity": 5.36,
      "site_grid": 7.26,
      "operations": 18.19,
      "total": 110.51,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.29,
      "electricity": 6.87,
      "site_grid": 7.34,
      "operations": 36.59,
      "total": 151.09,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.42,
      "electricity": 0.81,
      "site_grid": 1.43,
      "operations": 3.29,
      "total": 21.96,
      "electricity_usd_2026_kwh": 0.0852,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.67,
      "electricity": 1.04,
      "site_grid": 1.47,
      "operations": 6.58,
      "total": 29.76,
      "electricity_usd_2026_kwh": 0.0852,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.19,
      "electricity": 2.2,
      "site_grid": 3.06,
      "operations": 7.64,
      "total": 48.09,
      "electricity_usd_2026_kwh": 0.0852,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.28,
      "electricity": 2.82,
      "site_grid": 3.15,
      "operations": 15.32,
      "total": 65.57,
      "electricity_usd_2026_kwh": 0.0852,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.84,
      "electricity": 5.19,
      "site_grid": 6.76,
      "operations": 18.19,
      "total": 107.99,
      "electricity_usd_2026_kwh": 0.0852,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 97.97,
      "electricity": 6.64,
      "site_grid": 6.96,
      "operations": 36.59,
      "total": 148.17,
      "electricity_usd_2026_kwh": 0.0852,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.6,
      "electricity": 0.84,
      "site_grid": 1.49,
      "operations": 3.29,
      "total": 22.22,
      "electricity_usd_2026_kwh": 0.0876,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.89,
      "electricity": 1.07,
      "site_grid": 1.52,
      "operations": 6.58,
      "total": 30.06,
      "electricity_usd_2026_kwh": 0.0876,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.56,
      "electricity": 2.27,
      "site_grid": 3.2,
      "operations": 7.64,
      "total": 48.66,
      "electricity_usd_2026_kwh": 0.0876,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.75,
      "electricity": 2.9,
      "site_grid": 3.26,
      "operations": 15.32,
      "total": 66.24,
      "electricity_usd_2026_kwh": 0.0876,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.67,
      "electricity": 5.34,
      "site_grid": 7.07,
      "operations": 18.19,
      "total": 109.27,
      "electricity_usd_2026_kwh": 0.0876,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.0,
      "electricity": 6.83,
      "site_grid": 7.22,
      "operations": 36.59,
      "total": 149.65,
      "electricity_usd_2026_kwh": 0.0876,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.07,
      "electricity": 0.9,
      "site_grid": 1.87,
      "operations": 3.29,
      "total": 23.13,
      "electricity_usd_2026_kwh": 0.094,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.48,
      "electricity": 1.15,
      "site_grid": 1.87,
      "operations": 6.58,
      "total": 31.08,
      "electricity_usd_2026_kwh": 0.094,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.57,
      "electricity": 2.43,
      "site_grid": 4.01,
      "operations": 7.64,
      "total": 50.65,
      "electricity_usd_2026_kwh": 0.094,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.02,
      "electricity": 3.11,
      "site_grid": 4.02,
      "operations": 15.32,
      "total": 68.47,
      "electricity_usd_2026_kwh": 0.094,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.91,
      "electricity": 5.73,
      "site_grid": 8.87,
      "operations": 18.19,
      "total": 113.69,
      "electricity_usd_2026_kwh": 0.094,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.8,
      "electricity": 7.33,
      "site_grid": 8.88,
      "operations": 36.59,
      "total": 154.61,
      "electricity_usd_2026_kwh": 0.094,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.39,
      "electricity": 0.83,
      "site_grid": 2.06,
      "operations": 3.29,
      "total": 23.58,
      "electricity_usd_2026_kwh": 0.0872,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.88,
      "electricity": 1.07,
      "site_grid": 2.04,
      "operations": 6.58,
      "total": 31.57,
      "electricity_usd_2026_kwh": 0.0872,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.25,
      "electricity": 2.26,
      "site_grid": 4.42,
      "operations": 7.64,
      "total": 51.57,
      "electricity_usd_2026_kwh": 0.0872,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.87,
      "electricity": 2.89,
      "site_grid": 4.38,
      "operations": 15.32,
      "total": 69.46,
      "electricity_usd_2026_kwh": 0.0872,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.42,
      "electricity": 5.31,
      "site_grid": 9.78,
      "operations": 18.19,
      "total": 115.71,
      "electricity_usd_2026_kwh": 0.0872,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.69,
      "electricity": 6.8,
      "site_grid": 9.68,
      "operations": 36.59,
      "total": 156.77,
      "electricity_usd_2026_kwh": 0.0872,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.47,
      "electricity": 0.82,
      "site_grid": 2.03,
      "operations": 3.29,
      "total": 23.61,
      "electricity_usd_2026_kwh": 0.0857,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.97,
      "electricity": 1.05,
      "site_grid": 2.0,
      "operations": 6.58,
      "total": 31.61,
      "electricity_usd_2026_kwh": 0.0857,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.42,
      "electricity": 2.22,
      "site_grid": 4.35,
      "operations": 7.64,
      "total": 51.63,
      "electricity_usd_2026_kwh": 0.0857,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.08,
      "electricity": 2.84,
      "site_grid": 4.29,
      "operations": 15.32,
      "total": 69.53,
      "electricity_usd_2026_kwh": 0.0857,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.79,
      "electricity": 5.22,
      "site_grid": 9.62,
      "operations": 18.19,
      "total": 115.83,
      "electricity_usd_2026_kwh": 0.0857,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.16,
      "electricity": 6.68,
      "site_grid": 9.5,
      "operations": 36.59,
      "total": 156.93,
      "electricity_usd_2026_kwh": 0.0857,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.49,
      "electricity": 0.84,
      "site_grid": 2.02,
      "operations": 3.29,
      "total": 23.65,
      "electricity_usd_2026_kwh": 0.0885,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.01,
      "electricity": 1.08,
      "site_grid": 1.99,
      "operations": 6.58,
      "total": 31.66,
      "electricity_usd_2026_kwh": 0.0885,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.48,
      "electricity": 2.29,
      "site_grid": 4.32,
      "operations": 7.64,
      "total": 51.73,
      "electricity_usd_2026_kwh": 0.0885,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.15,
      "electricity": 2.93,
      "site_grid": 4.26,
      "operations": 15.32,
      "total": 69.66,
      "electricity_usd_2026_kwh": 0.0885,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.92,
      "electricity": 5.39,
      "site_grid": 9.55,
      "operations": 18.19,
      "total": 116.06,
      "electricity_usd_2026_kwh": 0.0885,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.32,
      "electricity": 6.9,
      "site_grid": 9.42,
      "operations": 36.59,
      "total": 157.23,
      "electricity_usd_2026_kwh": 0.0885,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "EIA observed",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.51,
      "electricity": 0.82,
      "site_grid": 2.03,
      "operations": 3.29,
      "total": 23.65,
      "electricity_usd_2026_kwh": 0.0862,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.02,
      "electricity": 1.05,
      "site_grid": 2.0,
      "operations": 6.58,
      "total": 31.66,
      "electricity_usd_2026_kwh": 0.0862,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.51,
      "electricity": 2.23,
      "site_grid": 4.34,
      "operations": 7.64,
      "total": 51.72,
      "electricity_usd_2026_kwh": 0.0862,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.19,
      "electricity": 2.86,
      "site_grid": 4.28,
      "operations": 15.32,
      "total": 69.64,
      "electricity_usd_2026_kwh": 0.0862,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.98,
      "electricity": 5.25,
      "site_grid": 9.6,
      "operations": 18.19,
      "total": 116.02,
      "electricity_usd_2026_kwh": 0.0862,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "US",
      "country": "United States",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.39,
      "electricity": 6.73,
      "site_grid": 9.46,
      "operations": 36.59,
      "total": 157.17,
      "electricity_usd_2026_kwh": 0.0862,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.5,
      "electricity": 0.9,
      "site_grid": 1.41,
      "operations": 3.29,
      "total": 23.09,
      "electricity_usd_2026_kwh": 0.0984,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.0,
      "electricity": 1.15,
      "site_grid": 1.37,
      "operations": 6.39,
      "total": 30.91,
      "electricity_usd_2026_kwh": 0.0984,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.49,
      "electricity": 2.43,
      "site_grid": 3.02,
      "operations": 7.63,
      "total": 50.57,
      "electricity_usd_2026_kwh": 0.0984,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.14,
      "electricity": 3.11,
      "site_grid": 2.94,
      "operations": 14.9,
      "total": 68.1,
      "electricity_usd_2026_kwh": 0.0984,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.94,
      "electricity": 5.72,
      "site_grid": 6.68,
      "operations": 18.16,
      "total": 113.51,
      "electricity_usd_2026_kwh": 0.0984,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.3,
      "electricity": 7.33,
      "site_grid": 6.51,
      "operations": 35.65,
      "total": 153.79,
      "electricity_usd_2026_kwh": 0.0984,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.36,
      "electricity": 0.88,
      "site_grid": 1.35,
      "operations": 3.29,
      "total": 22.87,
      "electricity_usd_2026_kwh": 0.0961,
      "wacc": 0.0595,
      "construction_real_factor": 0.78459,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.83,
      "electricity": 1.12,
      "site_grid": 1.32,
      "operations": 6.39,
      "total": 30.66,
      "electricity_usd_2026_kwh": 0.0961,
      "wacc": 0.0595,
      "construction_real_factor": 0.78459,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.19,
      "electricity": 2.37,
      "site_grid": 2.9,
      "operations": 7.63,
      "total": 50.08,
      "electricity_usd_2026_kwh": 0.0961,
      "wacc": 0.0595,
      "construction_real_factor": 0.78459,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.77,
      "electricity": 3.04,
      "site_grid": 2.83,
      "operations": 14.9,
      "total": 67.54,
      "electricity_usd_2026_kwh": 0.0961,
      "wacc": 0.0595,
      "construction_real_factor": 0.78459,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.27,
      "electricity": 5.59,
      "site_grid": 6.41,
      "operations": 18.16,
      "total": 112.43,
      "electricity_usd_2026_kwh": 0.0961,
      "wacc": 0.0595,
      "construction_real_factor": 0.78459,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.47,
      "electricity": 7.16,
      "site_grid": 6.27,
      "operations": 35.65,
      "total": 152.55,
      "electricity_usd_2026_kwh": 0.0961,
      "wacc": 0.0595,
      "construction_real_factor": 0.78459,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.04,
      "electricity": 0.84,
      "site_grid": 1.27,
      "operations": 3.29,
      "total": 22.44,
      "electricity_usd_2026_kwh": 0.0921,
      "wacc": 0.0497,
      "construction_real_factor": 0.7887,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.43,
      "electricity": 1.07,
      "site_grid": 1.26,
      "operations": 6.39,
      "total": 30.16,
      "electricity_usd_2026_kwh": 0.0921,
      "wacc": 0.0497,
      "construction_real_factor": 0.7887,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.51,
      "electricity": 2.27,
      "site_grid": 2.72,
      "operations": 7.63,
      "total": 49.13,
      "electricity_usd_2026_kwh": 0.0921,
      "wacc": 0.0497,
      "construction_real_factor": 0.7887,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.92,
      "electricity": 2.91,
      "site_grid": 2.7,
      "operations": 14.9,
      "total": 66.43,
      "electricity_usd_2026_kwh": 0.0921,
      "wacc": 0.0497,
      "construction_real_factor": 0.7887,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.78,
      "electricity": 5.36,
      "site_grid": 6.02,
      "operations": 18.16,
      "total": 110.32,
      "electricity_usd_2026_kwh": 0.0921,
      "wacc": 0.0497,
      "construction_real_factor": 0.7887,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.6,
      "electricity": 6.86,
      "site_grid": 5.97,
      "operations": 35.65,
      "total": 150.08,
      "electricity_usd_2026_kwh": 0.0921,
      "wacc": 0.0497,
      "construction_real_factor": 0.7887,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.22,
      "electricity": 0.85,
      "site_grid": 1.33,
      "operations": 3.29,
      "total": 22.69,
      "electricity_usd_2026_kwh": 0.0937,
      "wacc": 0.0552,
      "construction_real_factor": 0.79534,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.65,
      "electricity": 1.09,
      "site_grid": 1.31,
      "operations": 6.39,
      "total": 30.45,
      "electricity_usd_2026_kwh": 0.0937,
      "wacc": 0.0552,
      "construction_real_factor": 0.79534,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.89,
      "electricity": 2.32,
      "site_grid": 2.85,
      "operations": 7.63,
      "total": 49.68,
      "electricity_usd_2026_kwh": 0.0937,
      "wacc": 0.0552,
      "construction_real_factor": 0.79534,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.39,
      "electricity": 2.97,
      "site_grid": 2.81,
      "operations": 14.9,
      "total": 67.07,
      "electricity_usd_2026_kwh": 0.0937,
      "wacc": 0.0552,
      "construction_real_factor": 0.79534,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.61,
      "electricity": 5.45,
      "site_grid": 6.31,
      "operations": 18.16,
      "total": 111.53,
      "electricity_usd_2026_kwh": 0.0937,
      "wacc": 0.0552,
      "construction_real_factor": 0.79534,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.64,
      "electricity": 6.99,
      "site_grid": 6.21,
      "operations": 35.65,
      "total": 151.49,
      "electricity_usd_2026_kwh": 0.0937,
      "wacc": 0.0552,
      "construction_real_factor": 0.79534,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.28,
      "electricity": 0.87,
      "site_grid": 1.37,
      "operations": 3.29,
      "total": 22.8,
      "electricity_usd_2026_kwh": 0.0951,
      "wacc": 0.0571,
      "construction_real_factor": 0.80787,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.73,
      "electricity": 1.11,
      "site_grid": 1.34,
      "operations": 6.39,
      "total": 30.57,
      "electricity_usd_2026_kwh": 0.0951,
      "wacc": 0.0571,
      "construction_real_factor": 0.80787,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.02,
      "electricity": 2.35,
      "site_grid": 2.93,
      "operations": 7.63,
      "total": 49.93,
      "electricity_usd_2026_kwh": 0.0951,
      "wacc": 0.0571,
      "construction_real_factor": 0.80787,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.56,
      "electricity": 3.01,
      "site_grid": 2.88,
      "operations": 14.9,
      "total": 67.35,
      "electricity_usd_2026_kwh": 0.0951,
      "wacc": 0.0571,
      "construction_real_factor": 0.80787,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.9,
      "electricity": 5.53,
      "site_grid": 6.49,
      "operations": 18.16,
      "total": 112.08,
      "electricity_usd_2026_kwh": 0.0951,
      "wacc": 0.0571,
      "construction_real_factor": 0.80787,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.0,
      "electricity": 7.08,
      "site_grid": 6.37,
      "operations": 35.65,
      "total": 152.11,
      "electricity_usd_2026_kwh": 0.0951,
      "wacc": 0.0571,
      "construction_real_factor": 0.80787,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.15,
      "electricity": 0.84,
      "site_grid": 1.36,
      "operations": 3.29,
      "total": 22.63,
      "electricity_usd_2026_kwh": 0.0924,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.57,
      "electricity": 1.08,
      "site_grid": 1.34,
      "operations": 6.39,
      "total": 30.37,
      "electricity_usd_2026_kwh": 0.0924,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.74,
      "electricity": 2.28,
      "site_grid": 2.9,
      "operations": 7.63,
      "total": 49.56,
      "electricity_usd_2026_kwh": 0.0924,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.21,
      "electricity": 2.92,
      "site_grid": 2.87,
      "operations": 14.9,
      "total": 66.9,
      "electricity_usd_2026_kwh": 0.0924,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.29,
      "electricity": 5.38,
      "site_grid": 6.43,
      "operations": 18.16,
      "total": 111.25,
      "electricity_usd_2026_kwh": 0.0924,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.24,
      "electricity": 6.89,
      "site_grid": 6.34,
      "operations": 35.65,
      "total": 151.12,
      "electricity_usd_2026_kwh": 0.0924,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.05,
      "electricity": 0.81,
      "site_grid": 1.32,
      "operations": 3.29,
      "total": 22.47,
      "electricity_usd_2026_kwh": 0.0893,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.45,
      "electricity": 1.04,
      "site_grid": 1.31,
      "operations": 6.39,
      "total": 30.18,
      "electricity_usd_2026_kwh": 0.0893,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.54,
      "electricity": 2.21,
      "site_grid": 2.83,
      "operations": 7.63,
      "total": 49.19,
      "electricity_usd_2026_kwh": 0.0893,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.95,
      "electricity": 2.83,
      "site_grid": 2.8,
      "operations": 14.9,
      "total": 66.48,
      "electricity_usd_2026_kwh": 0.0893,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.83,
      "electricity": 5.19,
      "site_grid": 6.25,
      "operations": 18.16,
      "total": 110.44,
      "electricity_usd_2026_kwh": 0.0893,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.66,
      "electricity": 6.65,
      "site_grid": 6.2,
      "operations": 35.65,
      "total": 150.16,
      "electricity_usd_2026_kwh": 0.0893,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.21,
      "electricity": 0.81,
      "site_grid": 1.37,
      "operations": 3.29,
      "total": 22.68,
      "electricity_usd_2026_kwh": 0.089,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.65,
      "electricity": 1.04,
      "site_grid": 1.35,
      "operations": 6.39,
      "total": 30.42,
      "electricity_usd_2026_kwh": 0.089,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.87,
      "electricity": 2.2,
      "site_grid": 2.94,
      "operations": 7.63,
      "total": 49.63,
      "electricity_usd_2026_kwh": 0.089,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.38,
      "electricity": 2.82,
      "site_grid": 2.89,
      "operations": 14.9,
      "total": 66.98,
      "electricity_usd_2026_kwh": 0.089,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.58,
      "electricity": 5.18,
      "site_grid": 6.49,
      "operations": 18.16,
      "total": 111.41,
      "electricity_usd_2026_kwh": 0.089,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.6,
      "electricity": 6.63,
      "site_grid": 6.39,
      "operations": 35.65,
      "total": 151.28,
      "electricity_usd_2026_kwh": 0.089,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.4,
      "electricity": 0.8,
      "site_grid": 1.46,
      "operations": 3.29,
      "total": 22.94,
      "electricity_usd_2026_kwh": 0.0873,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.88,
      "electricity": 1.02,
      "site_grid": 1.42,
      "operations": 6.39,
      "total": 30.71,
      "electricity_usd_2026_kwh": 0.0873,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.28,
      "electricity": 2.16,
      "site_grid": 3.12,
      "operations": 7.63,
      "total": 50.18,
      "electricity_usd_2026_kwh": 0.0873,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.88,
      "electricity": 2.76,
      "site_grid": 3.05,
      "operations": 14.9,
      "total": 67.6,
      "electricity_usd_2026_kwh": 0.0873,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.47,
      "electricity": 5.08,
      "site_grid": 6.91,
      "operations": 18.16,
      "total": 112.62,
      "electricity_usd_2026_kwh": 0.0873,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.71,
      "electricity": 6.51,
      "site_grid": 6.75,
      "operations": 35.65,
      "total": 152.63,
      "electricity_usd_2026_kwh": 0.0873,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.15,
      "electricity": 0.77,
      "site_grid": 1.44,
      "operations": 3.29,
      "total": 22.65,
      "electricity_usd_2026_kwh": 0.0844,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.57,
      "electricity": 0.99,
      "site_grid": 1.42,
      "operations": 6.39,
      "total": 30.36,
      "electricity_usd_2026_kwh": 0.0844,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.74,
      "electricity": 2.09,
      "site_grid": 3.08,
      "operations": 7.63,
      "total": 49.54,
      "electricity_usd_2026_kwh": 0.0844,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.21,
      "electricity": 2.67,
      "site_grid": 3.04,
      "operations": 14.9,
      "total": 66.83,
      "electricity_usd_2026_kwh": 0.0844,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.29,
      "electricity": 4.91,
      "site_grid": 6.82,
      "operations": 18.16,
      "total": 111.19,
      "electricity_usd_2026_kwh": 0.0844,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.24,
      "electricity": 6.29,
      "site_grid": 6.73,
      "operations": 35.65,
      "total": 150.92,
      "electricity_usd_2026_kwh": 0.0844,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.75,
      "electricity": 0.74,
      "site_grid": 1.34,
      "operations": 3.29,
      "total": 22.12,
      "electricity_usd_2026_kwh": 0.0817,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.07,
      "electricity": 0.95,
      "site_grid": 1.35,
      "operations": 6.39,
      "total": 29.75,
      "electricity_usd_2026_kwh": 0.0817,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.88,
      "electricity": 2.02,
      "site_grid": 2.87,
      "operations": 7.63,
      "total": 48.4,
      "electricity_usd_2026_kwh": 0.0817,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.14,
      "electricity": 2.58,
      "site_grid": 2.88,
      "operations": 14.9,
      "total": 65.5,
      "electricity_usd_2026_kwh": 0.0817,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.39,
      "electricity": 4.75,
      "site_grid": 6.35,
      "operations": 18.16,
      "total": 108.65,
      "electricity_usd_2026_kwh": 0.0817,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.86,
      "electricity": 6.09,
      "site_grid": 6.38,
      "operations": 35.65,
      "total": 147.97,
      "electricity_usd_2026_kwh": 0.0817,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.93,
      "electricity": 0.77,
      "site_grid": 1.4,
      "operations": 3.29,
      "total": 22.38,
      "electricity_usd_2026_kwh": 0.084,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.29,
      "electricity": 0.98,
      "site_grid": 1.4,
      "operations": 6.39,
      "total": 30.05,
      "electricity_usd_2026_kwh": 0.084,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.27,
      "electricity": 2.07,
      "site_grid": 3.0,
      "operations": 7.63,
      "total": 48.97,
      "electricity_usd_2026_kwh": 0.084,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.62,
      "electricity": 2.66,
      "site_grid": 2.99,
      "operations": 14.9,
      "total": 66.16,
      "electricity_usd_2026_kwh": 0.084,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.24,
      "electricity": 4.89,
      "site_grid": 6.64,
      "operations": 18.16,
      "total": 109.92,
      "electricity_usd_2026_kwh": 0.084,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.92,
      "electricity": 6.26,
      "site_grid": 6.62,
      "operations": 35.65,
      "total": 149.45,
      "electricity_usd_2026_kwh": 0.084,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.41,
      "electricity": 0.82,
      "site_grid": 1.76,
      "operations": 3.29,
      "total": 23.28,
      "electricity_usd_2026_kwh": 0.0901,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.9,
      "electricity": 1.05,
      "site_grid": 1.72,
      "operations": 6.39,
      "total": 31.06,
      "electricity_usd_2026_kwh": 0.0901,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.31,
      "electricity": 2.23,
      "site_grid": 3.77,
      "operations": 7.63,
      "total": 50.93,
      "electricity_usd_2026_kwh": 0.0901,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.91,
      "electricity": 2.85,
      "site_grid": 3.68,
      "operations": 14.9,
      "total": 68.35,
      "electricity_usd_2026_kwh": 0.0901,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.53,
      "electricity": 5.24,
      "site_grid": 8.34,
      "operations": 18.16,
      "total": 114.28,
      "electricity_usd_2026_kwh": 0.0901,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.79,
      "electricity": 6.72,
      "site_grid": 8.15,
      "operations": 35.65,
      "total": 154.31,
      "electricity_usd_2026_kwh": 0.0901,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.74,
      "electricity": 0.76,
      "site_grid": 1.94,
      "operations": 3.29,
      "total": 23.73,
      "electricity_usd_2026_kwh": 0.0836,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.31,
      "electricity": 0.98,
      "site_grid": 1.88,
      "operations": 6.39,
      "total": 31.54,
      "electricity_usd_2026_kwh": 0.0836,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.01,
      "electricity": 2.07,
      "site_grid": 4.16,
      "operations": 7.63,
      "total": 51.86,
      "electricity_usd_2026_kwh": 0.0836,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.79,
      "electricity": 2.65,
      "site_grid": 4.02,
      "operations": 14.9,
      "total": 69.35,
      "electricity_usd_2026_kwh": 0.0836,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.08,
      "electricity": 4.87,
      "site_grid": 9.21,
      "operations": 18.16,
      "total": 116.32,
      "electricity_usd_2026_kwh": 0.0836,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.73,
      "electricity": 6.23,
      "site_grid": 8.89,
      "operations": 35.65,
      "total": 156.5,
      "electricity_usd_2026_kwh": 0.0836,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.82,
      "electricity": 0.75,
      "site_grid": 1.91,
      "operations": 3.29,
      "total": 23.77,
      "electricity_usd_2026_kwh": 0.0821,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.41,
      "electricity": 0.96,
      "site_grid": 1.84,
      "operations": 6.39,
      "total": 31.59,
      "electricity_usd_2026_kwh": 0.0821,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.18,
      "electricity": 2.03,
      "site_grid": 4.1,
      "operations": 7.63,
      "total": 51.93,
      "electricity_usd_2026_kwh": 0.0821,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.01,
      "electricity": 2.6,
      "site_grid": 3.94,
      "operations": 14.9,
      "total": 69.45,
      "electricity_usd_2026_kwh": 0.0821,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.47,
      "electricity": 4.78,
      "site_grid": 9.06,
      "operations": 18.16,
      "total": 116.47,
      "electricity_usd_2026_kwh": 0.0821,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.21,
      "electricity": 6.12,
      "site_grid": 8.72,
      "operations": 35.65,
      "total": 156.7,
      "electricity_usd_2026_kwh": 0.0821,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.85,
      "electricity": 0.77,
      "site_grid": 1.9,
      "operations": 3.29,
      "total": 23.81,
      "electricity_usd_2026_kwh": 0.0849,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.44,
      "electricity": 0.99,
      "site_grid": 1.82,
      "operations": 6.39,
      "total": 31.64,
      "electricity_usd_2026_kwh": 0.0849,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.24,
      "electricity": 2.1,
      "site_grid": 4.07,
      "operations": 7.63,
      "total": 52.03,
      "electricity_usd_2026_kwh": 0.0849,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.08,
      "electricity": 2.69,
      "site_grid": 3.91,
      "operations": 14.9,
      "total": 69.58,
      "electricity_usd_2026_kwh": 0.0849,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.6,
      "electricity": 4.94,
      "site_grid": 9.0,
      "operations": 18.16,
      "total": 116.69,
      "electricity_usd_2026_kwh": 0.0849,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.37,
      "electricity": 6.32,
      "site_grid": 8.65,
      "operations": 35.65,
      "total": 157.0,
      "electricity_usd_2026_kwh": 0.0849,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.86,
      "electricity": 0.77,
      "site_grid": 1.91,
      "operations": 3.29,
      "total": 23.83,
      "electricity_usd_2026_kwh": 0.0849,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.46,
      "electricity": 0.99,
      "site_grid": 1.83,
      "operations": 6.39,
      "total": 31.67,
      "electricity_usd_2026_kwh": 0.0849,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.27,
      "electricity": 2.1,
      "site_grid": 4.09,
      "operations": 7.63,
      "total": 52.08,
      "electricity_usd_2026_kwh": 0.0849,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.12,
      "electricity": 2.69,
      "site_grid": 3.93,
      "operations": 14.9,
      "total": 69.63,
      "electricity_usd_2026_kwh": 0.0849,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.66,
      "electricity": 4.94,
      "site_grid": 9.04,
      "operations": 18.16,
      "total": 116.8,
      "electricity_usd_2026_kwh": 0.0849,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.45,
      "electricity": 6.32,
      "site_grid": 8.69,
      "operations": 35.65,
      "total": 157.11,
      "electricity_usd_2026_kwh": 0.0849,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.35,
      "electricity": 1.5,
      "site_grid": 1.68,
      "operations": 3.33,
      "total": 26.85,
      "electricity_usd_2026_kwh": 0.1502,
      "wacc": 0.1088,
      "construction_real_factor": 0.79525,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.73,
      "electricity": 1.93,
      "site_grid": 1.48,
      "operations": 5.53,
      "total": 34.67,
      "electricity_usd_2026_kwh": 0.1502,
      "wacc": 0.1088,
      "construction_real_factor": 0.79525,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 43.59,
      "electricity": 4.08,
      "site_grid": 3.59,
      "operations": 7.71,
      "total": 58.97,
      "electricity_usd_2026_kwh": 0.1502,
      "wacc": 0.1088,
      "construction_real_factor": 0.79525,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 55.13,
      "electricity": 5.24,
      "site_grid": 3.18,
      "operations": 13.07,
      "total": 76.61,
      "electricity_usd_2026_kwh": 0.1502,
      "wacc": 0.1088,
      "construction_real_factor": 0.79525,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 96.44,
      "electricity": 9.6,
      "site_grid": 7.95,
      "operations": 18.35,
      "total": 132.34,
      "electricity_usd_2026_kwh": 0.1502,
      "wacc": 0.1088,
      "construction_real_factor": 0.79525,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 121.96,
      "electricity": 12.34,
      "site_grid": 7.03,
      "operations": 31.63,
      "total": 172.95,
      "electricity_usd_2026_kwh": 0.1502,
      "wacc": 0.1088,
      "construction_real_factor": 0.79525,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.19,
      "electricity": 1.47,
      "site_grid": 1.61,
      "operations": 3.33,
      "total": 26.6,
      "electricity_usd_2026_kwh": 0.1467,
      "wacc": 0.1045,
      "construction_real_factor": 0.78459,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.54,
      "electricity": 1.89,
      "site_grid": 1.43,
      "operations": 5.53,
      "total": 34.38,
      "electricity_usd_2026_kwh": 0.1467,
      "wacc": 0.1045,
      "construction_real_factor": 0.78459,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 43.26,
      "electricity": 3.98,
      "site_grid": 3.46,
      "operations": 7.71,
      "total": 58.41,
      "electricity_usd_2026_kwh": 0.1467,
      "wacc": 0.1045,
      "construction_real_factor": 0.78459,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 54.71,
      "electricity": 5.12,
      "site_grid": 3.07,
      "operations": 13.07,
      "total": 75.97,
      "electricity_usd_2026_kwh": 0.1467,
      "wacc": 0.1045,
      "construction_real_factor": 0.78459,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 95.71,
      "electricity": 9.37,
      "site_grid": 7.65,
      "operations": 18.35,
      "total": 131.08,
      "electricity_usd_2026_kwh": 0.1467,
      "wacc": 0.1045,
      "construction_real_factor": 0.78459,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 121.04,
      "electricity": 12.05,
      "site_grid": 6.79,
      "operations": 31.63,
      "total": 171.51,
      "electricity_usd_2026_kwh": 0.1467,
      "wacc": 0.1045,
      "construction_real_factor": 0.78459,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.84,
      "electricity": 1.41,
      "site_grid": 1.53,
      "operations": 3.33,
      "total": 26.11,
      "electricity_usd_2026_kwh": 0.1406,
      "wacc": 0.0947,
      "construction_real_factor": 0.7887,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.1,
      "electricity": 1.81,
      "site_grid": 1.37,
      "operations": 5.53,
      "total": 33.81,
      "electricity_usd_2026_kwh": 0.1406,
      "wacc": 0.0947,
      "construction_real_factor": 0.7887,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.52,
      "electricity": 3.81,
      "site_grid": 3.28,
      "operations": 7.71,
      "total": 57.32,
      "electricity_usd_2026_kwh": 0.1406,
      "wacc": 0.0947,
      "construction_real_factor": 0.7887,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.78,
      "electricity": 4.9,
      "site_grid": 2.94,
      "operations": 13.07,
      "total": 74.69,
      "electricity_usd_2026_kwh": 0.1406,
      "wacc": 0.0947,
      "construction_real_factor": 0.7887,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.06,
      "electricity": 8.98,
      "site_grid": 7.26,
      "operations": 18.35,
      "total": 128.65,
      "electricity_usd_2026_kwh": 0.1406,
      "wacc": 0.0947,
      "construction_real_factor": 0.7887,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 118.97,
      "electricity": 11.55,
      "site_grid": 6.51,
      "operations": 31.63,
      "total": 168.65,
      "electricity_usd_2026_kwh": 0.1406,
      "wacc": 0.0947,
      "construction_real_factor": 0.7887,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.04,
      "electricity": 1.43,
      "site_grid": 1.59,
      "operations": 3.33,
      "total": 26.39,
      "electricity_usd_2026_kwh": 0.1431,
      "wacc": 0.1002,
      "construction_real_factor": 0.79534,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.34,
      "electricity": 1.84,
      "site_grid": 1.42,
      "operations": 5.53,
      "total": 34.13,
      "electricity_usd_2026_kwh": 0.1431,
      "wacc": 0.1002,
      "construction_real_factor": 0.79534,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.93,
      "electricity": 3.88,
      "site_grid": 3.42,
      "operations": 7.71,
      "total": 57.94,
      "electricity_usd_2026_kwh": 0.1431,
      "wacc": 0.1002,
      "construction_real_factor": 0.79534,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 54.3,
      "electricity": 4.99,
      "site_grid": 3.05,
      "operations": 13.07,
      "total": 75.41,
      "electricity_usd_2026_kwh": 0.1431,
      "wacc": 0.1002,
      "construction_real_factor": 0.79534,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.98,
      "electricity": 9.14,
      "site_grid": 7.56,
      "operations": 18.35,
      "total": 130.04,
      "electricity_usd_2026_kwh": 0.1431,
      "wacc": 0.1002,
      "construction_real_factor": 0.79534,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 120.13,
      "electricity": 11.76,
      "site_grid": 6.74,
      "operations": 31.63,
      "total": 170.25,
      "electricity_usd_2026_kwh": 0.1431,
      "wacc": 0.1002,
      "construction_real_factor": 0.79534,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.11,
      "electricity": 1.45,
      "site_grid": 1.64,
      "operations": 3.33,
      "total": 26.52,
      "electricity_usd_2026_kwh": 0.1452,
      "wacc": 0.1021,
      "construction_real_factor": 0.80787,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.43,
      "electricity": 1.87,
      "site_grid": 1.46,
      "operations": 5.53,
      "total": 34.28,
      "electricity_usd_2026_kwh": 0.1452,
      "wacc": 0.1021,
      "construction_real_factor": 0.80787,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 43.08,
      "electricity": 3.94,
      "site_grid": 3.51,
      "operations": 7.71,
      "total": 58.23,
      "electricity_usd_2026_kwh": 0.1452,
      "wacc": 0.1021,
      "construction_real_factor": 0.80787,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 54.48,
      "electricity": 5.06,
      "site_grid": 3.12,
      "operations": 13.07,
      "total": 75.73,
      "electricity_usd_2026_kwh": 0.1452,
      "wacc": 0.1021,
      "construction_real_factor": 0.80787,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 95.3,
      "electricity": 9.27,
      "site_grid": 7.76,
      "operations": 18.35,
      "total": 130.69,
      "electricity_usd_2026_kwh": 0.1452,
      "wacc": 0.1021,
      "construction_real_factor": 0.80787,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 120.53,
      "electricity": 11.92,
      "site_grid": 6.91,
      "operations": 31.63,
      "total": 170.99,
      "electricity_usd_2026_kwh": 0.1452,
      "wacc": 0.1021,
      "construction_real_factor": 0.80787,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.96,
      "electricity": 1.41,
      "site_grid": 1.63,
      "operations": 3.33,
      "total": 26.33,
      "electricity_usd_2026_kwh": 0.1411,
      "wacc": 0.0981,
