  "version": "2026-07",
  "date_modified": "2026-07-27",
  "output_currency": "USD",
  "eur_usd": 1.1467,
  "workloads": {
    "general": {
      "label": "General inference",
      "unit": "$/million output tokens",
      "output_tps": 3683,
      "it_kw": 98,
      "utilization": 0.7,
      "extra_opex_m": 0.02
    },
    "long_context": {
      "label": "Long-context analysis",
      "unit": "$/million output tokens",
      "output_tps": 1719,
      "it_kw": 124,
      "utilization": 0.7,
      "extra_opex_m": 0.06
    },
    "agentic": {
      "label": "Agentic engineering",
      "unit": "$/million output tokens",
      "output_tps": 777,
      "it_kw": 132,
      "utilization": 0.7,
      "extra_opex_m": 0.1
    }
  },
  "scales": {
    "datacenter_100mw": {
      "label": "100 MW data center",
      "description": "100 MW utility-connected data center"
    },
    "onprem_250kw": {
      "label": "On-prem solution (250 kW)",
      "description": "On-premises deployment with a 250 kW connection envelope"
    }
  },
  "calibration": {
    "output_usd_per_m": 15.0,
    "cache_miss_input_usd_per_m": 3.0,
    "cache_hit_input_usd_per_m": 0.3,
    "cache_hit_rate": 0.9,
    "general_input_output_ratio": 4.0,
    "maximum_subsidy_share": 0.25,
    "source": "https://www.kimi.com/blog/kimi-k3",
    "blended_input_usd_per_m": 0.57,
    "api_revenue_usd_per_m_output": 17.28,
    "maximum_production_cost_usd_per_m_output": 23.04,
    "uncalibrated_china_cost_usd_per_m_output": 94.28,
    "throughput_multiplier": 4.092,
    "baseline_output_tps": {
      "general": 900,
      "long_context": 420,
      "agentic": 190
    },
    "calibrated_output_tps": {
      "general": 3683,
      "long_context": 1719,
      "agentic": 777
    },
    "calibrated_china_cost_usd_per_m_output": 23.04,
    "interpretation": "General inference is price-implied; long-context and agentic throughputs apply the same K3 efficiency multiplier."
  },
  "countries": [
    {
      "code": "AT",
      "country": "Austria",
      "group": "EU",
      "electricity_eur_kwh": 0.1986,
      "pue": 1.13,
      "landed_hardware_multiplier": 1.03,
      "hurdle_rate": 0.07,
      "facility_capex_eur_m": 0.72,
      "connection_capex_eur_m": 0.3,
      "operations_labour_multiplier": 1.05,
      "availability": 0.994,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.7,
            "electricity": 2.13,
            "site_grid": 1.9,
            "operations": 3.32,
            "total": 25.06,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 37.93,
            "electricity": 5.79,
            "site_grid": 4.08,
            "operations": 7.7,
            "total": 55.49,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 83.92,
            "electricity": 13.63,
            "site_grid": 9.02,
            "operations": 18.32,
            "total": 124.89,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 22.28,
            "electricity": 2.73,
            "site_grid": 1.82,
            "operations": 6.48,
            "total": 33.31,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 47.73,
            "electricity": 7.41,
            "site_grid": 3.9,
            "operations": 15.1,
            "total": 74.14,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 105.59,
            "electricity": 17.45,
            "site_grid": 8.64,
            "operations": 36.09,
            "total": 167.77,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.13,
          "electricity_eur_kwh": 0.1986,
          "electricity_usd_kwh": 0.22773462,
          "utilization": 0.7,
          "availability": 0.994,
          "facility_capex_eur_m": 0.72,
          "connection_capex_eur_m": 0.3
        },
        "datacenter_100mw": {
          "service_units": 640.2,
          "connection_mw": 100,
          "commissioned_it_mw": 90.9,
          "pue": 1.0999999999999999,
          "electricity_eur_kwh": 0.182712,
          "electricity_usd_kwh": 0.20951585040000004,
          "utilization": 0.8,
          "availability": 0.9976,
          "facility_capex_eur_m": 869.9640535115738,
          "connection_capex_eur_m": 65.91363259836707,
          "construction_eur_m_per_it_mw": 9.56960458862731
        }
      }
    },
    {
      "code": "BE",
      "country": "Belgium",
      "group": "EU",
      "electricity_eur_kwh": 0.1866,
      "pue": 1.12,
      "landed_hardware_multiplier": 1.03,
      "hurdle_rate": 0.072,
      "facility_capex_eur_m": 0.76,
      "connection_capex_eur_m": 0.34,
      "operations_labour_multiplier": 1.05,
      "availability": 0.994,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.77,
            "electricity": 1.99,
            "site_grid": 2.0,
            "operations": 3.31,
            "total": 25.07,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 38.07,
            "electricity": 5.39,
            "site_grid": 4.29,
            "operations": 7.69,
            "total": 55.43,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 84.23,
            "electricity": 12.69,
            "site_grid": 9.49,
            "operations": 18.29,
            "total": 124.7,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 22.36,
            "electricity": 2.55,
            "site_grid": 1.99,
            "operations": 6.48,
            "total": 33.37,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 47.9,
            "electricity": 6.9,
            "site_grid": 4.26,
            "operations": 15.1,
            "total": 74.16,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 105.98,
            "electricity": 16.25,
            "site_grid": 9.41,
            "operations": 36.09,
            "total": 167.73,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.12,
          "electricity_eur_kwh": 0.1866,
          "electricity_usd_kwh": 0.21397422,
          "utilization": 0.7,
          "availability": 0.994,
          "facility_capex_eur_m": 0.76,
          "connection_capex_eur_m": 0.34
        },
        "datacenter_100mw": {
          "service_units": 646.1,
          "connection_mw": 100,
          "commissioned_it_mw": 91.7,
          "pue": 1.09,
          "electricity_eur_kwh": 0.171672,
          "electricity_usd_kwh": 0.1968562824,
          "utilization": 0.8,
          "availability": 0.9976,
          "facility_capex_eur_m": 906.8932153832784,
          "connection_capex_eur_m": 74.70211694481601,
          "construction_eur_m_per_it_mw": 9.885136047677737
        }
      }
    },
    {
      "code": "BG",
      "country": "Bulgaria",
      "group": "EU",
      "electricity_eur_kwh": 0.1413,
      "pue": 1.17,
      "landed_hardware_multiplier": 1.08,
      "hurdle_rate": 0.095,
      "facility_capex_eur_m": 0.55,
      "connection_capex_eur_m": 0.24,
      "operations_labour_multiplier": 0.62,
      "availability": 0.988,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 19.47,
            "electricity": 1.58,
            "site_grid": 1.89,
            "operations": 3.26,
            "total": 26.2,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 41.72,
            "electricity": 4.28,
            "site_grid": 4.06,
            "operations": 7.57,
            "total": 57.62,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 92.29,
            "electricity": 10.07,
            "site_grid": 8.98,
            "operations": 18.04,
            "total": 129.38,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 24.58,
            "electricity": 2.03,
            "site_grid": 1.61,
            "operations": 5.45,
            "total": 33.67,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 52.66,
            "electricity": 5.49,
            "site_grid": 3.46,
            "operations": 12.89,
            "total": 74.51,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 116.51,
            "electricity": 12.94,
            "site_grid": 7.65,
            "operations": 31.23,
            "total": 168.33,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.17,
          "electricity_eur_kwh": 0.1413,
          "electricity_usd_kwh": 0.16202871000000002,
          "utilization": 0.7,
          "availability": 0.988,
          "facility_capex_eur_m": 0.55,
          "connection_capex_eur_m": 0.24
        },
        "datacenter_100mw": {
          "service_units": 617.7,
          "connection_mw": 100,
          "commissioned_it_mw": 87.7,
          "pue": 1.14,
          "electricity_eur_kwh": 0.129996,
          "electricity_usd_kwh": 0.1490664132,
          "utilization": 0.8,
          "availability": 0.9952,
          "facility_capex_eur_m": 714.1792991841969,
          "connection_capex_eur_m": 52.73090607869366,
          "construction_eur_m_per_it_mw": 8.141644010699844
        }
      }
    },
    {
      "code": "HR",
      "country": "Croatia",
      "group": "EU",
      "electricity_eur_kwh": 0.1548,
      "pue": 1.18,
      "landed_hardware_multiplier": 1.08,
      "hurdle_rate": 0.09,
      "facility_capex_eur_m": 0.58,
      "connection_capex_eur_m": 0.25,
      "operations_labour_multiplier": 0.72,
      "availability": 0.989,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 19.29,
            "electricity": 1.74,
            "site_grid": 1.9,
            "operations": 3.31,
            "total": 26.24,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 41.33,
            "electricity": 4.72,
            "site_grid": 4.07,
            "operations": 7.68,
            "total": 57.8,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 91.43,
            "electricity": 11.13,
            "site_grid": 9.0,
            "operations": 18.29,
            "total": 129.85,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 24.34,
            "electricity": 2.24,
            "site_grid": 1.65,
            "operations": 5.73,
            "total": 33.95,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 52.15,
            "electricity": 6.06,
            "site_grid": 3.54,
            "operations": 13.49,
            "total": 75.24,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 115.36,
            "electricity": 14.28,
            "site_grid": 7.84,
            "operations": 32.55,
            "total": 170.03,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.18,
          "electricity_eur_kwh": 0.1548,
          "electricity_usd_kwh": 0.17750916,
          "utilization": 0.7,
          "availability": 0.989,
          "facility_capex_eur_m": 0.58,
          "connection_capex_eur_m": 0.25
        },
        "datacenter_100mw": {
          "service_units": 612.4,
          "connection_mw": 100,
          "commissioned_it_mw": 87.0,
          "pue": 1.15,
          "electricity_eur_kwh": 0.142416,
          "electricity_usd_kwh": 0.1633084272,
          "utilization": 0.8,
          "availability": 0.9956,
          "facility_capex_eur_m": 730.8924088047808,
          "connection_capex_eur_m": 54.92802716530589,
          "construction_eur_m_per_it_mw": 8.405262701254978
        }