      "construction_real_factor": 0.82253,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.25,
      "electricity": 1.82,
      "site_grid": 1.46,
      "operations": 5.53,
      "total": 34.05,
      "electricity_usd_2026_kwh": 0.1411,
      "wacc": 0.0981,
      "construction_real_factor": 0.82253,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.77,
      "electricity": 3.83,
      "site_grid": 3.49,
      "operations": 7.71,
      "total": 57.8,
      "electricity_usd_2026_kwh": 0.1411,
      "wacc": 0.0981,
      "construction_real_factor": 0.82253,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 54.1,
      "electricity": 4.92,
      "site_grid": 3.12,
      "operations": 13.07,
      "total": 75.2,
      "electricity_usd_2026_kwh": 0.1411,
      "wacc": 0.0981,
      "construction_real_factor": 0.82253,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.63,
      "electricity": 9.01,
      "site_grid": 7.72,
      "operations": 18.35,
      "total": 129.71,
      "electricity_usd_2026_kwh": 0.1411,
      "wacc": 0.0981,
      "construction_real_factor": 0.82253,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 119.68,
      "electricity": 11.59,
      "site_grid": 6.9,
      "operations": 31.63,
      "total": 169.79,
      "electricity_usd_2026_kwh": 0.1411,
      "wacc": 0.0981,
      "construction_real_factor": 0.82253,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.86,
      "electricity": 1.36,
      "site_grid": 1.59,
      "operations": 3.33,
      "total": 26.14,
      "electricity_usd_2026_kwh": 0.1363,
      "wacc": 0.0951,
      "construction_real_factor": 0.81728,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.11,
      "electricity": 1.75,
      "site_grid": 1.42,
      "operations": 5.53,
      "total": 33.82,
      "electricity_usd_2026_kwh": 0.1363,
      "wacc": 0.0951,
      "construction_real_factor": 0.81728,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.54,
      "electricity": 3.7,
      "site_grid": 3.41,
      "operations": 7.71,
      "total": 57.36,
      "electricity_usd_2026_kwh": 0.1363,
      "wacc": 0.0951,
      "construction_real_factor": 0.81728,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.81,
      "electricity": 4.75,
      "site_grid": 3.05,
      "operations": 13.07,
      "total": 74.68,
      "electricity_usd_2026_kwh": 0.1363,
      "wacc": 0.0951,
      "construction_real_factor": 0.81728,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.12,
      "electricity": 8.71,
      "site_grid": 7.53,
      "operations": 18.35,
      "total": 128.72,
      "electricity_usd_2026_kwh": 0.1363,
      "wacc": 0.0951,
      "construction_real_factor": 0.81728,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 119.04,
      "electricity": 11.2,
      "site_grid": 6.75,
      "operations": 31.63,
      "total": 168.62,
      "electricity_usd_2026_kwh": 0.1363,
      "wacc": 0.0951,
      "construction_real_factor": 0.81728,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.03,
      "electricity": 1.36,
      "site_grid": 1.64,
      "operations": 3.33,
      "total": 26.36,
      "electricity_usd_2026_kwh": 0.1358,
      "wacc": 0.1,
      "construction_real_factor": 0.82039,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.33,
      "electricity": 1.75,
      "site_grid": 1.47,
      "operations": 5.53,
      "total": 34.07,
      "electricity_usd_2026_kwh": 0.1358,
      "wacc": 0.1,
      "construction_real_factor": 0.82039,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.92,
      "electricity": 3.68,
      "site_grid": 3.52,
      "operations": 7.71,
      "total": 57.83,
      "electricity_usd_2026_kwh": 0.1358,
      "wacc": 0.1,
      "construction_real_factor": 0.82039,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 54.28,
      "electricity": 4.74,
      "site_grid": 3.14,
      "operations": 13.07,
      "total": 75.22,
      "electricity_usd_2026_kwh": 0.1358,
      "wacc": 0.1,
      "construction_real_factor": 0.82039,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.95,
      "electricity": 8.68,
      "site_grid": 7.79,
      "operations": 18.35,
      "total": 129.76,
      "electricity_usd_2026_kwh": 0.1358,
      "wacc": 0.1,
      "construction_real_factor": 0.82039,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 120.08,
      "electricity": 11.16,
      "site_grid": 6.95,
      "operations": 31.63,
      "total": 169.81,
      "electricity_usd_2026_kwh": 0.1358,
      "wacc": 0.1,
      "construction_real_factor": 0.82039,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.24,
      "electricity": 1.33,
      "site_grid": 1.74,
      "operations": 3.33,
      "total": 26.64,
      "electricity_usd_2026_kwh": 0.1334,
      "wacc": 0.1058,
      "construction_real_factor": 0.8388,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.59,
      "electricity": 1.72,
      "site_grid": 1.54,
      "operations": 5.53,
      "total": 34.38,
      "electricity_usd_2026_kwh": 0.1334,
      "wacc": 0.1058,
      "construction_real_factor": 0.8388,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 43.36,
      "electricity": 3.62,
      "site_grid": 3.72,
      "operations": 7.71,
      "total": 58.41,
      "electricity_usd_2026_kwh": 0.1334,
      "wacc": 0.1058,
      "construction_real_factor": 0.8388,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 54.83,
      "electricity": 4.65,
      "site_grid": 3.3,
      "operations": 13.07,
      "total": 75.86,
      "electricity_usd_2026_kwh": 0.1334,
      "wacc": 0.1058,
      "construction_real_factor": 0.8388,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 95.93,
      "electricity": 8.52,
      "site_grid": 8.24,
      "operations": 18.35,
      "total": 131.04,
      "electricity_usd_2026_kwh": 0.1334,
      "wacc": 0.1058,
      "construction_real_factor": 0.8388,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 121.31,
      "electricity": 10.95,
      "site_grid": 7.31,
      "operations": 31.63,
      "total": 171.2,
      "electricity_usd_2026_kwh": 0.1334,
      "wacc": 0.1058,
      "construction_real_factor": 0.8388,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.96,
      "electricity": 1.29,
      "site_grid": 1.73,
      "operations": 3.33,
      "total": 26.31,
      "electricity_usd_2026_kwh": 0.1289,
      "wacc": 0.0981,
      "construction_real_factor": 0.87274,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.25,
      "electricity": 1.66,
      "site_grid": 1.54,
      "operations": 5.53,
      "total": 33.98,
      "electricity_usd_2026_kwh": 0.1289,
      "wacc": 0.0981,
      "construction_real_factor": 0.87274,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.77,
      "electricity": 3.5,
      "site_grid": 3.7,
      "operations": 7.71,
      "total": 57.68,
      "electricity_usd_2026_kwh": 0.1289,
      "wacc": 0.0981,
      "construction_real_factor": 0.87274,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 54.1,
      "electricity": 4.5,
      "site_grid": 3.31,
      "operations": 13.07,
      "total": 74.97,
      "electricity_usd_2026_kwh": 0.1289,
      "wacc": 0.0981,
      "construction_real_factor": 0.87274,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.63,
      "electricity": 8.24,
      "site_grid": 8.19,
      "operations": 18.35,
      "total": 129.41,
      "electricity_usd_2026_kwh": 0.1289,
      "wacc": 0.0981,
      "construction_real_factor": 0.87274,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 119.68,
      "electricity": 10.59,
      "site_grid": 7.32,
      "operations": 31.63,
      "total": 169.22,
      "electricity_usd_2026_kwh": 0.1289,
      "wacc": 0.0981,
      "construction_real_factor": 0.87274,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.52,
      "electricity": 1.25,
      "site_grid": 1.63,
      "operations": 3.33,
      "total": 25.72,
      "electricity_usd_2026_kwh": 0.1247,
      "wacc": 0.0856,
      "construction_real_factor": 0.88762,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.69,
      "electricity": 1.6,
      "site_grid": 1.48,
      "operations": 5.53,
      "total": 33.3,
      "electricity_usd_2026_kwh": 0.1247,
      "wacc": 0.0856,
      "construction_real_factor": 0.88762,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.83,
      "electricity": 3.38,
      "site_grid": 3.49,
      "operations": 7.71,
      "total": 56.41,
      "electricity_usd_2026_kwh": 0.1247,
      "wacc": 0.0856,
      "construction_real_factor": 0.88762,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.91,
      "electricity": 4.35,
      "site_grid": 3.16,
      "operations": 13.07,
      "total": 73.49,
      "electricity_usd_2026_kwh": 0.1247,
      "wacc": 0.0856,
      "construction_real_factor": 0.88762,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 92.54,
      "electricity": 7.97,
      "site_grid": 7.72,
      "operations": 18.35,
      "total": 126.58,
      "electricity_usd_2026_kwh": 0.1247,
      "wacc": 0.0856,
      "construction_real_factor": 0.88762,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 117.05,
      "electricity": 10.24,
      "site_grid": 6.99,
      "operations": 31.63,
      "total": 165.91,
      "electricity_usd_2026_kwh": 0.1247,
      "wacc": 0.0856,
      "construction_real_factor": 0.88762,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.72,
      "electricity": 1.28,
      "site_grid": 1.69,
      "operations": 3.33,
      "total": 26.02,
      "electricity_usd_2026_kwh": 0.1282,
      "wacc": 0.0912,
      "construction_real_factor": 0.8921,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.94,
      "electricity": 1.65,
      "site_grid": 1.53,
      "operations": 5.53,
      "total": 33.64,
      "electricity_usd_2026_kwh": 0.1282,
      "wacc": 0.0912,
      "construction_real_factor": 0.8921,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.25,
      "electricity": 3.48,
      "site_grid": 3.63,
      "operations": 7.71,
      "total": 57.07,
      "electricity_usd_2026_kwh": 0.1282,
      "wacc": 0.0912,
      "construction_real_factor": 0.8921,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.44,
      "electricity": 4.47,
      "site_grid": 3.27,
      "operations": 13.07,
      "total": 74.25,
      "electricity_usd_2026_kwh": 0.1282,
      "wacc": 0.0912,
      "construction_real_factor": 0.8921,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 93.47,
      "electricity": 8.19,
      "site_grid": 8.03,
      "operations": 18.35,
      "total": 128.04,
      "electricity_usd_2026_kwh": 0.1282,
      "wacc": 0.0912,
      "construction_real_factor": 0.8921,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 118.22,
      "electricity": 10.53,
      "site_grid": 7.23,
      "operations": 31.63,
      "total": 167.61,
      "electricity_usd_2026_kwh": 0.1282,
      "wacc": 0.0912,
      "construction_real_factor": 0.8921,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.25,
      "electricity": 1.38,
      "site_grid": 2.1,
      "operations": 3.33,
      "total": 27.05,
      "electricity_usd_2026_kwh": 0.1376,
      "wacc": 0.1062,
      "construction_real_factor": 1.0102,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.61,
      "electricity": 1.77,
      "site_grid": 1.86,
      "operations": 5.53,
      "total": 34.77,
      "electricity_usd_2026_kwh": 0.1376,
      "wacc": 0.1062,
      "construction_real_factor": 1.0102,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 43.39,
      "electricity": 3.73,
      "site_grid": 4.49,
      "operations": 7.71,
      "total": 59.33,
      "electricity_usd_2026_kwh": 0.1376,
      "wacc": 0.1062,
      "construction_real_factor": 1.0102,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 54.87,
      "electricity": 4.8,
      "site_grid": 3.98,
      "operations": 13.07,
      "total": 76.73,
      "electricity_usd_2026_kwh": 0.1376,
      "wacc": 0.1062,
      "construction_real_factor": 1.0102,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 96.0,
      "electricity": 8.79,
      "site_grid": 9.94,
      "operations": 18.35,
      "total": 133.08,
      "electricity_usd_2026_kwh": 0.1376,
      "wacc": 0.1062,
      "construction_real_factor": 1.0102,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 121.4,
      "electricity": 11.3,
      "site_grid": 8.81,
      "operations": 31.63,
      "total": 173.14,
      "electricity_usd_2026_kwh": 0.1376,
      "wacc": 0.1062,
      "construction_real_factor": 1.0102,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.61,
      "electricity": 1.28,
      "site_grid": 2.29,
      "operations": 3.33,
      "total": 27.51,
      "electricity_usd_2026_kwh": 0.1277,
      "wacc": 0.1163,
      "construction_real_factor": 1.04368,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 26.06,
      "electricity": 1.64,
      "site_grid": 2.02,
      "operations": 5.53,
      "total": 35.25,
      "electricity_usd_2026_kwh": 0.1277,
      "wacc": 0.1163,
      "construction_real_factor": 1.04368,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 44.16,
      "electricity": 3.46,
      "site_grid": 4.92,
      "operations": 7.71,
      "total": 60.25,
      "electricity_usd_2026_kwh": 0.1277,
      "wacc": 0.1163,
      "construction_real_factor": 1.04368,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 55.84,
      "electricity": 4.45,
      "site_grid": 4.32,
      "operations": 13.07,
      "total": 77.68,
      "electricity_usd_2026_kwh": 0.1277,
      "wacc": 0.1163,
      "construction_real_factor": 1.04368,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 97.7,
      "electricity": 8.16,
      "site_grid": 10.88,
      "operations": 18.35,
      "total": 135.09,
      "electricity_usd_2026_kwh": 0.1277,
      "wacc": 0.1163,
      "construction_real_factor": 1.04368,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 123.54,
      "electricity": 10.49,
      "site_grid": 9.55,
      "operations": 31.63,
      "total": 175.21,
      "electricity_usd_2026_kwh": 0.1277,
      "wacc": 0.1163,
      "construction_real_factor": 1.04368,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.7,
      "electricity": 1.25,
      "site_grid": 2.25,
      "operations": 3.33,
      "total": 27.53,
      "electricity_usd_2026_kwh": 0.1254,
      "wacc": 0.1188,
      "construction_real_factor": 1.01036,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 26.18,
      "electricity": 1.61,
      "site_grid": 1.97,
      "operations": 5.53,
      "total": 35.29,
      "electricity_usd_2026_kwh": 0.1254,
      "wacc": 0.1188,
      "construction_real_factor": 1.01036,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 44.35,
      "electricity": 3.4,
      "site_grid": 4.83,
      "operations": 7.71,
      "total": 60.29,
      "electricity_usd_2026_kwh": 0.1254,
      "wacc": 0.1188,
      "construction_real_factor": 1.01036,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 56.08,
      "electricity": 4.37,
      "site_grid": 4.23,
      "operations": 13.07,
      "total": 77.75,
      "electricity_usd_2026_kwh": 0.1254,
      "wacc": 0.1188,
      "construction_real_factor": 1.01036,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 98.12,
      "electricity": 8.01,
      "site_grid": 10.68,
      "operations": 18.35,
      "total": 135.16,
      "electricity_usd_2026_kwh": 0.1254,
      "wacc": 0.1188,
      "construction_real_factor": 1.01036,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 124.07,
      "electricity": 10.3,
      "site_grid": 9.36,
      "operations": 31.63,
      "total": 175.36,
      "electricity_usd_2026_kwh": 0.1254,
      "wacc": 0.1188,
      "construction_real_factor": 1.01036,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.73,
      "electricity": 1.3,
      "site_grid": 2.23,
      "operations": 3.33,
      "total": 27.59,
      "electricity_usd_2026_kwh": 0.1296,
      "wacc": 0.1196,
      "construction_real_factor": 0.99742,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 26.21,
      "electricity": 1.67,
      "site_grid": 1.96,
      "operations": 5.53,
      "total": 35.36,
      "electricity_usd_2026_kwh": 0.1296,
      "wacc": 0.1196,
      "construction_real_factor": 0.99742,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 44.42,
      "electricity": 3.51,
      "site_grid": 4.79,
      "operations": 7.71,
      "total": 60.43,
      "electricity_usd_2026_kwh": 0.1296,
      "wacc": 0.1196,
      "construction_real_factor": 0.99742,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 56.16,
      "electricity": 4.52,
      "site_grid": 4.19,
      "operations": 13.07,
      "total": 77.94,
      "electricity_usd_2026_kwh": 0.1296,
      "wacc": 0.1196,
      "construction_real_factor": 0.99742,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 98.27,
      "electricity": 8.28,
      "site_grid": 10.59,
      "operations": 18.35,
      "total": 135.49,
      "electricity_usd_2026_kwh": 0.1296,
      "wacc": 0.1196,
      "construction_real_factor": 0.99742,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 124.26,
      "electricity": 10.64,
      "site_grid": 9.27,
      "operations": 31.63,
      "total": 175.8,
      "electricity_usd_2026_kwh": 0.1296,
      "wacc": 0.1196,
      "construction_real_factor": 0.99742,
      "power_source": "EIA-anchored North America proxy",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.75,
      "electricity": 1.3,
      "site_grid": 2.24,
      "operations": 3.33,
      "total": 27.61,
      "electricity_usd_2026_kwh": 0.1296,
      "wacc": 0.12,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 26.23,
      "electricity": 1.67,
      "site_grid": 1.96,
      "operations": 5.53,
      "total": 35.39,
      "electricity_usd_2026_kwh": 0.1296,
      "wacc": 0.12,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 44.45,
      "electricity": 3.51,
      "site_grid": 4.81,
      "operations": 7.71,
      "total": 60.48,
      "electricity_usd_2026_kwh": 0.1296,
      "wacc": 0.12,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 56.2,
      "electricity": 4.52,
      "site_grid": 4.21,
      "operations": 13.07,
      "total": 78.0,
      "electricity_usd_2026_kwh": 0.1296,
      "wacc": 0.12,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 98.33,
      "electricity": 8.28,
      "site_grid": 10.64,
      "operations": 18.35,
      "total": 135.6,
      "electricity_usd_2026_kwh": 0.1296,
      "wacc": 0.12,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 124.34,
      "electricity": 10.64,
      "site_grid": 9.31,
      "operations": 31.63,
      "total": 175.92,
      "electricity_usd_2026_kwh": 0.1296,
      "wacc": 0.12,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.99,
      "electricity": 0.95,
      "site_grid": 1.28,
      "operations": 3.08,
      "total": 22.3,
      "electricity_usd_2026_kwh": 0.0991,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2010,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.36,
      "electricity": 1.22,
      "site_grid": 1.18,
      "operations": 5.33,
      "total": 29.09,
      "electricity_usd_2026_kwh": 0.0991,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2010,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.4,
      "electricity": 2.58,
      "site_grid": 2.75,
      "operations": 7.18,
      "total": 48.91,
      "electricity_usd_2026_kwh": 0.0991,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2010,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.77,
      "electricity": 3.31,
      "site_grid": 2.53,
      "operations": 12.63,
      "total": 64.24,
      "electricity_usd_2026_kwh": 0.0991,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2010,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.52,
      "electricity": 6.09,
      "site_grid": 6.08,
      "operations": 17.18,
      "total": 109.87,
      "electricity_usd_2026_kwh": 0.0991,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2010,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.26,
      "electricity": 7.79,
      "site_grid": 5.6,
      "operations": 30.64,
      "total": 145.28,
      "electricity_usd_2026_kwh": 0.0991,
      "wacc": 0.0638,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2011,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.85,
      "electricity": 0.99,
      "site_grid": 1.23,
      "operations": 3.08,
      "total": 22.15,
      "electricity_usd_2026_kwh": 0.1027,
      "wacc": 0.0595,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2011,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.19,
      "electricity": 1.26,
      "site_grid": 1.14,
      "operations": 5.33,
      "total": 28.92,
      "electricity_usd_2026_kwh": 0.1027,
      "wacc": 0.0595,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2011,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.1,
      "electricity": 2.68,
      "site_grid": 2.63,
      "operations": 7.18,
      "total": 48.6,
      "electricity_usd_2026_kwh": 0.1027,
      "wacc": 0.0595,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2011,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.41,
      "electricity": 3.43,
      "site_grid": 2.44,
      "operations": 12.63,
      "total": 63.91,
      "electricity_usd_2026_kwh": 0.1027,
      "wacc": 0.0595,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2011,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.88,
      "electricity": 6.31,
      "site_grid": 5.83,
      "operations": 17.18,
      "total": 109.2,
      "electricity_usd_2026_kwh": 0.1027,
      "wacc": 0.0595,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2011,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.45,
      "electricity": 8.08,
      "site_grid": 5.39,
      "operations": 30.64,
      "total": 144.56,
      "electricity_usd_2026_kwh": 0.1027,
      "wacc": 0.0595,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2012,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.55,
      "electricity": 1.0,
      "site_grid": 1.16,
      "operations": 3.08,
      "total": 21.78,
      "electricity_usd_2026_kwh": 0.1037,
      "wacc": 0.0497,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2012,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.81,
      "electricity": 1.28,
      "site_grid": 1.08,
      "operations": 5.33,
      "total": 28.5,
      "electricity_usd_2026_kwh": 0.1037,
      "wacc": 0.0497,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2012,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.45,
      "electricity": 2.7,
      "site_grid": 2.48,
      "operations": 7.18,
      "total": 47.81,
      "electricity_usd_2026_kwh": 0.1037,
      "wacc": 0.0497,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2012,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.59,
      "electricity": 3.46,
      "site_grid": 2.32,
      "operations": 12.63,
      "total": 63.0,
      "electricity_usd_2026_kwh": 0.1037,
      "wacc": 0.0497,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2012,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.42,
      "electricity": 6.37,
      "site_grid": 5.48,
      "operations": 17.18,
      "total": 107.45,
      "electricity_usd_2026_kwh": 0.1037,
      "wacc": 0.0497,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2012,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.64,
      "electricity": 8.15,
      "site_grid": 5.13,
      "operations": 30.64,
      "total": 142.56,
      "electricity_usd_2026_kwh": 0.1037,
      "wacc": 0.0497,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2013,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.72,
      "electricity": 0.99,
      "site_grid": 1.21,
      "operations": 3.08,
      "total": 22.0,
      "electricity_usd_2026_kwh": 0.1027,
      "wacc": 0.0552,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2013,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.02,
      "electricity": 1.26,
      "site_grid": 1.13,
      "operations": 5.33,
      "total": 28.74,
      "electricity_usd_2026_kwh": 0.1027,
      "wacc": 0.0552,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2013,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.81,
      "electricity": 2.68,
      "site_grid": 2.59,
      "operations": 7.18,
      "total": 48.27,
      "electricity_usd_2026_kwh": 0.1027,
      "wacc": 0.0552,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2013,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.04,
      "electricity": 3.43,
      "site_grid": 2.41,
      "operations": 12.63,
      "total": 63.52,
      "electricity_usd_2026_kwh": 0.1027,
      "wacc": 0.0552,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2013,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.23,
      "electricity": 6.31,
      "site_grid": 5.74,
      "operations": 17.18,
      "total": 108.47,
      "electricity_usd_2026_kwh": 0.1027,
      "wacc": 0.0552,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2013,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.65,
      "electricity": 8.08,
      "site_grid": 5.34,
      "operations": 30.64,
      "total": 143.7,
      "electricity_usd_2026_kwh": 0.1027,
      "wacc": 0.0552,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2014,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.78,
      "electricity": 0.95,
      "site_grid": 1.25,
      "operations": 3.08,
      "total": 22.06,
      "electricity_usd_2026_kwh": 0.0991,
      "wacc": 0.0571,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2014,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.1,
      "electricity": 1.22,
      "site_grid": 1.16,
      "operations": 5.33,
      "total": 28.8,
      "electricity_usd_2026_kwh": 0.0991,
      "wacc": 0.0571,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2014,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.94,
      "electricity": 2.58,
      "site_grid": 2.67,
      "operations": 7.18,
      "total": 48.38,
      "electricity_usd_2026_kwh": 0.0991,
      "wacc": 0.0571,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2014,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.2,
      "electricity": 3.31,
      "site_grid": 2.48,
      "operations": 12.63,
      "total": 63.62,
      "electricity_usd_2026_kwh": 0.0991,
      "wacc": 0.0571,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2014,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.52,
      "electricity": 6.09,
      "site_grid": 5.9,
      "operations": 17.18,
      "total": 108.69,
      "electricity_usd_2026_kwh": 0.0991,
      "wacc": 0.0571,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2014,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.0,
      "electricity": 7.79,
      "site_grid": 5.48,
      "operations": 30.64,
      "total": 143.91,
      "electricity_usd_2026_kwh": 0.0991,
      "wacc": 0.0571,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2015,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.65,
      "electricity": 0.9,
      "site_grid": 1.23,
      "operations": 3.08,
      "total": 21.86,
      "electricity_usd_2026_kwh": 0.0936,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2015,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.94,
      "electricity": 1.15,
      "site_grid": 1.15,
      "operations": 5.33,
      "total": 28.57,
      "electricity_usd_2026_kwh": 0.0936,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2015,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.67,
      "electricity": 2.44,
      "site_grid": 2.64,
      "operations": 7.18,
      "total": 47.94,
      "electricity_usd_2026_kwh": 0.0936,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2015,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.87,
      "electricity": 3.12,
      "site_grid": 2.47,
      "operations": 12.63,
      "total": 63.09,
      "electricity_usd_2026_kwh": 0.0936,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2015,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.92,
      "electricity": 5.75,
      "site_grid": 5.85,
      "operations": 17.18,
      "total": 107.7,
      "electricity_usd_2026_kwh": 0.0936,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2015,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.26,
      "electricity": 7.35,
      "site_grid": 5.46,
      "operations": 30.64,
      "total": 142.71,
      "electricity_usd_2026_kwh": 0.0936,
      "wacc": 0.0531,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2016,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.56,
      "electricity": 0.87,
      "site_grid": 1.2,
      "operations": 3.08,
      "total": 21.7,
      "electricity_usd_2026_kwh": 0.0899,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2016,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.82,
      "electricity": 1.11,
      "site_grid": 1.12,
      "operations": 5.33,
      "total": 28.38,
      "electricity_usd_2026_kwh": 0.0899,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2016,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.47,
      "electricity": 2.35,
      "site_grid": 2.57,
      "operations": 7.18,
      "total": 47.57,
      "electricity_usd_2026_kwh": 0.0899,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2016,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.61,
      "electricity": 3.0,
      "site_grid": 2.41,
      "operations": 12.63,
      "total": 62.66,
      "electricity_usd_2026_kwh": 0.0899,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2016,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.47,
      "electricity": 5.52,
      "site_grid": 5.69,
      "operations": 17.18,
      "total": 106.87,
      "electricity_usd_2026_kwh": 0.0899,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2016,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 98.7,
      "electricity": 7.07,
      "site_grid": 5.33,
      "operations": 30.64,
      "total": 141.74,
      "electricity_usd_2026_kwh": 0.0899,
      "wacc": 0.0501,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2017,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.71,
      "electricity": 0.88,
      "site_grid": 1.25,
      "operations": 3.08,
      "total": 21.92,
      "electricity_usd_2026_kwh": 0.0917,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2017,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.02,
      "electricity": 1.13,
      "site_grid": 1.16,
      "operations": 5.33,
      "total": 28.63,
      "electricity_usd_2026_kwh": 0.0917,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2017,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.8,
      "electricity": 2.39,
      "site_grid": 2.67,
      "operations": 7.18,
      "total": 48.05,
      "electricity_usd_2026_kwh": 0.0917,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2017,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.03,
      "electricity": 3.06,
      "site_grid": 2.49,
      "operations": 12.63,
      "total": 63.21,
      "electricity_usd_2026_kwh": 0.0917,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2017,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 79.2,
      "electricity": 5.64,
      "site_grid": 5.91,
      "operations": 17.18,
      "total": 107.93,
      "electricity_usd_2026_kwh": 0.0917,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2017,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.61,
      "electricity": 7.21,
      "site_grid": 5.5,
      "operations": 30.64,
      "total": 142.96,
      "electricity_usd_2026_kwh": 0.0917,
      "wacc": 0.055,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2018,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.89,
      "electricity": 0.93,
      "site_grid": 1.33,
      "operations": 3.08,
      "total": 22.23,
      "electricity_usd_2026_kwh": 0.0963,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2018,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.24,
      "electricity": 1.19,
      "site_grid": 1.23,
      "operations": 5.33,
      "total": 28.98,
      "electricity_usd_2026_kwh": 0.0963,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2018,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.19,
      "electricity": 2.51,
      "site_grid": 2.84,
      "operations": 7.18,
      "total": 48.73,
      "electricity_usd_2026_kwh": 0.0963,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2018,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.51,
      "electricity": 3.21,
      "site_grid": 2.62,
      "operations": 12.63,
      "total": 63.99,
      "electricity_usd_2026_kwh": 0.0963,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2018,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.07,
      "electricity": 5.92,
      "site_grid": 6.29,
      "operations": 17.18,
      "total": 109.45,
      "electricity_usd_2026_kwh": 0.0963,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2018,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.69,
      "electricity": 7.57,
      "site_grid": 5.81,
      "operations": 30.64,
      "total": 144.71,
      "electricity_usd_2026_kwh": 0.0963,
      "wacc": 0.0608,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2019,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.65,
      "electricity": 0.89,
      "site_grid": 1.31,
      "operations": 3.08,
      "total": 21.93,
      "electricity_usd_2026_kwh": 0.0927,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2019,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.94,
      "electricity": 1.14,
      "site_grid": 1.22,
      "operations": 5.33,
      "total": 28.63,
      "electricity_usd_2026_kwh": 0.0927,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2019,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.67,
      "electricity": 2.42,
      "site_grid": 2.8,
      "operations": 7.18,
      "total": 48.08,
      "electricity_usd_2026_kwh": 0.0927,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2019,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.87,
      "electricity": 3.09,
      "site_grid": 2.62,
      "operations": 12.63,
      "total": 63.21,
      "electricity_usd_2026_kwh": 0.0927,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2019,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 78.92,
      "electricity": 5.69,
      "site_grid": 6.21,
      "operations": 17.18,
      "total": 108.0,
      "electricity_usd_2026_kwh": 0.0927,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2019,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 99.26,
      "electricity": 7.28,
      "site_grid": 5.79,
      "operations": 30.64,
      "total": 142.97,
      "electricity_usd_2026_kwh": 0.0927,
      "wacc": 0.0531,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2020,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.26,
      "electricity": 0.85,
      "site_grid": 1.22,
      "operations": 3.08,
      "total": 21.41,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2020,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.45,
      "electricity": 1.08,
      "site_grid": 1.16,
      "operations": 5.33,
      "total": 28.02,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2020,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 34.84,
      "electricity": 2.3,
      "site_grid": 2.61,
      "operations": 7.18,
      "total": 46.93,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2020,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 43.82,
      "electricity": 2.94,
      "site_grid": 2.48,
      "operations": 12.63,
      "total": 61.87,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2020,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.08,
      "electricity": 5.41,
      "site_grid": 5.78,
      "operations": 17.18,
      "total": 105.45,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2020,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 96.95,
      "electricity": 6.92,
      "site_grid": 5.48,
      "operations": 30.64,
      "total": 140.0,
      "electricity_usd_2026_kwh": 0.0881,
      "wacc": 0.0406,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2021,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.43,
      "electricity": 0.91,
      "site_grid": 1.27,
      "operations": 3.08,
      "total": 21.7,
      "electricity_usd_2026_kwh": 0.0945,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2021,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 20.67,
      "electricity": 1.16,
      "site_grid": 1.2,
      "operations": 5.33,
      "total": 28.36,
      "electricity_usd_2026_kwh": 0.0945,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2021,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 35.21,
      "electricity": 2.47,
      "site_grid": 2.73,
      "operations": 7.18,
      "total": 47.59,
      "electricity_usd_2026_kwh": 0.0945,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2021,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 44.29,
      "electricity": 3.15,
      "site_grid": 2.57,
      "operations": 12.63,
      "total": 62.65,
      "electricity_usd_2026_kwh": 0.0945,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2021,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 77.9,
      "electricity": 5.81,
      "site_grid": 6.04,
      "operations": 17.18,
      "total": 106.93,
      "electricity_usd_2026_kwh": 0.0945,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2021,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 97.98,
      "electricity": 7.43,
      "site_grid": 5.69,
      "operations": 30.64,
      "total": 141.74,
      "electricity_usd_2026_kwh": 0.0945,
      "wacc": 0.0462,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2022,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 16.9,
      "electricity": 1.02,
      "site_grid": 1.6,
      "operations": 3.08,
      "total": 22.6,
      "electricity_usd_2026_kwh": 0.1055,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2022,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.26,
      "electricity": 1.3,
      "site_grid": 1.48,
      "operations": 5.33,
      "total": 29.37,
      "electricity_usd_2026_kwh": 0.1055,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2022,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.22,
      "electricity": 2.75,
      "site_grid": 3.43,
      "operations": 7.18,
      "total": 49.59,
      "electricity_usd_2026_kwh": 0.1055,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2022,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.55,
      "electricity": 3.52,
      "site_grid": 3.17,
      "operations": 12.63,
      "total": 64.87,
      "electricity_usd_2026_kwh": 0.1055,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2022,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.13,
      "electricity": 6.48,
      "site_grid": 7.59,
      "operations": 17.18,
      "total": 111.38,
      "electricity_usd_2026_kwh": 0.1055,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2022,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.77,
      "electricity": 8.29,
      "site_grid": 7.01,
      "operations": 30.64,
      "total": 146.71,
      "electricity_usd_2026_kwh": 0.1055,
      "wacc": 0.0612,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2023,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.22,
      "electricity": 0.96,
      "site_grid": 1.77,
      "operations": 3.08,
      "total": 23.03,
      "electricity_usd_2026_kwh": 0.1,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2023,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.66,
      "electricity": 1.23,
      "site_grid": 1.61,
      "operations": 5.33,
      "total": 29.83,
      "electricity_usd_2026_kwh": 0.1,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2023,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.9,
      "electricity": 2.61,
      "site_grid": 3.79,
      "operations": 7.18,
      "total": 50.48,
      "electricity_usd_2026_kwh": 0.1,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2023,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.4,
      "electricity": 3.34,
      "site_grid": 3.46,
      "operations": 12.63,
      "total": 65.82,
      "electricity_usd_2026_kwh": 0.1,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2023,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.63,
      "electricity": 6.14,
      "site_grid": 8.38,
      "operations": 17.18,
      "total": 113.34,
      "electricity_usd_2026_kwh": 0.1,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2023,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.65,
      "electricity": 7.86,
      "site_grid": 7.64,
      "operations": 30.64,
      "total": 148.79,
      "electricity_usd_2026_kwh": 0.1,
      "wacc": 0.0713,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2024,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.3,
      "electricity": 0.92,
      "site_grid": 1.74,
      "operations": 3.08,
      "total": 23.04,
      "electricity_usd_2026_kwh": 0.0954,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2024,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.75,
      "electricity": 1.17,
      "site_grid": 1.58,
      "operations": 5.33,
      "total": 29.84,
      "electricity_usd_2026_kwh": 0.0954,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2024,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.07,
      "electricity": 2.49,
      "site_grid": 3.73,
      "operations": 7.18,
      "total": 50.47,
      "electricity_usd_2026_kwh": 0.0954,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2024,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.61,
      "electricity": 3.18,
      "site_grid": 3.39,
      "operations": 12.63,
      "total": 65.82,
      "electricity_usd_2026_kwh": 0.0954,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2024,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.01,
      "electricity": 5.86,
      "site_grid": 8.25,
      "operations": 17.18,
      "total": 113.3,
      "electricity_usd_2026_kwh": 0.0954,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2024,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.12,
      "electricity": 7.5,
      "site_grid": 7.5,
      "operations": 30.64,
      "total": 148.75,
      "electricity_usd_2026_kwh": 0.0954,
      "wacc": 0.0738,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2025,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.33,
      "electricity": 0.88,
      "site_grid": 1.73,
      "operations": 3.08,
      "total": 23.02,
      "electricity_usd_2026_kwh": 0.0917,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2025,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.79,
      "electricity": 1.13,
      "site_grid": 1.57,
      "operations": 5.33,
      "total": 29.82,
      "electricity_usd_2026_kwh": 0.0917,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2025,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.13,
      "electricity": 2.39,
      "site_grid": 3.7,
      "operations": 7.18,
      "total": 50.4,
      "electricity_usd_2026_kwh": 0.0917,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2025,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.68,
      "electricity": 3.06,
      "site_grid": 3.36,
      "operations": 12.63,
      "total": 65.74,
      "electricity_usd_2026_kwh": 0.0917,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2025,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.14,
      "electricity": 5.64,
      "site_grid": 8.19,
      "operations": 17.18,
      "total": 113.14,
      "electricity_usd_2026_kwh": 0.0917,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2025,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.28,
      "electricity": 7.21,
      "site_grid": 7.44,
      "operations": 30.64,
      "total": 148.56,
      "electricity_usd_2026_kwh": 0.0917,
      "wacc": 0.0746,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "D"
    },
    {
      "year": 2026,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.34,
      "electricity": 0.88,
      "site_grid": 1.74,
      "operations": 3.08,
      "total": 23.04,
      "electricity_usd_2026_kwh": 0.0917,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "D"
    },
    {
      "year": 2026,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.8,
      "electricity": 1.13,
      "site_grid": 1.58,
      "operations": 5.33,
      "total": 29.84,
      "electricity_usd_2026_kwh": 0.0917,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "D"
    },
    {
      "year": 2026,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.15,
      "electricity": 2.39,
      "site_grid": 3.72,
      "operations": 7.18,
      "total": 50.45,
      "electricity_usd_2026_kwh": 0.0917,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "D"
    },
    {
      "year": 2026,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.71,
      "electricity": 3.06,
      "site_grid": 3.38,
      "operations": 12.63,
      "total": 65.79,
      "electricity_usd_2026_kwh": 0.0917,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "D"
    },
    {
      "year": 2026,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.19,
      "electricity": 5.64,
      "site_grid": 8.23,
      "operations": 17.18,
      "total": 113.24,
      "electricity_usd_2026_kwh": 0.0917,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "D"
    },
    {
      "year": 2026,
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.35,
      "electricity": 7.21,
      "site_grid": 7.47,
      "operations": 30.64,
      "total": 148.67,
      "electricity_usd_2026_kwh": 0.0917,
      "wacc": 0.075,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "D"
    },
    {
      "year": 2010,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 21.48,
      "electricity": 1.13,
      "site_grid": 1.55,
      "operations": 3.44,
      "total": 27.6,
      "electricity_usd_2026_kwh": 0.109,
      "wacc": 0.1038,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 27.21,
      "electricity": 1.45,
      "site_grid": 1.32,
      "operations": 5.36,
      "total": 35.34,
      "electricity_usd_2026_kwh": 0.109,
      "wacc": 0.1038,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 46.02,
      "electricity": 3.06,
      "site_grid": 3.33,
      "operations": 7.96,
      "total": 60.37,
      "electricity_usd_2026_kwh": 0.109,
      "wacc": 0.1038,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 58.3,
      "electricity": 3.94,
      "site_grid": 2.82,
      "operations": 12.72,
      "total": 77.78,
      "electricity_usd_2026_kwh": 0.109,
      "wacc": 0.1038,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 101.8,
      "electricity": 7.21,
      "site_grid": 7.36,
      "operations": 18.92,
      "total": 135.28,
      "electricity_usd_2026_kwh": 0.109,
      "wacc": 0.1038,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 128.98,
      "electricity": 9.28,
      "site_grid": 6.23,
      "operations": 30.87,
      "total": 175.36,
      "electricity_usd_2026_kwh": 0.109,
      "wacc": 0.1038,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 21.31,
      "electricity": 1.17,
      "site_grid": 1.49,
      "operations": 3.44,
      "total": 27.42,
      "electricity_usd_2026_kwh": 0.113,
      "wacc": 0.0995,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 27.01,
      "electricity": 1.51,
      "site_grid": 1.27,
      "operations": 5.36,
      "total": 35.15,
      "electricity_usd_2026_kwh": 0.113,
      "wacc": 0.0995,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 45.67,
      "electricity": 3.17,
      "site_grid": 3.2,
      "operations": 7.96,
      "total": 60.0,
      "electricity_usd_2026_kwh": 0.113,
      "wacc": 0.0995,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 57.86,
      "electricity": 4.09,
      "site_grid": 2.72,
      "operations": 12.72,
      "total": 77.39,
      "electricity_usd_2026_kwh": 0.113,
      "wacc": 0.0995,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 101.03,
      "electricity": 7.48,
      "site_grid": 7.08,
      "operations": 18.92,
      "total": 134.49,
      "electricity_usd_2026_kwh": 0.113,
      "wacc": 0.0995,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 128.01,
      "electricity": 9.62,
      "site_grid": 6.02,
      "operations": 30.87,
      "total": 174.52,
      "electricity_usd_2026_kwh": 0.113,
      "wacc": 0.0995,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.95,
      "electricity": 1.18,
      "site_grid": 1.42,
      "operations": 3.44,
      "total": 26.98,
      "electricity_usd_2026_kwh": 0.114,
      "wacc": 0.0897,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 26.54,
      "electricity": 1.52,
      "site_grid": 1.22,
      "operations": 5.36,
      "total": 34.64,
      "electricity_usd_2026_kwh": 0.114,
      "wacc": 0.0897,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 44.88,
      "electricity": 3.2,
      "site_grid": 3.03,
      "operations": 7.96,
      "total": 59.07,
      "electricity_usd_2026_kwh": 0.114,
      "wacc": 0.0897,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 56.86,
      "electricity": 4.12,
      "site_grid": 2.61,
      "operations": 12.72,
      "total": 76.31,
      "electricity_usd_2026_kwh": 0.114,
      "wacc": 0.0897,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 99.28,
      "electricity": 7.54,
      "site_grid": 6.71,
      "operations": 18.92,
      "total": 132.44,
      "electricity_usd_2026_kwh": 0.114,
      "wacc": 0.0897,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 125.81,
      "electricity": 9.71,
      "site_grid": 5.77,
      "operations": 30.87,
      "total": 172.14,
      "electricity_usd_2026_kwh": 0.114,
      "wacc": 0.0897,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 21.15,
      "electricity": 1.17,
      "site_grid": 1.47,
      "operations": 3.44,
      "total": 27.24,
      "electricity_usd_2026_kwh": 0.113,
      "wacc": 0.0952,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 26.8,
      "electricity": 1.51,
      "site_grid": 1.26,
      "operations": 5.36,
      "total": 34.93,
      "electricity_usd_2026_kwh": 0.113,
      "wacc": 0.0952,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 45.32,
      "electricity": 3.17,
      "site_grid": 3.16,
      "operations": 7.96,
      "total": 59.61,
      "electricity_usd_2026_kwh": 0.113,
      "wacc": 0.0952,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 57.42,
      "electricity": 4.09,
      "site_grid": 2.7,
      "operations": 12.72,
      "total": 76.93,
      "electricity_usd_2026_kwh": 0.113,
      "wacc": 0.0952,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 100.26,
      "electricity": 7.48,
      "site_grid": 6.99,
      "operations": 18.92,
      "total": 133.64,
      "electricity_usd_2026_kwh": 0.113,
      "wacc": 0.0952,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 127.03,
      "electricity": 9.62,
      "site_grid": 5.98,
      "operations": 30.87,
      "total": 173.5,
      "electricity_usd_2026_kwh": 0.113,
      "wacc": 0.0952,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 21.22,
      "electricity": 1.13,
      "site_grid": 1.52,
      "operations": 3.44,
      "total": 27.31,
      "electricity_usd_2026_kwh": 0.109,
      "wacc": 0.0971,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 26.89,
      "electricity": 1.45,
      "site_grid": 1.29,
      "operations": 5.36,
      "total": 35.0,
      "electricity_usd_2026_kwh": 0.109,
      "wacc": 0.0971,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 45.47,
      "electricity": 3.06,
      "site_grid": 3.25,
      "operations": 7.96,
      "total": 59.74,
      "electricity_usd_2026_kwh": 0.109,
      "wacc": 0.0971,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 57.61,
      "electricity": 3.94,
      "site_grid": 2.77,
      "operations": 12.72,
      "total": 77.04,
      "electricity_usd_2026_kwh": 0.109,
      "wacc": 0.0971,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 100.6,
      "electricity": 7.21,
      "site_grid": 7.18,
      "operations": 18.92,
      "total": 133.9,
      "electricity_usd_2026_kwh": 0.109,
      "wacc": 0.0971,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 127.46,
      "electricity": 9.28,
      "site_grid": 6.13,
      "operations": 30.87,
      "total": 173.73,
      "electricity_usd_2026_kwh": 0.109,
      "wacc": 0.0971,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 21.07,
      "electricity": 1.07,
      "site_grid": 1.51,
      "operations": 3.44,
      "total": 27.09,
      "electricity_usd_2026_kwh": 0.1029,
      "wacc": 0.0931,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 26.7,
      "electricity": 1.37,
      "site_grid": 1.29,
      "operations": 5.36,
      "total": 34.73,
      "electricity_usd_2026_kwh": 0.1029,
      "wacc": 0.0931,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 45.15,
      "electricity": 2.89,
      "site_grid": 3.23,
      "operations": 7.96,
      "total": 59.23,
      "electricity_usd_2026_kwh": 0.1029,
      "wacc": 0.0931,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 57.2,
      "electricity": 3.72,
      "site_grid": 2.76,
      "operations": 12.72,
      "total": 76.41,
      "electricity_usd_2026_kwh": 0.1029,
      "wacc": 0.0931,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 99.88,
      "electricity": 6.81,
      "site_grid": 7.14,
      "operations": 18.92,
      "total": 132.74,
      "electricity_usd_2026_kwh": 0.1029,
      "wacc": 0.0931,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 126.56,
      "electricity": 8.76,
      "site_grid": 6.11,
      "operations": 30.87,
      "total": 172.3,
      "electricity_usd_2026_kwh": 0.1029,
      "wacc": 0.0931,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.96,
      "electricity": 1.02,
      "site_grid": 1.47,
      "operations": 3.44,
      "total": 26.9,
      "electricity_usd_2026_kwh": 0.0989,
      "wacc": 0.0901,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 26.56,
      "electricity": 1.32,
      "site_grid": 1.26,
      "operations": 5.36,
      "total": 34.5,
      "electricity_usd_2026_kwh": 0.0989,
      "wacc": 0.0901,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 44.9,
      "electricity": 2.78,
      "site_grid": 3.15,
      "operations": 7.96,
      "total": 58.79,
      "electricity_usd_2026_kwh": 0.0989,
      "wacc": 0.0901,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 56.9,
      "electricity": 3.57,
      "site_grid": 2.71,
      "operations": 12.72,
      "total": 75.9,
      "electricity_usd_2026_kwh": 0.0989,
      "wacc": 0.0901,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 99.34,
      "electricity": 6.54,
      "site_grid": 6.97,
      "operations": 18.92,
      "total": 131.76,
      "electricity_usd_2026_kwh": 0.0989,
      "wacc": 0.0901,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 125.88,
      "electricity": 8.42,
      "site_grid": 5.98,
      "operations": 30.87,
      "total": 171.15,
      "electricity_usd_2026_kwh": 0.0989,
      "wacc": 0.0901,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 21.14,
      "electricity": 1.05,
      "site_grid": 1.52,
      "operations": 3.44,
      "total": 27.15,
      "electricity_usd_2026_kwh": 0.1009,
      "wacc": 0.095,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 26.79,
      "electricity": 1.35,
      "site_grid": 1.3,
      "operations": 5.36,
      "total": 34.8,
      "electricity_usd_2026_kwh": 0.1009,
      "wacc": 0.095,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 45.3,
      "electricity": 2.83,
      "site_grid": 3.26,
      "operations": 7.96,
      "total": 59.35,
      "electricity_usd_2026_kwh": 0.1009,
      "wacc": 0.095,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 57.4,
      "electricity": 3.65,
      "site_grid": 2.78,
      "operations": 12.72,
      "total": 76.55,
      "electricity_usd_2026_kwh": 0.1009,
      "wacc": 0.095,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 100.22,
      "electricity": 6.67,
      "site_grid": 7.2,
      "operations": 18.92,
      "total": 133.01,
      "electricity_usd_2026_kwh": 0.1009,
      "wacc": 0.095,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 126.99,
      "electricity": 8.59,
      "site_grid": 6.16,
      "operations": 30.87,
      "total": 172.6,
      "electricity_usd_2026_kwh": 0.1009,
      "wacc": 0.095,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 21.36,
      "electricity": 1.1,
      "site_grid": 1.61,
      "operations": 3.44,
      "total": 27.51,
      "electricity_usd_2026_kwh": 0.106,
      "wacc": 0.1008,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 27.07,
      "electricity": 1.41,
      "site_grid": 1.37,
      "operations": 5.36,
      "total": 35.21,
      "electricity_usd_2026_kwh": 0.106,
      "wacc": 0.1008,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 45.77,
      "electricity": 2.98,
      "site_grid": 3.45,
      "operations": 7.96,
      "total": 60.15,
      "electricity_usd_2026_kwh": 0.106,
      "wacc": 0.1008,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 57.99,
      "electricity": 3.83,
      "site_grid": 2.93,
      "operations": 12.72,
      "total": 77.47,
      "electricity_usd_2026_kwh": 0.106,
      "wacc": 0.1008,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 101.26,
      "electricity": 7.01,
      "site_grid": 7.62,
      "operations": 18.92,
      "total": 134.8,
      "electricity_usd_2026_kwh": 0.106,
      "wacc": 0.1008,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 128.3,
      "electricity": 9.02,
      "site_grid": 6.48,
      "operations": 30.87,
      "total": 174.66,
      "electricity_usd_2026_kwh": 0.106,
      "wacc": 0.1008,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 21.07,
      "electricity": 1.06,
      "site_grid": 1.6,
      "operations": 3.44,
      "total": 27.17,
      "electricity_usd_2026_kwh": 0.1019,
      "wacc": 0.0931,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 26.7,
      "electricity": 1.36,
      "site_grid": 1.37,
      "operations": 5.36,
      "total": 34.79,
      "electricity_usd_2026_kwh": 0.1019,
      "wacc": 0.0931,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 45.15,
      "electricity": 2.86,
      "site_grid": 3.42,
      "operations": 7.96,
      "total": 59.4,
      "electricity_usd_2026_kwh": 0.1019,
      "wacc": 0.0931,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 57.21,
      "electricity": 3.68,
      "site_grid": 2.93,
      "operations": 12.72,
      "total": 76.55,
      "electricity_usd_2026_kwh": 0.1019,
      "wacc": 0.0931,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 99.88,
      "electricity": 6.74,
      "site_grid": 7.58,
      "operations": 18.92,
      "total": 133.11,
      "electricity_usd_2026_kwh": 0.1019,
      "wacc": 0.0931,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 126.56,
      "electricity": 8.68,
      "site_grid": 6.49,
      "operations": 30.87,
      "total": 172.6,
      "electricity_usd_2026_kwh": 0.1019,
      "wacc": 0.0931,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.6,
      "electricity": 1.0,
      "site_grid": 1.5,
      "operations": 3.44,
      "total": 26.55,
      "electricity_usd_2026_kwh": 0.0969,
      "wacc": 0.0806,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 26.11,
      "electricity": 1.29,
      "site_grid": 1.31,
      "operations": 5.36,
      "total": 34.07,
      "electricity_usd_2026_kwh": 0.0969,
      "wacc": 0.0806,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 44.14,
      "electricity": 2.72,
      "site_grid": 3.22,
      "operations": 7.96,
      "total": 58.05,
      "electricity_usd_2026_kwh": 0.0969,
      "wacc": 0.0806,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 55.94,
      "electricity": 3.5,
      "site_grid": 2.8,
      "operations": 12.72,
      "total": 74.96,
      "electricity_usd_2026_kwh": 0.0969,
      "wacc": 0.0806,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 97.66,
      "electricity": 6.41,
      "site_grid": 7.13,
      "operations": 18.92,
      "total": 130.11,
      "electricity_usd_2026_kwh": 0.0969,
      "wacc": 0.0806,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 123.76,
      "electricity": 8.25,
      "site_grid": 6.19,
      "operations": 30.87,
      "total": 169.07,
      "electricity_usd_2026_kwh": 0.0969,
      "wacc": 0.0806,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.81,
      "electricity": 1.08,
      "site_grid": 1.57,
      "operations": 3.44,
      "total": 26.9,
      "electricity_usd_2026_kwh": 0.1039,
      "wacc": 0.0862,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 26.37,
      "electricity": 1.39,
      "site_grid": 1.35,
      "operations": 5.36,
      "total": 34.47,
      "electricity_usd_2026_kwh": 0.1039,
      "wacc": 0.0862,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 44.59,
      "electricity": 2.92,
      "site_grid": 3.36,
      "operations": 7.96,
      "total": 58.83,
      "electricity_usd_2026_kwh": 0.1039,
      "wacc": 0.0862,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 56.5,
      "electricity": 3.76,
      "site_grid": 2.9,
      "operations": 12.72,
      "total": 75.88,
      "electricity_usd_2026_kwh": 0.1039,
      "wacc": 0.0862,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 98.65,
      "electricity": 6.87,
      "site_grid": 7.42,
      "operations": 18.92,
      "total": 131.86,
      "electricity_usd_2026_kwh": 0.1039,
      "wacc": 0.0862,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 125.01,
      "electricity": 8.85,
      "site_grid": 6.4,
      "operations": 30.87,
      "total": 171.13,
      "electricity_usd_2026_kwh": 0.1039,
      "wacc": 0.0862,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 21.38,
      "electricity": 1.2,
      "site_grid": 1.94,
      "operations": 3.44,
      "total": 27.96,
      "electricity_usd_2026_kwh": 0.116,
      "wacc": 0.1012,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 27.09,
      "electricity": 1.55,
      "site_grid": 1.65,
      "operations": 5.36,
      "total": 35.65,
      "electricity_usd_2026_kwh": 0.116,
      "wacc": 0.1012,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 45.8,
      "electricity": 3.26,
      "site_grid": 4.16,
      "operations": 7.96,
      "total": 61.18,
      "electricity_usd_2026_kwh": 0.116,
      "wacc": 0.1012,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 58.03,
      "electricity": 4.19,
      "site_grid": 3.53,
      "operations": 12.72,
      "total": 78.48,
      "electricity_usd_2026_kwh": 0.116,
      "wacc": 0.1012,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 101.33,
      "electricity": 7.68,
      "site_grid": 9.2,
      "operations": 18.92,
      "total": 137.12,
      "electricity_usd_2026_kwh": 0.116,
      "wacc": 0.1012,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 128.39,
      "electricity": 9.88,
      "site_grid": 7.82,
      "operations": 30.87,
      "total": 176.95,
      "electricity_usd_2026_kwh": 0.116,
      "wacc": 0.1012,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 21.76,
      "electricity": 1.14,
      "site_grid": 2.13,
      "operations": 3.44,
      "total": 28.47,
      "electricity_usd_2026_kwh": 0.11,
      "wacc": 0.1113,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 27.57,
      "electricity": 1.47,
      "site_grid": 1.79,
      "operations": 5.36,
      "total": 36.19,
      "electricity_usd_2026_kwh": 0.11,
      "wacc": 0.1113,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 46.62,
      "electricity": 3.09,
      "site_grid": 4.55,
      "operations": 7.96,
      "total": 62.23,
      "electricity_usd_2026_kwh": 0.11,
      "wacc": 0.1113,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 59.06,
      "electricity": 3.98,
      "site_grid": 3.83,
      "operations": 12.72,
      "total": 79.59,
      "electricity_usd_2026_kwh": 0.11,
      "wacc": 0.1113,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 103.14,
      "electricity": 7.27,
      "site_grid": 10.08,
      "operations": 18.92,
      "total": 139.41,
      "electricity_usd_2026_kwh": 0.11,
      "wacc": 0.1113,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 130.67,
      "electricity": 9.36,
      "site_grid": 8.48,
      "operations": 30.87,
      "total": 179.38,
      "electricity_usd_2026_kwh": 0.11,
      "wacc": 0.1113,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 21.85,
      "electricity": 1.09,
      "site_grid": 2.09,
      "operations": 3.44,
      "total": 28.47,
      "electricity_usd_2026_kwh": 0.1049,
      "wacc": 0.1138,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 27.69,
      "electricity": 1.4,
      "site_grid": 1.75,
      "operations": 5.36,
      "total": 36.2,
      "electricity_usd_2026_kwh": 0.1049,
      "wacc": 0.1138,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 46.82,
      "electricity": 2.95,
      "site_grid": 4.47,
      "operations": 7.96,
      "total": 62.21,
      "electricity_usd_2026_kwh": 0.1049,
      "wacc": 0.1138,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 59.32,
      "electricity": 3.79,
      "site_grid": 3.75,
      "operations": 12.72,
      "total": 79.59,
      "electricity_usd_2026_kwh": 0.1049,
      "wacc": 0.1138,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 103.59,
      "electricity": 6.94,
      "site_grid": 9.89,
      "operations": 18.92,
      "total": 139.34,
      "electricity_usd_2026_kwh": 0.1049,
      "wacc": 0.1138,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 131.23,
      "electricity": 8.93,
      "site_grid": 8.3,
      "operations": 30.87,
      "total": 179.34,
      "electricity_usd_2026_kwh": 0.1049,
      "wacc": 0.1138,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 21.89,
      "electricity": 1.05,
      "site_grid": 2.07,
      "operations": 3.44,
      "total": 28.45,
      "electricity_usd_2026_kwh": 0.1009,
      "wacc": 0.1146,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 27.73,
      "electricity": 1.35,
      "site_grid": 1.74,
      "operations": 5.36,
      "total": 36.17,
      "electricity_usd_2026_kwh": 0.1009,
      "wacc": 0.1146,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 46.89,
      "electricity": 2.83,
      "site_grid": 4.43,
      "operations": 7.96,
      "total": 62.13,
      "electricity_usd_2026_kwh": 0.1009,
      "wacc": 0.1146,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 59.41,
      "electricity": 3.65,
      "site_grid": 3.72,
      "operations": 12.72,
      "total": 79.5,
      "electricity_usd_2026_kwh": 0.1009,
      "wacc": 0.1146,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 103.74,
      "electricity": 6.67,
      "site_grid": 9.81,
      "operations": 18.92,
      "total": 139.15,
      "electricity_usd_2026_kwh": 0.1009,
      "wacc": 0.1146,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 131.43,
      "electricity": 8.59,
      "site_grid": 8.23,
      "operations": 30.87,
      "total": 179.12,
      "electricity_usd_2026_kwh": 0.1009,
      "wacc": 0.1146,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 21.9,
      "electricity": 1.05,
      "site_grid": 2.08,
      "operations": 3.44,
      "total": 28.47,
      "electricity_usd_2026_kwh": 0.1009,
      "wacc": 0.115,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 27.75,
      "electricity": 1.35,
      "site_grid": 1.74,
      "operations": 5.36,
      "total": 36.2,
      "electricity_usd_2026_kwh": 0.1009,
      "wacc": 0.115,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 46.92,
      "electricity": 2.83,
      "site_grid": 4.46,
      "operations": 7.96,
      "total": 62.18,
      "electricity_usd_2026_kwh": 0.1009,
      "wacc": 0.115,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 59.45,
      "electricity": 3.65,
      "site_grid": 3.74,
      "operations": 12.72,
      "total": 79.55,
      "electricity_usd_2026_kwh": 0.1009,
      "wacc": 0.115,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 103.81,
      "electricity": 6.67,
      "site_grid": 9.86,
      "operations": 18.92,
      "total": 139.26,
      "electricity_usd_2026_kwh": 0.1009,
      "wacc": 0.115,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 131.51,
      "electricity": 8.59,
      "site_grid": 8.27,
      "operations": 30.87,
      "total": 179.24,
      "electricity_usd_2026_kwh": 0.1009,
      "wacc": 0.115,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.23,
      "electricity": 1.67,
      "site_grid": 1.33,
      "operations": 3.36,
      "total": 23.59,
      "electricity_usd_2026_kwh": 0.1721,
      "wacc": 0.0408,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.65,
      "electricity": 2.13,
      "site_grid": 1.45,
      "operations": 6.27,
      "total": 31.5,
      "electricity_usd_2026_kwh": 0.1721,
      "wacc": 0.0408,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.92,
      "electricity": 4.53,
      "site_grid": 2.84,
      "operations": 7.79,
      "total": 52.08,
      "electricity_usd_2026_kwh": 0.1721,
      "wacc": 0.0408,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.38,
      "electricity": 5.78,
      "site_grid": 3.1,
      "operations": 14.65,
      "total": 69.91,
      "electricity_usd_2026_kwh": 0.1721,
      "wacc": 0.0408,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.68,
      "electricity": 10.66,
      "site_grid": 6.29,
      "operations": 18.52,
      "total": 117.15,
      "electricity_usd_2026_kwh": 0.1721,
      "wacc": 0.0408,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.61,
      "electricity": 13.62,
      "site_grid": 6.85,
      "operations": 35.08,
      "total": 158.17,
      "electricity_usd_2026_kwh": 0.1721,
      "wacc": 0.0408,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.2,
      "electricity": 1.73,
      "site_grid": 1.3,
      "operations": 3.36,
      "total": 23.6,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.0365,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.47,
      "electricity": 2.21,
      "site_grid": 1.39,
      "operations": 6.27,
      "total": 31.34,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.0365,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.86,
      "electricity": 4.7,
      "site_grid": 2.79,
      "operations": 7.79,
      "total": 52.13,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.0365,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.0,
      "electricity": 6.0,
      "site_grid": 2.98,
      "operations": 14.65,
      "total": 69.62,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.0365,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.54,
      "electricity": 11.06,
      "site_grid": 6.17,
      "operations": 18.52,
      "total": 117.3,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.0365,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.77,
      "electricity": 14.12,
      "site_grid": 6.59,
      "operations": 35.08,
      "total": 157.57,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.0365,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.2,
      "electricity": 1.75,
      "site_grid": 1.31,
      "operations": 3.36,
      "total": 23.62,
      "electricity_usd_2026_kwh": 0.1801,
      "wacc": 0.035,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.41,
      "electricity": 2.23,
      "site_grid": 1.39,
      "operations": 6.27,
      "total": 31.3,
      "electricity_usd_2026_kwh": 0.1801,
      "wacc": 0.035,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.86,
      "electricity": 4.74,
      "site_grid": 2.8,
      "operations": 7.79,
      "total": 52.19,
      "electricity_usd_2026_kwh": 0.1801,
      "wacc": 0.035,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.87,
      "electricity": 6.05,
      "site_grid": 2.97,
      "operations": 14.65,
      "total": 69.53,
      "electricity_usd_2026_kwh": 0.1801,
      "wacc": 0.035,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.54,
      "electricity": 11.16,
      "site_grid": 6.2,
      "operations": 18.52,
      "total": 117.43,
      "electricity_usd_2026_kwh": 0.1801,
      "wacc": 0.035,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.48,
      "electricity": 14.25,
      "site_grid": 6.57,
      "operations": 35.08,
      "total": 157.38,
      "electricity_usd_2026_kwh": 0.1801,
      "wacc": 0.035,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.2,
      "electricity": 1.73,
      "site_grid": 1.32,
      "operations": 3.36,
      "total": 23.62,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.035,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.41,
      "electricity": 2.21,
      "site_grid": 1.4,
      "operations": 6.27,
      "total": 31.29,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.035,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.86,
      "electricity": 4.7,
      "site_grid": 2.83,
      "operations": 7.79,
      "total": 52.17,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.035,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.87,
      "electricity": 6.0,
      "site_grid": 2.99,
      "operations": 14.65,
      "total": 69.51,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.035,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.54,
      "electricity": 11.06,
      "site_grid": 6.26,
      "operations": 18.52,
      "total": 117.38,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.035,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.48,
      "electricity": 14.12,
      "site_grid": 6.62,
      "operations": 35.08,
      "total": 157.31,
      "electricity_usd_2026_kwh": 0.1785,
      "wacc": 0.035,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.2,
      "electricity": 1.67,
      "site_grid": 1.34,
      "operations": 3.36,
      "total": 23.58,
      "electricity_usd_2026_kwh": 0.1721,
      "wacc": 0.035,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.41,
      "electricity": 2.13,
      "site_grid": 1.42,
      "operations": 6.27,
      "total": 31.23,
      "electricity_usd_2026_kwh": 0.1721,
      "wacc": 0.035,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.86,
      "electricity": 4.53,
      "site_grid": 2.87,
      "operations": 7.79,
      "total": 52.05,
      "electricity_usd_2026_kwh": 0.1721,
      "wacc": 0.035,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.87,
      "electricity": 5.78,
      "site_grid": 3.04,
      "operations": 14.65,
      "total": 69.34,
      "electricity_usd_2026_kwh": 0.1721,
      "wacc": 0.035,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.54,
      "electricity": 10.66,
      "site_grid": 6.35,
      "operations": 18.52,
      "total": 117.09,
      "electricity_usd_2026_kwh": 0.1721,
      "wacc": 0.035,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.48,
      "electricity": 13.62,
      "site_grid": 6.73,
      "operations": 35.08,
      "total": 156.91,
      "electricity_usd_2026_kwh": 0.1721,
      "wacc": 0.035,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.2,
      "electricity": 1.58,
      "site_grid": 1.36,
      "operations": 3.36,
      "total": 23.51,
      "electricity_usd_2026_kwh": 0.1626,
      "wacc": 0.035,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.41,
      "electricity": 2.01,
      "site_grid": 1.44,
      "operations": 6.27,
      "total": 31.14,
      "electricity_usd_2026_kwh": 0.1626,
      "wacc": 0.035,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.86,
      "electricity": 4.28,
      "site_grid": 2.92,
      "operations": 7.79,
      "total": 51.85,
      "electricity_usd_2026_kwh": 0.1626,
      "wacc": 0.035,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.87,
      "electricity": 5.46,
      "site_grid": 3.1,
      "operations": 14.65,
      "total": 69.07,
      "electricity_usd_2026_kwh": 0.1626,
      "wacc": 0.035,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.54,
      "electricity": 10.07,
      "site_grid": 6.47,
      "operations": 18.52,
      "total": 116.61,
      "electricity_usd_2026_kwh": 0.1626,
      "wacc": 0.035,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.48,
      "electricity": 12.86,
      "site_grid": 6.85,
      "operations": 35.08,
      "total": 156.27,
      "electricity_usd_2026_kwh": 0.1626,
      "wacc": 0.035,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.2,
      "electricity": 1.52,
      "site_grid": 1.36,
      "operations": 3.36,
      "total": 23.44,
      "electricity_usd_2026_kwh": 0.1562,
      "wacc": 0.035,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.41,
      "electricity": 1.94,
      "site_grid": 1.44,
      "operations": 6.27,
      "total": 31.05,
      "electricity_usd_2026_kwh": 0.1562,
      "wacc": 0.035,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.86,
      "electricity": 4.11,
      "site_grid": 2.91,
      "operations": 7.79,
      "total": 51.66,
      "electricity_usd_2026_kwh": 0.1562,
      "wacc": 0.035,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.87,
      "electricity": 5.25,
      "site_grid": 3.08,
      "operations": 14.65,
      "total": 68.84,
      "electricity_usd_2026_kwh": 0.1562,
      "wacc": 0.035,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.54,
      "electricity": 9.68,
      "site_grid": 6.43,
      "operations": 18.52,
      "total": 116.17,
      "electricity_usd_2026_kwh": 0.1562,
      "wacc": 0.035,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.48,
      "electricity": 12.36,
      "site_grid": 6.81,
      "operations": 35.08,
      "total": 155.73,
      "electricity_usd_2026_kwh": 0.1562,