      }
    },
    {
      "code": "CY",
      "country": "Cyprus",
      "group": "EU",
      "electricity_eur_kwh": 0.2429,
      "pue": 1.25,
      "landed_hardware_multiplier": 1.12,
      "hurdle_rate": 0.09,
      "facility_capex_eur_m": 0.7,
      "connection_capex_eur_m": 0.38,
      "operations_labour_multiplier": 0.8,
      "availability": 0.986,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 20.03,
            "electricity": 2.9,
            "site_grid": 2.19,
            "operations": 3.49,
            "total": 28.61,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 42.91,
            "electricity": 7.87,
            "site_grid": 4.68,
            "operations": 8.06,
            "total": 63.53,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 94.93,
            "electricity": 18.54,
            "site_grid": 10.36,
            "operations": 19.13,
            "total": 142.98,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 25.32,
            "electricity": 3.73,
            "site_grid": 2.16,
            "operations": 6.1,
            "total": 37.3,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 54.24,
            "electricity": 10.11,
            "site_grid": 4.62,
            "operations": 14.29,
            "total": 83.26,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 120.0,
            "electricity": 23.8,
            "site_grid": 10.23,
            "operations": 34.34,
            "total": 188.37,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.25,
          "electricity_eur_kwh": 0.2429,
          "electricity_usd_kwh": 0.27853343,
          "utilization": 0.7,
          "availability": 0.986,
          "facility_capex_eur_m": 0.7,
          "connection_capex_eur_m": 0.38
        },
        "datacenter_100mw": {
          "service_units": 577.2,
          "connection_mw": 100,
          "commissioned_it_mw": 82.0,
          "pue": 1.22,
          "electricity_eur_kwh": 0.22346800000000003,
          "electricity_usd_kwh": 0.25625075560000005,
          "utilization": 0.8,
          "availability": 0.9944,
          "facility_capex_eur_m": 771.2470018885135,
          "connection_capex_eur_m": 83.49060129126495,
          "construction_eur_m_per_it_mw": 9.409213423039864
        }
      }
    },
    {
      "code": "CZ",
      "country": "Czechia",
      "group": "EU",
      "electricity_eur_kwh": 0.1825,
      "pue": 1.13,
      "landed_hardware_multiplier": 1.05,
      "hurdle_rate": 0.08,
      "facility_capex_eur_m": 0.6,
      "connection_capex_eur_m": 0.28,
      "operations_labour_multiplier": 0.78,
      "availability": 0.992,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 18.4,
            "electricity": 1.96,
            "site_grid": 1.83,
            "operations": 3.24,
            "total": 25.43,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 39.41,
            "electricity": 5.32,
            "site_grid": 3.91,
            "operations": 7.53,
            "total": 56.18,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 87.2,
            "electricity": 12.53,
            "site_grid": 8.65,
            "operations": 17.95,
            "total": 126.33,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 23.17,
            "electricity": 2.52,
            "site_grid": 1.66,
            "operations": 5.79,
            "total": 33.14,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 49.65,
            "electricity": 6.82,
            "site_grid": 3.56,
            "operations": 13.62,
            "total": 73.64,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 109.83,
            "electricity": 16.07,
            "site_grid": 7.87,
            "operations": 32.82,
            "total": 166.59,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.13,
          "electricity_eur_kwh": 0.1825,
          "electricity_usd_kwh": 0.20927275,
          "utilization": 0.7,
          "availability": 0.992,
          "facility_capex_eur_m": 0.6,
          "connection_capex_eur_m": 0.28
        },
        "datacenter_100mw": {
          "service_units": 640.2,
          "connection_mw": 100,
          "commissioned_it_mw": 90.9,
          "pue": 1.0999999999999999,
          "electricity_eur_kwh": 0.1679,
          "electricity_usd_kwh": 0.19253093,
          "utilization": 0.8,
          "availability": 0.9968,
          "facility_capex_eur_m": 779.8167521300101,
          "connection_capex_eur_m": 61.5193904251426,
          "construction_eur_m_per_it_mw": 8.57798427343011
        }
      }
    },
    {
      "code": "DK",
      "country": "Denmark",
      "group": "EU",
      "electricity_eur_kwh": 0.1216,
      "pue": 1.1,
      "landed_hardware_multiplier": 1.01,
      "hurdle_rate": 0.065,
      "facility_capex_eur_m": 0.72,
      "connection_capex_eur_m": 0.35,
      "operations_labour_multiplier": 1.08,
      "availability": 0.996,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.19,
            "electricity": 1.27,
            "site_grid": 1.86,
            "operations": 3.27,
            "total": 23.58,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 36.82,
            "electricity": 3.44,
            "site_grid": 3.97,
            "operations": 7.58,
            "total": 51.82,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 81.47,
            "electricity": 8.11,
            "site_grid": 8.79,
            "operations": 18.05,
            "total": 116.43,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 21.6,
            "electricity": 1.63,
            "site_grid": 1.86,
            "operations": 6.49,
            "total": 31.57,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 46.28,
            "electricity": 4.41,
            "site_grid": 3.98,
            "operations": 15.12,
            "total": 69.78,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 102.39,
            "electricity": 10.38,
            "site_grid": 8.8,
            "operations": 36.13,
            "total": 157.7,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.1,
          "electricity_eur_kwh": 0.1216,
          "electricity_usd_kwh": 0.13943872000000002,
          "utilization": 0.7,
          "availability": 0.996,
          "facility_capex_eur_m": 0.72,
          "connection_capex_eur_m": 0.35
        },
        "datacenter_100mw": {
          "service_units": 658.2,
          "connection_mw": 100,
          "commissioned_it_mw": 93.5,
          "pue": 1.07,
          "electricity_eur_kwh": 0.111872,
          "electricity_usd_kwh": 0.1282836224,
          "utilization": 0.8,
          "availability": 0.9984,
          "facility_capex_eur_m": 894.3555690305897,
          "connection_capex_eur_m": 76.89923803142824,
          "construction_eur_m_per_it_mw": 9.56960458862731
        }
      }
    },
    {
      "code": "EE",
      "country": "Estonia",
      "group": "EU",
      "electricity_eur_kwh": 0.141,
      "pue": 1.1,
      "landed_hardware_multiplier": 1.06,
      "hurdle_rate": 0.08,
      "facility_capex_eur_m": 0.57,
      "connection_capex_eur_m": 0.27,
      "operations_labour_multiplier": 0.75,
      "availability": 0.991,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 18.58,
            "electricity": 1.48,
            "site_grid": 1.77,
            "operations": 3.24,
            "total": 25.06,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 39.8,
            "electricity": 4.0,
            "site_grid": 3.79,
            "operations": 7.52,
            "total": 55.11,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 88.06,
            "electricity": 9.42,
            "site_grid": 8.37,
            "operations": 17.94,
            "total": 123.8,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 23.42,
            "electricity": 1.9,
            "site_grid": 1.59,
            "operations": 5.74,
            "total": 32.64,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 50.17,
            "electricity": 5.14,
            "site_grid": 3.4,
            "operations": 13.51,
            "total": 72.22,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 110.99,
            "electricity": 12.1,
            "site_grid": 7.52,
            "operations": 32.6,
            "total": 163.21,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.1,
          "electricity_eur_kwh": 0.141,
          "electricity_usd_kwh": 0.1616847,
          "utilization": 0.7,
          "availability": 0.991,
          "facility_capex_eur_m": 0.57,
          "connection_capex_eur_m": 0.27
        },
        "datacenter_100mw": {
          "service_units": 658.2,
          "connection_mw": 100,
          "commissioned_it_mw": 93.5,
          "pue": 1.07,
          "electricity_eur_kwh": 0.12972,
          "electricity_usd_kwh": 0.148749924,
          "utilization": 0.8,
          "availability": 0.9964,
          "facility_capex_eur_m": 777.38405972858,
          "connection_capex_eur_m": 59.32226933853037,
          "construction_eur_m_per_it_mw": 8.318009439095807
        }
      }
    },
    {
      "code": "FI",
      "country": "Finland",
      "group": "EU",
      "electricity_eur_kwh": 0.0748,
      "pue": 1.08,
      "landed_hardware_multiplier": 1.01,
      "hurdle_rate": 0.062,
      "facility_capex_eur_m": 0.61,
      "connection_capex_eur_m": 0.27,
      "operations_labour_multiplier": 0.95,
      "availability": 0.996,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.09,
            "electricity": 0.78,
            "site_grid": 1.63,
            "operations": 3.2,
            "total": 22.71,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 36.62,
            "electricity": 2.12,
            "site_grid": 3.49,
            "operations": 7.45,
            "total": 49.68,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 81.02,
            "electricity": 4.99,
            "site_grid": 7.73,
            "operations": 17.77,
            "total": 111.5,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 21.48,
            "electricity": 0.98,
            "site_grid": 1.5,
            "operations": 6.12,
            "total": 30.09,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 46.03,
            "electricity": 2.66,
            "site_grid": 3.22,
            "operations": 14.33,
            "total": 66.23,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 101.82,
            "electricity": 6.27,
            "site_grid": 7.12,
            "operations": 34.38,
            "total": 149.6,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.08,
          "electricity_eur_kwh": 0.0748,
          "electricity_usd_kwh": 0.08577316000000001,
          "utilization": 0.7,
          "availability": 0.996,
          "facility_capex_eur_m": 0.61,
          "connection_capex_eur_m": 0.27
        },
        "datacenter_100mw": {
          "service_units": 658.2,
          "connection_mw": 100,
          "commissioned_it_mw": 93.5,
          "pue": 1.07,
          "electricity_eur_kwh": 0.068816,