      "wacc": 0.035,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.2,
      "electricity": 1.55,
      "site_grid": 1.36,
      "operations": 3.36,
      "total": 23.48,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.035,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.41,
      "electricity": 1.98,
      "site_grid": 1.44,
      "operations": 6.27,
      "total": 31.1,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.035,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.86,
      "electricity": 4.19,
      "site_grid": 2.92,
      "operations": 7.79,
      "total": 51.76,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.035,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.87,
      "electricity": 5.35,
      "site_grid": 3.09,
      "operations": 14.65,
      "total": 68.96,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.035,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.54,
      "electricity": 9.87,
      "site_grid": 6.45,
      "operations": 18.52,
      "total": 116.39,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.035,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.48,
      "electricity": 12.61,
      "site_grid": 6.83,
      "operations": 35.08,
      "total": 156.0,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.035,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.2,
      "electricity": 1.62,
      "site_grid": 1.39,
      "operations": 3.36,
      "total": 23.58,
      "electricity_usd_2026_kwh": 0.1674,
      "wacc": 0.0378,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.52,
      "electricity": 2.07,
      "site_grid": 1.5,
      "operations": 6.27,
      "total": 31.37,
      "electricity_usd_2026_kwh": 0.1674,
      "wacc": 0.0378,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.86,
      "electricity": 4.4,
      "site_grid": 2.98,
      "operations": 7.79,
      "total": 52.03,
      "electricity_usd_2026_kwh": 0.1674,
      "wacc": 0.0378,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.12,
      "electricity": 5.62,
      "site_grid": 3.21,
      "operations": 14.65,
      "total": 69.59,
      "electricity_usd_2026_kwh": 0.1674,
      "wacc": 0.0378,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.54,
      "electricity": 10.37,
      "site_grid": 6.6,
      "operations": 18.52,
      "total": 117.03,
      "electricity_usd_2026_kwh": 0.1674,
      "wacc": 0.0378,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.02,
      "electricity": 13.24,
      "site_grid": 7.1,
      "operations": 35.08,
      "total": 157.45,
      "electricity_usd_2026_kwh": 0.1674,
      "wacc": 0.0378,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.2,
      "electricity": 1.56,
      "site_grid": 1.45,
      "operations": 3.36,
      "total": 23.58,
      "electricity_usd_2026_kwh": 0.161,
      "wacc": 0.035,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.41,
      "electricity": 1.99,
      "site_grid": 1.53,
      "operations": 6.27,
      "total": 31.21,
      "electricity_usd_2026_kwh": 0.161,
      "wacc": 0.035,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.86,
      "electricity": 4.23,
      "site_grid": 3.1,
      "operations": 7.79,
      "total": 51.99,
      "electricity_usd_2026_kwh": 0.161,
      "wacc": 0.035,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.87,
      "electricity": 5.41,
      "site_grid": 3.28,
      "operations": 14.65,
      "total": 69.21,
      "electricity_usd_2026_kwh": 0.161,
      "wacc": 0.035,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.54,
      "electricity": 9.97,
      "site_grid": 6.86,
      "operations": 18.52,
      "total": 116.9,
      "electricity_usd_2026_kwh": 0.161,
      "wacc": 0.035,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.48,
      "electricity": 12.74,
      "site_grid": 7.27,
      "operations": 35.08,
      "total": 156.57,
      "electricity_usd_2026_kwh": 0.161,
      "wacc": 0.035,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.2,
      "electricity": 1.48,
      "site_grid": 1.47,
      "operations": 3.36,
      "total": 23.53,
      "electricity_usd_2026_kwh": 0.153,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.41,
      "electricity": 1.9,
      "site_grid": 1.56,
      "operations": 6.27,
      "total": 31.13,
      "electricity_usd_2026_kwh": 0.153,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.86,
      "electricity": 4.02,
      "site_grid": 3.16,
      "operations": 7.79,
      "total": 51.83,
      "electricity_usd_2026_kwh": 0.153,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.87,
      "electricity": 5.14,
      "site_grid": 3.34,
      "operations": 14.65,
      "total": 69.0,
      "electricity_usd_2026_kwh": 0.153,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.54,
      "electricity": 9.48,
      "site_grid": 6.98,
      "operations": 18.52,
      "total": 116.53,
      "electricity_usd_2026_kwh": 0.153,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.48,
      "electricity": 12.11,
      "site_grid": 7.39,
      "operations": 35.08,
      "total": 156.06,
      "electricity_usd_2026_kwh": 0.153,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.2,
      "electricity": 1.59,
      "site_grid": 1.48,
      "operations": 3.36,
      "total": 23.64,
      "electricity_usd_2026_kwh": 0.1642,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.41,
      "electricity": 2.03,
      "site_grid": 1.57,
      "operations": 6.27,
      "total": 31.28,
      "electricity_usd_2026_kwh": 0.1642,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.86,
      "electricity": 4.32,
      "site_grid": 3.17,
      "operations": 7.79,
      "total": 52.14,
      "electricity_usd_2026_kwh": 0.1642,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.87,
      "electricity": 5.51,
      "site_grid": 3.36,
      "operations": 14.65,
      "total": 69.39,
      "electricity_usd_2026_kwh": 0.1642,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.54,
      "electricity": 10.17,
      "site_grid": 7.02,
      "operations": 18.52,
      "total": 117.25,
      "electricity_usd_2026_kwh": 0.1642,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.48,
      "electricity": 12.99,
      "site_grid": 7.43,
      "operations": 35.08,
      "total": 156.98,
      "electricity_usd_2026_kwh": 0.1642,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.2,
      "electricity": 1.78,
      "site_grid": 1.68,
      "operations": 3.36,
      "total": 24.02,
      "electricity_usd_2026_kwh": 0.1833,
      "wacc": 0.0382,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.54,
      "electricity": 2.27,
      "site_grid": 1.81,
      "operations": 6.27,
      "total": 31.89,
      "electricity_usd_2026_kwh": 0.1833,
      "wacc": 0.0382,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.86,
      "electricity": 4.82,
      "site_grid": 3.59,
      "operations": 7.79,
      "total": 53.06,
      "electricity_usd_2026_kwh": 0.1833,
      "wacc": 0.0382,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.15,
      "electricity": 6.16,
      "site_grid": 3.87,
      "operations": 14.65,
      "total": 70.83,
      "electricity_usd_2026_kwh": 0.1833,
      "wacc": 0.0382,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.54,
      "electricity": 11.35,
      "site_grid": 7.95,
      "operations": 18.52,
      "total": 119.37,
      "electricity_usd_2026_kwh": 0.1833,
      "wacc": 0.0382,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.1,
      "electricity": 14.5,
      "site_grid": 8.57,
      "operations": 35.08,
      "total": 160.26,
      "electricity_usd_2026_kwh": 0.1833,
      "wacc": 0.0382,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.48,
      "electricity": 1.69,
      "site_grid": 1.84,
      "operations": 3.36,
      "total": 24.36,
      "electricity_usd_2026_kwh": 0.1737,
      "wacc": 0.0483,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.95,
      "electricity": 2.15,
      "site_grid": 1.98,
      "operations": 6.27,
      "total": 32.36,
      "electricity_usd_2026_kwh": 0.1737,
      "wacc": 0.0483,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.44,
      "electricity": 4.57,
      "site_grid": 3.94,
      "operations": 7.79,
      "total": 53.74,
      "electricity_usd_2026_kwh": 0.1737,
      "wacc": 0.0483,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.04,
      "electricity": 5.84,
      "site_grid": 4.24,
      "operations": 14.65,
      "total": 71.76,
      "electricity_usd_2026_kwh": 0.1737,
      "wacc": 0.0483,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.84,
      "electricity": 10.76,
      "site_grid": 8.71,
      "operations": 18.52,
      "total": 120.83,
      "electricity_usd_2026_kwh": 0.1737,
      "wacc": 0.0483,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.07,
      "electricity": 13.74,
      "site_grid": 9.38,
      "operations": 35.08,
      "total": 162.28,
      "electricity_usd_2026_kwh": 0.1737,
      "wacc": 0.0483,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.56,
      "electricity": 1.61,
      "site_grid": 1.81,
      "operations": 3.36,
      "total": 24.34,
      "electricity_usd_2026_kwh": 0.1658,
      "wacc": 0.0508,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.06,
      "electricity": 2.05,
      "site_grid": 1.94,
      "operations": 6.27,
      "total": 32.32,
      "electricity_usd_2026_kwh": 0.1658,
      "wacc": 0.0508,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.62,
      "electricity": 4.36,
      "site_grid": 3.88,
      "operations": 7.79,
      "total": 53.65,
      "electricity_usd_2026_kwh": 0.1658,
      "wacc": 0.0508,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.26,
      "electricity": 5.57,
      "site_grid": 4.16,
      "operations": 14.65,
      "total": 71.64,
      "electricity_usd_2026_kwh": 0.1658,
      "wacc": 0.0508,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.23,
      "electricity": 10.27,
      "site_grid": 8.58,
      "operations": 18.52,
      "total": 120.6,
      "electricity_usd_2026_kwh": 0.1658,
      "wacc": 0.0508,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.55,
      "electricity": 13.11,
      "site_grid": 9.21,
      "operations": 35.08,
      "total": 161.96,
      "electricity_usd_2026_kwh": 0.1658,
      "wacc": 0.0508,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.59,
      "electricity": 1.55,
      "site_grid": 1.8,
      "operations": 3.36,
      "total": 24.3,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.0516,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.09,
      "electricity": 1.98,
      "site_grid": 1.93,
      "operations": 6.27,
      "total": 32.27,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.0516,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.68,
      "electricity": 4.19,
      "site_grid": 3.85,
      "operations": 7.79,
      "total": 53.51,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.0516,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.33,
      "electricity": 5.35,
      "site_grid": 4.13,
      "operations": 14.65,
      "total": 71.46,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.0516,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.36,
      "electricity": 9.87,
      "site_grid": 8.52,
      "operations": 18.52,
      "total": 120.28,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.0516,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.72,
      "electricity": 12.61,
      "site_grid": 9.14,
      "operations": 35.08,
      "total": 161.55,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.0516,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.7,
      "electricity": 1.55,
      "site_grid": 1.85,
      "operations": 3.36,
      "total": 24.45,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.052,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.11,
      "electricity": 1.98,
      "site_grid": 1.94,
      "operations": 6.27,
      "total": 32.29,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.052,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.92,
      "electricity": 4.19,
      "site_grid": 3.95,
      "operations": 7.79,
      "total": 53.86,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.052,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.37,
      "electricity": 5.35,
      "site_grid": 4.15,
      "operations": 14.65,
      "total": 71.52,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.052,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.89,
      "electricity": 9.87,
      "site_grid": 8.75,
      "operations": 18.52,
      "total": 121.03,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.052,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.79,
      "electricity": 12.61,
      "site_grid": 9.18,
      "operations": 35.08,
      "total": 161.67,
      "electricity_usd_2026_kwh": 0.1594,
      "wacc": 0.052,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.84,
      "electricity": 1.15,
      "site_grid": 1.39,
      "operations": 3.32,
      "total": 23.71,
      "electricity_usd_2026_kwh": 0.1189,
      "wacc": 0.0588,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.44,
      "electricity": 1.48,
      "site_grid": 1.4,
      "operations": 6.03,
      "total": 31.34,
      "electricity_usd_2026_kwh": 0.1189,
      "wacc": 0.0588,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.22,
      "electricity": 3.13,
      "site_grid": 2.98,
      "operations": 7.7,
      "total": 52.04,
      "electricity_usd_2026_kwh": 0.1189,
      "wacc": 0.0588,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.07,
      "electricity": 4.0,
      "site_grid": 3.01,
      "operations": 14.13,
      "total": 69.21,
      "electricity_usd_2026_kwh": 0.1189,
      "wacc": 0.0588,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.56,
      "electricity": 7.37,
      "site_grid": 6.6,
      "operations": 18.32,
      "total": 116.86,
      "electricity_usd_2026_kwh": 0.1189,
      "wacc": 0.0588,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.35,
      "electricity": 9.42,
      "site_grid": 6.65,
      "operations": 33.94,
      "total": 156.37,
      "electricity_usd_2026_kwh": 0.1189,
      "wacc": 0.0588,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.7,
      "electricity": 1.2,
      "site_grid": 1.33,
      "operations": 3.32,
      "total": 23.55,
      "electricity_usd_2026_kwh": 0.1233,
      "wacc": 0.0545,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.26,
      "electricity": 1.53,
      "site_grid": 1.35,
      "operations": 6.03,
      "total": 31.17,
      "electricity_usd_2026_kwh": 0.1233,
      "wacc": 0.0545,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.92,
      "electricity": 3.25,
      "site_grid": 2.86,
      "operations": 7.7,
      "total": 51.72,
      "electricity_usd_2026_kwh": 0.1233,
      "wacc": 0.0545,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.69,
      "electricity": 4.15,
      "site_grid": 2.9,
      "operations": 14.13,
      "total": 68.86,
      "electricity_usd_2026_kwh": 0.1233,
      "wacc": 0.0545,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.88,
      "electricity": 7.64,
      "site_grid": 6.32,
      "operations": 18.32,
      "total": 116.17,
      "electricity_usd_2026_kwh": 0.1233,
      "wacc": 0.0545,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.5,
      "electricity": 9.77,
      "site_grid": 6.4,
      "operations": 33.94,
      "total": 155.62,
      "electricity_usd_2026_kwh": 0.1233,
      "wacc": 0.0545,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.37,
      "electricity": 1.21,
      "site_grid": 1.25,
      "operations": 3.32,
      "total": 23.15,
      "electricity_usd_2026_kwh": 0.1244,
      "wacc": 0.0447,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.85,
      "electricity": 1.54,
      "site_grid": 1.29,
      "operations": 6.03,
      "total": 30.71,
      "electricity_usd_2026_kwh": 0.1244,
      "wacc": 0.0447,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.22,
      "electricity": 3.27,
      "site_grid": 2.68,
      "operations": 7.7,
      "total": 50.88,
      "electricity_usd_2026_kwh": 0.1244,
      "wacc": 0.0447,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.82,
      "electricity": 4.19,
      "site_grid": 2.75,
      "operations": 14.13,
      "total": 67.89,
      "electricity_usd_2026_kwh": 0.1244,
      "wacc": 0.0447,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.35,
      "electricity": 7.71,
      "site_grid": 5.93,
      "operations": 18.32,
      "total": 114.31,
      "electricity_usd_2026_kwh": 0.1244,
      "wacc": 0.0447,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.58,
      "electricity": 9.86,
      "site_grid": 6.09,
      "operations": 33.94,
      "total": 153.48,
      "electricity_usd_2026_kwh": 0.1244,
      "wacc": 0.0447,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.55,
      "electricity": 1.2,
      "site_grid": 1.31,
      "operations": 3.32,
      "total": 23.38,
      "electricity_usd_2026_kwh": 0.1233,
      "wacc": 0.0502,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.08,
      "electricity": 1.53,
      "site_grid": 1.34,
      "operations": 6.03,
      "total": 30.97,
      "electricity_usd_2026_kwh": 0.1233,
      "wacc": 0.0502,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.61,
      "electricity": 3.25,
      "site_grid": 2.81,
      "operations": 7.7,
      "total": 51.36,
      "electricity_usd_2026_kwh": 0.1233,
      "wacc": 0.0502,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.3,
      "electricity": 4.15,
      "site_grid": 2.86,
      "operations": 14.13,
      "total": 68.44,
      "electricity_usd_2026_kwh": 0.1233,
      "wacc": 0.0502,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.2,
      "electricity": 7.64,
      "site_grid": 6.22,
      "operations": 18.32,
      "total": 115.39,
      "electricity_usd_2026_kwh": 0.1233,
      "wacc": 0.0502,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.65,
      "electricity": 9.77,
      "site_grid": 6.34,
      "operations": 33.94,
      "total": 154.7,
      "electricity_usd_2026_kwh": 0.1233,
      "wacc": 0.0502,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.62,
      "electricity": 1.15,
      "site_grid": 1.35,
      "operations": 3.32,
      "total": 23.44,
      "electricity_usd_2026_kwh": 0.1189,
      "wacc": 0.0521,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.16,
      "electricity": 1.48,
      "site_grid": 1.37,
      "operations": 6.03,
      "total": 31.03,
      "electricity_usd_2026_kwh": 0.1189,
      "wacc": 0.0521,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.74,
      "electricity": 3.13,
      "site_grid": 2.89,
      "operations": 7.7,
      "total": 51.47,
      "electricity_usd_2026_kwh": 0.1189,
      "wacc": 0.0521,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.47,
      "electricity": 4.0,
      "site_grid": 2.94,
      "operations": 14.13,
      "total": 68.54,
      "electricity_usd_2026_kwh": 0.1189,
      "wacc": 0.0521,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.5,
      "electricity": 7.37,
      "site_grid": 6.4,
      "operations": 18.32,
      "total": 115.6,
      "electricity_usd_2026_kwh": 0.1189,
      "wacc": 0.0521,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.02,
      "electricity": 9.42,
      "site_grid": 6.51,
      "operations": 33.94,
      "total": 154.9,
      "electricity_usd_2026_kwh": 0.1189,
      "wacc": 0.0521,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.48,
      "electricity": 1.09,
      "site_grid": 1.34,
      "operations": 3.32,
      "total": 23.23,
      "electricity_usd_2026_kwh": 0.1123,
      "wacc": 0.0481,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.99,
      "electricity": 1.39,
      "site_grid": 1.37,
      "operations": 6.03,
      "total": 30.78,
      "electricity_usd_2026_kwh": 0.1123,
      "wacc": 0.0481,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.46,
      "electricity": 2.96,
      "site_grid": 2.86,
      "operations": 7.7,
      "total": 50.98,
      "electricity_usd_2026_kwh": 0.1123,
      "wacc": 0.0481,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.11,
      "electricity": 3.78,
      "site_grid": 2.93,
      "operations": 14.13,
      "total": 67.95,
      "electricity_usd_2026_kwh": 0.1123,
      "wacc": 0.0481,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.87,
      "electricity": 6.96,
      "site_grid": 6.33,
      "operations": 18.32,
      "total": 114.49,
      "electricity_usd_2026_kwh": 0.1123,
      "wacc": 0.0481,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.23,
      "electricity": 8.9,
      "site_grid": 6.48,
      "operations": 33.94,
      "total": 153.55,
      "electricity_usd_2026_kwh": 0.1123,
      "wacc": 0.0481,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.38,
      "electricity": 1.05,
      "site_grid": 1.3,
      "operations": 3.32,
      "total": 23.05,
      "electricity_usd_2026_kwh": 0.1079,
      "wacc": 0.0451,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.87,
      "electricity": 1.34,
      "site_grid": 1.33,
      "operations": 6.03,
      "total": 30.57,
      "electricity_usd_2026_kwh": 0.1079,
      "wacc": 0.0451,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.25,
      "electricity": 2.84,
      "site_grid": 2.78,
      "operations": 7.7,
      "total": 50.57,
      "electricity_usd_2026_kwh": 0.1079,
      "wacc": 0.0451,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.85,
      "electricity": 3.63,
      "site_grid": 2.86,
      "operations": 14.13,
      "total": 67.47,
      "electricity_usd_2026_kwh": 0.1079,
      "wacc": 0.0451,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.4,
      "electricity": 6.69,
      "site_grid": 6.16,
      "operations": 18.32,
      "total": 113.57,
      "electricity_usd_2026_kwh": 0.1079,
      "wacc": 0.0451,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.64,
      "electricity": 8.55,
      "site_grid": 6.33,
      "operations": 33.94,
      "total": 152.47,
      "electricity_usd_2026_kwh": 0.1079,
      "wacc": 0.0451,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.55,
      "electricity": 1.07,
      "site_grid": 1.35,
      "operations": 3.32,
      "total": 23.29,
      "electricity_usd_2026_kwh": 0.1101,
      "wacc": 0.05,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.07,
      "electricity": 1.37,
      "site_grid": 1.38,
      "operations": 6.03,
      "total": 30.84,
      "electricity_usd_2026_kwh": 0.1101,
      "wacc": 0.05,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.59,
      "electricity": 2.9,
      "site_grid": 2.89,
      "operations": 7.7,
      "total": 51.09,
      "electricity_usd_2026_kwh": 0.1101,
      "wacc": 0.05,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.28,
      "electricity": 3.71,
      "site_grid": 2.95,
      "operations": 14.13,
      "total": 68.07,
      "electricity_usd_2026_kwh": 0.1101,
      "wacc": 0.05,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.17,
      "electricity": 6.82,
      "site_grid": 6.4,
      "operations": 18.32,
      "total": 114.72,
      "electricity_usd_2026_kwh": 0.1101,
      "wacc": 0.05,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.61,
      "electricity": 8.73,
      "site_grid": 6.53,
      "operations": 33.94,
      "total": 153.81,
      "electricity_usd_2026_kwh": 0.1101,
      "wacc": 0.05,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.74,
      "electricity": 1.12,
      "site_grid": 1.44,
      "operations": 3.32,
      "total": 23.62,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0558,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.31,
      "electricity": 1.44,
      "site_grid": 1.46,
      "operations": 6.03,
      "total": 31.23,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0558,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.01,
      "electricity": 3.04,
      "site_grid": 3.08,
      "operations": 7.7,
      "total": 51.83,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0558,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.8,
      "electricity": 3.89,
      "site_grid": 3.12,
      "operations": 14.13,
      "total": 68.94,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0558,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.09,
      "electricity": 7.17,
      "site_grid": 6.82,
      "operations": 18.32,
      "total": 116.39,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0558,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.75,
      "electricity": 9.16,
      "site_grid": 6.9,
      "operations": 33.94,
      "total": 155.75,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0558,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.48,
      "electricity": 1.08,
      "site_grid": 1.42,
      "operations": 3.32,
      "total": 23.3,
      "electricity_usd_2026_kwh": 0.1112,
      "wacc": 0.0481,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.99,
      "electricity": 1.38,
      "site_grid": 1.45,
      "operations": 6.03,
      "total": 30.85,
      "electricity_usd_2026_kwh": 0.1112,
      "wacc": 0.0481,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.46,
      "electricity": 2.93,
      "site_grid": 3.04,
      "operations": 7.7,
      "total": 51.13,
      "electricity_usd_2026_kwh": 0.1112,
      "wacc": 0.0481,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.12,
      "electricity": 3.74,
      "site_grid": 3.11,
      "operations": 14.13,
      "total": 68.09,
      "electricity_usd_2026_kwh": 0.1112,
      "wacc": 0.0481,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.88,
      "electricity": 6.89,
      "site_grid": 6.72,
      "operations": 18.32,
      "total": 114.82,
      "electricity_usd_2026_kwh": 0.1112,
      "wacc": 0.0481,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.24,
      "electricity": 8.81,
      "site_grid": 6.87,
      "operations": 33.94,
      "total": 153.87,
      "electricity_usd_2026_kwh": 0.1112,
      "wacc": 0.0481,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.22,
      "electricity": 1.03,
      "site_grid": 1.36,
      "operations": 3.32,
      "total": 22.93,
      "electricity_usd_2026_kwh": 0.1057,
      "wacc": 0.0356,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.48,
      "electricity": 1.31,
      "site_grid": 1.37,
      "operations": 6.03,
      "total": 30.19,
      "electricity_usd_2026_kwh": 0.1057,
      "wacc": 0.0356,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.89,
      "electricity": 2.78,
      "site_grid": 2.92,
      "operations": 7.7,
      "total": 50.29,
      "electricity_usd_2026_kwh": 0.1057,
      "wacc": 0.0356,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.01,
      "electricity": 3.56,
      "site_grid": 2.94,
      "operations": 14.13,
      "total": 66.64,
      "electricity_usd_2026_kwh": 0.1057,
      "wacc": 0.0356,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.61,
      "electricity": 6.55,
      "site_grid": 6.45,
      "operations": 18.32,
      "total": 112.94,
      "electricity_usd_2026_kwh": 0.1057,
      "wacc": 0.0356,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.8,
      "electricity": 8.38,
      "site_grid": 6.5,
      "operations": 33.94,
      "total": 150.62,
      "electricity_usd_2026_kwh": 0.1057,
      "wacc": 0.0356,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.26,
      "electricity": 1.1,
      "site_grid": 1.38,
      "operations": 3.32,
      "total": 23.06,
      "electricity_usd_2026_kwh": 0.1134,
      "wacc": 0.0412,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.71,
      "electricity": 1.41,
      "site_grid": 1.42,
      "operations": 6.03,
      "total": 30.56,
      "electricity_usd_2026_kwh": 0.1134,
      "wacc": 0.0412,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.97,
      "electricity": 2.98,
      "site_grid": 2.96,
      "operations": 7.7,
      "total": 50.61,
      "electricity_usd_2026_kwh": 0.1134,
      "wacc": 0.0412,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.5,
      "electricity": 3.82,
      "site_grid": 3.05,
      "operations": 14.13,
      "total": 67.5,
      "electricity_usd_2026_kwh": 0.1134,
      "wacc": 0.0412,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.79,
      "electricity": 7.03,
      "site_grid": 6.54,
      "operations": 18.32,
      "total": 113.68,
      "electricity_usd_2026_kwh": 0.1134,
      "wacc": 0.0412,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.88,
      "electricity": 8.99,
      "site_grid": 6.75,
      "operations": 33.94,
      "total": 152.57,
      "electricity_usd_2026_kwh": 0.1134,
      "wacc": 0.0412,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.75,
      "electricity": 1.23,
      "site_grid": 1.74,
      "operations": 3.32,
      "total": 24.04,
      "electricity_usd_2026_kwh": 0.1266,
      "wacc": 0.0562,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.33,
      "electricity": 1.57,
      "site_grid": 1.76,
      "operations": 6.03,
      "total": 31.68,
      "electricity_usd_2026_kwh": 0.1266,
      "wacc": 0.0562,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.04,
      "electricity": 3.33,
      "site_grid": 3.72,
      "operations": 7.7,
      "total": 52.79,
      "electricity_usd_2026_kwh": 0.1266,
      "wacc": 0.0562,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.84,
      "electricity": 4.26,
      "site_grid": 3.76,
      "operations": 14.13,
      "total": 69.99,
      "electricity_usd_2026_kwh": 0.1266,
      "wacc": 0.0562,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.15,
      "electricity": 7.85,
      "site_grid": 8.23,
      "operations": 18.32,
      "total": 118.55,
      "electricity_usd_2026_kwh": 0.1266,
      "wacc": 0.0562,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.83,
      "electricity": 10.04,
      "site_grid": 8.32,
      "operations": 33.94,
      "total": 158.13,
      "electricity_usd_2026_kwh": 0.1266,
      "wacc": 0.0562,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.09,
      "electricity": 1.17,
      "site_grid": 1.92,
      "operations": 3.32,
      "total": 24.5,
      "electricity_usd_2026_kwh": 0.12,
      "wacc": 0.0663,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.75,
      "electricity": 1.49,
      "site_grid": 1.92,
      "operations": 6.03,
      "total": 32.18,
      "electricity_usd_2026_kwh": 0.12,
      "wacc": 0.0663,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.75,
      "electricity": 3.16,
      "site_grid": 4.11,
      "operations": 7.7,
      "total": 53.73,
      "electricity_usd_2026_kwh": 0.12,
      "wacc": 0.0663,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.73,
      "electricity": 4.04,
      "site_grid": 4.11,
      "operations": 14.13,
      "total": 71.01,
      "electricity_usd_2026_kwh": 0.12,
      "wacc": 0.0663,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.74,
      "electricity": 7.44,
      "site_grid": 9.1,
      "operations": 18.32,
      "total": 120.61,
      "electricity_usd_2026_kwh": 0.12,
      "wacc": 0.0663,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.82,
      "electricity": 9.51,
      "site_grid": 9.09,
      "operations": 33.94,
      "total": 160.36,
      "electricity_usd_2026_kwh": 0.12,
      "wacc": 0.0663,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.17,
      "electricity": 1.11,
      "site_grid": 1.89,
      "operations": 3.32,
      "total": 24.5,
      "electricity_usd_2026_kwh": 0.1145,
      "wacc": 0.0688,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.85,
      "electricity": 1.42,
      "site_grid": 1.88,
      "operations": 6.03,
      "total": 32.18,
      "electricity_usd_2026_kwh": 0.1145,
      "wacc": 0.0688,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.93,
      "electricity": 3.01,
      "site_grid": 4.05,
      "operations": 7.7,
      "total": 53.7,
      "electricity_usd_2026_kwh": 0.1145,
      "wacc": 0.0688,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.96,
      "electricity": 3.85,
      "site_grid": 4.03,
      "operations": 14.13,
      "total": 70.97,
      "electricity_usd_2026_kwh": 0.1145,
      "wacc": 0.0688,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.13,
      "electricity": 7.1,
      "site_grid": 8.96,
      "operations": 18.32,
      "total": 120.51,
      "electricity_usd_2026_kwh": 0.1145,
      "wacc": 0.0688,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.31,
      "electricity": 9.08,
      "site_grid": 8.92,
      "operations": 33.94,
      "total": 160.25,
      "electricity_usd_2026_kwh": 0.1145,
      "wacc": 0.0688,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.2,
      "electricity": 1.07,
      "site_grid": 1.88,
      "operations": 3.32,
      "total": 24.47,
      "electricity_usd_2026_kwh": 0.1101,
      "wacc": 0.0696,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.89,
      "electricity": 1.37,
      "site_grid": 1.87,
      "operations": 6.03,
      "total": 32.15,
      "electricity_usd_2026_kwh": 0.1101,
      "wacc": 0.0696,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.99,
      "electricity": 2.9,
      "site_grid": 4.02,
      "operations": 7.7,
      "total": 53.61,
      "electricity_usd_2026_kwh": 0.1101,
      "wacc": 0.0696,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.03,
      "electricity": 3.71,
      "site_grid": 4.0,
      "operations": 14.13,
      "total": 70.86,
      "electricity_usd_2026_kwh": 0.1101,
      "wacc": 0.0696,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.27,
      "electricity": 6.82,
      "site_grid": 8.89,
      "operations": 18.32,
      "total": 120.31,
      "electricity_usd_2026_kwh": 0.1101,
      "wacc": 0.0696,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.48,
      "electricity": 8.73,
      "site_grid": 8.84,
      "operations": 33.94,
      "total": 159.99,
      "electricity_usd_2026_kwh": 0.1101,
      "wacc": 0.0696,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.21,
      "electricity": 1.07,
      "site_grid": 1.89,
      "operations": 3.32,
      "total": 24.49,
      "electricity_usd_2026_kwh": 0.1101,
      "wacc": 0.07,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.9,
      "electricity": 1.37,
      "site_grid": 1.87,
      "operations": 6.03,
      "total": 32.17,
      "electricity_usd_2026_kwh": 0.1101,
      "wacc": 0.07,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.02,
      "electricity": 2.9,
      "site_grid": 4.04,
      "operations": 7.7,
      "total": 53.66,
      "electricity_usd_2026_kwh": 0.1101,
      "wacc": 0.07,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.07,
      "electricity": 3.71,
      "site_grid": 4.01,
      "operations": 14.13,
      "total": 70.92,
      "electricity_usd_2026_kwh": 0.1101,
      "wacc": 0.07,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.33,
      "electricity": 6.82,
      "site_grid": 8.94,
      "operations": 18.32,
      "total": 120.42,
      "electricity_usd_2026_kwh": 0.1101,
      "wacc": 0.07,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.56,
      "electricity": 8.73,
      "site_grid": 8.88,
      "operations": 33.94,
      "total": 160.11,
      "electricity_usd_2026_kwh": 0.1101,
      "wacc": 0.07,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.51,
      "electricity": 1.42,
      "site_grid": 1.37,
      "operations": 3.28,
      "total": 23.58,
      "electricity_usd_2026_kwh": 0.1449,
      "wacc": 0.0538,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.04,
      "electricity": 1.82,
      "site_grid": 1.42,
      "operations": 5.89,
      "total": 31.16,
      "electricity_usd_2026_kwh": 0.1449,
      "wacc": 0.0538,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.53,
      "electricity": 3.85,
      "site_grid": 2.93,
      "operations": 7.62,
      "total": 51.92,
      "electricity_usd_2026_kwh": 0.1449,
      "wacc": 0.0538,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.22,
      "electricity": 4.92,
      "site_grid": 3.04,
      "operations": 13.83,
      "total": 69.02,
      "electricity_usd_2026_kwh": 0.1449,
      "wacc": 0.0538,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.02,
      "electricity": 9.06,
      "site_grid": 6.47,
      "operations": 18.14,
      "total": 116.7,
      "electricity_usd_2026_kwh": 0.1449,
      "wacc": 0.0538,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.48,
      "electricity": 11.6,
      "site_grid": 6.72,
      "operations": 33.29,
      "total": 156.09,
      "electricity_usd_2026_kwh": 0.1449,
      "wacc": 0.0538,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.37,
      "electricity": 1.47,
      "site_grid": 1.31,
      "operations": 3.28,
      "total": 23.44,
      "electricity_usd_2026_kwh": 0.1503,
      "wacc": 0.0495,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.86,
      "electricity": 1.88,
      "site_grid": 1.37,
      "operations": 5.89,
      "total": 31.0,
      "electricity_usd_2026_kwh": 0.1503,
      "wacc": 0.0495,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.22,
      "electricity": 3.99,
      "site_grid": 2.8,
      "operations": 7.62,
      "total": 51.63,
      "electricity_usd_2026_kwh": 0.1503,
      "wacc": 0.0495,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.84,
      "electricity": 5.11,
      "site_grid": 2.93,
      "operations": 13.83,
      "total": 68.71,
      "electricity_usd_2026_kwh": 0.1503,
      "wacc": 0.0495,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.35,
      "electricity": 9.4,
      "site_grid": 6.2,
      "operations": 18.14,
      "total": 116.09,
      "electricity_usd_2026_kwh": 0.1503,
      "wacc": 0.0495,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.63,
      "electricity": 12.03,
      "site_grid": 6.47,
      "operations": 33.29,
      "total": 155.42,
      "electricity_usd_2026_kwh": 0.1503,
      "wacc": 0.0495,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.06,
      "electricity": 1.49,
      "site_grid": 1.23,
      "operations": 3.28,
      "total": 23.06,
      "electricity_usd_2026_kwh": 0.1516,
      "wacc": 0.0397,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.46,
      "electricity": 1.9,
      "site_grid": 1.3,
      "operations": 5.89,
      "total": 30.55,
      "electricity_usd_2026_kwh": 0.1516,
      "wacc": 0.0397,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.55,
      "electricity": 4.03,
      "site_grid": 2.63,
      "operations": 7.62,
      "total": 50.83,
      "electricity_usd_2026_kwh": 0.1516,
      "wacc": 0.0397,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.99,
      "electricity": 5.15,
      "site_grid": 2.78,
      "operations": 13.83,
      "total": 67.75,
      "electricity_usd_2026_kwh": 0.1516,
      "wacc": 0.0397,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.87,
      "electricity": 9.48,
      "site_grid": 5.82,
      "operations": 18.14,
      "total": 114.32,
      "electricity_usd_2026_kwh": 0.1516,
      "wacc": 0.0397,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.74,
      "electricity": 12.13,
      "site_grid": 6.15,
      "operations": 33.29,
      "total": 153.31,
      "electricity_usd_2026_kwh": 0.1516,
      "wacc": 0.0397,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.23,
      "electricity": 1.47,
      "site_grid": 1.29,
      "operations": 3.28,
      "total": 23.27,
      "electricity_usd_2026_kwh": 0.1503,
      "wacc": 0.0452,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.69,
      "electricity": 1.88,
      "site_grid": 1.35,
      "operations": 5.89,
      "total": 30.81,
      "electricity_usd_2026_kwh": 0.1503,
      "wacc": 0.0452,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.92,
      "electricity": 3.99,
      "site_grid": 2.75,
      "operations": 7.62,
      "total": 51.28,
      "electricity_usd_2026_kwh": 0.1503,
      "wacc": 0.0452,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.46,
      "electricity": 5.11,
      "site_grid": 2.89,
      "operations": 13.83,
      "total": 68.3,
      "electricity_usd_2026_kwh": 0.1503,
      "wacc": 0.0452,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.68,
      "electricity": 9.4,
      "site_grid": 6.09,
      "operations": 18.14,
      "total": 115.31,
      "electricity_usd_2026_kwh": 0.1503,
      "wacc": 0.0452,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.8,
      "electricity": 12.03,
      "site_grid": 6.4,
      "operations": 33.29,
      "total": 154.51,
      "electricity_usd_2026_kwh": 0.1503,
      "wacc": 0.0452,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.29,
      "electricity": 1.42,
      "site_grid": 1.32,
      "operations": 3.28,
      "total": 23.32,
      "electricity_usd_2026_kwh": 0.1449,
      "wacc": 0.0471,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.76,
      "electricity": 1.82,
      "site_grid": 1.39,
      "operations": 5.89,
      "total": 30.86,
      "electricity_usd_2026_kwh": 0.1449,
      "wacc": 0.0471,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.05,
      "electricity": 3.85,
      "site_grid": 2.84,
      "operations": 7.62,
      "total": 51.35,
      "electricity_usd_2026_kwh": 0.1449,
      "wacc": 0.0471,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.63,
      "electricity": 4.92,
      "site_grid": 2.97,
      "operations": 13.83,
      "total": 68.36,
      "electricity_usd_2026_kwh": 0.1449,
      "wacc": 0.0471,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.97,
      "electricity": 9.06,
      "site_grid": 6.27,
      "operations": 18.14,
      "total": 115.45,
      "electricity_usd_2026_kwh": 0.1449,
      "wacc": 0.0471,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.16,
      "electricity": 11.6,
      "site_grid": 6.57,
      "operations": 33.29,
      "total": 154.62,
      "electricity_usd_2026_kwh": 0.1449,
      "wacc": 0.0471,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.16,
      "electricity": 1.34,
      "site_grid": 1.31,
      "operations": 3.28,
      "total": 23.1,
      "electricity_usd_2026_kwh": 0.1368,
      "wacc": 0.0431,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.6,
      "electricity": 1.72,
      "site_grid": 1.38,
      "operations": 5.89,
      "total": 30.58,
      "electricity_usd_2026_kwh": 0.1368,
      "wacc": 0.0431,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.77,
      "electricity": 3.64,
      "site_grid": 2.81,
      "operations": 7.62,
      "total": 50.83,
      "electricity_usd_2026_kwh": 0.1368,
      "wacc": 0.0431,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.28,
      "electricity": 4.65,
      "site_grid": 2.96,
      "operations": 13.83,
      "total": 67.72,
      "electricity_usd_2026_kwh": 0.1368,
      "wacc": 0.0431,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.35,
      "electricity": 8.56,
      "site_grid": 6.21,
      "operations": 18.14,
      "total": 114.26,
      "electricity_usd_2026_kwh": 0.1368,
      "wacc": 0.0431,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.38,
      "electricity": 10.95,
      "site_grid": 6.54,
      "operations": 33.29,
      "total": 153.17,
      "electricity_usd_2026_kwh": 0.1368,
      "wacc": 0.0431,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.06,
      "electricity": 1.29,
      "site_grid": 1.27,
      "operations": 3.28,
      "total": 22.91,
      "electricity_usd_2026_kwh": 0.1315,
      "wacc": 0.0401,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.48,
      "electricity": 1.65,
      "site_grid": 1.35,
      "operations": 5.89,
      "total": 30.36,
      "electricity_usd_2026_kwh": 0.1315,
      "wacc": 0.0401,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.56,
      "electricity": 3.49,
      "site_grid": 2.73,
      "operations": 7.62,
      "total": 50.4,
      "electricity_usd_2026_kwh": 0.1315,
      "wacc": 0.0401,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.02,
      "electricity": 4.47,
      "site_grid": 2.89,
      "operations": 13.83,
      "total": 67.2,
      "electricity_usd_2026_kwh": 0.1315,
      "wacc": 0.0401,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.88,
      "electricity": 8.23,
      "site_grid": 6.03,
      "operations": 18.14,
      "total": 113.29,
      "electricity_usd_2026_kwh": 0.1315,
      "wacc": 0.0401,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.8,
      "electricity": 10.52,
      "site_grid": 6.39,
      "operations": 33.29,
      "total": 152.0,
      "electricity_usd_2026_kwh": 0.1315,
      "wacc": 0.0401,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.22,
      "electricity": 1.31,
      "site_grid": 1.32,
      "operations": 3.28,
      "total": 23.15,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.045,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.68,
      "electricity": 1.68,
      "site_grid": 1.39,
      "operations": 5.89,
      "total": 30.64,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.045,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.9,
      "electricity": 3.56,
      "site_grid": 2.84,
      "operations": 7.62,
      "total": 50.92,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.045,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.45,
      "electricity": 4.56,
      "site_grid": 2.98,
      "operations": 13.83,
      "total": 67.82,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.045,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.64,
      "electricity": 8.39,
      "site_grid": 6.28,
      "operations": 18.14,
      "total": 114.46,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.045,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.75,
      "electricity": 10.74,
      "site_grid": 6.59,
      "operations": 33.29,
      "total": 153.38,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.045,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.41,
      "electricity": 1.38,
      "site_grid": 1.41,
      "operations": 3.28,
      "total": 23.49,
      "electricity_usd_2026_kwh": 0.1409,
      "wacc": 0.0508,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.92,
      "electricity": 1.77,
      "site_grid": 1.47,
      "operations": 5.89,
      "total": 31.04,
      "electricity_usd_2026_kwh": 0.1409,
      "wacc": 0.0508,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.31,
      "electricity": 3.74,
      "site_grid": 3.02,
      "operations": 7.62,
      "total": 51.69,
      "electricity_usd_2026_kwh": 0.1409,
      "wacc": 0.0508,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.96,
      "electricity": 4.79,
      "site_grid": 3.15,
      "operations": 13.83,
      "total": 68.73,
      "electricity_usd_2026_kwh": 0.1409,
      "wacc": 0.0508,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.55,
      "electricity": 8.81,
      "site_grid": 6.69,
      "operations": 18.14,
      "total": 116.19,
      "electricity_usd_2026_kwh": 0.1409,
      "wacc": 0.0508,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.88,
      "electricity": 11.27,
      "site_grid": 6.97,
      "operations": 33.29,
      "total": 155.42,
      "electricity_usd_2026_kwh": 0.1409,
      "wacc": 0.0508,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.16,
      "electricity": 1.33,
      "site_grid": 1.39,
      "operations": 3.28,
      "total": 23.16,
      "electricity_usd_2026_kwh": 0.1355,
      "wacc": 0.0431,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.6,
      "electricity": 1.7,
      "site_grid": 1.46,
      "operations": 5.89,
      "total": 30.65,
      "electricity_usd_2026_kwh": 0.1355,
      "wacc": 0.0431,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.77,
      "electricity": 3.6,
      "site_grid": 2.98,
      "operations": 7.62,
      "total": 50.97,
      "electricity_usd_2026_kwh": 0.1355,
      "wacc": 0.0431,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.28,
      "electricity": 4.6,
      "site_grid": 3.14,
      "operations": 13.83,
      "total": 67.86,
      "electricity_usd_2026_kwh": 0.1355,
      "wacc": 0.0431,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.35,
      "electricity": 8.48,
      "site_grid": 6.59,
      "operations": 18.14,
      "total": 114.56,
      "electricity_usd_2026_kwh": 0.1355,
      "wacc": 0.0431,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.39,
      "electricity": 10.84,
      "site_grid": 6.94,
      "operations": 33.29,
      "total": 153.47,
      "electricity_usd_2026_kwh": 0.1355,
      "wacc": 0.0431,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.06,
      "electricity": 1.26,
      "site_grid": 1.38,
      "operations": 3.28,
      "total": 22.99,
      "electricity_usd_2026_kwh": 0.1288,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.27,
      "electricity": 1.61,
      "site_grid": 1.42,
      "operations": 5.89,
      "total": 30.19,
      "electricity_usd_2026_kwh": 0.1288,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.55,
      "electricity": 3.42,
      "site_grid": 2.96,
      "operations": 7.62,
      "total": 50.56,
      "electricity_usd_2026_kwh": 0.1288,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.57,
      "electricity": 4.38,
      "site_grid": 3.04,
      "operations": 13.83,
      "total": 66.83,
      "electricity_usd_2026_kwh": 0.1288,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.87,
      "electricity": 8.06,
      "site_grid": 6.55,
      "operations": 18.14,
      "total": 113.63,
      "electricity_usd_2026_kwh": 0.1288,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.83,
      "electricity": 10.31,
      "site_grid": 6.73,
      "operations": 33.29,
      "total": 151.16,
      "electricity_usd_2026_kwh": 0.1288,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.06,
      "electricity": 1.35,
      "site_grid": 1.39,
      "operations": 3.28,
      "total": 23.09,
      "electricity_usd_2026_kwh": 0.1382,
      "wacc": 0.0362,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.32,
      "electricity": 1.73,
      "site_grid": 1.44,
      "operations": 5.89,
      "total": 30.38,
      "electricity_usd_2026_kwh": 0.1382,
      "wacc": 0.0362,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.55,
      "electricity": 3.67,
      "site_grid": 2.98,
      "operations": 7.62,
      "total": 50.82,
      "electricity_usd_2026_kwh": 0.1382,
      "wacc": 0.0362,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.68,
      "electricity": 4.7,
      "site_grid": 3.08,
      "operations": 13.83,
      "total": 67.28,
      "electricity_usd_2026_kwh": 0.1382,
      "wacc": 0.0362,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.87,
      "electricity": 8.64,
      "site_grid": 6.58,
      "operations": 18.14,
      "total": 114.25,
      "electricity_usd_2026_kwh": 0.1382,
      "wacc": 0.0362,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.05,
      "electricity": 11.06,
      "site_grid": 6.81,
      "operations": 33.29,
      "total": 152.22,
      "electricity_usd_2026_kwh": 0.1382,
      "wacc": 0.0362,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.43,
      "electricity": 1.51,
      "site_grid": 1.7,
      "operations": 3.28,
      "total": 23.93,
      "electricity_usd_2026_kwh": 0.1543,
      "wacc": 0.0512,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.93,
      "electricity": 1.93,
      "site_grid": 1.77,
      "operations": 5.89,
      "total": 31.53,
      "electricity_usd_2026_kwh": 0.1543,
      "wacc": 0.0512,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.34,
      "electricity": 4.1,
      "site_grid": 3.65,
      "operations": 7.62,
      "total": 52.71,
      "electricity_usd_2026_kwh": 0.1543,
      "wacc": 0.0512,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.99,
      "electricity": 5.24,
      "site_grid": 3.8,
      "operations": 13.83,
      "total": 69.87,
      "electricity_usd_2026_kwh": 0.1543,
      "wacc": 0.0512,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.61,
      "electricity": 9.65,
      "site_grid": 8.07,
      "operations": 18.14,
      "total": 118.48,
      "electricity_usd_2026_kwh": 0.1543,
      "wacc": 0.0512,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.96,
      "electricity": 12.35,
      "site_grid": 8.41,
      "operations": 33.29,
      "total": 158.01,
      "electricity_usd_2026_kwh": 0.1543,
      "wacc": 0.0512,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.76,
      "electricity": 1.43,
      "site_grid": 1.89,
      "operations": 3.28,
      "total": 24.36,
      "electricity_usd_2026_kwh": 0.1462,
      "wacc": 0.0613,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.35,
      "electricity": 1.83,
      "site_grid": 1.94,
      "operations": 5.89,
      "total": 32.01,
      "electricity_usd_2026_kwh": 0.1462,
      "wacc": 0.0613,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.05,
      "electricity": 3.88,
      "site_grid": 4.04,
      "operations": 7.62,
      "total": 53.59,
      "electricity_usd_2026_kwh": 0.1462,
      "wacc": 0.0613,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.88,
      "electricity": 4.97,
      "site_grid": 4.15,
      "operations": 13.83,
      "total": 70.84,
      "electricity_usd_2026_kwh": 0.1462,
      "wacc": 0.0613,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.18,
      "electricity": 9.15,
      "site_grid": 8.94,
      "operations": 18.14,
      "total": 120.41,
      "electricity_usd_2026_kwh": 0.1462,
      "wacc": 0.0613,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.93,
      "electricity": 11.7,
      "site_grid": 9.19,
      "operations": 33.29,
      "total": 160.11,
      "electricity_usd_2026_kwh": 0.1462,
      "wacc": 0.0613,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.84,
      "electricity": 1.37,
      "site_grid": 1.86,
      "operations": 3.28,
      "total": 24.35,
      "electricity_usd_2026_kwh": 0.1395,
      "wacc": 0.0638,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.45,
      "electricity": 1.75,
      "site_grid": 1.9,
      "operations": 5.89,
      "total": 31.99,
      "electricity_usd_2026_kwh": 0.1395,
      "wacc": 0.0638,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.23,
      "electricity": 3.71,
      "site_grid": 3.98,
      "operations": 7.62,
      "total": 53.53,
      "electricity_usd_2026_kwh": 0.1395,
      "wacc": 0.0638,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.1,
      "electricity": 4.74,
      "site_grid": 4.08,
      "operations": 13.83,
      "total": 70.75,
      "electricity_usd_2026_kwh": 0.1395,
      "wacc": 0.0638,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.57,
      "electricity": 8.73,
      "site_grid": 8.8,
      "operations": 18.14,
      "total": 120.25,
      "electricity_usd_2026_kwh": 0.1395,
      "wacc": 0.0638,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.42,
      "electricity": 11.17,
      "site_grid": 9.02,
      "operations": 33.29,
      "total": 159.89,
      "electricity_usd_2026_kwh": 0.1395,
      "wacc": 0.0638,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.87,
      "electricity": 1.31,
      "site_grid": 1.84,
      "operations": 3.28,
      "total": 24.31,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.0646,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.49,
      "electricity": 1.68,
      "site_grid": 1.89,
      "operations": 5.89,
      "total": 31.94,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.0646,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.29,
      "electricity": 3.56,
      "site_grid": 3.95,
      "operations": 7.62,
      "total": 53.42,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.0646,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.18,
      "electricity": 4.56,
      "site_grid": 4.04,
      "operations": 13.83,
      "total": 70.61,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.0646,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.7,
      "electricity": 8.39,
      "site_grid": 8.74,
      "operations": 18.14,
      "total": 119.98,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.0646,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.58,
      "electricity": 10.74,
      "site_grid": 8.94,
      "operations": 33.29,
      "total": 159.56,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.0646,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.88,
      "electricity": 1.31,
      "site_grid": 1.85,
      "operations": 3.28,
      "total": 24.33,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.065,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.5,
      "electricity": 1.68,
      "site_grid": 1.9,
      "operations": 5.89,
      "total": 31.97,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.065,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.31,
      "electricity": 3.56,
      "site_grid": 3.97,
      "operations": 7.62,
      "total": 53.47,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.065,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.21,
      "electricity": 4.56,
      "site_grid": 4.06,
      "operations": 13.83,
      "total": 70.66,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.065,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.76,
      "electricity": 8.39,
      "site_grid": 8.78,
      "operations": 18.14,
      "total": 120.08,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.065,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.66,
      "electricity": 10.74,
      "site_grid": 8.99,
      "operations": 33.29,
      "total": 159.67,
      "electricity_usd_2026_kwh": 0.1342,
      "wacc": 0.065,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.33,
      "electricity": 2.17,
      "site_grid": 1.51,
      "operations": 3.44,
      "total": 24.45,
      "electricity_usd_2026_kwh": 0.2093,
      "wacc": 0.0488,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.77,
      "electricity": 2.77,
      "site_grid": 1.75,
      "operations": 6.52,
      "total": 32.82,
      "electricity_usd_2026_kwh": 0.2093,
      "wacc": 0.0488,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.13,
      "electricity": 5.89,
      "site_grid": 3.23,
      "operations": 7.95,
      "total": 54.2,
      "electricity_usd_2026_kwh": 0.2093,
      "wacc": 0.0488,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.64,
      "electricity": 7.51,
      "site_grid": 3.76,
      "operations": 15.18,
      "total": 73.1,
      "electricity_usd_2026_kwh": 0.2093,
      "wacc": 0.0488,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.14,
      "electricity": 13.87,
      "site_grid": 7.15,
      "operations": 18.87,
      "total": 122.04,
      "electricity_usd_2026_kwh": 0.2093,
      "wacc": 0.0488,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.19,
      "electricity": 17.69,
      "site_grid": 8.31,
      "operations": 36.28,
      "total": 165.47,
      "electricity_usd_2026_kwh": 0.2093,
      "wacc": 0.0488,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.19,
      "electricity": 2.25,
      "site_grid": 1.44,
      "operations": 3.44,
      "total": 24.32,
      "electricity_usd_2026_kwh": 0.217,
      "wacc": 0.0445,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.59,
      "electricity": 2.87,
      "site_grid": 1.69,
      "operations": 6.52,
      "total": 32.68,
      "electricity_usd_2026_kwh": 0.217,
      "wacc": 0.0445,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.83,
      "electricity": 6.11,
      "site_grid": 3.09,
      "operations": 7.95,
      "total": 53.98,
      "electricity_usd_2026_kwh": 0.217,
      "wacc": 0.0445,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.27,
      "electricity": 7.79,
      "site_grid": 3.61,
      "operations": 15.18,
      "total": 72.85,
      "electricity_usd_2026_kwh": 0.217,
      "wacc": 0.0445,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.47,
      "electricity": 14.39,
      "site_grid": 6.84,
      "operations": 18.87,
      "total": 121.58,
      "electricity_usd_2026_kwh": 0.217,
      "wacc": 0.0445,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.35,
      "electricity": 18.35,
      "site_grid": 8.0,
      "operations": 36.28,
      "total": 164.97,
      "electricity_usd_2026_kwh": 0.217,
      "wacc": 0.0445,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.04,
      "electricity": 2.27,
      "site_grid": 1.4,
      "operations": 3.44,
      "total": 24.16,
      "electricity_usd_2026_kwh": 0.219,
      "wacc": 0.035,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.21,
      "electricity": 2.9,
      "site_grid": 1.6,
      "operations": 6.52,
      "total": 32.23,
      "electricity_usd_2026_kwh": 0.219,
      "wacc": 0.035,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.51,
      "electricity": 6.16,
      "site_grid": 3.01,
      "operations": 7.95,
      "total": 53.63,
      "electricity_usd_2026_kwh": 0.219,
      "wacc": 0.035,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.44,
      "electricity": 7.86,
      "site_grid": 3.44,
      "operations": 15.18,
      "total": 71.92,
      "electricity_usd_2026_kwh": 0.219,
      "wacc": 0.035,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.78,
      "electricity": 14.52,
      "site_grid": 6.66,
      "operations": 18.87,
      "total": 120.82,
      "electricity_usd_2026_kwh": 0.219,
      "wacc": 0.035,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.52,
      "electricity": 18.51,
      "site_grid": 7.61,
      "operations": 36.28,
      "total": 162.92,
      "electricity_usd_2026_kwh": 0.219,
      "wacc": 0.035,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.05,
      "electricity": 2.25,
      "site_grid": 1.42,
      "operations": 3.44,
      "total": 24.16,
      "electricity_usd_2026_kwh": 0.217,
      "wacc": 0.0402,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.42,
      "electricity": 2.87,
      "site_grid": 1.67,
      "operations": 6.52,
      "total": 32.48,
      "electricity_usd_2026_kwh": 0.217,
      "wacc": 0.0402,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.52,
      "electricity": 6.11,
      "site_grid": 3.04,
      "operations": 7.95,
      "total": 53.62,
      "electricity_usd_2026_kwh": 0.217,
      "wacc": 0.0402,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.89,
      "electricity": 7.79,
      "site_grid": 3.57,
      "operations": 15.18,
      "total": 72.44,
      "electricity_usd_2026_kwh": 0.217,
      "wacc": 0.0402,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.8,
      "electricity": 14.39,
      "site_grid": 6.72,
      "operations": 18.87,
      "total": 120.79,
      "electricity_usd_2026_kwh": 0.217,
      "wacc": 0.0402,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.52,
      "electricity": 18.35,
      "site_grid": 7.91,
      "operations": 36.28,
      "total": 164.05,
      "electricity_usd_2026_kwh": 0.217,
      "wacc": 0.0402,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.11,
      "electricity": 2.17,
      "site_grid": 1.46,
      "operations": 3.44,
      "total": 24.18,
      "electricity_usd_2026_kwh": 0.2093,
      "wacc": 0.0421,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.5,
      "electricity": 2.77,
      "site_grid": 1.71,
      "operations": 6.52,
      "total": 32.5,
      "electricity_usd_2026_kwh": 0.2093,
      "wacc": 0.0421,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.66,
      "electricity": 5.89,
      "site_grid": 3.13,
      "operations": 7.95,
      "total": 53.63,
      "electricity_usd_2026_kwh": 0.2093,
      "wacc": 0.0421,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.05,
      "electricity": 7.51,
      "site_grid": 3.67,
      "operations": 15.18,
      "total": 72.42,
      "electricity_usd_2026_kwh": 0.2093,
      "wacc": 0.0421,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.1,
      "electricity": 13.87,
      "site_grid": 6.92,
      "operations": 18.87,
      "total": 120.77,
      "electricity_usd_2026_kwh": 0.2093,
      "wacc": 0.0421,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.89,
      "electricity": 17.69,
      "site_grid": 8.12,
      "operations": 36.28,
      "total": 163.98,
      "electricity_usd_2026_kwh": 0.2093,
      "wacc": 0.0421,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.04,
      "electricity": 2.05,
      "site_grid": 1.46,
      "operations": 3.44,
      "total": 24.0,
      "electricity_usd_2026_kwh": 0.1977,
      "wacc": 0.0381,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.33,
      "electricity": 2.62,
      "site_grid": 1.7,
      "operations": 6.52,
      "total": 32.17,
      "electricity_usd_2026_kwh": 0.1977,
      "wacc": 0.0381,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.51,
      "electricity": 5.56,
      "site_grid": 3.14,
      "operations": 7.95,
      "total": 53.16,
      "electricity_usd_2026_kwh": 0.1977,
      "wacc": 0.0381,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.7,
      "electricity": 7.09,
      "site_grid": 3.65,
      "operations": 15.18,
      "total": 71.63,
      "electricity_usd_2026_kwh": 0.1977,
      "wacc": 0.0381,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.78,
      "electricity": 13.1,
      "site_grid": 6.94,
      "operations": 18.87,
      "total": 119.69,
      "electricity_usd_2026_kwh": 0.1977,
      "wacc": 0.0381,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.11,
      "electricity": 16.71,
      "site_grid": 8.08,
      "operations": 36.28,
      "total": 162.17,
      "electricity_usd_2026_kwh": 0.1977,
      "wacc": 0.0381,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.04,
      "electricity": 1.97,
      "site_grid": 1.46,
      "operations": 3.44,
      "total": 23.91,
      "electricity_usd_2026_kwh": 0.1899,
      "wacc": 0.0351,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.21,
      "electricity": 2.51,
      "site_grid": 1.66,
      "operations": 6.52,
      "total": 31.91,
      "electricity_usd_2026_kwh": 0.1899,
      "wacc": 0.0351,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.51,
      "electricity": 5.35,
      "site_grid": 3.12,
      "operations": 7.95,
      "total": 52.92,
      "electricity_usd_2026_kwh": 0.1899,
      "wacc": 0.0351,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.44,
      "electricity": 6.82,
      "site_grid": 3.56,
      "operations": 15.18,
      "total": 71.01,
      "electricity_usd_2026_kwh": 0.1899,
      "wacc": 0.0351,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.78,
      "electricity": 12.59,
      "site_grid": 6.9,
      "operations": 18.87,
      "total": 119.14,
      "electricity_usd_2026_kwh": 0.1899,
      "wacc": 0.0351,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.53,
      "electricity": 16.05,
      "site_grid": 7.89,
      "operations": 36.28,
      "total": 160.75,
      "electricity_usd_2026_kwh": 0.1899,
      "wacc": 0.0351,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.04,
      "electricity": 2.01,
      "site_grid": 1.46,
      "operations": 3.44,
      "total": 23.95,
      "electricity_usd_2026_kwh": 0.1938,
      "wacc": 0.04,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.41,
      "electricity": 2.57,
      "site_grid": 1.72,
      "operations": 6.52,
      "total": 32.22,
      "electricity_usd_2026_kwh": 0.1938,
      "wacc": 0.04,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.51,
      "electricity": 5.45,
      "site_grid": 3.13,
      "operations": 7.95,
      "total": 53.04,
      "electricity_usd_2026_kwh": 0.1938,
      "wacc": 0.04,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.87,
      "electricity": 6.95,
      "site_grid": 3.68,
      "operations": 15.18,
      "total": 71.69,
      "electricity_usd_2026_kwh": 0.1938,
      "wacc": 0.04,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.78,
      "electricity": 12.85,
      "site_grid": 6.93,
      "operations": 18.87,
      "total": 119.42,
      "electricity_usd_2026_kwh": 0.1938,
      "wacc": 0.04,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.48,
      "electricity": 16.38,
      "site_grid": 8.15,
      "operations": 36.28,
      "total": 162.28,
      "electricity_usd_2026_kwh": 0.1938,
      "wacc": 0.04,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.23,
      "electricity": 2.11,
      "site_grid": 1.56,
      "operations": 3.44,
      "total": 24.34,
      "electricity_usd_2026_kwh": 0.2035,
      "wacc": 0.0458,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.65,
      "electricity": 2.69,
      "site_grid": 1.82,
      "operations": 6.52,
      "total": 32.68,
      "electricity_usd_2026_kwh": 0.2035,
      "wacc": 0.0458,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.92,
      "electricity": 5.73,
      "site_grid": 3.34,
      "operations": 7.95,
      "total": 53.93,
      "electricity_usd_2026_kwh": 0.2035,
      "wacc": 0.0458,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.38,
      "electricity": 7.3,
      "site_grid": 3.89,
      "operations": 15.18,
      "total": 72.76,
      "electricity_usd_2026_kwh": 0.2035,
      "wacc": 0.0458,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.67,
      "electricity": 13.49,
      "site_grid": 7.38,
      "operations": 18.87,
      "total": 121.42,
      "electricity_usd_2026_kwh": 0.2035,
      "wacc": 0.0458,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.6,
      "electricity": 17.2,
      "site_grid": 8.61,
      "operations": 36.28,
      "total": 164.69,
      "electricity_usd_2026_kwh": 0.2035,
      "wacc": 0.0458,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.04,
      "electricity": 2.03,
      "site_grid": 1.55,
      "operations": 3.44,
      "total": 24.07,
      "electricity_usd_2026_kwh": 0.1957,
      "wacc": 0.0381,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.33,
      "electricity": 2.59,
      "site_grid": 1.81,
      "operations": 6.52,
      "total": 32.25,
      "electricity_usd_2026_kwh": 0.1957,
      "wacc": 0.0381,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.51,
      "electricity": 5.51,
      "site_grid": 3.33,
      "operations": 7.95,
      "total": 53.3,
      "electricity_usd_2026_kwh": 0.1957,
      "wacc": 0.0381,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.71,
      "electricity": 7.02,
      "site_grid": 3.87,
      "operations": 15.18,
      "total": 71.79,
      "electricity_usd_2026_kwh": 0.1957,
      "wacc": 0.0381,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.78,
      "electricity": 12.97,
      "site_grid": 7.37,
      "operations": 18.87,
      "total": 119.99,
      "electricity_usd_2026_kwh": 0.1957,
      "wacc": 0.0381,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 101.12,
      "electricity": 16.54,
      "site_grid": 8.57,
      "operations": 36.28,
      "total": 162.51,
      "electricity_usd_2026_kwh": 0.1957,
      "wacc": 0.0381,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.04,
      "electricity": 1.93,
      "site_grid": 1.58,
      "operations": 3.44,
      "total": 23.99,
      "electricity_usd_2026_kwh": 0.186,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.21,
      "electricity": 2.46,
      "site_grid": 1.81,
      "operations": 6.52,
      "total": 32.0,
      "electricity_usd_2026_kwh": 0.186,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.51,
      "electricity": 5.24,
      "site_grid": 3.39,
      "operations": 7.95,
      "total": 53.08,
      "electricity_usd_2026_kwh": 0.186,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.44,
      "electricity": 6.68,
      "site_grid": 3.87,
      "operations": 15.18,
      "total": 71.17,
      "electricity_usd_2026_kwh": 0.186,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.78,
      "electricity": 12.33,
      "site_grid": 7.49,
      "operations": 18.87,
      "total": 119.47,
      "electricity_usd_2026_kwh": 0.186,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.52,
      "electricity": 15.72,
      "site_grid": 8.56,
      "operations": 36.28,
      "total": 161.09,
      "electricity_usd_2026_kwh": 0.186,
      "wacc": 0.035,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.04,
      "electricity": 2.07,
      "site_grid": 1.59,
      "operations": 3.44,
      "total": 24.14,
      "electricity_usd_2026_kwh": 0.1996,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.21,
      "electricity": 2.64,
      "site_grid": 1.82,
      "operations": 6.52,
      "total": 32.19,
      "electricity_usd_2026_kwh": 0.1996,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.51,
      "electricity": 5.62,
      "site_grid": 3.4,
      "operations": 7.95,
      "total": 53.48,
      "electricity_usd_2026_kwh": 0.1996,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 45.44,
      "electricity": 7.16,
      "site_grid": 3.89,
      "operations": 15.18,
      "total": 71.68,
      "electricity_usd_2026_kwh": 0.1996,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 80.78,
      "electricity": 13.23,
      "site_grid": 7.53,
      "operations": 18.87,
      "total": 120.41,
      "electricity_usd_2026_kwh": 0.1996,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 100.52,
      "electricity": 16.87,
      "site_grid": 8.6,
      "operations": 36.28,
      "total": 162.28,
      "electricity_usd_2026_kwh": 0.1996,
      "wacc": 0.035,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.24,
      "electricity": 2.31,
      "site_grid": 1.88,
      "operations": 3.44,
      "total": 24.88,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.0462,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.66,
      "electricity": 2.95,
      "site_grid": 2.19,
      "operations": 6.52,
      "total": 33.33,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.0462,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 36.94,
      "electricity": 6.27,
      "site_grid": 4.03,
      "operations": 7.95,
      "total": 55.2,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.0462,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.41,
      "electricity": 8.0,
      "site_grid": 4.7,
      "operations": 15.18,
      "total": 74.3,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.0462,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 81.73,
      "electricity": 14.77,
      "site_grid": 8.92,
      "operations": 18.87,
      "total": 124.3,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.0462,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 102.68,
      "electricity": 18.84,
      "site_grid": 10.4,
      "operations": 36.28,
      "total": 168.19,
      "electricity_usd_2026_kwh": 0.2229,
      "wacc": 0.0462,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.57,
      "electricity": 2.19,
      "site_grid": 2.09,
      "operations": 3.44,
      "total": 25.29,
      "electricity_usd_2026_kwh": 0.2112,
      "wacc": 0.0563,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.07,
      "electricity": 2.8,
      "site_grid": 2.4,
      "operations": 6.52,
      "total": 33.79,
      "electricity_usd_2026_kwh": 0.2112,
      "wacc": 0.0563,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.65,
      "electricity": 5.95,
      "site_grid": 4.47,
      "operations": 7.95,
      "total": 56.02,
      "electricity_usd_2026_kwh": 0.2112,
      "wacc": 0.0563,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.3,
      "electricity": 7.58,
      "site_grid": 5.14,
      "operations": 15.18,
      "total": 75.2,
      "electricity_usd_2026_kwh": 0.2112,
      "wacc": 0.0563,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.3,
      "electricity": 14.0,
      "site_grid": 9.89,
      "operations": 18.87,
      "total": 126.07,
      "electricity_usd_2026_kwh": 0.2112,
      "wacc": 0.0563,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.64,
      "electricity": 17.85,
      "site_grid": 11.37,
      "operations": 36.28,
      "total": 170.13,
      "electricity_usd_2026_kwh": 0.2112,
      "wacc": 0.0563,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.66,
      "electricity": 2.09,
      "site_grid": 2.06,
      "operations": 3.44,
      "total": 25.24,
      "electricity_usd_2026_kwh": 0.2015,
      "wacc": 0.0588,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.18,
      "electricity": 2.67,
      "site_grid": 2.35,
      "operations": 6.52,
      "total": 33.72,
      "electricity_usd_2026_kwh": 0.2015,
      "wacc": 0.0588,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.83,
      "electricity": 5.67,
      "site_grid": 4.4,
      "operations": 7.95,
      "total": 55.85,
      "electricity_usd_2026_kwh": 0.2015,
      "wacc": 0.0588,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.52,
      "electricity": 7.23,
      "site_grid": 5.04,
      "operations": 15.18,
      "total": 74.98,
      "electricity_usd_2026_kwh": 0.2015,
      "wacc": 0.0588,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.69,
      "electricity": 13.36,
      "site_grid": 9.74,
      "operations": 18.87,
      "total": 125.66,
      "electricity_usd_2026_kwh": 0.2015,
      "wacc": 0.0588,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.12,
      "electricity": 17.03,
      "site_grid": 11.16,
      "operations": 36.28,
      "total": 169.59,
      "electricity_usd_2026_kwh": 0.2015,
      "wacc": 0.0588,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.68,
      "electricity": 2.01,
      "site_grid": 2.04,
      "operations": 3.44,
      "total": 25.17,
      "electricity_usd_2026_kwh": 0.1938,
      "wacc": 0.0596,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.21,