          "electricity_usd_kwh": 0.0789113072,
          "utilization": 0.8,
          "availability": 0.9984,
          "facility_capex_eur_m": 809.6710640455074,
          "connection_capex_eur_m": 59.32226933853037,
          "construction_eur_m_per_it_mw": 8.66348038528693
        }
      }
    },
    {
      "code": "FR",
      "country": "France",
      "group": "EU",
      "electricity_eur_kwh": 0.1534,
      "pue": 1.13,
      "landed_hardware_multiplier": 1.02,
      "hurdle_rate": 0.068,
      "facility_capex_eur_m": 0.73,
      "connection_capex_eur_m": 0.36,
      "operations_labour_multiplier": 1.0,
      "availability": 0.995,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.46,
            "electricity": 1.65,
            "site_grid": 1.92,
            "operations": 3.27,
            "total": 24.3,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 37.41,
            "electricity": 4.47,
            "site_grid": 4.1,
            "operations": 7.59,
            "total": 53.57,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 82.77,
            "electricity": 10.52,
            "site_grid": 9.08,
            "operations": 18.08,
            "total": 120.45,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 21.96,
            "electricity": 2.11,
            "site_grid": 1.92,
            "operations": 6.3,
            "total": 32.29,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 47.04,
            "electricity": 5.72,
            "site_grid": 4.12,
            "operations": 14.71,
            "total": 71.6,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 104.08,
            "electricity": 13.47,
            "site_grid": 9.12,
            "operations": 35.23,
            "total": 161.9,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.13,
          "electricity_eur_kwh": 0.1534,
          "electricity_usd_kwh": 0.17590378,
          "utilization": 0.7,
          "availability": 0.995,
          "facility_capex_eur_m": 0.73,
          "connection_capex_eur_m": 0.36
        },
        "datacenter_100mw": {
          "service_units": 640.2,
          "connection_mw": 100,
          "commissioned_it_mw": 90.9,
          "pue": 1.0999999999999999,
          "electricity_eur_kwh": 0.141128,
          "electricity_usd_kwh": 0.16183147760000002,
          "utilization": 0.8,
          "availability": 0.998,
          "facility_capex_eur_m": 877.1937453476172,
          "connection_capex_eur_m": 79.09635911804048,
          "construction_eur_m_per_it_mw": 9.649131198823788
        }
      }
    },
    {
      "code": "DE",
      "country": "Germany",
      "group": "EU",
      "electricity_eur_kwh": 0.2264,
      "pue": 1.12,
      "landed_hardware_multiplier": 1.02,
      "hurdle_rate": 0.068,
      "facility_capex_eur_m": 0.78,
      "connection_capex_eur_m": 0.48,
      "operations_labour_multiplier": 1.08,
      "availability": 0.995,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.46,
            "electricity": 2.41,
            "site_grid": 2.03,
            "operations": 3.3,
            "total": 25.21,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 37.41,
            "electricity": 6.53,
            "site_grid": 4.35,
            "operations": 7.66,
            "total": 55.96,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 82.77,
            "electricity": 15.39,
            "site_grid": 9.63,
            "operations": 18.24,
            "total": 126.02,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 21.96,
            "electricity": 3.09,
            "site_grid": 2.22,
            "operations": 6.53,
            "total": 33.79,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 47.04,
            "electricity": 8.37,
            "site_grid": 4.77,
            "operations": 15.2,
            "total": 75.37,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 104.08,
            "electricity": 19.7,
            "site_grid": 10.55,
            "operations": 36.31,
            "total": 170.63,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.12,
          "electricity_eur_kwh": 0.2264,
          "electricity_usd_kwh": 0.25961288,
          "utilization": 0.7,
          "availability": 0.995,
          "facility_capex_eur_m": 0.78,
          "connection_capex_eur_m": 0.48
        },
        "datacenter_100mw": {
          "service_units": 646.1,
          "connection_mw": 100,
          "commissioned_it_mw": 91.7,
          "pue": 1.09,
          "electricity_eur_kwh": 0.208288,
          "electricity_usd_kwh": 0.23884384960000002,
          "utilization": 0.8,
          "availability": 0.998,
          "facility_capex_eur_m": 921.1381280338024,
          "connection_capex_eur_m": 105.46181215738731,
          "construction_eur_m_per_it_mw": 10.040405595568448
        }
      }
    },
    {
      "code": "GR",
      "country": "Greece",
      "group": "EU",
      "electricity_eur_kwh": 0.174,
      "pue": 1.21,
      "landed_hardware_multiplier": 1.08,
      "hurdle_rate": 0.09,
      "facility_capex_eur_m": 0.62,
      "connection_capex_eur_m": 0.27,
      "operations_labour_multiplier": 0.72,
      "availability": 0.988,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 19.3,
            "electricity": 2.01,
            "site_grid": 1.99,
            "operations": 3.33,
            "total": 26.62,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 41.34,
            "electricity": 5.45,
            "site_grid": 4.25,
            "operations": 7.72,
            "total": 58.76,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 91.47,
            "electricity": 12.84,
            "site_grid": 9.41,
            "operations": 18.36,
            "total": 132.08,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 24.36,
            "electricity": 2.58,
            "site_grid": 1.77,
            "operations": 5.73,
            "total": 34.45,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 52.2,
            "electricity": 6.99,
            "site_grid": 3.8,
            "operations": 13.51,
            "total": 76.5,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 115.48,
            "electricity": 16.47,
            "site_grid": 8.41,
            "operations": 32.59,
            "total": 172.95,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.21,
          "electricity_eur_kwh": 0.174,
          "electricity_usd_kwh": 0.1995258,
          "utilization": 0.7,
          "availability": 0.988,
          "facility_capex_eur_m": 0.62,
          "connection_capex_eur_m": 0.27
        },
        "datacenter_100mw": {
          "service_units": 596.8,
          "connection_mw": 100,
          "commissioned_it_mw": 84.7,
          "pue": 1.18,
          "electricity_eur_kwh": 0.16008,
          "electricity_usd_kwh": 0.183563736,
          "utilization": 0.8,
          "availability": 0.9952,
          "facility_capex_eur_m": 741.3913280578605,
          "connection_capex_eur_m": 59.32226933853037,
          "construction_eur_m_per_it_mw": 8.748417671082754
        }
      }
    },
    {
      "code": "HU",
      "country": "Hungary",
      "group": "EU",
      "electricity_eur_kwh": 0.2132,
      "pue": 1.15,
      "landed_hardware_multiplier": 1.07,
      "hurdle_rate": 0.09,
      "facility_capex_eur_m": 0.57,
      "connection_capex_eur_m": 0.25,
      "operations_labour_multiplier": 0.68,
      "availability": 0.99,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 19.1,
            "electricity": 2.34,
            "site_grid": 1.88,
            "operations": 3.25,
            "total": 26.57,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 40.93,
            "electricity": 6.33,
            "site_grid": 4.02,
            "operations": 7.56,
            "total": 58.84,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 90.55,
            "electricity": 14.92,
            "site_grid": 8.9,
            "operations": 18.01,
            "total": 132.37,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 24.09,
            "electricity": 3.0,
            "site_grid": 1.63,
            "operations": 5.58,
            "total": 34.29,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 51.61,
            "electricity": 8.13,
            "site_grid": 3.5,
            "operations": 13.17,
            "total": 76.4,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 114.18,
            "electricity": 19.14,
            "site_grid": 7.73,
            "operations": 31.83,
            "total": 172.89,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.15,
          "electricity_eur_kwh": 0.2132,
          "electricity_usd_kwh": 0.24447644000000002,
          "utilization": 0.7,
          "availability": 0.99,
          "facility_capex_eur_m": 0.57,
          "connection_capex_eur_m": 0.25
        },
        "datacenter_100mw": {
          "service_units": 628.8,
          "connection_mw": 100,
          "commissioned_it_mw": 89.3,
          "pue": 1.1199999999999999,
          "electricity_eur_kwh": 0.196144,
          "electricity_usd_kwh": 0.2249183248,
          "utilization": 0.8,
          "availability": 0.996,
          "facility_capex_eur_m": 742.6794142049828,
          "connection_capex_eur_m": 54.92802716530589,
          "construction_eur_m_per_it_mw": 8.318009439095807
        }
      }
    },
    {
      "code": "IE",
      "country": "Ireland",
      "group": "EU",
      "electricity_eur_kwh": 0.2552,
      "pue": 1.11,
      "landed_hardware_multiplier": 1.03,
      "hurdle_rate": 0.07,
      "facility_capex_eur_m": 0.79,
      "connection_capex_eur_m": 0.6,
      "operations_labour_multiplier": 1.08,
      "availability": 0.994,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.7,
            "electricity": 2.69,
            "site_grid": 2.12,
            "operations": 3.32,
            "total": 25.84,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 37.93,
            "electricity": 7.3,
            "site_grid": 4.54,
            "operations": 7.7,
            "total": 57.47,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 83.92,
            "electricity": 17.19,
            "site_grid": 10.03,
            "operations": 18.33,
            "total": 129.48,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 22.28,
            "electricity": 3.45,
            "site_grid": 2.48,
            "operations": 6.56,
            "total": 34.77,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 47.73,
            "electricity": 9.35,
            "site_grid": 5.32,
            "operations": 15.28,
            "total": 77.68,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 105.59,
            "electricity": 22.03,
            "site_grid": 11.77,
            "operations": 36.49,
            "total": 175.88,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.11,
          "electricity_eur_kwh": 0.2552,
          "electricity_usd_kwh": 0.29263784,
          "utilization": 0.7,