      "electricity": 2.57,
      "site_grid": 2.33,
      "operations": 6.52,
      "total": 33.63,
      "electricity_usd_2026_kwh": 0.1938,
      "wacc": 0.0596,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.89,
      "electricity": 5.45,
      "site_grid": 4.37,
      "operations": 7.95,
      "total": 55.66,
      "electricity_usd_2026_kwh": 0.1938,
      "wacc": 0.0596,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.59,
      "electricity": 6.95,
      "site_grid": 5.0,
      "operations": 15.18,
      "total": 74.73,
      "electricity_usd_2026_kwh": 0.1938,
      "wacc": 0.0596,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.82,
      "electricity": 12.85,
      "site_grid": 9.67,
      "operations": 18.87,
      "total": 125.21,
      "electricity_usd_2026_kwh": 0.1938,
      "wacc": 0.0596,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.29,
      "electricity": 16.38,
      "site_grid": 11.07,
      "operations": 36.28,
      "total": 169.01,
      "electricity_usd_2026_kwh": 0.1938,
      "wacc": 0.0596,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.7,
      "electricity": 2.01,
      "site_grid": 2.05,
      "operations": 3.44,
      "total": 25.2,
      "electricity_usd_2026_kwh": 0.1938,
      "wacc": 0.06,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.23,
      "electricity": 2.57,
      "site_grid": 2.35,
      "operations": 6.52,
      "total": 33.66,
      "electricity_usd_2026_kwh": 0.1938,
      "wacc": 0.06,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.91,
      "electricity": 5.45,
      "site_grid": 4.39,
      "operations": 7.95,
      "total": 55.71,
      "electricity_usd_2026_kwh": 0.1938,
      "wacc": 0.06,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.62,
      "electricity": 6.95,
      "site_grid": 5.03,
      "operations": 15.18,
      "total": 74.79,
      "electricity_usd_2026_kwh": 0.1938,
      "wacc": 0.06,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.88,
      "electricity": 12.85,
      "site_grid": 9.72,
      "operations": 18.87,
      "total": 125.32,
      "electricity_usd_2026_kwh": 0.1938,
      "wacc": 0.06,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.36,
      "electricity": 16.38,
      "site_grid": 11.12,
      "operations": 36.28,
      "total": 169.13,
      "electricity_usd_2026_kwh": 0.1938,
      "wacc": 0.06,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.52,
      "electricity": 1.46,
      "site_grid": 1.52,
      "operations": 3.45,
      "total": 24.95,
      "electricity_usd_2026_kwh": 0.1499,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.31,
      "electricity": 1.86,
      "site_grid": 1.5,
      "operations": 6.55,
      "total": 33.22,
      "electricity_usd_2026_kwh": 0.1499,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.69,
      "electricity": 3.95,
      "site_grid": 3.25,
      "operations": 7.98,
      "total": 54.87,
      "electricity_usd_2026_kwh": 0.1499,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.94,
      "electricity": 5.05,
      "site_grid": 3.21,
      "operations": 15.25,
      "total": 73.44,
      "electricity_usd_2026_kwh": 0.1499,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.81,
      "electricity": 9.29,
      "site_grid": 7.2,
      "operations": 18.94,
      "total": 123.24,
      "electricity_usd_2026_kwh": 0.1499,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.48,
      "electricity": 11.89,
      "site_grid": 7.09,
      "operations": 36.43,
      "total": 165.89,
      "electricity_usd_2026_kwh": 0.1499,
      "wacc": 0.0688,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.38,
      "electricity": 1.51,
      "site_grid": 1.46,
      "operations": 3.45,
      "total": 24.79,
      "electricity_usd_2026_kwh": 0.1554,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.12,
      "electricity": 1.93,
      "site_grid": 1.44,
      "operations": 6.55,
      "total": 33.05,
      "electricity_usd_2026_kwh": 0.1554,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.37,
      "electricity": 4.09,
      "site_grid": 3.12,
      "operations": 7.98,
      "total": 54.56,
      "electricity_usd_2026_kwh": 0.1554,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.54,
      "electricity": 5.24,
      "site_grid": 3.09,
      "operations": 15.25,
      "total": 73.12,
      "electricity_usd_2026_kwh": 0.1554,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.11,
      "electricity": 9.64,
      "site_grid": 6.9,
      "operations": 18.94,
      "total": 122.59,
      "electricity_usd_2026_kwh": 0.1554,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.61,
      "electricity": 12.33,
      "site_grid": 6.84,
      "operations": 36.43,
      "total": 165.2,
      "electricity_usd_2026_kwh": 0.1554,
      "wacc": 0.0645,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.04,
      "electricity": 1.52,
      "site_grid": 1.37,
      "operations": 3.45,
      "total": 24.39,
      "electricity_usd_2026_kwh": 0.1568,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.71,
      "electricity": 1.95,
      "site_grid": 1.37,
      "operations": 6.55,
      "total": 32.58,
      "electricity_usd_2026_kwh": 0.1568,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.66,
      "electricity": 4.13,
      "site_grid": 2.93,
      "operations": 7.98,
      "total": 53.7,
      "electricity_usd_2026_kwh": 0.1568,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.65,
      "electricity": 5.28,
      "site_grid": 2.94,
      "operations": 15.25,
      "total": 72.13,
      "electricity_usd_2026_kwh": 0.1568,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.53,
      "electricity": 9.72,
      "site_grid": 6.49,
      "operations": 18.94,
      "total": 120.69,
      "electricity_usd_2026_kwh": 0.1568,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.64,
      "electricity": 12.44,
      "site_grid": 6.51,
      "operations": 36.43,
      "total": 163.02,
      "electricity_usd_2026_kwh": 0.1568,
      "wacc": 0.0547,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.23,
      "electricity": 1.51,
      "site_grid": 1.43,
      "operations": 3.45,
      "total": 24.63,
      "electricity_usd_2026_kwh": 0.1554,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.94,
      "electricity": 1.93,
      "site_grid": 1.43,
      "operations": 6.55,
      "total": 32.85,
      "electricity_usd_2026_kwh": 0.1554,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.06,
      "electricity": 4.09,
      "site_grid": 3.07,
      "operations": 7.98,
      "total": 54.2,
      "electricity_usd_2026_kwh": 0.1554,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.15,
      "electricity": 5.24,
      "site_grid": 3.06,
      "operations": 15.25,
      "total": 72.69,
      "electricity_usd_2026_kwh": 0.1554,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.41,
      "electricity": 9.64,
      "site_grid": 6.79,
      "operations": 18.94,
      "total": 121.79,
      "electricity_usd_2026_kwh": 0.1554,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.74,
      "electricity": 12.33,
      "site_grid": 6.77,
      "operations": 36.43,
      "total": 164.26,
      "electricity_usd_2026_kwh": 0.1554,
      "wacc": 0.0602,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.29,
      "electricity": 1.46,
      "site_grid": 1.47,
      "operations": 3.45,
      "total": 24.68,
      "electricity_usd_2026_kwh": 0.1499,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.02,
      "electricity": 1.86,
      "site_grid": 1.47,
      "operations": 6.55,
      "total": 32.9,
      "electricity_usd_2026_kwh": 0.1499,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.2,
      "electricity": 3.95,
      "site_grid": 3.16,
      "operations": 7.98,
      "total": 54.28,
      "electricity_usd_2026_kwh": 0.1499,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.32,
      "electricity": 5.05,
      "site_grid": 3.14,
      "operations": 15.25,
      "total": 72.76,
      "electricity_usd_2026_kwh": 0.1499,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.72,
      "electricity": 9.29,
      "site_grid": 6.99,
      "operations": 18.94,
      "total": 121.94,
      "electricity_usd_2026_kwh": 0.1499,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.12,
      "electricity": 11.89,
      "site_grid": 6.95,
      "operations": 36.43,
      "total": 164.38,
      "electricity_usd_2026_kwh": 0.1499,
      "wacc": 0.0621,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.16,
      "electricity": 1.37,
      "site_grid": 1.46,
      "operations": 3.45,
      "total": 24.45,
      "electricity_usd_2026_kwh": 0.1415,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.85,
      "electricity": 1.76,
      "site_grid": 1.46,
      "operations": 6.55,
      "total": 32.62,
      "electricity_usd_2026_kwh": 0.1415,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.9,
      "electricity": 3.73,
      "site_grid": 3.13,
      "operations": 7.98,
      "total": 53.74,
      "electricity_usd_2026_kwh": 0.1415,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.96,
      "electricity": 4.77,
      "site_grid": 3.13,
      "operations": 15.25,
      "total": 72.1,
      "electricity_usd_2026_kwh": 0.1415,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.07,
      "electricity": 8.78,
      "site_grid": 6.93,
      "operations": 18.94,
      "total": 120.72,
      "electricity_usd_2026_kwh": 0.1415,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.31,
      "electricity": 11.23,
      "site_grid": 6.92,
      "operations": 36.43,
      "total": 162.89,
      "electricity_usd_2026_kwh": 0.1415,
      "wacc": 0.0581,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.06,
      "electricity": 1.32,
      "site_grid": 1.42,
      "operations": 3.45,
      "total": 24.25,
      "electricity_usd_2026_kwh": 0.136,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.72,
      "electricity": 1.69,
      "site_grid": 1.43,
      "operations": 6.55,
      "total": 32.39,
      "electricity_usd_2026_kwh": 0.136,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.69,
      "electricity": 3.58,
      "site_grid": 3.05,
      "operations": 7.98,
      "total": 53.29,
      "electricity_usd_2026_kwh": 0.136,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.68,
      "electricity": 4.58,
      "site_grid": 3.06,
      "operations": 15.25,
      "total": 71.57,
      "electricity_usd_2026_kwh": 0.136,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.59,
      "electricity": 8.43,
      "site_grid": 6.74,
      "operations": 18.94,
      "total": 119.71,
      "electricity_usd_2026_kwh": 0.136,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.71,
      "electricity": 10.79,
      "site_grid": 6.76,
      "operations": 36.43,
      "total": 161.68,
      "electricity_usd_2026_kwh": 0.136,
      "wacc": 0.0551,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.22,
      "electricity": 1.35,
      "site_grid": 1.48,
      "operations": 3.45,
      "total": 24.5,
      "electricity_usd_2026_kwh": 0.1388,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.93,
      "electricity": 1.72,
      "site_grid": 1.47,
      "operations": 6.55,
      "total": 32.68,
      "electricity_usd_2026_kwh": 0.1388,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.04,
      "electricity": 3.65,
      "site_grid": 3.16,
      "operations": 7.98,
      "total": 53.84,
      "electricity_usd_2026_kwh": 0.1388,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.13,
      "electricity": 4.67,
      "site_grid": 3.15,
      "operations": 15.25,
      "total": 72.21,
      "electricity_usd_2026_kwh": 0.1388,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.38,
      "electricity": 8.6,
      "site_grid": 7.0,
      "operations": 18.94,
      "total": 120.92,
      "electricity_usd_2026_kwh": 0.1388,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.69,
      "electricity": 11.01,
      "site_grid": 6.98,
      "operations": 36.43,
      "total": 163.11,
      "electricity_usd_2026_kwh": 0.1388,
      "wacc": 0.06,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.42,
      "electricity": 1.42,
      "site_grid": 1.57,
      "operations": 3.45,
      "total": 24.86,
      "electricity_usd_2026_kwh": 0.1457,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.18,
      "electricity": 1.81,
      "site_grid": 1.55,
      "operations": 6.55,
      "total": 33.09,
      "electricity_usd_2026_kwh": 0.1457,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.47,
      "electricity": 3.84,
      "site_grid": 3.36,
      "operations": 7.98,
      "total": 54.65,
      "electricity_usd_2026_kwh": 0.1457,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.66,
      "electricity": 4.91,
      "site_grid": 3.33,
      "operations": 15.25,
      "total": 73.15,
      "electricity_usd_2026_kwh": 0.1457,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.32,
      "electricity": 9.03,
      "site_grid": 7.44,
      "operations": 18.94,
      "total": 122.73,
      "electricity_usd_2026_kwh": 0.1457,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.87,
      "electricity": 11.56,
      "site_grid": 7.36,
      "operations": 36.43,
      "total": 165.21,
      "electricity_usd_2026_kwh": 0.1457,
      "wacc": 0.0658,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.16,
      "electricity": 1.36,
      "site_grid": 1.55,
      "operations": 3.45,
      "total": 24.52,
      "electricity_usd_2026_kwh": 0.1401,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.85,
      "electricity": 1.74,
      "site_grid": 1.55,
      "operations": 6.55,
      "total": 32.69,
      "electricity_usd_2026_kwh": 0.1401,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.91,
      "electricity": 3.69,
      "site_grid": 3.32,
      "operations": 7.98,
      "total": 53.9,
      "electricity_usd_2026_kwh": 0.1401,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.96,
      "electricity": 4.72,
      "site_grid": 3.32,
      "operations": 15.25,
      "total": 72.25,
      "electricity_usd_2026_kwh": 0.1401,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.08,
      "electricity": 8.69,
      "site_grid": 7.35,
      "operations": 18.94,
      "total": 121.06,
      "electricity_usd_2026_kwh": 0.1401,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.32,
      "electricity": 11.12,
      "site_grid": 7.34,
      "operations": 36.43,
      "total": 163.21,
      "electricity_usd_2026_kwh": 0.1401,
      "wacc": 0.0581,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.74,
      "electricity": 1.29,
      "site_grid": 1.45,
      "operations": 3.45,
      "total": 23.93,
      "electricity_usd_2026_kwh": 0.1332,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.32,
      "electricity": 1.66,
      "site_grid": 1.47,
      "operations": 6.55,
      "total": 32.0,
      "electricity_usd_2026_kwh": 0.1332,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.0,
      "electricity": 3.51,
      "site_grid": 3.1,
      "operations": 7.98,
      "total": 52.59,
      "electricity_usd_2026_kwh": 0.1332,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.83,
      "electricity": 4.49,
      "site_grid": 3.15,
      "operations": 15.25,
      "total": 70.71,
      "electricity_usd_2026_kwh": 0.1332,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.07,
      "electricity": 8.26,
      "site_grid": 6.85,
      "operations": 18.94,
      "total": 118.13,
      "electricity_usd_2026_kwh": 0.1332,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.81,
      "electricity": 10.57,
      "site_grid": 6.96,
      "operations": 36.43,
      "total": 159.77,
      "electricity_usd_2026_kwh": 0.1332,
      "wacc": 0.0456,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.92,
      "electricity": 1.39,
      "site_grid": 1.51,
      "operations": 3.45,
      "total": 24.28,
      "electricity_usd_2026_kwh": 0.1429,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.56,
      "electricity": 1.78,
      "site_grid": 1.52,
      "operations": 6.55,
      "total": 32.41,
      "electricity_usd_2026_kwh": 0.1429,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.4,
      "electricity": 3.76,
      "site_grid": 3.24,
      "operations": 7.98,
      "total": 53.38,
      "electricity_usd_2026_kwh": 0.1429,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.33,
      "electricity": 4.82,
      "site_grid": 3.26,
      "operations": 15.25,
      "total": 71.66,
      "electricity_usd_2026_kwh": 0.1429,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.96,
      "electricity": 8.86,
      "site_grid": 7.16,
      "operations": 18.94,
      "total": 119.93,
      "electricity_usd_2026_kwh": 0.1429,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.92,
      "electricity": 11.34,
      "site_grid": 7.22,
      "operations": 36.43,
      "total": 161.91,
      "electricity_usd_2026_kwh": 0.1429,
      "wacc": 0.0512,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.43,
      "electricity": 1.55,
      "site_grid": 1.9,
      "operations": 3.45,
      "total": 25.33,
      "electricity_usd_2026_kwh": 0.1596,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.2,
      "electricity": 1.98,
      "site_grid": 1.87,
      "operations": 6.55,
      "total": 33.6,
      "electricity_usd_2026_kwh": 0.1596,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.5,
      "electricity": 4.2,
      "site_grid": 4.06,
      "operations": 7.98,
      "total": 55.74,
      "electricity_usd_2026_kwh": 0.1596,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.7,
      "electricity": 5.38,
      "site_grid": 4.02,
      "operations": 15.25,
      "total": 74.34,
      "electricity_usd_2026_kwh": 0.1596,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.38,
      "electricity": 9.9,
      "site_grid": 8.98,
      "operations": 18.94,
      "total": 125.2,
      "electricity_usd_2026_kwh": 0.1596,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.95,
      "electricity": 12.66,
      "site_grid": 8.88,
      "operations": 36.43,
      "total": 167.92,
      "electricity_usd_2026_kwh": 0.1596,
      "wacc": 0.0662,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.78,
      "electricity": 1.47,
      "site_grid": 2.09,
      "operations": 3.45,
      "total": 25.79,
      "electricity_usd_2026_kwh": 0.1512,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.63,
      "electricity": 1.88,
      "site_grid": 2.04,
      "operations": 6.55,
      "total": 34.1,
      "electricity_usd_2026_kwh": 0.1512,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.23,
      "electricity": 3.98,
      "site_grid": 4.48,
      "operations": 7.98,
      "total": 56.68,
      "electricity_usd_2026_kwh": 0.1512,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.62,
      "electricity": 5.1,
      "site_grid": 4.38,
      "operations": 15.25,
      "total": 75.34,
      "electricity_usd_2026_kwh": 0.1512,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.01,
      "electricity": 9.38,
      "site_grid": 9.91,
      "operations": 18.94,
      "total": 127.24,
      "electricity_usd_2026_kwh": 0.1512,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.99,
      "electricity": 12.0,
      "site_grid": 9.68,
      "operations": 36.43,
      "total": 170.1,
      "electricity_usd_2026_kwh": 0.1512,
      "wacc": 0.0763,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.86,
      "electricity": 1.4,
      "site_grid": 2.06,
      "operations": 3.45,
      "total": 25.77,
      "electricity_usd_2026_kwh": 0.1443,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.73,
      "electricity": 1.79,
      "site_grid": 2.0,
      "operations": 6.55,
      "total": 34.08,
      "electricity_usd_2026_kwh": 0.1443,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.42,
      "electricity": 3.8,
      "site_grid": 4.41,
      "operations": 7.98,
      "total": 56.6,
      "electricity_usd_2026_kwh": 0.1443,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.85,
      "electricity": 4.86,
      "site_grid": 4.29,
      "operations": 15.25,
      "total": 75.25,
      "electricity_usd_2026_kwh": 0.1443,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.42,
      "electricity": 8.95,
      "site_grid": 9.75,
      "operations": 18.94,
      "total": 127.06,
      "electricity_usd_2026_kwh": 0.1443,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.49,
      "electricity": 11.45,
      "site_grid": 9.5,
      "operations": 36.43,
      "total": 169.87,
      "electricity_usd_2026_kwh": 0.1443,
      "wacc": 0.0788,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.89,
      "electricity": 1.35,
      "site_grid": 2.04,
      "operations": 3.45,
      "total": 25.73,
      "electricity_usd_2026_kwh": 0.1388,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.77,
      "electricity": 1.72,
      "site_grid": 1.99,
      "operations": 6.55,
      "total": 34.03,
      "electricity_usd_2026_kwh": 0.1388,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.48,
      "electricity": 3.65,
      "site_grid": 4.37,
      "operations": 7.98,
      "total": 56.49,
      "electricity_usd_2026_kwh": 0.1388,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.93,
      "electricity": 4.67,
      "site_grid": 4.26,
      "operations": 15.25,
      "total": 75.11,
      "electricity_usd_2026_kwh": 0.1388,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.55,
      "electricity": 8.6,
      "site_grid": 9.67,
      "operations": 18.94,
      "total": 126.78,
      "electricity_usd_2026_kwh": 0.1388,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.67,
      "electricity": 11.01,
      "site_grid": 9.42,
      "operations": 36.43,
      "total": 169.52,
      "electricity_usd_2026_kwh": 0.1388,
      "wacc": 0.0796,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.91,
      "electricity": 1.35,
      "site_grid": 2.05,
      "operations": 3.45,
      "total": 25.76,
      "electricity_usd_2026_kwh": 0.1388,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.79,
      "electricity": 1.72,
      "site_grid": 2.0,
      "operations": 6.55,
      "total": 34.06,
      "electricity_usd_2026_kwh": 0.1388,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.51,
      "electricity": 3.65,
      "site_grid": 4.39,
      "operations": 7.98,
      "total": 56.54,
      "electricity_usd_2026_kwh": 0.1388,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.96,
      "electricity": 4.67,
      "site_grid": 4.28,
      "operations": 15.25,
      "total": 75.16,
      "electricity_usd_2026_kwh": 0.1388,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.62,
      "electricity": 8.6,
      "site_grid": 9.72,
      "operations": 18.94,
      "total": 126.89,
      "electricity_usd_2026_kwh": 0.1388,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.74,
      "electricity": 11.01,
      "site_grid": 9.46,
      "operations": 36.43,
      "total": 169.64,
      "electricity_usd_2026_kwh": 0.1388,
      "wacc": 0.08,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 23.96,
      "electricity": 1.6,
      "site_grid": 1.97,
      "operations": 3.69,
      "total": 31.22,
      "electricity_usd_2026_kwh": 0.1573,
      "wacc": 0.1288,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 30.35,
      "electricity": 2.06,
      "site_grid": 1.77,
      "operations": 5.9,
      "total": 40.09,
      "electricity_usd_2026_kwh": 0.1573,
      "wacc": 0.1288,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 51.34,
      "electricity": 4.34,
      "site_grid": 4.21,
      "operations": 8.48,
      "total": 68.38,
      "electricity_usd_2026_kwh": 0.1573,
      "wacc": 0.1288,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 65.04,
      "electricity": 5.59,
      "site_grid": 3.78,
      "operations": 13.88,
      "total": 88.29,
      "electricity_usd_2026_kwh": 0.1573,
      "wacc": 0.1288,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 113.59,
      "electricity": 10.23,
      "site_grid": 9.32,
      "operations": 20.06,
      "total": 153.2,
      "electricity_usd_2026_kwh": 0.1573,
      "wacc": 0.1288,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 143.88,
      "electricity": 13.17,
      "site_grid": 8.37,
      "operations": 33.43,
      "total": 198.85,
      "electricity_usd_2026_kwh": 0.1573,
      "wacc": 0.1288,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 23.79,
      "electricity": 1.63,
      "site_grid": 1.89,
      "operations": 3.69,
      "total": 31.0,
      "electricity_usd_2026_kwh": 0.1602,
      "wacc": 0.1245,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 30.13,
      "electricity": 2.1,
      "site_grid": 1.71,
      "operations": 5.9,
      "total": 39.84,
      "electricity_usd_2026_kwh": 0.1602,
      "wacc": 0.1245,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 50.96,
      "electricity": 4.42,
      "site_grid": 4.06,
      "operations": 8.48,
      "total": 67.93,
      "electricity_usd_2026_kwh": 0.1602,
      "wacc": 0.1245,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 64.56,
      "electricity": 5.7,
      "site_grid": 3.66,
      "operations": 13.88,
      "total": 87.79,
      "electricity_usd_2026_kwh": 0.1602,
      "wacc": 0.1245,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 112.75,
      "electricity": 10.42,
      "site_grid": 8.98,
      "operations": 20.06,
      "total": 152.21,
      "electricity_usd_2026_kwh": 0.1602,
      "wacc": 0.1245,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 142.82,
      "electricity": 13.42,
      "site_grid": 8.1,
      "operations": 33.43,
      "total": 197.77,
      "electricity_usd_2026_kwh": 0.1602,
      "wacc": 0.1245,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 23.39,
      "electricity": 1.65,
      "site_grid": 1.8,
      "operations": 3.69,
      "total": 30.52,
      "electricity_usd_2026_kwh": 0.1616,
      "wacc": 0.1147,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 29.63,
      "electricity": 2.12,
      "site_grid": 1.64,
      "operations": 5.9,
      "total": 39.29,
      "electricity_usd_2026_kwh": 0.1616,
      "wacc": 0.1147,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 50.11,
      "electricity": 4.46,
      "site_grid": 3.87,
      "operations": 8.48,
      "total": 66.92,
      "electricity_usd_2026_kwh": 0.1616,
      "wacc": 0.1147,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 63.48,
      "electricity": 5.75,
      "site_grid": 3.52,
      "operations": 13.88,
      "total": 86.62,
      "electricity_usd_2026_kwh": 0.1616,
      "wacc": 0.1147,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 110.86,
      "electricity": 10.51,
      "site_grid": 8.55,
      "operations": 20.06,
      "total": 149.99,
      "electricity_usd_2026_kwh": 0.1616,
      "wacc": 0.1147,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 140.44,
      "electricity": 13.54,
      "site_grid": 7.78,
      "operations": 33.43,
      "total": 195.18,
      "electricity_usd_2026_kwh": 0.1616,
      "wacc": 0.1147,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 23.61,
      "electricity": 1.63,
      "site_grid": 1.88,
      "operations": 3.69,
      "total": 30.8,
      "electricity_usd_2026_kwh": 0.1602,
      "wacc": 0.1202,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 29.91,
      "electricity": 2.1,
      "site_grid": 1.7,
      "operations": 5.9,
      "total": 39.61,
      "electricity_usd_2026_kwh": 0.1602,
      "wacc": 0.1202,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 50.59,
      "electricity": 4.42,
      "site_grid": 4.02,
      "operations": 8.48,
      "total": 67.51,
      "electricity_usd_2026_kwh": 0.1602,
      "wacc": 0.1202,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 64.08,
      "electricity": 5.7,
      "site_grid": 3.64,
      "operations": 13.88,
      "total": 87.29,
      "electricity_usd_2026_kwh": 0.1602,
      "wacc": 0.1202,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 111.91,
      "electricity": 10.42,
      "site_grid": 8.89,
      "operations": 20.06,
      "total": 151.29,
      "electricity_usd_2026_kwh": 0.1602,
      "wacc": 0.1202,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 141.77,
      "electricity": 13.42,
      "site_grid": 8.05,
      "operations": 33.43,
      "total": 196.66,
      "electricity_usd_2026_kwh": 0.1602,
      "wacc": 0.1202,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 23.69,
      "electricity": 1.59,
      "site_grid": 1.92,
      "operations": 3.69,
      "total": 30.89,
      "electricity_usd_2026_kwh": 0.1558,
      "wacc": 0.1221,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 30.01,
      "electricity": 2.04,
      "site_grid": 1.74,
      "operations": 5.9,
      "total": 39.69,
      "electricity_usd_2026_kwh": 0.1558,
      "wacc": 0.1221,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 50.75,
      "electricity": 4.3,
      "site_grid": 4.12,
      "operations": 8.48,
      "total": 67.66,
      "electricity_usd_2026_kwh": 0.1558,
      "wacc": 0.1221,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 64.29,
      "electricity": 5.54,
      "site_grid": 3.73,
      "operations": 13.88,
      "total": 87.44,
      "electricity_usd_2026_kwh": 0.1558,
      "wacc": 0.1221,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 112.28,
      "electricity": 10.14,
      "site_grid": 9.12,
      "operations": 20.06,
      "total": 151.61,
      "electricity_usd_2026_kwh": 0.1558,
      "wacc": 0.1221,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 142.23,
      "electricity": 13.05,
      "site_grid": 8.25,
      "operations": 33.43,
      "total": 196.96,
      "electricity_usd_2026_kwh": 0.1558,
      "wacc": 0.1221,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 23.52,
      "electricity": 1.53,
      "site_grid": 1.92,
      "operations": 3.69,
      "total": 30.66,
      "electricity_usd_2026_kwh": 0.15,
      "wacc": 0.1181,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 29.8,
      "electricity": 1.97,
      "site_grid": 1.74,
      "operations": 5.9,
      "total": 39.41,
      "electricity_usd_2026_kwh": 0.15,
      "wacc": 0.1181,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 50.4,
      "electricity": 4.14,
      "site_grid": 4.11,
      "operations": 8.48,
      "total": 67.13,
      "electricity_usd_2026_kwh": 0.15,
      "wacc": 0.1181,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 63.85,
      "electricity": 5.33,
      "site_grid": 3.73,
      "operations": 13.88,
      "total": 86.79,
      "electricity_usd_2026_kwh": 0.15,
      "wacc": 0.1181,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 111.5,
      "electricity": 9.76,
      "site_grid": 9.09,
      "operations": 20.06,
      "total": 150.41,
      "electricity_usd_2026_kwh": 0.15,
      "wacc": 0.1181,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 141.25,
      "electricity": 12.56,
      "site_grid": 8.24,
      "operations": 33.43,
      "total": 195.49,
      "electricity_usd_2026_kwh": 0.15,
      "wacc": 0.1181,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 23.4,
      "electricity": 1.48,
      "site_grid": 1.87,
      "operations": 3.69,
      "total": 30.44,
      "electricity_usd_2026_kwh": 0.1456,
      "wacc": 0.1151,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 29.65,
      "electricity": 1.91,
      "site_grid": 1.7,
      "operations": 5.9,
      "total": 39.16,
      "electricity_usd_2026_kwh": 0.1456,
      "wacc": 0.1151,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 50.14,
      "electricity": 4.02,
      "site_grid": 4.01,
      "operations": 8.48,
      "total": 66.66,
      "electricity_usd_2026_kwh": 0.1456,
      "wacc": 0.1151,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 63.52,
      "electricity": 5.18,
      "site_grid": 3.65,
      "operations": 13.88,
      "total": 86.22,
      "electricity_usd_2026_kwh": 0.1456,
      "wacc": 0.1151,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 110.92,
      "electricity": 9.47,
      "site_grid": 8.88,
      "operations": 20.06,
      "total": 149.34,
      "electricity_usd_2026_kwh": 0.1456,
      "wacc": 0.1151,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 140.52,
      "electricity": 12.2,
      "site_grid": 8.08,
      "operations": 33.43,
      "total": 194.22,
      "electricity_usd_2026_kwh": 0.1456,
      "wacc": 0.1151,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 23.6,
      "electricity": 1.5,
      "site_grid": 1.93,
      "operations": 3.69,
      "total": 30.72,
      "electricity_usd_2026_kwh": 0.1471,
      "wacc": 0.12,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 29.9,
      "electricity": 1.93,
      "site_grid": 1.75,
      "operations": 5.9,
      "total": 39.48,
      "electricity_usd_2026_kwh": 0.1471,
      "wacc": 0.12,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 50.57,
      "electricity": 4.06,
      "site_grid": 4.14,
      "operations": 8.48,
      "total": 67.25,
      "electricity_usd_2026_kwh": 0.1471,
      "wacc": 0.12,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 64.06,
      "electricity": 5.23,
      "site_grid": 3.75,
      "operations": 13.88,
      "total": 86.92,
      "electricity_usd_2026_kwh": 0.1471,
      "wacc": 0.12,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 111.87,
      "electricity": 9.57,
      "site_grid": 9.16,
      "operations": 20.06,
      "total": 150.66,
      "electricity_usd_2026_kwh": 0.1471,
      "wacc": 0.12,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 141.72,
      "electricity": 12.32,
      "site_grid": 8.29,
      "operations": 33.43,
      "total": 195.76,
      "electricity_usd_2026_kwh": 0.1471,
      "wacc": 0.12,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 23.84,
      "electricity": 1.54,
      "site_grid": 2.04,
      "operations": 3.69,
      "total": 31.11,
      "electricity_usd_2026_kwh": 0.1515,
      "wacc": 0.1258,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 30.2,
      "electricity": 1.99,
      "site_grid": 1.84,
      "operations": 5.9,
      "total": 39.93,
      "electricity_usd_2026_kwh": 0.1515,
      "wacc": 0.1258,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 51.08,
      "electricity": 4.18,
      "site_grid": 4.37,
      "operations": 8.48,
      "total": 68.11,
      "electricity_usd_2026_kwh": 0.1515,
      "wacc": 0.1258,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 64.7,
      "electricity": 5.39,
      "site_grid": 3.94,
      "operations": 13.88,
      "total": 87.9,
      "electricity_usd_2026_kwh": 0.1515,
      "wacc": 0.1258,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 113.0,
      "electricity": 9.85,
      "site_grid": 9.67,
      "operations": 20.06,
      "total": 152.58,
      "electricity_usd_2026_kwh": 0.1515,
      "wacc": 0.1258,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 143.14,
      "electricity": 12.68,
      "site_grid": 8.71,
      "operations": 33.43,
      "total": 197.96,
      "electricity_usd_2026_kwh": 0.1515,
      "wacc": 0.1258,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 23.53,
      "electricity": 1.51,
      "site_grid": 2.03,
      "operations": 3.69,
      "total": 30.76,
      "electricity_usd_2026_kwh": 0.1485,
      "wacc": 0.1181,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 29.8,
      "electricity": 1.95,
      "site_grid": 1.85,
      "operations": 5.9,
      "total": 39.5,
      "electricity_usd_2026_kwh": 0.1485,
      "wacc": 0.1181,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 50.4,
      "electricity": 4.1,
      "site_grid": 4.36,
      "operations": 8.48,
      "total": 67.35,
      "electricity_usd_2026_kwh": 0.1485,
      "wacc": 0.1181,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 63.85,
      "electricity": 5.28,
      "site_grid": 3.95,
      "operations": 13.88,
      "total": 86.97,
      "electricity_usd_2026_kwh": 0.1485,
      "wacc": 0.1181,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 111.51,
      "electricity": 9.66,
      "site_grid": 9.64,
      "operations": 20.06,
      "total": 150.88,
      "electricity_usd_2026_kwh": 0.1485,
      "wacc": 0.1181,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 141.26,
      "electricity": 12.44,
      "site_grid": 8.75,
      "operations": 33.43,
      "total": 195.88,
      "electricity_usd_2026_kwh": 0.1485,
      "wacc": 0.1181,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 23.02,
      "electricity": 1.45,
      "site_grid": 1.93,
      "operations": 3.69,
      "total": 30.08,
      "electricity_usd_2026_kwh": 0.1427,
      "wacc": 0.1056,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 29.16,
      "electricity": 1.87,
      "site_grid": 1.77,
      "operations": 5.9,
      "total": 38.7,
      "electricity_usd_2026_kwh": 0.1427,
      "wacc": 0.1056,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 49.31,
      "electricity": 3.94,
      "site_grid": 4.13,
      "operations": 8.48,
      "total": 65.87,
      "electricity_usd_2026_kwh": 0.1427,
      "wacc": 0.1056,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 62.48,
      "electricity": 5.08,
      "site_grid": 3.79,
      "operations": 13.88,
      "total": 85.22,
      "electricity_usd_2026_kwh": 0.1427,
      "wacc": 0.1056,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 109.1,
      "electricity": 9.28,
      "site_grid": 9.14,
      "operations": 20.06,
      "total": 147.58,
      "electricity_usd_2026_kwh": 0.1427,
      "wacc": 0.1056,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 138.22,
      "electricity": 11.95,
      "site_grid": 8.38,
      "operations": 33.43,
      "total": 191.99,
      "electricity_usd_2026_kwh": 0.1427,
      "wacc": 0.1056,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 23.24,
      "electricity": 1.53,
      "site_grid": 2.0,
      "operations": 3.69,
      "total": 30.46,
      "electricity_usd_2026_kwh": 0.15,
      "wacc": 0.1112,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 29.45,
      "electricity": 1.97,
      "site_grid": 1.83,
      "operations": 5.9,
      "total": 39.14,
      "electricity_usd_2026_kwh": 0.15,
      "wacc": 0.1112,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 49.8,
      "electricity": 4.14,
      "site_grid": 4.29,
      "operations": 8.48,
      "total": 66.71,
      "electricity_usd_2026_kwh": 0.15,
      "wacc": 0.1112,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 63.09,
      "electricity": 5.33,
      "site_grid": 3.91,
      "operations": 13.88,
      "total": 86.21,
      "electricity_usd_2026_kwh": 0.15,
      "wacc": 0.1112,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 110.17,
      "electricity": 9.76,
      "site_grid": 9.48,