          "availability": 0.994,
          "facility_capex_eur_m": 0.79,
          "connection_capex_eur_m": 0.6
        },
        "datacenter_100mw": {
          "service_units": 652.1,
          "connection_mw": 100,
          "commissioned_it_mw": 92.6,
          "pue": 1.08,
          "electricity_eur_kwh": 0.234784,
          "electricity_usd_kwh": 0.2692268128,
          "utilization": 0.8,
          "availability": 0.9976,
          "facility_capex_eur_m": 936.8002430504546,
          "connection_capex_eur_m": 131.82726519673415,
          "construction_eur_m_per_it_mw": 10.11744262494491
        }
      }
    },
    {
      "code": "IT",
      "country": "Italy",
      "group": "EU",
      "electricity_eur_kwh": 0.2203,
      "pue": 1.18,
      "landed_hardware_multiplier": 1.06,
      "hurdle_rate": 0.08,
      "facility_capex_eur_m": 0.7,
      "connection_capex_eur_m": 0.36,
      "operations_labour_multiplier": 0.88,
      "availability": 0.992,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 18.57,
            "electricity": 2.48,
            "site_grid": 2.03,
            "operations": 3.34,
            "total": 26.42,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 39.79,
            "electricity": 6.72,
            "site_grid": 4.35,
            "operations": 7.74,
            "total": 58.6,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 88.03,
            "electricity": 15.82,
            "site_grid": 9.63,
            "operations": 18.42,
            "total": 131.89,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 23.39,
            "electricity": 3.17,
            "site_grid": 2.0,
            "operations": 6.1,
            "total": 34.67,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 50.12,
            "electricity": 8.6,
            "site_grid": 4.28,
            "operations": 14.29,
            "total": 77.3,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 110.88,
            "electricity": 20.26,
            "site_grid": 9.48,
            "operations": 34.32,
            "total": 174.93,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.18,
          "electricity_eur_kwh": 0.2203,
          "electricity_usd_kwh": 0.25261801,
          "utilization": 0.7,
          "availability": 0.992,
          "facility_capex_eur_m": 0.7,
          "connection_capex_eur_m": 0.36
        },
        "datacenter_100mw": {
          "service_units": 612.4,
          "connection_mw": 100,
          "commissioned_it_mw": 87.0,
          "pue": 1.15,
          "electricity_eur_kwh": 0.202676,
          "electricity_usd_kwh": 0.2324085692,
          "utilization": 0.8,
          "availability": 0.9968,
          "facility_capex_eur_m": 818.1924715686838,
          "connection_capex_eur_m": 79.09635911804048,
          "construction_eur_m_per_it_mw": 9.409213423039864
        }
      }
    },
    {
      "code": "LV",
      "country": "Latvia",
      "group": "EU",
      "electricity_eur_kwh": 0.1361,
      "pue": 1.11,
      "landed_hardware_multiplier": 1.07,
      "hurdle_rate": 0.085,
      "facility_capex_eur_m": 0.55,
      "connection_capex_eur_m": 0.25,
      "operations_labour_multiplier": 0.68,
      "availability": 0.989,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 18.94,
            "electricity": 1.44,
            "site_grid": 1.78,
            "operations": 3.24,
            "total": 25.4,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 40.58,
            "electricity": 3.9,
            "site_grid": 3.81,
            "operations": 7.52,
            "total": 55.82,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 89.77,
            "electricity": 9.19,
            "site_grid": 8.44,
            "operations": 17.93,
            "total": 125.33,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 23.9,
            "electricity": 1.85,
            "site_grid": 1.55,
            "operations": 5.58,
            "total": 32.88,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 51.2,
            "electricity": 5.01,
            "site_grid": 3.33,
            "operations": 13.18,
            "total": 72.73,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 113.28,
            "electricity": 11.81,
            "site_grid": 7.36,
            "operations": 31.87,
            "total": 164.31,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.11,
          "electricity_eur_kwh": 0.1361,
          "electricity_usd_kwh": 0.15606587,
          "utilization": 0.7,
          "availability": 0.989,
          "facility_capex_eur_m": 0.55,
          "connection_capex_eur_m": 0.25
        },
        "datacenter_100mw": {
          "service_units": 652.1,
          "connection_mw": 100,
          "commissioned_it_mw": 92.6,
          "pue": 1.08,
          "electricity_eur_kwh": 0.12521200000000002,
          "electricity_usd_kwh": 0.14358060040000004,
          "utilization": 0.8,
          "availability": 0.9956,
          "facility_capex_eur_m": 753.8559269166522,
          "connection_capex_eur_m": 54.92802716530589,
          "construction_eur_m_per_it_mw": 8.141644010699844
        }
      }
    },
    {
      "code": "LT",
      "country": "Lithuania",
      "group": "EU",
      "electricity_eur_kwh": 0.1591,
      "pue": 1.11,
      "landed_hardware_multiplier": 1.06,
      "hurdle_rate": 0.082,
      "facility_capex_eur_m": 0.55,
      "connection_capex_eur_m": 0.26,
      "operations_labour_multiplier": 0.68,
      "availability": 0.99,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 18.65,
            "electricity": 1.68,
            "site_grid": 1.75,
            "operations": 3.21,
            "total": 25.3,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 39.97,
            "electricity": 4.56,
            "site_grid": 3.75,
            "operations": 7.47,
            "total": 55.74,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 88.42,
            "electricity": 10.74,
            "site_grid": 8.3,
            "operations": 17.81,
            "total": 125.26,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 23.52,
            "electricity": 2.16,
            "site_grid": 1.55,
            "operations": 5.54,
            "total": 32.78,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 50.4,
            "electricity": 5.86,
            "site_grid": 3.31,
            "operations": 13.1,
            "total": 72.67,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 111.5,
            "electricity": 13.79,
            "site_grid": 7.33,
            "operations": 31.68,
            "total": 164.31,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.11,
          "electricity_eur_kwh": 0.1591,
          "electricity_usd_kwh": 0.18243997,
          "utilization": 0.7,
          "availability": 0.99,
          "facility_capex_eur_m": 0.55,
          "connection_capex_eur_m": 0.26
        },
        "datacenter_100mw": {
          "service_units": 652.1,
          "connection_mw": 100,
          "commissioned_it_mw": 92.6,
          "pue": 1.08,
          "electricity_eur_kwh": 0.146372,
          "electricity_usd_kwh": 0.1678447724,
          "utilization": 0.8,
          "availability": 0.996,
          "facility_capex_eur_m": 753.8559269166522,
          "connection_capex_eur_m": 57.12514825191813,
          "construction_eur_m_per_it_mw": 8.141644010699844
        }
      }
    },
    {
      "code": "LU",
      "country": "Luxembourg",
      "group": "EU",
      "electricity_eur_kwh": 0.1717,
      "pue": 1.12,
      "landed_hardware_multiplier": 1.03,
      "hurdle_rate": 0.065,
      "facility_capex_eur_m": 0.78,
      "connection_capex_eur_m": 0.33,
      "operations_labour_multiplier": 1.12,
      "availability": 0.995,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.53,
            "electricity": 1.83,
            "site_grid": 1.94,
            "operations": 3.35,
            "total": 24.65,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 37.57,
            "electricity": 4.96,
            "site_grid": 4.15,
            "operations": 7.75,
            "total": 54.43,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 83.12,
            "electricity": 11.67,
            "site_grid": 9.18,
            "operations": 18.44,
            "total": 122.41,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 22.05,
            "electricity": 2.34,
            "site_grid": 1.93,
            "operations": 6.67,
            "total": 32.99,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 47.24,
            "electricity": 6.34,
            "site_grid": 4.13,
            "operations": 15.51,
            "total": 73.23,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 104.52,
            "electricity": 14.94,
            "site_grid": 9.14,
            "operations": 36.99,
            "total": 165.6,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.12,
          "electricity_eur_kwh": 0.1717,
          "electricity_usd_kwh": 0.19688839,
          "utilization": 0.7,
          "availability": 0.995,
          "facility_capex_eur_m": 0.78,
          "connection_capex_eur_m": 0.33
        },
        "datacenter_100mw": {
          "service_units": 646.1,
          "connection_mw": 100,
          "commissioned_it_mw": 91.7,
          "pue": 1.09,
          "electricity_eur_kwh": 0.157964,
          "electricity_usd_kwh": 0.1811373188,
          "utilization": 0.8,
          "availability": 0.998,
          "facility_capex_eur_m": 921.1381280338024,
          "connection_capex_eur_m": 72.50499585820378,
          "construction_eur_m_per_it_mw": 10.040405595568448
        }
      }
    },
    {
      "code": "MT",
      "country": "Malta",
      "group": "EU",
      "electricity_eur_kwh": 0.1352,
      "pue": 1.24,
      "landed_hardware_multiplier": 1.12,
      "hurdle_rate": 0.085,
      "facility_capex_eur_m": 0.72,
      "connection_capex_eur_m": 0.36,
      "operations_labour_multiplier": 0.82,
      "availability": 0.987,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 19.84,
            "electricity": 1.6,
            "site_grid": 2.14,
            "operations": 3.5,
            "total": 27.08,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 42.51,
            "electricity": 4.35,
            "site_grid": 4.59,
            "operations": 8.07,
            "total": 59.51,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 94.04,
            "electricity": 10.23,
            "site_grid": 10.15,
            "operations": 19.15,
            "total": 133.58,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 25.07,
            "electricity": 2.06,
            "site_grid": 2.1,
            "operations": 6.15,
            "total": 35.37,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 53.7,
            "electricity": 5.58,
            "site_grid": 4.5,
            "operations": 14.4,
            "total": 78.18,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 118.81,
            "electricity": 13.13,
            "site_grid": 9.96,
            "operations": 34.57,
            "total": 176.47,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.24,
          "electricity_eur_kwh": 0.1352,
          "electricity_usd_kwh": 0.15503383999999998,
          "utilization": 0.7,
          "availability": 0.987,
          "facility_capex_eur_m": 0.72,
          "connection_capex_eur_m": 0.36
        },
        "datacenter_100mw": {
          "service_units": 582.0,
          "connection_mw": 100,
          "commissioned_it_mw": 82.6,
          "pue": 1.21,
          "electricity_eur_kwh": 0.124384,
          "electricity_usd_kwh": 0.1426311328,
          "utilization": 0.8,
          "availability": 0.9948,
          "facility_capex_eur_m": 790.8764122832489,
          "connection_capex_eur_m": 79.09635911804048,
          "construction_eur_m_per_it_mw": 9.56960458862731
        }
      }
    },
    {
      "code": "NL",
      "country": "Netherlands",
      "group": "EU",
      "electricity_eur_kwh": 0.1991,
      "pue": 1.11,
      "landed_hardware_multiplier": 1.02,
      "hurdle_rate": 0.067,
      "facility_capex_eur_m": 0.78,
      "connection_capex_eur_m": 0.54,
      "operations_labour_multiplier": 1.06,
      "availability": 0.995,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.43,
            "electricity": 2.1,
            "site_grid": 2.04,
            "operations": 3.29,
            "total": 24.86,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 37.34,
            "electricity": 5.69,
            "site_grid": 4.37,
            "operations": 7.63,
            "total": 55.03,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 82.61,
            "electricity": 13.41,
            "site_grid": 9.66,
            "operations": 18.16,
            "total": 123.85,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 21.92,
            "electricity": 2.69,
            "site_grid": 2.32,
            "operations": 6.47,
            "total": 33.39,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 46.96,
            "electricity": 7.29,
            "site_grid": 4.97,
            "operations": 15.08,
            "total": 74.29,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 103.89,
            "electricity": 17.17,
            "site_grid": 10.99,
            "operations": 36.04,
            "total": 168.09,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.11,
          "electricity_eur_kwh": 0.1991,
          "electricity_usd_kwh": 0.22830797,
          "utilization": 0.7,
          "availability": 0.995,
          "facility_capex_eur_m": 0.78,
          "connection_capex_eur_m": 0.54
        },
        "datacenter_100mw": {
          "service_units": 652.1,
          "connection_mw": 100,
          "commissioned_it_mw": 92.6,
          "pue": 1.08,
          "electricity_eur_kwh": 0.183172,
          "electricity_usd_kwh": 0.2100433324,
          "utilization": 0.8,
          "availability": 0.998,
          "facility_capex_eur_m": 929.6671847748562,
          "connection_capex_eur_m": 118.64453867706074,
          "construction_eur_m_per_it_mw": 10.040405595568448
        }
      }
    },
    {
      "code": "PL",
      "country": "Poland",
      "group": "EU",
      "electricity_eur_kwh": 0.1915,
      "pue": 1.13,
      "landed_hardware_multiplier": 1.06,
      "hurdle_rate": 0.085,
      "facility_capex_eur_m": 0.6,
      "connection_capex_eur_m": 0.31,
      "operations_labour_multiplier": 0.7,
      "availability": 0.992,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 18.74,
            "electricity": 2.06,
            "site_grid": 1.9,
            "operations": 3.23,
            "total": 25.92,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 40.15,
            "electricity": 5.58,
            "site_grid": 4.06,
            "operations": 7.5,
            "total": 57.3,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 88.83,
            "electricity": 13.15,
            "site_grid": 8.99,
            "operations": 17.88,
            "total": 128.85,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 23.6,
            "electricity": 2.64,
            "site_grid": 1.76,
            "operations": 5.59,
            "total": 33.6,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 50.57,
            "electricity": 7.16,
            "site_grid": 3.77,
            "operations": 13.2,
            "total": 74.7,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 111.88,
            "electricity": 16.86,
            "site_grid": 8.35,
            "operations": 31.89,
            "total": 168.98,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.13,
          "electricity_eur_kwh": 0.1915,
          "electricity_usd_kwh": 0.21959305,
          "utilization": 0.7,
          "availability": 0.992,
          "facility_capex_eur_m": 0.6,
          "connection_capex_eur_m": 0.31
        },
        "datacenter_100mw": {
          "service_units": 640.2,
          "connection_mw": 100,
          "commissioned_it_mw": 90.9,
          "pue": 1.0999999999999999,
          "electricity_eur_kwh": 0.17618,
          "electricity_usd_kwh": 0.20202560600000002,
          "utilization": 0.8,
          "availability": 0.9968,
          "facility_capex_eur_m": 779.8167521300101,
          "connection_capex_eur_m": 68.1107536849793,
          "construction_eur_m_per_it_mw": 8.57798427343011
        }
      }
    },
    {
      "code": "PT",
      "country": "Portugal",
      "group": "EU",
      "electricity_eur_kwh": 0.1329,
      "pue": 1.18,
      "landed_hardware_multiplier": 1.06,
      "hurdle_rate": 0.078,
      "facility_capex_eur_m": 0.62,
      "connection_capex_eur_m": 0.28,
      "operations_labour_multiplier": 0.76,
      "availability": 0.991,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 18.51,
            "electricity": 1.5,
            "site_grid": 1.84,
            "operations": 3.28,
            "total": 25.13,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 39.66,
            "electricity": 4.05,
            "site_grid": 3.95,
            "operations": 7.62,
            "total": 55.27,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 87.74,
            "electricity": 9.55,
            "site_grid": 8.73,
            "operations": 18.14,
            "total": 124.16,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 23.33,
            "electricity": 1.92,
            "site_grid": 1.68,
            "operations": 5.77,
            "total": 32.7,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 49.99,
            "electricity": 5.19,
            "site_grid": 3.6,
            "operations": 13.58,
            "total": 72.36,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 110.59,
            "electricity": 12.23,
            "site_grid": 7.97,
            "operations": 32.73,
            "total": 163.53,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.18,
          "electricity_eur_kwh": 0.1329,
          "electricity_usd_kwh": 0.15239643,
          "utilization": 0.7,
          "availability": 0.991,
          "facility_capex_eur_m": 0.62,
          "connection_capex_eur_m": 0.28
        },
        "datacenter_100mw": {
          "service_units": 612.4,
          "connection_mw": 100,
          "commissioned_it_mw": 87.0,
          "pue": 1.15,
          "electricity_eur_kwh": 0.122268,
          "electricity_usd_kwh": 0.1402047156,
          "utilization": 0.8,
          "availability": 0.9964,
          "facility_capex_eur_m": 760.7319713985004,
          "connection_capex_eur_m": 61.5193904251426,
          "construction_eur_m_per_it_mw": 8.748417671082754
        }
      }
    },
    {
      "code": "RO",
      "country": "Romania",
      "group": "EU",
      "electricity_eur_kwh": 0.1887,
      "pue": 1.16,
      "landed_hardware_multiplier": 1.08,
      "hurdle_rate": 0.098,
      "facility_capex_eur_m": 0.56,
      "connection_capex_eur_m": 0.26,
      "operations_labour_multiplier": 0.62,
      "availability": 0.988,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 19.57,
            "electricity": 2.09,
            "site_grid": 1.96,
            "operations": 3.26,
            "total": 26.88,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 41.94,
            "electricity": 5.66,
            "site_grid": 4.19,
            "operations": 7.56,
            "total": 59.35,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 92.78,
            "electricity": 13.33,
            "site_grid": 9.28,
            "operations": 18.02,
            "total": 133.41,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 24.71,
            "electricity": 2.68,
            "site_grid": 1.7,
            "operations": 5.45,
            "total": 34.54,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 52.94,
            "electricity": 7.27,
            "site_grid": 3.64,
            "operations": 12.89,
            "total": 76.76,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 117.13,
            "electricity": 17.13,
            "site_grid": 8.06,
            "operations": 31.23,
            "total": 173.56,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.16,
          "electricity_eur_kwh": 0.1887,
          "electricity_usd_kwh": 0.21638229,
          "utilization": 0.7,
          "availability": 0.988,
          "facility_capex_eur_m": 0.56,
          "connection_capex_eur_m": 0.26
        },
        "datacenter_100mw": {
          "service_units": 623.2,
          "connection_mw": 100,
          "commissioned_it_mw": 88.5,
          "pue": 1.13,
          "electricity_eur_kwh": 0.173604,
          "electricity_usd_kwh": 0.19907170680000003,
          "utilization": 0.8,
          "availability": 0.9952,
          "facility_capex_eur_m": 728.3311222930831,
          "connection_capex_eur_m": 57.12514825191813,
          "construction_eur_m_per_it_mw": 8.230141681911839
        }
      }
    },
    {
      "code": "SK",
      "country": "Slovakia",
      "group": "EU",
      "electricity_eur_kwh": 0.209,
      "pue": 1.14,
      "landed_hardware_multiplier": 1.06,
      "hurdle_rate": 0.085,
      "facility_capex_eur_m": 0.58,
      "connection_capex_eur_m": 0.27,
      "operations_labour_multiplier": 0.72,
      "availability": 0.991,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 18.75,
            "electricity": 2.27,
            "site_grid": 1.85,
            "operations": 3.24,
            "total": 26.11,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 40.17,
            "electricity": 6.15,
            "site_grid": 3.95,
            "operations": 7.53,
            "total": 57.8,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 88.86,
            "electricity": 14.49,
            "site_grid": 8.75,
            "operations": 17.96,
            "total": 130.05,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 23.63,
            "electricity": 2.91,