      "operations": 20.06,
      "total": 149.47,
      "electricity_usd_2026_kwh": 0.15,
      "wacc": 0.1112,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 139.58,
      "electricity": 12.56,
      "site_grid": 8.65,
      "operations": 33.43,
      "total": 194.22,
      "electricity_usd_2026_kwh": 0.15,
      "wacc": 0.1112,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 23.86,
      "electricity": 1.66,
      "site_grid": 2.46,
      "operations": 3.69,
      "total": 31.67,
      "electricity_usd_2026_kwh": 0.1631,
      "wacc": 0.1262,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 30.22,
      "electricity": 2.14,
      "site_grid": 2.22,
      "operations": 5.9,
      "total": 40.48,
      "electricity_usd_2026_kwh": 0.1631,
      "wacc": 0.1262,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 51.11,
      "electricity": 4.51,
      "site_grid": 5.27,
      "operations": 8.48,
      "total": 69.37,
      "electricity_usd_2026_kwh": 0.1631,
      "wacc": 0.1262,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 64.74,
      "electricity": 5.8,
      "site_grid": 4.75,
      "operations": 13.88,
      "total": 89.17,
      "electricity_usd_2026_kwh": 0.1631,
      "wacc": 0.1262,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 113.08,
      "electricity": 10.61,
      "site_grid": 11.67,
      "operations": 20.06,
      "total": 155.42,
      "electricity_usd_2026_kwh": 0.1631,
      "wacc": 0.1262,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 143.24,
      "electricity": 13.66,
      "site_grid": 10.51,
      "operations": 33.43,
      "total": 200.83,
      "electricity_usd_2026_kwh": 0.1631,
      "wacc": 0.1262,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 24.27,
      "electricity": 1.6,
      "site_grid": 2.68,
      "operations": 3.69,
      "total": 32.24,
      "electricity_usd_2026_kwh": 0.1573,
      "wacc": 0.1363,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 30.74,
      "electricity": 2.06,
      "site_grid": 2.4,
      "operations": 5.9,
      "total": 41.1,
      "electricity_usd_2026_kwh": 0.1573,
      "wacc": 0.1363,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 52.0,
      "electricity": 4.34,
      "site_grid": 5.75,
      "operations": 8.48,
      "total": 70.57,
      "electricity_usd_2026_kwh": 0.1573,
      "wacc": 0.1363,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 65.86,
      "electricity": 5.59,
      "site_grid": 5.14,
      "operations": 13.88,
      "total": 90.47,
      "electricity_usd_2026_kwh": 0.1573,
      "wacc": 0.1363,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 115.04,
      "electricity": 10.23,
      "site_grid": 12.72,
      "operations": 20.06,
      "total": 158.05,
      "electricity_usd_2026_kwh": 0.1573,
      "wacc": 0.1363,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 145.7,
      "electricity": 13.17,
      "site_grid": 11.36,
      "operations": 33.43,
      "total": 203.66,
      "electricity_usd_2026_kwh": 0.1573,
      "wacc": 0.1363,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 24.37,
      "electricity": 1.53,
      "site_grid": 2.63,
      "operations": 3.69,
      "total": 32.22,
      "electricity_usd_2026_kwh": 0.15,
      "wacc": 0.1388,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 30.87,
      "electricity": 1.97,
      "site_grid": 2.35,
      "operations": 5.9,
      "total": 41.08,
      "electricity_usd_2026_kwh": 0.15,
      "wacc": 0.1388,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 52.22,
      "electricity": 4.14,
      "site_grid": 5.64,
      "operations": 8.48,
      "total": 70.48,
      "electricity_usd_2026_kwh": 0.15,
      "wacc": 0.1388,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 66.14,
      "electricity": 5.33,
      "site_grid": 5.03,
      "operations": 13.88,
      "total": 90.37,
      "electricity_usd_2026_kwh": 0.15,
      "wacc": 0.1388,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 115.53,
      "electricity": 9.76,
      "site_grid": 12.47,
      "operations": 20.06,
      "total": 157.82,
      "electricity_usd_2026_kwh": 0.15,
      "wacc": 0.1388,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 146.32,
      "electricity": 12.56,
      "site_grid": 11.12,
      "operations": 33.43,
      "total": 203.43,
      "electricity_usd_2026_kwh": 0.15,
      "wacc": 0.1388,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 24.41,
      "electricity": 1.48,
      "site_grid": 2.61,
      "operations": 3.69,
      "total": 32.19,
      "electricity_usd_2026_kwh": 0.1456,
      "wacc": 0.1396,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 30.91,
      "electricity": 1.91,
      "site_grid": 2.32,
      "operations": 5.9,
      "total": 41.05,
      "electricity_usd_2026_kwh": 0.1456,
      "wacc": 0.1396,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 52.29,
      "electricity": 4.02,
      "site_grid": 5.59,
      "operations": 8.48,
      "total": 70.39,
      "electricity_usd_2026_kwh": 0.1456,
      "wacc": 0.1396,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 66.23,
      "electricity": 5.18,
      "site_grid": 4.98,
      "operations": 13.88,
      "total": 90.27,
      "electricity_usd_2026_kwh": 0.1456,
      "wacc": 0.1396,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 115.69,
      "electricity": 9.47,
      "site_grid": 12.36,
      "operations": 20.06,
      "total": 157.59,
      "electricity_usd_2026_kwh": 0.1456,
      "wacc": 0.1396,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 146.53,
      "electricity": 12.2,
      "site_grid": 11.02,
      "operations": 33.43,
      "total": 203.17,
      "electricity_usd_2026_kwh": 0.1456,
      "wacc": 0.1396,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 24.42,
      "electricity": 1.48,
      "site_grid": 2.62,
      "operations": 3.69,
      "total": 32.21,
      "electricity_usd_2026_kwh": 0.1456,
      "wacc": 0.14,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 30.93,
      "electricity": 1.91,
      "site_grid": 2.33,
      "operations": 5.9,
      "total": 41.08,
      "electricity_usd_2026_kwh": 0.1456,
      "wacc": 0.14,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 52.33,
      "electricity": 4.02,
      "site_grid": 5.61,
      "operations": 8.48,
      "total": 70.45,
      "electricity_usd_2026_kwh": 0.1456,
      "wacc": 0.14,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 66.27,
      "electricity": 5.18,
      "site_grid": 5.0,
      "operations": 13.88,
      "total": 90.33,
      "electricity_usd_2026_kwh": 0.1456,
      "wacc": 0.14,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 115.77,
      "electricity": 9.47,
      "site_grid": 12.42,
      "operations": 20.06,
      "total": 157.72,
      "electricity_usd_2026_kwh": 0.1456,
      "wacc": 0.14,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 146.62,
      "electricity": 12.2,
      "site_grid": 11.07,
      "operations": 33.43,
      "total": 203.31,
      "electricity_usd_2026_kwh": 0.1456,
      "wacc": 0.14,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.15,
      "electricity": 1.27,
      "site_grid": 1.58,
      "operations": 3.38,
      "total": 26.37,
      "electricity_usd_2026_kwh": 0.13,
      "wacc": 0.0938,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.44,
      "electricity": 1.63,
      "site_grid": 1.44,
      "operations": 5.69,
      "total": 34.19,
      "electricity_usd_2026_kwh": 0.13,
      "wacc": 0.0938,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 43.17,
      "electricity": 3.43,
      "site_grid": 3.38,
      "operations": 7.82,
      "total": 57.81,
      "electricity_usd_2026_kwh": 0.13,
      "wacc": 0.0938,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 54.5,
      "electricity": 4.41,
      "site_grid": 3.08,
      "operations": 13.41,
      "total": 75.4,
      "electricity_usd_2026_kwh": 0.13,
      "wacc": 0.0938,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 95.51,
      "electricity": 8.08,
      "site_grid": 7.49,
      "operations": 18.6,
      "total": 129.68,
      "electricity_usd_2026_kwh": 0.13,
      "wacc": 0.0938,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 120.58,
      "electricity": 10.38,
      "site_grid": 6.82,
      "operations": 32.37,
      "total": 170.15,
      "electricity_usd_2026_kwh": 0.13,
      "wacc": 0.0938,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.99,
      "electricity": 1.29,
      "site_grid": 1.52,
      "operations": 3.38,
      "total": 26.18,
      "electricity_usd_2026_kwh": 0.1324,
      "wacc": 0.0895,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.24,
      "electricity": 1.66,
      "site_grid": 1.39,
      "operations": 5.69,
      "total": 33.98,
      "electricity_usd_2026_kwh": 0.1324,
      "wacc": 0.0895,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.84,
      "electricity": 3.5,
      "site_grid": 3.25,
      "operations": 7.82,
      "total": 57.41,
      "electricity_usd_2026_kwh": 0.1324,
      "wacc": 0.0895,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 54.08,
      "electricity": 4.49,
      "site_grid": 2.98,
      "operations": 13.41,
      "total": 74.96,
      "electricity_usd_2026_kwh": 0.1324,
      "wacc": 0.0895,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.77,
      "electricity": 8.23,
      "site_grid": 7.2,
      "operations": 18.6,
      "total": 128.8,
      "electricity_usd_2026_kwh": 0.1324,
      "wacc": 0.0895,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2011,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 119.65,
      "electricity": 10.57,
      "site_grid": 6.58,
      "operations": 32.37,
      "total": 169.18,
      "electricity_usd_2026_kwh": 0.1324,
      "wacc": 0.0895,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.64,
      "electricity": 1.3,
      "site_grid": 1.44,
      "operations": 3.38,
      "total": 25.76,
      "electricity_usd_2026_kwh": 0.1336,
      "wacc": 0.0797,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.8,
      "electricity": 1.67,
      "site_grid": 1.33,
      "operations": 5.69,
      "total": 33.49,
      "electricity_usd_2026_kwh": 0.1336,
      "wacc": 0.0797,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.09,
      "electricity": 3.53,
      "site_grid": 3.08,
      "operations": 7.82,
      "total": 56.51,
      "electricity_usd_2026_kwh": 0.1336,
      "wacc": 0.0797,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.14,
      "electricity": 4.53,
      "site_grid": 2.84,
      "operations": 13.41,
      "total": 73.93,
      "electricity_usd_2026_kwh": 0.1336,
      "wacc": 0.0797,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 93.11,
      "electricity": 8.31,
      "site_grid": 6.81,
      "operations": 18.6,
      "total": 126.83,
      "electricity_usd_2026_kwh": 0.1336,
      "wacc": 0.0797,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2012,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 117.57,
      "electricity": 10.67,
      "site_grid": 6.29,
      "operations": 32.37,
      "total": 166.9,
      "electricity_usd_2026_kwh": 0.1336,
      "wacc": 0.0797,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.84,
      "electricity": 1.29,
      "site_grid": 1.5,
      "operations": 3.38,
      "total": 26.01,
      "electricity_usd_2026_kwh": 0.1324,
      "wacc": 0.0852,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.05,
      "electricity": 1.66,
      "site_grid": 1.38,
      "operations": 5.69,
      "total": 33.77,
      "electricity_usd_2026_kwh": 0.1324,
      "wacc": 0.0852,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.51,
      "electricity": 3.5,
      "site_grid": 3.21,
      "operations": 7.82,
      "total": 57.03,
      "electricity_usd_2026_kwh": 0.1324,
      "wacc": 0.0852,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.67,
      "electricity": 4.49,
      "site_grid": 2.95,
      "operations": 13.41,
      "total": 74.52,
      "electricity_usd_2026_kwh": 0.1324,
      "wacc": 0.0852,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.04,
      "electricity": 8.23,
      "site_grid": 7.1,
      "operations": 18.6,
      "total": 127.97,
      "electricity_usd_2026_kwh": 0.1324,
      "wacc": 0.0852,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2013,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 118.73,
      "electricity": 10.57,
      "site_grid": 6.53,
      "operations": 32.37,
      "total": 168.2,
      "electricity_usd_2026_kwh": 0.1324,
      "wacc": 0.0852,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.91,
      "electricity": 1.25,
      "site_grid": 1.54,
      "operations": 3.38,
      "total": 26.08,
      "electricity_usd_2026_kwh": 0.1288,
      "wacc": 0.0871,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.13,
      "electricity": 1.61,
      "site_grid": 1.41,
      "operations": 5.69,
      "total": 33.84,
      "electricity_usd_2026_kwh": 0.1288,
      "wacc": 0.0871,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.65,
      "electricity": 3.4,
      "site_grid": 3.3,
      "operations": 7.82,
      "total": 57.17,
      "electricity_usd_2026_kwh": 0.1288,
      "wacc": 0.0871,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.85,
      "electricity": 4.37,
      "site_grid": 3.03,
      "operations": 13.41,
      "total": 74.65,
      "electricity_usd_2026_kwh": 0.1288,
      "wacc": 0.0871,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.36,
      "electricity": 8.01,
      "site_grid": 7.3,
      "operations": 18.6,
      "total": 128.27,
      "electricity_usd_2026_kwh": 0.1288,
      "wacc": 0.0871,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2014,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 119.14,
      "electricity": 10.29,
      "site_grid": 6.69,
      "operations": 32.37,
      "total": 168.49,
      "electricity_usd_2026_kwh": 0.1288,
      "wacc": 0.0871,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.76,
      "electricity": 1.21,
      "site_grid": 1.53,
      "operations": 3.38,
      "total": 25.88,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.0831,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.95,
      "electricity": 1.55,
      "site_grid": 1.41,
      "operations": 5.69,
      "total": 33.6,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.0831,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.34,
      "electricity": 3.27,
      "site_grid": 3.28,
      "operations": 7.82,
      "total": 56.72,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.0831,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.46,
      "electricity": 4.2,
      "site_grid": 3.02,
      "operations": 13.41,
      "total": 74.09,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.0831,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 93.68,
      "electricity": 7.71,
      "site_grid": 7.25,
      "operations": 18.6,
      "total": 127.24,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.0831,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2015,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 118.28,
      "electricity": 9.9,
      "site_grid": 6.68,
      "operations": 32.37,
      "total": 167.23,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.0831,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.66,
      "electricity": 1.17,
      "site_grid": 1.49,
      "operations": 3.38,
      "total": 25.7,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0801,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.82,
      "electricity": 1.51,
      "site_grid": 1.38,
      "operations": 5.69,
      "total": 33.39,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0801,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.11,
      "electricity": 3.18,
      "site_grid": 3.19,
      "operations": 7.82,
      "total": 56.31,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0801,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.17,
      "electricity": 4.08,
      "site_grid": 2.95,
      "operations": 13.41,
      "total": 73.62,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0801,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 93.17,
      "electricity": 7.48,
      "site_grid": 7.07,
      "operations": 18.6,
      "total": 126.32,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0801,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2016,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 117.64,
      "electricity": 9.61,
      "site_grid": 6.53,
      "operations": 32.37,
      "total": 166.16,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0801,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.83,
      "electricity": 1.18,
      "site_grid": 1.54,
      "operations": 3.38,
      "total": 25.94,
      "electricity_usd_2026_kwh": 0.1216,
      "wacc": 0.085,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.04,
      "electricity": 1.52,
      "site_grid": 1.42,
      "operations": 5.69,
      "total": 33.67,
      "electricity_usd_2026_kwh": 0.1216,
      "wacc": 0.085,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.49,
      "electricity": 3.21,
      "site_grid": 3.31,
      "operations": 7.82,
      "total": 56.83,
      "electricity_usd_2026_kwh": 0.1216,
      "wacc": 0.085,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.65,
      "electricity": 4.12,
      "site_grid": 3.04,
      "operations": 13.41,
      "total": 74.22,
      "electricity_usd_2026_kwh": 0.1216,
      "wacc": 0.085,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.0,
      "electricity": 7.56,
      "site_grid": 7.32,
      "operations": 18.6,
      "total": 127.48,
      "electricity_usd_2026_kwh": 0.1216,
      "wacc": 0.085,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2017,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 118.69,
      "electricity": 9.71,
      "site_grid": 6.73,
      "operations": 32.37,
      "total": 167.49,
      "electricity_usd_2026_kwh": 0.1216,
      "wacc": 0.085,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.04,
      "electricity": 1.22,
      "site_grid": 1.64,
      "operations": 3.38,
      "total": 26.27,
      "electricity_usd_2026_kwh": 0.1252,
      "wacc": 0.0908,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.3,
      "electricity": 1.57,
      "site_grid": 1.49,
      "operations": 5.69,
      "total": 34.05,
      "electricity_usd_2026_kwh": 0.1252,
      "wacc": 0.0908,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.94,
      "electricity": 3.31,
      "site_grid": 3.5,
      "operations": 7.82,
      "total": 57.57,
      "electricity_usd_2026_kwh": 0.1252,
      "wacc": 0.0908,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 54.21,
      "electricity": 4.24,
      "site_grid": 3.2,
      "operations": 13.41,
      "total": 75.06,
      "electricity_usd_2026_kwh": 0.1252,
      "wacc": 0.0908,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 94.99,
      "electricity": 7.78,
      "site_grid": 7.75,
      "operations": 18.6,
      "total": 129.13,
      "electricity_usd_2026_kwh": 0.1252,
      "wacc": 0.0908,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2018,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 119.93,
      "electricity": 10.0,
      "site_grid": 7.08,
      "operations": 32.37,
      "total": 169.38,
      "electricity_usd_2026_kwh": 0.1252,
      "wacc": 0.0908,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.76,
      "electricity": 1.2,
      "site_grid": 1.62,
      "operations": 3.38,
      "total": 25.96,
      "electricity_usd_2026_kwh": 0.1228,
      "wacc": 0.0831,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.96,
      "electricity": 1.54,
      "site_grid": 1.5,
      "operations": 5.69,
      "total": 33.67,
      "electricity_usd_2026_kwh": 0.1228,
      "wacc": 0.0831,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.35,
      "electricity": 3.24,
      "site_grid": 3.48,
      "operations": 7.82,
      "total": 56.89,
      "electricity_usd_2026_kwh": 0.1228,
      "wacc": 0.0831,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 53.47,
      "electricity": 4.16,
      "site_grid": 3.2,
      "operations": 13.41,
      "total": 74.24,
      "electricity_usd_2026_kwh": 0.1228,
      "wacc": 0.0831,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 93.68,
      "electricity": 7.63,
      "site_grid": 7.69,
      "operations": 18.6,
      "total": 127.61,
      "electricity_usd_2026_kwh": 0.1228,
      "wacc": 0.0831,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2019,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 118.29,
      "electricity": 9.8,
      "site_grid": 7.09,
      "operations": 32.37,
      "total": 167.55,
      "electricity_usd_2026_kwh": 0.1228,
      "wacc": 0.0831,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.32,
      "electricity": 1.15,
      "site_grid": 1.52,
      "operations": 3.38,
      "total": 25.37,
      "electricity_usd_2026_kwh": 0.118,
      "wacc": 0.0706,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.4,
      "electricity": 1.48,
      "site_grid": 1.42,
      "operations": 5.69,
      "total": 32.98,
      "electricity_usd_2026_kwh": 0.118,
      "wacc": 0.0706,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.39,
      "electricity": 3.11,
      "site_grid": 3.27,
      "operations": 7.82,
      "total": 55.59,
      "electricity_usd_2026_kwh": 0.118,
      "wacc": 0.0706,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.27,
      "electricity": 4.0,
      "site_grid": 3.05,
      "operations": 13.41,
      "total": 72.73,
      "electricity_usd_2026_kwh": 0.118,
      "wacc": 0.0706,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 91.57,
      "electricity": 7.34,
      "site_grid": 7.22,
      "operations": 18.6,
      "total": 124.73,
      "electricity_usd_2026_kwh": 0.118,
      "wacc": 0.0706,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2020,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 115.63,
      "electricity": 9.42,
      "site_grid": 6.75,
      "operations": 32.37,
      "total": 164.18,
      "electricity_usd_2026_kwh": 0.118,
      "wacc": 0.0706,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 19.52,
      "electricity": 1.21,
      "site_grid": 1.59,
      "operations": 3.38,
      "total": 25.69,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.0762,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 24.64,
      "electricity": 1.55,
      "site_grid": 1.47,
      "operations": 5.69,
      "total": 33.36,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.0762,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 41.82,
      "electricity": 3.27,
      "site_grid": 3.4,
      "operations": 7.82,
      "total": 56.31,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.0762,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 52.8,
      "electricity": 4.2,
      "site_grid": 3.16,
      "operations": 13.41,
      "total": 73.57,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.0762,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 92.51,
      "electricity": 7.71,
      "site_grid": 7.53,
      "operations": 18.6,
      "total": 126.35,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.0762,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2021,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 116.81,
      "electricity": 9.9,
      "site_grid": 6.99,
      "operations": 32.37,
      "total": 166.07,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.0762,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.05,
      "electricity": 1.31,
      "site_grid": 1.97,
      "operations": 3.38,
      "total": 26.72,
      "electricity_usd_2026_kwh": 0.1349,
      "wacc": 0.0912,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.32,
      "electricity": 1.69,
      "site_grid": 1.8,
      "operations": 5.69,
      "total": 34.5,
      "electricity_usd_2026_kwh": 0.1349,
      "wacc": 0.0912,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 42.97,
      "electricity": 3.56,
      "site_grid": 4.23,
      "operations": 7.82,
      "total": 58.58,
      "electricity_usd_2026_kwh": 0.1349,
      "wacc": 0.0912,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 54.25,
      "electricity": 4.57,
      "site_grid": 3.86,
      "operations": 13.41,
      "total": 76.09,
      "electricity_usd_2026_kwh": 0.1349,
      "wacc": 0.0912,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 95.06,
      "electricity": 8.38,
      "site_grid": 9.36,
      "operations": 18.6,
      "total": 131.4,
      "electricity_usd_2026_kwh": 0.1349,
      "wacc": 0.0912,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2022,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 120.01,
      "electricity": 10.77,
      "site_grid": 8.55,
      "operations": 32.37,
      "total": 171.7,
      "electricity_usd_2026_kwh": 0.1349,
      "wacc": 0.0912,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.42,
      "electricity": 1.27,
      "site_grid": 2.17,
      "operations": 3.38,
      "total": 27.23,
      "electricity_usd_2026_kwh": 0.13,
      "wacc": 0.1013,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.77,
      "electricity": 1.63,
      "site_grid": 1.96,
      "operations": 5.69,
      "total": 35.05,
      "electricity_usd_2026_kwh": 0.13,
      "wacc": 0.1013,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 43.75,
      "electricity": 3.43,
      "site_grid": 4.64,
      "operations": 7.82,
      "total": 59.64,
      "electricity_usd_2026_kwh": 0.13,
      "wacc": 0.1013,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 55.22,
      "electricity": 4.41,
      "site_grid": 4.2,
      "operations": 13.41,
      "total": 77.24,
      "electricity_usd_2026_kwh": 0.13,
      "wacc": 0.1013,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 96.78,
      "electricity": 8.08,
      "site_grid": 10.27,
      "operations": 18.6,
      "total": 133.73,
      "electricity_usd_2026_kwh": 0.13,
      "wacc": 0.1013,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2023,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 122.17,
      "electricity": 10.38,
      "site_grid": 9.28,
      "operations": 32.37,
      "total": 174.21,
      "electricity_usd_2026_kwh": 0.13,
      "wacc": 0.1013,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.51,
      "electricity": 1.21,
      "site_grid": 2.13,
      "operations": 3.38,
      "total": 27.22,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.1038,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.89,
      "electricity": 1.55,
      "site_grid": 1.92,
      "operations": 5.69,
      "total": 35.04,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.1038,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 43.94,
      "electricity": 3.27,
      "site_grid": 4.56,
      "operations": 7.82,
      "total": 59.59,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.1038,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 55.46,
      "electricity": 4.2,
      "site_grid": 4.11,
      "operations": 13.41,
      "total": 77.19,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.1038,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 97.21,
      "electricity": 7.71,
      "site_grid": 10.09,
      "operations": 18.6,
      "total": 133.6,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.1038,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2024,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 122.71,
      "electricity": 9.9,
      "site_grid": 9.1,
      "operations": 32.37,
      "total": 174.07,
      "electricity_usd_2026_kwh": 0.124,
      "wacc": 0.1038,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.54,
      "electricity": 1.17,
      "site_grid": 2.11,
      "operations": 3.38,
      "total": 27.2,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.1046,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.93,
      "electricity": 1.51,
      "site_grid": 1.9,
      "operations": 5.69,
      "total": 35.02,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.1046,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 44.0,
      "electricity": 3.18,
      "site_grid": 4.52,
      "operations": 7.82,
      "total": 59.53,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.1046,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 55.55,
      "electricity": 4.08,
      "site_grid": 4.08,
      "operations": 13.41,
      "total": 77.11,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.1046,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 97.35,
      "electricity": 7.48,
      "site_grid": 10.01,
      "operations": 18.6,
      "total": 133.44,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.1046,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2025,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 122.89,
      "electricity": 9.61,
      "site_grid": 9.02,
      "operations": 32.37,
      "total": 173.89,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.1046,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 20.55,
      "electricity": 1.17,
      "site_grid": 2.12,
      "operations": 3.38,
      "total": 27.22,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.105,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 25.94,
      "electricity": 1.51,
      "site_grid": 1.91,
      "operations": 5.69,
      "total": 35.05,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.105,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 44.03,
      "electricity": 3.18,
      "site_grid": 4.55,
      "operations": 7.82,
      "total": 59.58,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.105,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 55.58,
      "electricity": 4.08,
      "site_grid": 4.09,
      "operations": 13.41,
      "total": 77.17,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.105,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 97.42,
      "electricity": 7.48,
      "site_grid": 10.06,
      "operations": 18.6,
      "total": 133.56,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.105,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2026,
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 122.97,
      "electricity": 9.61,
      "site_grid": 9.06,
      "operations": 32.37,
      "total": 174.01,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.105,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "C"
    },
    {
      "year": 2010,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.47,
      "electricity": 0.58,
      "site_grid": 1.37,
      "operations": 3.34,
      "total": 23.76,
      "electricity_usd_2026_kwh": 0.0565,
      "wacc": 0.0668,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.27,
      "electricity": 0.75,
      "site_grid": 1.29,
      "operations": 5.71,
      "total": 31.01,
      "electricity_usd_2026_kwh": 0.0565,
      "wacc": 0.0668,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.57,
      "electricity": 1.58,
      "site_grid": 2.94,
      "operations": 7.73,
      "total": 51.83,
      "electricity_usd_2026_kwh": 0.0565,
      "wacc": 0.0668,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.86,
      "electricity": 2.02,
      "site_grid": 2.76,
      "operations": 13.45,
      "total": 68.09,
      "electricity_usd_2026_kwh": 0.0565,
      "wacc": 0.0668,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.55,
      "electricity": 3.72,
      "site_grid": 6.51,
      "operations": 18.4,
      "total": 116.18,
      "electricity_usd_2026_kwh": 0.0565,
      "wacc": 0.0668,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.3,
      "electricity": 4.76,
      "site_grid": 6.1,
      "operations": 32.46,
      "total": 153.62,
      "electricity_usd_2026_kwh": 0.0565,
      "wacc": 0.0668,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.32,
      "electricity": 0.59,
      "site_grid": 1.32,
      "operations": 3.34,
      "total": 23.57,
      "electricity_usd_2026_kwh": 0.0572,
      "wacc": 0.0625,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.08,
      "electricity": 0.75,
      "site_grid": 1.24,
      "operations": 5.71,
      "total": 30.79,
      "electricity_usd_2026_kwh": 0.0572,
      "wacc": 0.0625,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.26,
      "electricity": 1.6,
      "site_grid": 2.82,
      "operations": 7.73,
      "total": 51.41,
      "electricity_usd_2026_kwh": 0.0572,
      "wacc": 0.0625,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.46,
      "electricity": 2.04,
      "site_grid": 2.66,
      "operations": 13.45,
      "total": 67.62,
      "electricity_usd_2026_kwh": 0.0572,
      "wacc": 0.0625,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.85,
      "electricity": 3.76,
      "site_grid": 6.24,
      "operations": 18.4,
      "total": 115.26,
      "electricity_usd_2026_kwh": 0.0572,
      "wacc": 0.0625,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.42,
      "electricity": 4.82,
      "site_grid": 5.88,
      "operations": 32.46,
      "total": 152.58,
      "electricity_usd_2026_kwh": 0.0572,
      "wacc": 0.0625,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.99,
      "electricity": 0.6,
      "site_grid": 1.24,
      "operations": 3.34,
      "total": 23.16,
      "electricity_usd_2026_kwh": 0.0578,
      "wacc": 0.0527,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.67,
      "electricity": 0.76,
      "site_grid": 1.18,
      "operations": 5.71,
      "total": 30.32,
      "electricity_usd_2026_kwh": 0.0578,
      "wacc": 0.0527,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.55,
      "electricity": 1.62,
      "site_grid": 2.65,
      "operations": 7.73,
      "total": 50.55,
      "electricity_usd_2026_kwh": 0.0578,
      "wacc": 0.0527,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.57,
      "electricity": 2.07,
      "site_grid": 2.53,
      "operations": 13.45,
      "total": 66.62,
      "electricity_usd_2026_kwh": 0.0578,
      "wacc": 0.0527,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.28,
      "electricity": 3.81,
      "site_grid": 5.87,
      "operations": 18.4,
      "total": 113.35,
      "electricity_usd_2026_kwh": 0.0578,
      "wacc": 0.0527,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.45,
      "electricity": 4.87,
      "site_grid": 5.6,
      "operations": 32.46,
      "total": 150.38,
      "electricity_usd_2026_kwh": 0.0578,
      "wacc": 0.0527,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.18,
      "electricity": 0.6,
      "site_grid": 1.3,
      "operations": 3.34,
      "total": 23.41,
      "electricity_usd_2026_kwh": 0.0578,
      "wacc": 0.0582,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.9,
      "electricity": 0.76,
      "site_grid": 1.23,
      "operations": 5.71,
      "total": 30.6,
      "electricity_usd_2026_kwh": 0.0578,
      "wacc": 0.0582,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.94,
      "electricity": 1.62,
      "site_grid": 2.78,
      "operations": 7.73,
      "total": 51.07,
      "electricity_usd_2026_kwh": 0.0578,
      "wacc": 0.0582,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.07,
      "electricity": 2.07,
      "site_grid": 2.63,
      "operations": 13.45,
      "total": 67.22,
      "electricity_usd_2026_kwh": 0.0578,
      "wacc": 0.0582,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.16,
      "electricity": 3.81,
      "site_grid": 6.14,
      "operations": 18.4,
      "total": 114.51,
      "electricity_usd_2026_kwh": 0.0578,
      "wacc": 0.0582,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.55,
      "electricity": 4.87,
      "site_grid": 5.82,
      "operations": 32.46,
      "total": 151.7,
      "electricity_usd_2026_kwh": 0.0578,
      "wacc": 0.0582,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.24,
      "electricity": 0.6,
      "site_grid": 1.33,
      "operations": 3.34,
      "total": 23.51,
      "electricity_usd_2026_kwh": 0.0584,
      "wacc": 0.0601,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.98,
      "electricity": 0.77,
      "site_grid": 1.26,
      "operations": 5.71,
      "total": 30.72,
      "electricity_usd_2026_kwh": 0.0584,
      "wacc": 0.0601,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.08,
      "electricity": 1.63,
      "site_grid": 2.86,
      "operations": 7.73,
      "total": 51.31,
      "electricity_usd_2026_kwh": 0.0584,
      "wacc": 0.0601,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.24,
      "electricity": 2.09,
      "site_grid": 2.7,
      "operations": 13.45,
      "total": 67.48,
      "electricity_usd_2026_kwh": 0.0584,
      "wacc": 0.0601,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.46,
      "electricity": 3.85,
      "site_grid": 6.32,
      "operations": 18.4,
      "total": 115.03,
      "electricity_usd_2026_kwh": 0.0584,
      "wacc": 0.0601,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.94,
      "electricity": 4.92,
      "site_grid": 5.98,
      "operations": 32.46,
      "total": 152.29,
      "electricity_usd_2026_kwh": 0.0584,
      "wacc": 0.0601,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.1,
      "electricity": 0.61,
      "site_grid": 1.32,
      "operations": 3.34,
      "total": 23.37,
      "electricity_usd_2026_kwh": 0.0591,
      "wacc": 0.0561,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.81,
      "electricity": 0.78,
      "site_grid": 1.26,
      "operations": 5.71,
      "total": 30.56,
      "electricity_usd_2026_kwh": 0.0591,
      "wacc": 0.0561,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.79,
      "electricity": 1.65,
      "site_grid": 2.83,
      "operations": 7.73,
      "total": 51.01,
      "electricity_usd_2026_kwh": 0.0591,
      "wacc": 0.0561,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.87,
      "electricity": 2.11,
      "site_grid": 2.69,
      "operations": 13.45,
      "total": 67.13,
      "electricity_usd_2026_kwh": 0.0591,
      "wacc": 0.0561,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.82,
      "electricity": 3.89,
      "site_grid": 6.26,
      "operations": 18.4,
      "total": 114.37,
      "electricity_usd_2026_kwh": 0.0591,
      "wacc": 0.0561,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.13,
      "electricity": 4.98,
      "site_grid": 5.95,
      "operations": 32.46,
      "total": 151.51,
      "electricity_usd_2026_kwh": 0.0591,
      "wacc": 0.0561,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.0,
      "electricity": 0.62,
      "site_grid": 1.29,
      "operations": 3.34,
      "total": 23.24,
      "electricity_usd_2026_kwh": 0.0597,
      "wacc": 0.0531,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.68,
      "electricity": 0.79,
      "site_grid": 1.23,
      "operations": 5.71,
      "total": 30.41,
      "electricity_usd_2026_kwh": 0.0597,
      "wacc": 0.0531,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.57,
      "electricity": 1.67,
      "site_grid": 2.75,
      "operations": 7.73,
      "total": 50.73,
      "electricity_usd_2026_kwh": 0.0597,
      "wacc": 0.0531,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.6,
      "electricity": 2.14,
      "site_grid": 2.63,
      "operations": 13.45,
      "total": 66.82,
      "electricity_usd_2026_kwh": 0.0597,
      "wacc": 0.0531,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.34,
      "electricity": 3.93,
      "site_grid": 6.09,
      "operations": 18.4,
      "total": 113.76,
      "electricity_usd_2026_kwh": 0.0597,
      "wacc": 0.0531,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.52,
      "electricity": 5.03,
      "site_grid": 5.82,
      "operations": 32.46,
      "total": 150.83,
      "electricity_usd_2026_kwh": 0.0597,
      "wacc": 0.0531,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.17,
      "electricity": 0.62,
      "site_grid": 1.33,
      "operations": 3.34,
      "total": 23.46,
      "electricity_usd_2026_kwh": 0.0604,
      "wacc": 0.058,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.89,
      "electricity": 0.8,
      "site_grid": 1.27,
      "operations": 5.71,
      "total": 30.66,
      "electricity_usd_2026_kwh": 0.0604,
      "wacc": 0.058,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.93,
      "electricity": 1.69,
      "site_grid": 2.86,
      "operations": 7.73,
      "total": 51.21,
      "electricity_usd_2026_kwh": 0.0604,
      "wacc": 0.058,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.05,
      "electricity": 2.16,
      "site_grid": 2.71,
      "operations": 13.45,
      "total": 67.37,
      "electricity_usd_2026_kwh": 0.0604,
      "wacc": 0.058,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 86.12,
      "electricity": 3.98,
      "site_grid": 6.33,
      "operations": 18.4,
      "total": 114.83,
      "electricity_usd_2026_kwh": 0.0604,
      "wacc": 0.058,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.51,
      "electricity": 5.09,
      "site_grid": 6.0,
      "operations": 32.46,
      "total": 152.05,
      "electricity_usd_2026_kwh": 0.0604,
      "wacc": 0.058,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.37,
      "electricity": 0.63,
      "site_grid": 1.42,
      "operations": 3.34,
      "total": 23.75,
      "electricity_usd_2026_kwh": 0.061,
      "wacc": 0.0638,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.14,
      "electricity": 0.81,
      "site_grid": 1.34,
      "operations": 5.71,
      "total": 30.99,
      "electricity_usd_2026_kwh": 0.061,
      "wacc": 0.0638,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.35,
      "electricity": 1.71,
      "site_grid": 3.04,
      "operations": 7.73,
      "total": 51.83,
      "electricity_usd_2026_kwh": 0.061,
      "wacc": 0.0638,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.58,
      "electricity": 2.18,
      "site_grid": 2.86,
      "operations": 13.45,
      "total": 68.08,
      "electricity_usd_2026_kwh": 0.061,
      "wacc": 0.0638,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.06,
      "electricity": 4.02,
      "site_grid": 6.73,
      "operations": 18.4,
      "total": 116.21,
      "electricity_usd_2026_kwh": 0.061,
      "wacc": 0.0638,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.68,
      "electricity": 5.14,
      "site_grid": 6.33,
      "operations": 32.46,
      "total": 153.61,
      "electricity_usd_2026_kwh": 0.061,
      "wacc": 0.0638,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.11,
      "electricity": 0.64,
      "site_grid": 1.4,
      "operations": 3.34,
      "total": 23.48,
      "electricity_usd_2026_kwh": 0.0616,
      "wacc": 0.0561,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.81,
      "electricity": 0.81,
      "site_grid": 1.33,
      "operations": 5.71,
      "total": 30.67,
      "electricity_usd_2026_kwh": 0.0616,
      "wacc": 0.0561,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.79,
      "electricity": 1.72,
      "site_grid": 3.0,
      "operations": 7.73,
      "total": 51.25,
      "electricity_usd_2026_kwh": 0.0616,
      "wacc": 0.0561,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.88,
      "electricity": 2.21,
      "site_grid": 2.86,
      "operations": 13.45,
      "total": 67.39,
      "electricity_usd_2026_kwh": 0.0616,
      "wacc": 0.0561,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.82,
      "electricity": 4.06,
      "site_grid": 6.65,
      "operations": 18.4,
      "total": 114.93,
      "electricity_usd_2026_kwh": 0.0616,
      "wacc": 0.0561,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 108.13,
      "electricity": 5.19,
      "site_grid": 6.32,
      "operations": 32.46,
      "total": 152.1,
      "electricity_usd_2026_kwh": 0.0616,
      "wacc": 0.0561,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.68,
      "electricity": 0.64,
      "site_grid": 1.31,
      "operations": 3.34,
      "total": 22.96,
      "electricity_usd_2026_kwh": 0.0616,
      "wacc": 0.0436,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.28,
      "electricity": 0.81,
      "site_grid": 1.26,
      "operations": 5.71,
      "total": 30.07,
      "electricity_usd_2026_kwh": 0.0616,
      "wacc": 0.0436,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.89,
      "electricity": 1.72,
      "site_grid": 2.8,
      "operations": 7.73,
      "total": 50.14,
      "electricity_usd_2026_kwh": 0.0616,
      "wacc": 0.0436,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.74,
      "electricity": 2.21,
      "site_grid": 2.71,
      "operations": 13.45,
      "total": 66.11,
      "electricity_usd_2026_kwh": 0.0616,
      "wacc": 0.0436,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.82,
      "electricity": 4.06,
      "site_grid": 6.19,
      "operations": 18.4,
      "total": 112.47,
      "electricity_usd_2026_kwh": 0.0616,
      "wacc": 0.0436,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.62,
      "electricity": 5.19,
      "site_grid": 5.99,
      "operations": 32.46,
      "total": 149.26,
      "electricity_usd_2026_kwh": 0.0616,
      "wacc": 0.0436,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.87,
      "electricity": 0.64,
      "site_grid": 1.37,
      "operations": 3.34,
      "total": 23.22,
      "electricity_usd_2026_kwh": 0.0623,
      "wacc": 0.0492,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.52,
      "electricity": 0.82,
      "site_grid": 1.31,
      "operations": 5.71,
      "total": 30.36,
      "electricity_usd_2026_kwh": 0.0623,
      "wacc": 0.0492,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.29,
      "electricity": 1.74,
      "site_grid": 2.93,
      "operations": 7.73,
      "total": 50.69,
      "electricity_usd_2026_kwh": 0.0623,
      "wacc": 0.0492,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.25,
      "electricity": 2.23,
      "site_grid": 2.81,
      "operations": 13.45,
      "total": 66.74,
      "electricity_usd_2026_kwh": 0.0623,
      "wacc": 0.0492,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.71,
      "electricity": 4.1,
      "site_grid": 6.47,
      "operations": 18.4,
      "total": 113.69,
      "electricity_usd_2026_kwh": 0.0623,
      "wacc": 0.0492,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.74,
      "electricity": 5.25,
      "site_grid": 6.21,
      "operations": 32.46,
      "total": 150.66,
      "electricity_usd_2026_kwh": 0.0623,
      "wacc": 0.0492,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.38,
      "electricity": 0.65,
      "site_grid": 1.71,
      "operations": 3.34,
      "total": 24.08,
      "electricity_usd_2026_kwh": 0.0629,
      "wacc": 0.0642,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.16,
      "electricity": 0.83,
      "site_grid": 1.61,
      "operations": 5.71,
      "total": 31.31,
      "electricity_usd_2026_kwh": 0.0629,
      "wacc": 0.0642,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.38,
      "electricity": 1.76,
      "site_grid": 3.67,
      "operations": 7.73,
      "total": 52.55,
      "electricity_usd_2026_kwh": 0.0629,
      "wacc": 0.0642,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.61,
      "electricity": 2.25,
      "site_grid": 3.46,
      "operations": 13.45,
      "total": 68.77,
      "electricity_usd_2026_kwh": 0.0629,
      "wacc": 0.0642,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.13,
      "electricity": 4.15,
      "site_grid": 8.12,
      "operations": 18.4,
      "total": 117.8,
      "electricity_usd_2026_kwh": 0.0629,
      "wacc": 0.0642,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.76,
      "electricity": 5.3,
      "site_grid": 7.64,
      "operations": 32.46,
      "total": 155.17,
      "electricity_usd_2026_kwh": 0.0629,
      "wacc": 0.0642,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.73,
      "electricity": 0.66,
      "site_grid": 1.89,
      "operations": 3.34,
      "total": 24.61,
      "electricity_usd_2026_kwh": 0.0636,
      "wacc": 0.0743,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.59,
      "electricity": 0.84,
      "site_grid": 1.76,
      "operations": 5.71,
      "total": 31.89,
      "electricity_usd_2026_kwh": 0.0636,
      "wacc": 0.0743,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.12,
      "electricity": 1.78,
      "site_grid": 4.05,
      "operations": 7.73,
      "total": 53.68,
      "electricity_usd_2026_kwh": 0.0636,
      "wacc": 0.0743,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.54,
      "electricity": 2.27,
      "site_grid": 3.77,
      "operations": 13.45,
      "total": 70.03,
      "electricity_usd_2026_kwh": 0.0636,
      "wacc": 0.0743,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 88.76,
      "electricity": 4.19,
      "site_grid": 8.97,
      "operations": 18.4,
      "total": 120.31,
      "electricity_usd_2026_kwh": 0.0636,
      "wacc": 0.0743,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 111.81,
      "electricity": 5.36,
      "site_grid": 8.33,
      "operations": 32.46,
      "total": 157.95,
      "electricity_usd_2026_kwh": 0.0636,
      "wacc": 0.0743,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.81,
      "electricity": 0.66,
      "site_grid": 1.86,
      "operations": 3.34,
      "total": 24.67,
      "electricity_usd_2026_kwh": 0.0642,
      "wacc": 0.0768,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.69,
      "electricity": 0.85,
      "site_grid": 1.72,
      "operations": 5.71,
      "total": 31.98,
      "electricity_usd_2026_kwh": 0.0642,
      "wacc": 0.0768,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.3,
      "electricity": 1.8,
      "site_grid": 3.99,
      "operations": 7.73,
      "total": 53.82,
      "electricity_usd_2026_kwh": 0.0642,
      "wacc": 0.0768,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.77,
      "electricity": 2.3,
      "site_grid": 3.69,
      "operations": 13.45,
      "total": 70.21,
      "electricity_usd_2026_kwh": 0.0642,
      "wacc": 0.0768,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.16,
      "electricity": 4.23,
      "site_grid": 8.82,
      "operations": 18.4,
      "total": 120.61,
      "electricity_usd_2026_kwh": 0.0642,
      "wacc": 0.0768,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.31,
      "electricity": 5.41,
      "site_grid": 8.17,
      "operations": 32.46,
      "total": 158.35,
      "electricity_usd_2026_kwh": 0.0642,
      "wacc": 0.0768,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.84,
      "electricity": 0.66,
      "site_grid": 1.85,
      "operations": 3.34,
      "total": 24.69,
      "electricity_usd_2026_kwh": 0.0642,
      "wacc": 0.0776,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.73,
      "electricity": 0.85,
      "site_grid": 1.71,
      "operations": 5.71,
      "total": 32.0,
      "electricity_usd_2026_kwh": 0.0642,
      "wacc": 0.0776,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.36,
      "electricity": 1.8,
      "site_grid": 3.96,
      "operations": 7.73,
      "total": 53.85,
      "electricity_usd_2026_kwh": 0.0642,
      "wacc": 0.0776,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.84,
      "electricity": 2.3,
      "site_grid": 3.66,
      "operations": 13.45,
      "total": 70.26,
      "electricity_usd_2026_kwh": 0.0642,
      "wacc": 0.0776,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.3,
      "electricity": 4.23,
      "site_grid": 8.75,
      "operations": 18.4,
      "total": 120.68,
      "electricity_usd_2026_kwh": 0.0642,
      "wacc": 0.0776,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.49,
      "electricity": 5.41,
      "site_grid": 8.11,
      "operations": 32.46,
      "total": 158.46,
      "electricity_usd_2026_kwh": 0.0642,
      "wacc": 0.0776,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.85,
      "electricity": 0.66,
      "site_grid": 1.86,
      "operations": 3.34,
      "total": 24.71,
      "electricity_usd_2026_kwh": 0.0642,
      "wacc": 0.078,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.75,
      "electricity": 0.85,
      "site_grid": 1.72,
      "operations": 5.71,
      "total": 32.02,
      "electricity_usd_2026_kwh": 0.0642,
      "wacc": 0.078,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 40.39,
      "electricity": 1.8,
      "site_grid": 3.98,
      "operations": 7.73,
      "total": 53.9,
      "electricity_usd_2026_kwh": 0.0642,
      "wacc": 0.078,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 50.88,
      "electricity": 2.3,
      "site_grid": 3.68,
      "operations": 13.45,
      "total": 70.31,
      "electricity_usd_2026_kwh": 0.0642,
      "wacc": 0.078,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 89.36,
      "electricity": 4.23,
      "site_grid": 8.8,
      "operations": 18.4,
      "total": 120.79,
      "electricity_usd_2026_kwh": 0.0642,
      "wacc": 0.078,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 112.56,
      "electricity": 5.41,
      "site_grid": 8.14,
      "operations": 32.46,
      "total": 158.57,
      "electricity_usd_2026_kwh": 0.0642,
      "wacc": 0.078,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.11,
      "electricity": 1.1,
      "site_grid": 1.47,
      "operations": 3.38,
      "total": 24.06,
      "electricity_usd_2026_kwh": 0.106,
      "wacc": 0.0618,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.77,
      "electricity": 1.41,
      "site_grid": 1.48,
      "operations": 6.03,
      "total": 31.69,
      "electricity_usd_2026_kwh": 0.106,
      "wacc": 0.0618,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.8,
      "electricity": 2.98,
      "site_grid": 3.14,
      "operations": 7.83,
      "total": 52.75,
      "electricity_usd_2026_kwh": 0.106,
      "wacc": 0.0618,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.79,
      "electricity": 3.81,
      "site_grid": 3.17,
      "operations": 14.13,
      "total": 69.91,
      "electricity_usd_2026_kwh": 0.106,
      "wacc": 0.0618,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.84,
      "electricity": 7.03,
      "site_grid": 6.95,
      "operations": 18.61,
      "total": 118.43,
      "electricity_usd_2026_kwh": 0.106,
      "wacc": 0.0618,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2010,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.95,
      "electricity": 8.97,
      "site_grid": 7.02,
      "operations": 33.96,
      "total": 157.9,
      "electricity_usd_2026_kwh": 0.106,
      "wacc": 0.0618,
      "construction_real_factor": 0.79525,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.96,
      "electricity": 1.11,
      "site_grid": 1.4,
      "operations": 3.38,
      "total": 23.86,
      "electricity_usd_2026_kwh": 0.1072,
      "wacc": 0.0575,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.59,
      "electricity": 1.42,
      "site_grid": 1.43,
      "operations": 6.03,
      "total": 31.47,
      "electricity_usd_2026_kwh": 0.1072,
      "wacc": 0.0575,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.49,
      "electricity": 3.02,
      "site_grid": 3.01,
      "operations": 7.83,
      "total": 52.34,
      "electricity_usd_2026_kwh": 0.1072,
      "wacc": 0.0575,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.4,
      "electricity": 3.85,
      "site_grid": 3.06,
      "operations": 14.13,
      "total": 69.45,
      "electricity_usd_2026_kwh": 0.1072,
      "wacc": 0.0575,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.15,
      "electricity": 7.11,
      "site_grid": 6.65,
      "operations": 18.61,
      "total": 117.53,
      "electricity_usd_2026_kwh": 0.1072,
      "wacc": 0.0575,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2011,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.09,
      "electricity": 9.08,
      "site_grid": 6.76,
      "operations": 33.96,
      "total": 156.88,
      "electricity_usd_2026_kwh": 0.1072,
      "wacc": 0.0575,
      "construction_real_factor": 0.78459,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.64,
      "electricity": 1.13,
      "site_grid": 1.32,
      "operations": 3.38,
      "total": 23.46,
      "electricity_usd_2026_kwh": 0.1084,
      "wacc": 0.0477,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.18,
      "electricity": 1.44,
      "site_grid": 1.36,
      "operations": 6.03,
      "total": 31.01,
      "electricity_usd_2026_kwh": 0.1084,
      "wacc": 0.0477,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.79,
      "electricity": 3.05,
      "site_grid": 2.82,
      "operations": 7.83,
      "total": 51.49,
      "electricity_usd_2026_kwh": 0.1084,
      "wacc": 0.0477,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.53,
      "electricity": 3.9,
      "site_grid": 2.91,
      "operations": 14.13,
      "total": 68.47,
      "electricity_usd_2026_kwh": 0.1084,
      "wacc": 0.0477,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.6,
      "electricity": 7.19,
      "site_grid": 6.25,
      "operations": 18.61,
      "total": 115.65,
      "electricity_usd_2026_kwh": 0.1084,
      "wacc": 0.0477,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2012,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.15,
      "electricity": 9.18,
      "site_grid": 6.43,
      "operations": 33.96,
      "total": 154.72,
      "electricity_usd_2026_kwh": 0.1084,
      "wacc": 0.0477,
      "construction_real_factor": 0.7887,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.82,
      "electricity": 1.13,
      "site_grid": 1.38,
      "operations": 3.38,
      "total": 23.71,
      "electricity_usd_2026_kwh": 0.1084,
      "wacc": 0.0532,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.41,
      "electricity": 1.44,
      "site_grid": 1.41,
      "operations": 6.03,
      "total": 31.29,
      "electricity_usd_2026_kwh": 0.1084,
      "wacc": 0.0532,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.18,
      "electricity": 3.05,
      "site_grid": 2.96,
      "operations": 7.83,
      "total": 52.02,
      "electricity_usd_2026_kwh": 0.1084,
      "wacc": 0.0532,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.02,
      "electricity": 3.9,
      "site_grid": 3.02,
      "operations": 14.13,
      "total": 69.07,
      "electricity_usd_2026_kwh": 0.1084,
      "wacc": 0.0532,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.46,
      "electricity": 7.19,
      "site_grid": 6.55,
      "operations": 18.61,
      "total": 116.81,
      "electricity_usd_2026_kwh": 0.1084,
      "wacc": 0.0532,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2013,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.23,
      "electricity": 9.18,
      "site_grid": 6.69,
      "operations": 33.96,
      "total": 156.06,
      "electricity_usd_2026_kwh": 0.1084,
      "wacc": 0.0532,
      "construction_real_factor": 0.79534,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.88,
      "electricity": 1.14,
      "site_grid": 1.42,
      "operations": 3.38,
      "total": 23.83,
      "electricity_usd_2026_kwh": 0.1096,
      "wacc": 0.0551,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.49,
      "electricity": 1.45,
      "site_grid": 1.45,
      "operations": 6.03,
      "total": 31.42,
      "electricity_usd_2026_kwh": 0.1096,
      "wacc": 0.0551,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.31,
      "electricity": 3.09,
      "site_grid": 3.05,
      "operations": 7.83,
      "total": 52.28,
      "electricity_usd_2026_kwh": 0.1096,
      "wacc": 0.0551,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.19,
      "electricity": 3.94,
      "site_grid": 3.1,
      "operations": 14.13,
      "total": 69.37,
      "electricity_usd_2026_kwh": 0.1096,
      "wacc": 0.0551,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.77,
      "electricity": 7.27,
      "site_grid": 6.74,
      "operations": 18.61,
      "total": 117.38,
      "electricity_usd_2026_kwh": 0.1096,
      "wacc": 0.0551,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2014,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.61,
      "electricity": 9.28,
      "site_grid": 6.87,
      "operations": 33.96,
      "total": 156.71,
      "electricity_usd_2026_kwh": 0.1096,
      "wacc": 0.0551,
      "construction_real_factor": 0.80787,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.75,
      "electricity": 1.15,
      "site_grid": 1.41,
      "operations": 3.38,
      "total": 23.69,
      "electricity_usd_2026_kwh": 0.1108,
      "wacc": 0.0511,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.32,
      "electricity": 1.47,
      "site_grid": 1.44,
      "operations": 6.03,
      "total": 31.26,
      "electricity_usd_2026_kwh": 0.1108,
      "wacc": 0.0511,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.03,
      "electricity": 3.12,
      "site_grid": 3.02,
      "operations": 7.83,
      "total": 51.99,
      "electricity_usd_2026_kwh": 0.1108,
      "wacc": 0.0511,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.83,
      "electricity": 3.98,
      "site_grid": 3.09,
      "operations": 14.13,
      "total": 69.04,
      "electricity_usd_2026_kwh": 0.1108,
      "wacc": 0.0511,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.13,
      "electricity": 7.35,
      "site_grid": 6.67,
      "operations": 18.61,
      "total": 116.76,
      "electricity_usd_2026_kwh": 0.1108,
      "wacc": 0.0511,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2015,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.81,
      "electricity": 9.38,
      "site_grid": 6.84,
      "operations": 33.96,
      "total": 155.99,
      "electricity_usd_2026_kwh": 0.1108,
      "wacc": 0.0511,
      "construction_real_factor": 0.82253,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.65,
      "electricity": 1.16,
      "site_grid": 1.37,
      "operations": 3.38,
      "total": 23.56,
      "electricity_usd_2026_kwh": 0.112,
      "wacc": 0.0481,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.2,
      "electricity": 1.49,
      "site_grid": 1.41,
      "operations": 6.03,
      "total": 31.12,
      "electricity_usd_2026_kwh": 0.112,
      "wacc": 0.0481,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.81,
      "electricity": 3.15,
      "site_grid": 2.93,
      "operations": 7.83,
      "total": 51.73,
      "electricity_usd_2026_kwh": 0.112,
      "wacc": 0.0481,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.56,
      "electricity": 4.03,
      "site_grid": 3.02,
      "operations": 14.13,
      "total": 68.74,
      "electricity_usd_2026_kwh": 0.112,
      "wacc": 0.0481,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.65,
      "electricity": 7.43,
      "site_grid": 6.49,
      "operations": 18.61,
      "total": 116.18,
      "electricity_usd_2026_kwh": 0.112,
      "wacc": 0.0481,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2016,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.21,
      "electricity": 9.48,
      "site_grid": 6.68,
      "operations": 33.96,
      "total": 155.34,
      "electricity_usd_2026_kwh": 0.112,
      "wacc": 0.0481,
      "construction_real_factor": 0.81728,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.81,
      "electricity": 1.18,
      "site_grid": 1.42,
      "operations": 3.38,
      "total": 23.79,
      "electricity_usd_2026_kwh": 0.1132,
      "wacc": 0.053,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.4,
      "electricity": 1.5,
      "site_grid": 1.45,
      "operations": 6.03,
      "total": 31.39,
      "electricity_usd_2026_kwh": 0.1132,
      "wacc": 0.053,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.16,
      "electricity": 3.19,
      "site_grid": 3.05,
      "operations": 7.83,
      "total": 52.23,
      "electricity_usd_2026_kwh": 0.1132,
      "wacc": 0.053,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.0,
      "electricity": 4.07,
      "site_grid": 3.12,
      "operations": 14.13,
      "total": 69.32,
      "electricity_usd_2026_kwh": 0.1132,
      "wacc": 0.053,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.43,
      "electricity": 7.51,
      "site_grid": 6.74,
      "operations": 18.61,
      "total": 117.29,
      "electricity_usd_2026_kwh": 0.1132,
      "wacc": 0.053,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2017,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 106.19,
      "electricity": 9.59,
      "site_grid": 6.89,
      "operations": 33.96,
      "total": 156.62,
      "electricity_usd_2026_kwh": 0.1132,
      "wacc": 0.053,
      "construction_real_factor": 0.82039,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.01,
      "electricity": 1.19,
      "site_grid": 1.51,
      "operations": 3.38,
      "total": 24.09,
      "electricity_usd_2026_kwh": 0.1144,
      "wacc": 0.0588,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.65,
      "electricity": 1.52,
      "site_grid": 1.54,
      "operations": 6.03,
      "total": 31.73,
      "electricity_usd_2026_kwh": 0.1144,
      "wacc": 0.0588,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.58,
      "electricity": 3.22,
      "site_grid": 3.24,
      "operations": 7.83,
      "total": 52.88,
      "electricity_usd_2026_kwh": 0.1144,
      "wacc": 0.0588,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.52,
      "electricity": 4.11,
      "site_grid": 3.29,
      "operations": 14.13,
      "total": 70.06,
      "electricity_usd_2026_kwh": 0.1144,
      "wacc": 0.0588,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.36,
      "electricity": 7.59,
      "site_grid": 7.18,
      "operations": 18.61,
      "total": 118.73,
      "electricity_usd_2026_kwh": 0.1144,
      "wacc": 0.0588,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2018,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.34,
      "electricity": 9.69,
      "site_grid": 7.28,
      "operations": 33.96,
      "total": 158.27,
      "electricity_usd_2026_kwh": 0.1144,
      "wacc": 0.0588,
      "construction_real_factor": 0.8388,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.75,
      "electricity": 1.2,
      "site_grid": 1.49,
      "operations": 3.38,
      "total": 23.83,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0511,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.32,
      "electricity": 1.53,
      "site_grid": 1.53,
      "operations": 6.03,
      "total": 31.42,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0511,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.03,
      "electricity": 3.26,
      "site_grid": 3.2,
      "operations": 7.83,
      "total": 52.31,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0511,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.83,
      "electricity": 4.16,
      "site_grid": 3.28,
      "operations": 14.13,
      "total": 69.4,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0511,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 84.13,
      "electricity": 7.67,
      "site_grid": 7.08,
      "operations": 18.61,
      "total": 117.49,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0511,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2019,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 105.82,
      "electricity": 9.79,
      "site_grid": 7.26,
      "operations": 33.96,
      "total": 156.82,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0511,
      "construction_real_factor": 0.87274,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.38,
      "electricity": 1.2,
      "site_grid": 1.4,
      "operations": 3.38,
      "total": 23.37,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0386,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 21.8,
      "electricity": 1.53,
      "site_grid": 1.45,
      "operations": 6.03,
      "total": 30.82,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0386,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.24,
      "electricity": 3.26,
      "site_grid": 3.01,
      "operations": 7.83,
      "total": 51.33,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0386,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 46.71,
      "electricity": 4.16,
      "site_grid": 3.11,
      "operations": 14.13,
      "total": 68.11,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0386,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 82.38,
      "electricity": 7.67,
      "site_grid": 6.65,
      "operations": 18.61,
      "total": 115.31,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0386,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2020,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 103.35,
      "electricity": 9.79,
      "site_grid": 6.87,
      "operations": 33.96,
      "total": 153.96,
      "electricity_usd_2026_kwh": 0.1156,
      "wacc": 0.0386,
      "construction_real_factor": 0.88762,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 17.52,
      "electricity": 1.21,
      "site_grid": 1.45,
      "operations": 3.38,
      "total": 23.57,
      "electricity_usd_2026_kwh": 0.1168,
      "wacc": 0.0442,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.03,
      "electricity": 1.55,
      "site_grid": 1.5,
      "operations": 6.03,
      "total": 31.12,
      "electricity_usd_2026_kwh": 0.1168,
      "wacc": 0.0442,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 37.53,
      "electricity": 3.29,
      "site_grid": 3.11,
      "operations": 7.83,
      "total": 51.77,
      "electricity_usd_2026_kwh": 0.1168,
      "wacc": 0.0442,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 47.21,
      "electricity": 4.2,
      "site_grid": 3.22,
      "operations": 14.13,
      "total": 68.77,
      "electricity_usd_2026_kwh": 0.1168,
      "wacc": 0.0442,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 83.04,
      "electricity": 7.75,
      "site_grid": 6.89,
      "operations": 18.61,
      "total": 116.29,
      "electricity_usd_2026_kwh": 0.1168,
      "wacc": 0.0442,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2021,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 104.44,
      "electricity": 9.89,
      "site_grid": 7.13,
      "operations": 33.96,
      "total": 155.42,
      "electricity_usd_2026_kwh": 0.1168,
      "wacc": 0.0442,
      "construction_real_factor": 0.8921,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.02,
      "electricity": 1.23,
      "site_grid": 1.83,
      "operations": 3.38,
      "total": 24.46,
      "electricity_usd_2026_kwh": 0.118,
      "wacc": 0.0592,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 22.66,
      "electricity": 1.57,
      "site_grid": 1.85,
      "operations": 6.03,
      "total": 32.11,
      "electricity_usd_2026_kwh": 0.118,
      "wacc": 0.0592,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 38.61,
      "electricity": 3.32,
      "site_grid": 3.92,
      "operations": 7.83,
      "total": 53.68,
      "electricity_usd_2026_kwh": 0.118,
      "wacc": 0.0592,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 48.56,
      "electricity": 4.24,
      "site_grid": 3.97,
      "operations": 14.13,
      "total": 70.91,
      "electricity_usd_2026_kwh": 0.118,
      "wacc": 0.0592,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 85.42,
      "electricity": 7.83,
      "site_grid": 8.67,
      "operations": 18.61,
      "total": 120.53,
      "electricity_usd_2026_kwh": 0.118,
      "wacc": 0.0592,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2022,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 107.42,
      "electricity": 9.99,
      "site_grid": 8.79,
      "operations": 33.96,
      "total": 160.16,
      "electricity_usd_2026_kwh": 0.118,
      "wacc": 0.0592,
      "construction_real_factor": 1.0102,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.36,
      "electricity": 1.24,
      "site_grid": 2.02,
      "operations": 3.38,
      "total": 25.0,
      "electricity_usd_2026_kwh": 0.1192,
      "wacc": 0.0693,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.09,
      "electricity": 1.58,
      "site_grid": 2.02,
      "operations": 6.03,
      "total": 32.72,
      "electricity_usd_2026_kwh": 0.1192,
      "wacc": 0.0693,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.34,
      "electricity": 3.36,
      "site_grid": 4.33,
      "operations": 7.83,
      "total": 54.85,
      "electricity_usd_2026_kwh": 0.1192,
      "wacc": 0.0693,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.47,
      "electricity": 4.29,
      "site_grid": 4.33,
      "operations": 14.13,
      "total": 72.22,
      "electricity_usd_2026_kwh": 0.1192,
      "wacc": 0.0693,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.03,
      "electricity": 7.91,
      "site_grid": 9.58,
      "operations": 18.61,
      "total": 123.13,
      "electricity_usd_2026_kwh": 0.1192,
      "wacc": 0.0693,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2023,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.44,
      "electricity": 10.1,
      "site_grid": 9.59,
      "operations": 33.96,
      "total": 163.07,
      "electricity_usd_2026_kwh": 0.1192,
      "wacc": 0.0693,
      "construction_real_factor": 1.04368,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.44,
      "electricity": 1.25,
      "site_grid": 1.99,
      "operations": 3.38,
      "total": 25.07,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0718,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.19,
      "electricity": 1.6,
      "site_grid": 1.98,
      "operations": 6.03,
      "total": 32.8,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0718,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.52,
      "electricity": 3.39,
      "site_grid": 4.26,
      "operations": 7.83,
      "total": 55.0,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0718,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.69,
      "electricity": 4.33,
      "site_grid": 4.25,
      "operations": 14.13,
      "total": 72.41,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0718,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.43,
      "electricity": 7.99,
      "site_grid": 9.42,
      "operations": 18.61,
      "total": 123.45,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0718,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2024,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 109.93,
      "electricity": 10.2,
      "site_grid": 9.4,
      "operations": 33.96,
      "total": 163.49,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0718,
      "construction_real_factor": 1.01036,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.47,
      "electricity": 1.25,
      "site_grid": 1.97,
      "operations": 3.38,
      "total": 25.08,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0726,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.23,
      "electricity": 1.6,
      "site_grid": 1.97,
      "operations": 6.03,
      "total": 32.82,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0726,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.58,
      "electricity": 3.39,
      "site_grid": 4.23,
      "operations": 7.83,
      "total": 55.03,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0726,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.77,
      "electricity": 4.33,
      "site_grid": 4.22,
      "operations": 14.13,
      "total": 72.45,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0726,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.56,
      "electricity": 7.99,
      "site_grid": 9.35,
      "operations": 18.61,
      "total": 123.52,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0726,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2025,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.1,
      "electricity": 10.2,
      "site_grid": 9.33,
      "operations": 33.96,
      "total": 163.58,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.0726,
      "construction_real_factor": 0.99742,
      "power_source": "modeled regional path",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "general",
      "hardware": 18.49,
      "electricity": 1.25,
      "site_grid": 1.98,
      "operations": 3.38,
      "total": 25.1,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.073,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "general",
      "hardware": 23.24,
      "electricity": 1.6,
      "site_grid": 1.98,
      "operations": 6.03,
      "total": 32.85,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.073,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "long_context",
      "hardware": 39.61,
      "electricity": 3.39,
      "site_grid": 4.25,
      "operations": 7.83,
      "total": 55.08,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.073,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "long_context",
      "hardware": 49.8,
      "electricity": 4.33,
      "site_grid": 4.23,
      "operations": 14.13,
      "total": 72.5,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.073,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "datacenter_100mw",
      "workload": "agentic",
      "hardware": 87.63,
      "electricity": 7.99,
      "site_grid": 9.4,
      "operations": 18.61,
      "total": 123.63,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.073,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    },
    {
      "year": 2026,
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "scale": "onprem_250kw",
      "workload": "agentic",
      "hardware": 110.18,
      "electricity": 10.2,
      "site_grid": 9.37,
      "operations": 33.96,
      "total": 163.7,
      "electricity_usd_2026_kwh": 0.1204,
      "wacc": 0.073,
      "construction_real_factor": 1.0,
      "power_source": "current index input",
      "evidence_grade": "B"
    }
  ]
}