            "site_grid": 1.65,
            "operations": 5.65,
            "total": 33.84,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 50.62,
            "electricity": 7.89,
            "site_grid": 3.53,
            "operations": 13.33,
            "total": 75.37,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 111.99,
            "electricity": 18.59,
            "site_grid": 7.81,
            "operations": 32.19,
            "total": 170.58,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.14,
          "electricity_eur_kwh": 0.209,
          "electricity_usd_kwh": 0.2396603,
          "utilization": 0.7,
          "availability": 0.991,
          "facility_capex_eur_m": 0.58,
          "connection_capex_eur_m": 0.27
        },
        "datacenter_100mw": {
          "service_units": 634.4,
          "connection_mw": 100,
          "commissioned_it_mw": 90.1,
          "pue": 1.1099999999999999,
          "electricity_eur_kwh": 0.19228,
          "electricity_usd_kwh": 0.22048747600000002,
          "utilization": 0.8,
          "availability": 0.9964,
          "facility_capex_eur_m": 757.2308739869351,
          "connection_capex_eur_m": 59.32226933853037,
          "construction_eur_m_per_it_mw": 8.405262701254978
        }
      }
    },
    {
      "code": "SI",
      "country": "Slovenia",
      "group": "EU",
      "electricity_eur_kwh": 0.1503,
      "pue": 1.14,
      "landed_hardware_multiplier": 1.05,
      "hurdle_rate": 0.078,
      "facility_capex_eur_m": 0.6,
      "connection_capex_eur_m": 0.27,
      "operations_labour_multiplier": 0.8,
      "availability": 0.992,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 18.33,
            "electricity": 1.63,
            "site_grid": 1.8,
            "operations": 3.26,
            "total": 25.02,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 39.27,
            "electricity": 4.42,
            "site_grid": 3.85,
            "operations": 7.56,
            "total": 55.11,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 86.88,
            "electricity": 10.42,
            "site_grid": 8.53,
            "operations": 18.02,
            "total": 123.84,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 23.09,
            "electricity": 2.09,
            "site_grid": 1.62,
            "operations": 5.84,
            "total": 32.65,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 49.47,
            "electricity": 5.67,
            "site_grid": 3.48,
            "operations": 13.74,
            "total": 72.35,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 109.44,
            "electricity": 13.35,
            "site_grid": 7.7,
            "operations": 33.09,
            "total": 163.58,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.14,
          "electricity_eur_kwh": 0.1503,
          "electricity_usd_kwh": 0.17234901,
          "utilization": 0.7,
          "availability": 0.992,
          "facility_capex_eur_m": 0.6,
          "connection_capex_eur_m": 0.27
        },
        "datacenter_100mw": {
          "service_units": 634.4,
          "connection_mw": 100,
          "commissioned_it_mw": 90.1,
          "pue": 1.1099999999999999,
          "electricity_eur_kwh": 0.13827599999999998,
          "electricity_usd_kwh": 0.15856108919999998,
          "utilization": 0.8,
          "availability": 0.9968,
          "facility_capex_eur_m": 772.7913759846947,
          "connection_capex_eur_m": 59.32226933853037,
          "construction_eur_m_per_it_mw": 8.57798427343011
        }
      }
    },
    {
      "code": "ES",
      "country": "Spain",
      "group": "EU",
      "electricity_eur_kwh": 0.1324,
      "pue": 1.18,
      "landed_hardware_multiplier": 1.04,
      "hurdle_rate": 0.075,
      "facility_capex_eur_m": 0.66,
      "connection_capex_eur_m": 0.32,
      "operations_labour_multiplier": 0.78,
      "availability": 0.993,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 18.05,
            "electricity": 1.49,
            "site_grid": 1.89,
            "operations": 3.24,
            "total": 24.66,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 38.67,
            "electricity": 4.03,
            "site_grid": 4.04,
            "operations": 7.53,
            "total": 54.27,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 85.55,
            "electricity": 9.5,
            "site_grid": 8.94,
            "operations": 17.94,
            "total": 121.93,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 22.72,
            "electricity": 1.9,
            "site_grid": 1.8,
            "operations": 5.75,
            "total": 32.17,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 48.68,
            "electricity": 5.16,
            "site_grid": 3.86,
            "operations": 13.54,
            "total": 71.24,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 107.7,
            "electricity": 12.16,
            "site_grid": 8.53,
            "operations": 32.64,
            "total": 161.03,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.18,
          "electricity_eur_kwh": 0.1324,
          "electricity_usd_kwh": 0.15182308,
          "utilization": 0.7,
          "availability": 0.993,
          "facility_capex_eur_m": 0.66,
          "connection_capex_eur_m": 0.32
        },
        "datacenter_100mw": {
          "service_units": 612.4,
          "connection_mw": 100,
          "commissioned_it_mw": 87.0,
          "pue": 1.15,
          "electricity_eur_kwh": 0.121808,
          "electricity_usd_kwh": 0.1396772336,
          "utilization": 0.8,
          "availability": 0.9972,
          "facility_capex_eur_m": 789.8107061077976,
          "connection_capex_eur_m": 70.30787477159154,
          "construction_eur_m_per_it_mw": 9.082823120239672
        }
      }
    },
    {
      "code": "SE",
      "country": "Sweden",
      "group": "EU",
      "electricity_eur_kwh": 0.097,
      "pue": 1.09,
      "landed_hardware_multiplier": 1.01,
      "hurdle_rate": 0.062,
      "facility_capex_eur_m": 0.63,
      "connection_capex_eur_m": 0.29,
      "operations_labour_multiplier": 1.02,
      "availability": 0.996,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.09,
            "electricity": 1.01,
            "site_grid": 1.67,
            "operations": 3.24,
            "total": 23.01,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 36.62,
            "electricity": 2.75,
            "site_grid": 3.57,
            "operations": 7.52,
            "total": 50.46,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 81.02,
            "electricity": 6.47,
            "site_grid": 7.9,
            "operations": 17.92,
            "total": 113.31,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 21.48,
            "electricity": 1.29,
            "site_grid": 1.57,
            "operations": 6.32,
            "total": 30.66,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 46.03,
            "electricity": 3.48,
            "site_grid": 3.37,
            "operations": 14.75,
            "total": 67.63,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 101.82,
            "electricity": 8.21,
            "site_grid": 7.45,
            "operations": 35.32,
            "total": 152.8,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.09,
          "electricity_eur_kwh": 0.097,
          "electricity_usd_kwh": 0.1112299,
          "utilization": 0.7,
          "availability": 0.996,
          "facility_capex_eur_m": 0.63,
          "connection_capex_eur_m": 0.29
        },
        "datacenter_100mw": {
          "service_units": 658.2,
          "connection_mw": 100,
          "commissioned_it_mw": 93.5,
          "pue": 1.07,
          "electricity_eur_kwh": 0.08924,
          "electricity_usd_kwh": 0.102331508,
          "utilization": 0.8,
          "availability": 0.9984,
          "facility_capex_eur_m": 825.49614111669,
          "connection_capex_eur_m": 63.71651151175483,
          "construction_eur_m_per_it_mw": 8.832808709948583
        }
      }
    },
    {
      "code": "IS",
      "country": "Iceland",
      "group": "Europe",
      "electricity_eur_kwh": 0.075,
      "pue": 1.08,
      "landed_hardware_multiplier": 1.09,
      "hurdle_rate": 0.075,
      "facility_capex_eur_m": 0.67,
      "connection_capex_eur_m": 0.3,
      "operations_labour_multiplier": 1.0,
      "availability": 0.992,
      "evidence_grade": "C",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 18.92,
            "electricity": 0.78,
            "site_grid": 1.89,
            "operations": 3.43,
            "total": 25.02,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 40.54,
            "electricity": 2.13,
            "site_grid": 4.04,
            "operations": 7.93,
            "total": 54.64,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 89.7,
            "electricity": 5.01,
            "site_grid": 8.94,
            "operations": 18.84,
            "total": 122.48,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 23.84,
            "electricity": 0.99,
            "site_grid": 1.78,
            "operations": 6.54,
            "total": 33.15,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 51.07,
            "electricity": 2.68,
            "site_grid": 3.82,
            "operations": 15.22,
            "total": 72.8,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 112.99,
            "electricity": 6.31,
            "site_grid": 8.45,
            "operations": 36.38,
            "total": 164.13,
            "local_uncertainty_pct": 18
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.08,
          "electricity_eur_kwh": 0.075,
          "electricity_usd_kwh": 0.0860025,
          "utilization": 0.7,
          "availability": 0.992,
          "facility_capex_eur_m": 0.67,
          "connection_capex_eur_m": 0.3
        },
        "datacenter_100mw": {
          "service_units": 658.2,
          "connection_mw": 100,
          "commissioned_it_mw": 93.5,
          "pue": 1.07,
          "electricity_eur_kwh": 0.069,
          "electricity_usd_kwh": 0.0791223,
          "utilization": 0.8,
          "availability": 0.9968,
          "facility_capex_eur_m": 856.5556801198568,
          "connection_capex_eur_m": 65.91363259836707,
          "construction_eur_m_per_it_mw": 9.165145777282468
        }
      }
    },
    {
      "code": "NO",
      "country": "Norway",
      "group": "Europe",
      "electricity_eur_kwh": 0.0827,
      "pue": 1.09,
      "landed_hardware_multiplier": 1.02,
      "hurdle_rate": 0.063,
      "facility_capex_eur_m": 0.66,
      "connection_capex_eur_m": 0.3,
      "operations_labour_multiplier": 1.1,
      "availability": 0.996,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.29,
            "electricity": 0.86,
            "site_grid": 1.73,
            "operations": 3.3,
            "total": 23.18,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 37.05,
            "electricity": 2.34,
            "site_grid": 3.7,
            "operations": 7.65,
            "total": 50.74,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 81.97,
            "electricity": 5.52,
            "site_grid": 8.18,
            "operations": 18.22,
            "total": 113.89,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 21.73,
            "electricity": 1.1,
            "site_grid": 1.65,
            "operations": 6.58,
            "total": 31.05,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 46.57,
            "electricity": 2.97,
            "site_grid": 3.53,
            "operations": 15.3,
            "total": 68.37,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 103.02,
            "electricity": 7.0,
            "site_grid": 7.81,
            "operations": 36.54,
            "total": 154.37,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.09,
          "electricity_eur_kwh": 0.0827,
          "electricity_usd_kwh": 0.09483209,
          "utilization": 0.7,
          "availability": 0.996,
          "facility_capex_eur_m": 0.66,
          "connection_capex_eur_m": 0.3
        },
        "datacenter_100mw": {
          "service_units": 658.2,
          "connection_mw": 100,
          "commissioned_it_mw": 93.5,
          "pue": 1.07,
          "electricity_eur_kwh": 0.076084,
          "electricity_usd_kwh": 0.0872455228,
          "utilization": 0.8,
          "availability": 0.9984,
          "facility_capex_eur_m": 848.8619738541748,
          "connection_capex_eur_m": 65.91363259836707,
          "construction_eur_m_per_it_mw": 9.082823120239672
        }
      }
    },
    {
      "code": "CH",
      "country": "Switzerland",
      "group": "Europe",
      "electricity_eur_kwh": 0.228,
      "pue": 1.12,
      "landed_hardware_multiplier": 1.04,
      "hurdle_rate": 0.058,
      "facility_capex_eur_m": 0.82,
      "connection_capex_eur_m": 0.38,
      "operations_labour_multiplier": 1.22,
      "availability": 0.996,
      "evidence_grade": "C",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.47,
            "electricity": 2.43,
            "site_grid": 1.92,
            "operations": 3.42,
            "total": 25.23,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 37.43,
            "electricity": 6.58,
            "site_grid": 4.11,
            "operations": 7.91,
            "total": 56.02,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 82.81,
            "electricity": 15.49,
            "site_grid": 9.08,
            "operations": 18.78,
            "total": 126.16,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 21.96,
            "electricity": 3.1,
            "site_grid": 2.0,
            "operations": 6.98,
            "total": 34.04,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 47.04,
            "electricity": 8.42,
            "site_grid": 4.3,
            "operations": 16.16,
            "total": 75.92,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 104.08,
            "electricity": 19.82,
            "site_grid": 9.5,
            "operations": 38.45,
            "total": 171.84,
            "local_uncertainty_pct": 18
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.12,
          "electricity_eur_kwh": 0.228,
          "electricity_usd_kwh": 0.2614476,
          "utilization": 0.7,
          "availability": 0.996,
          "facility_capex_eur_m": 0.82,
          "connection_capex_eur_m": 0.38
        },
        "datacenter_100mw": {
          "service_units": 646.1,
          "connection_mw": 100,
          "commissioned_it_mw": 91.7,
          "pue": 1.09,
          "electricity_eur_kwh": 0.20976000000000003,
          "electricity_usd_kwh": 0.24053179200000005,
          "utilization": 0.8,
          "availability": 0.9984,
          "facility_capex_eur_m": 949.1968951176023,
          "connection_capex_eur_m": 83.49060129126495,
          "construction_eur_m_per_it_mw": 10.346246156781866
        }
      }
    },
    {
      "code": "GB",
      "country": "United Kingdom",
      "group": "Europe",
      "electricity_eur_kwh": 0.3052,
      "pue": 1.12,
      "landed_hardware_multiplier": 1.03,
      "hurdle_rate": 0.073,
      "facility_capex_eur_m": 0.78,
      "connection_capex_eur_m": 0.49,
      "operations_labour_multiplier": 1.08,
      "availability": 0.994,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.8,
            "electricity": 3.25,
            "site_grid": 2.1,
            "operations": 3.33,
            "total": 26.49,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 38.14,
            "electricity": 8.81,
            "site_grid": 4.51,
            "operations": 7.72,
            "total": 59.18,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 84.38,
            "electricity": 20.75,
            "site_grid": 9.97,
            "operations": 18.36,
            "total": 133.47,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 22.4,
            "electricity": 4.16,
            "site_grid": 2.31,
            "operations": 6.56,
            "total": 35.43,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 47.99,
            "electricity": 11.29,
            "site_grid": 4.94,
            "operations": 15.28,
            "total": 79.49,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 106.17,
            "electricity": 26.58,
            "site_grid": 10.93,
            "operations": 36.49,
            "total": 180.17,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.12,
          "electricity_eur_kwh": 0.3052,
          "electricity_usd_kwh": 0.34997284000000006,
          "utilization": 0.7,
          "availability": 0.994,
          "facility_capex_eur_m": 0.78,
          "connection_capex_eur_m": 0.49
        },
        "datacenter_100mw": {
          "service_units": 646.1,
          "connection_mw": 100,
          "commissioned_it_mw": 91.7,
          "pue": 1.09,
          "electricity_eur_kwh": 0.28078400000000003,
          "electricity_usd_kwh": 0.32197501280000007,
          "utilization": 0.8,
          "availability": 0.9976,
          "facility_capex_eur_m": 921.1381280338024,
          "connection_capex_eur_m": 107.65893324399954,
          "construction_eur_m_per_it_mw": 10.040405595568448
        }
      }
    },
    {
      "code": "US",
      "country": "United States",
      "group": "North America",
      "electricity_eur_kwh": 0.0752,
      "pue": 1.15,
      "landed_hardware_multiplier": 1.0,
      "hurdle_rate": 0.08,
      "facility_capex_eur_m": 0.7,
      "connection_capex_eur_m": 0.36,
      "operations_labour_multiplier": 1.12,
      "availability": 0.994,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.51,
            "electricity": 0.82,
            "site_grid": 2.03,
            "operations": 3.29,
            "total": 23.65,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 37.51,
            "electricity": 2.23,
            "site_grid": 4.34,
            "operations": 7.64,
            "total": 51.72,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 82.98,
            "electricity": 5.25,
            "site_grid": 9.6,
            "operations": 18.19,
            "total": 116.02,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 22.02,
            "electricity": 1.05,
            "site_grid": 2.0,
            "operations": 6.58,
            "total": 31.66,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 47.19,
            "electricity": 2.86,
            "site_grid": 4.28,
            "operations": 15.32,
            "total": 69.64,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 104.39,
            "electricity": 6.73,
            "site_grid": 9.46,
            "operations": 36.59,
            "total": 157.17,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.15,
          "electricity_eur_kwh": 0.0752,
          "electricity_usd_kwh": 0.08623184,
          "utilization": 0.7,
          "availability": 0.994,
          "facility_capex_eur_m": 0.7,
          "connection_capex_eur_m": 0.36
        },
        "datacenter_100mw": {
          "service_units": 628.8,
          "connection_mw": 100,
          "commissioned_it_mw": 89.3,
          "pue": 1.1199999999999999,
          "electricity_eur_kwh": 0.06918400000000001,
          "electricity_usd_kwh": 0.07933329280000001,
          "utilization": 0.8,
          "availability": 0.9976,
          "facility_capex_eur_m": 840.108341342845,
          "connection_capex_eur_m": 79.09635911804048,
          "construction_eur_m_per_it_mw": 9.409213423039864
        }
      }
    },
    {
      "code": "CA",
      "country": "Canada",
      "group": "North America",
      "electricity_eur_kwh": 0.074,
      "pue": 1.1,
      "landed_hardware_multiplier": 1.03,
      "hurdle_rate": 0.075,
      "facility_capex_eur_m": 0.68,
      "connection_capex_eur_m": 0.32,
      "operations_labour_multiplier": 1.02,
      "availability": 0.995,
      "evidence_grade": "C",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.86,
            "electricity": 0.77,
            "site_grid": 1.91,
            "operations": 3.29,
            "total": 23.83,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 38.27,
            "electricity": 2.1,
            "site_grid": 4.09,
            "operations": 7.63,
            "total": 52.08,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 84.66,
            "electricity": 4.94,
            "site_grid": 9.04,
            "operations": 18.16,
            "total": 116.8,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 22.46,
            "electricity": 0.99,
            "site_grid": 1.83,
            "operations": 6.39,
            "total": 31.67,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 48.12,
            "electricity": 2.69,
            "site_grid": 3.93,
            "operations": 14.9,
            "total": 69.63,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 106.45,
            "electricity": 6.32,
            "site_grid": 8.69,
            "operations": 35.65,
            "total": 157.11,
            "local_uncertainty_pct": 18
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.1,
          "electricity_eur_kwh": 0.074,
          "electricity_usd_kwh": 0.0848558,
          "utilization": 0.7,
          "availability": 0.995,
          "facility_capex_eur_m": 0.68,
          "connection_capex_eur_m": 0.32
        },
        "datacenter_100mw": {
          "service_units": 658.2,
          "connection_mw": 100,
          "commissioned_it_mw": 93.5,
          "pue": 1.07,
          "electricity_eur_kwh": 0.06808,
          "electricity_usd_kwh": 0.078067336,
          "utilization": 0.8,
          "availability": 0.998,
          "facility_capex_eur_m": 864.2035886160515,
          "connection_capex_eur_m": 70.30787477159154,
          "construction_eur_m_per_it_mw": 9.246978398191752
        }
      }
    },
    {
      "code": "MX",
      "country": "Mexico",
      "group": "North America",
      "electricity_eur_kwh": 0.113,
      "pue": 1.2,
      "landed_hardware_multiplier": 1.1,
      "hurdle_rate": 0.12,
      "facility_capex_eur_m": 0.56,
      "connection_capex_eur_m": 0.29,
      "operations_labour_multiplier": 0.62,
      "availability": 0.985,
      "evidence_grade": "C",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 20.75,
            "electricity": 1.3,
            "site_grid": 2.24,
            "operations": 3.33,
            "total": 27.61,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 44.45,
            "electricity": 3.51,
            "site_grid": 4.81,
            "operations": 7.71,
            "total": 60.48,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 98.33,
            "electricity": 8.28,
            "site_grid": 10.64,
            "operations": 18.35,
            "total": 135.6,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 26.23,
            "electricity": 1.67,
            "site_grid": 1.96,
            "operations": 5.53,
            "total": 35.39,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 56.2,
            "electricity": 4.52,
            "site_grid": 4.21,
            "operations": 13.07,
            "total": 78.0,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 124.34,
            "electricity": 10.64,
            "site_grid": 9.31,
            "operations": 31.63,
            "total": 175.92,
            "local_uncertainty_pct": 18
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.2,
          "electricity_eur_kwh": 0.113,
          "electricity_usd_kwh": 0.1295771,
          "utilization": 0.7,
          "availability": 0.985,
          "facility_capex_eur_m": 0.56,
          "connection_capex_eur_m": 0.29
        },
        "datacenter_100mw": {
          "service_units": 601.9,
          "connection_mw": 100,
          "commissioned_it_mw": 85.5,
          "pue": 1.17,
          "electricity_eur_kwh": 0.10396000000000001,
          "electricity_usd_kwh": 0.11921093200000002,
          "utilization": 0.8,
          "availability": 0.994,
          "facility_capex_eur_m": 703.4309129839179,
          "connection_capex_eur_m": 63.71651151175483,
          "construction_eur_m_per_it_mw": 8.230141681911839
        }
      }
    },
    {
      "code": "CN",
      "country": "China",
      "group": "Asia",
      "electricity_eur_kwh": 0.08,
      "pue": 1.16,
      "landed_hardware_multiplier": 1.0,
      "hurdle_rate": 0.075,
      "facility_capex_eur_m": 0.58,
      "connection_capex_eur_m": 0.28,
      "operations_labour_multiplier": 0.68,
      "availability": 0.995,
      "evidence_grade": "D",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.34,
            "electricity": 0.88,
            "site_grid": 1.74,
            "operations": 3.08,
            "total": 23.04,
            "local_uncertainty_pct": 25
          },
          "long_context": {
            "hardware": 37.15,
            "electricity": 2.39,
            "site_grid": 3.72,
            "operations": 7.18,
            "total": 50.45,
            "local_uncertainty_pct": 25
          },
          "agentic": {
            "hardware": 82.19,
            "electricity": 5.64,
            "site_grid": 8.23,
            "operations": 17.18,
            "total": 113.24,
            "local_uncertainty_pct": 25
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 21.8,
            "electricity": 1.13,
            "site_grid": 1.58,
            "operations": 5.33,
            "total": 29.84,
            "local_uncertainty_pct": 25
          },
          "long_context": {
            "hardware": 46.71,
            "electricity": 3.06,
            "site_grid": 3.38,
            "operations": 12.63,
            "total": 65.79,
            "local_uncertainty_pct": 25
          },
          "agentic": {
            "hardware": 103.35,
            "electricity": 7.21,
            "site_grid": 7.47,
            "operations": 30.64,
            "total": 148.67,
            "local_uncertainty_pct": 25
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.16,
          "electricity_eur_kwh": 0.08,
          "electricity_usd_kwh": 0.09173600000000001,
          "utilization": 0.7,
          "availability": 0.995,
          "facility_capex_eur_m": 0.58,
          "connection_capex_eur_m": 0.28
        },
        "datacenter_100mw": {
          "service_units": 623.2,
          "connection_mw": 100,
          "commissioned_it_mw": 88.5,
          "pue": 1.13,
          "electricity_eur_kwh": 0.0736,
          "electricity_usd_kwh": 0.08439712,
          "utilization": 0.8,
          "availability": 0.998,
          "facility_capex_eur_m": 743.828557633184,
          "connection_capex_eur_m": 61.5193904251426,
          "construction_eur_m_per_it_mw": 8.405262701254978
        }
      }
    },
    {
      "code": "IN",
      "country": "India",
      "group": "Asia",
      "electricity_eur_kwh": 0.088,
      "pue": 1.24,
      "landed_hardware_multiplier": 1.17,
      "hurdle_rate": 0.115,
      "facility_capex_eur_m": 0.52,
      "connection_capex_eur_m": 0.25,
      "operations_labour_multiplier": 0.48,
      "availability": 0.982,
      "evidence_grade": "C",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 21.9,
            "electricity": 1.05,
            "site_grid": 2.08,
            "operations": 3.44,
            "total": 28.47,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 46.92,
            "electricity": 2.83,
            "site_grid": 4.46,
            "operations": 7.96,
            "total": 62.18,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 103.81,
            "electricity": 6.67,
            "site_grid": 9.86,
            "operations": 18.92,
            "total": 139.26,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 27.75,
            "electricity": 1.35,
            "site_grid": 1.74,
            "operations": 5.36,
            "total": 36.2,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 59.45,
            "electricity": 3.65,
            "site_grid": 3.74,
            "operations": 12.72,
            "total": 79.55,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 131.51,
            "electricity": 8.59,
            "site_grid": 8.27,
            "operations": 30.87,
            "total": 179.24,
            "local_uncertainty_pct": 18
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.24,
          "electricity_eur_kwh": 0.088,
          "electricity_usd_kwh": 0.1009096,
          "utilization": 0.7,
          "availability": 0.982,
          "facility_capex_eur_m": 0.52,
          "connection_capex_eur_m": 0.25
        },
        "datacenter_100mw": {
          "service_units": 582.0,
          "connection_mw": 100,
          "commissioned_it_mw": 82.6,
          "pue": 1.21,
          "electricity_eur_kwh": 0.08096,
          "electricity_usd_kwh": 0.09283683200000001,
          "utilization": 0.8,
          "availability": 0.9928,
          "facility_capex_eur_m": 650.59561424724,
          "connection_capex_eur_m": 54.92802716530589,
          "construction_eur_m_per_it_mw": 7.872206932391602
        }
      }
    },
    {
      "code": "JP",
      "country": "Japan",
      "group": "Asia",
      "electricity_eur_kwh": 0.139,
      "pue": 1.17,
      "landed_hardware_multiplier": 1.06,
      "hurdle_rate": 0.052,
      "facility_capex_eur_m": 0.78,
      "connection_capex_eur_m": 0.42,
      "operations_labour_multiplier": 0.95,
      "availability": 0.997,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.7,
            "electricity": 1.55,
            "site_grid": 1.85,
            "operations": 3.36,
            "total": 24.45,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 37.92,
            "electricity": 4.19,
            "site_grid": 3.95,
            "operations": 7.79,
            "total": 53.86,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 83.89,
            "electricity": 9.87,
            "site_grid": 8.75,
            "operations": 18.52,
            "total": 121.04,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 22.11,
            "electricity": 1.98,
            "site_grid": 1.94,
            "operations": 6.27,
            "total": 32.29,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 47.37,
            "electricity": 5.35,
            "site_grid": 4.15,
            "operations": 14.65,
            "total": 71.52,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 104.79,
            "electricity": 12.61,
            "site_grid": 9.18,
            "operations": 35.08,
            "total": 161.67,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.17,
          "electricity_eur_kwh": 0.139,
          "electricity_usd_kwh": 0.1593913,
          "utilization": 0.7,
          "availability": 0.997,
          "facility_capex_eur_m": 0.78,
          "connection_capex_eur_m": 0.42
        },
        "datacenter_100mw": {
          "service_units": 617.7,
          "connection_mw": 100,
          "commissioned_it_mw": 87.7,
          "pue": 1.14,
          "electricity_eur_kwh": 0.12788000000000002,
          "electricity_usd_kwh": 0.14663999600000002,
          "utilization": 0.8,
          "availability": 0.9988,
          "facility_capex_eur_m": 880.7373329446008,
          "connection_capex_eur_m": 92.27908563771389,
          "construction_eur_m_per_it_mw": 10.040405595568448
        }
      }
    },
    {
      "code": "KR",
      "country": "South Korea",
      "group": "Asia",
      "electricity_eur_kwh": 0.096,
      "pue": 1.17,
      "landed_hardware_multiplier": 1.06,
      "hurdle_rate": 0.07,
      "facility_capex_eur_m": 0.69,
      "connection_capex_eur_m": 0.36,
      "operations_labour_multiplier": 0.86,
      "availability": 0.995,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 18.21,
            "electricity": 1.07,
            "site_grid": 1.89,
            "operations": 3.32,
            "total": 24.49,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 39.02,
            "electricity": 2.9,
            "site_grid": 4.04,
            "operations": 7.7,
            "total": 53.66,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 86.33,
            "electricity": 6.82,
            "site_grid": 8.94,
            "operations": 18.32,
            "total": 120.42,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 22.9,
            "electricity": 1.37,
            "site_grid": 1.87,
            "operations": 6.03,
            "total": 32.17,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 49.07,
            "electricity": 3.71,
            "site_grid": 4.01,
            "operations": 14.13,
            "total": 70.92,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 108.56,
            "electricity": 8.73,
            "site_grid": 8.88,
            "operations": 33.94,
            "total": 160.11,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.17,
          "electricity_eur_kwh": 0.096,
          "electricity_usd_kwh": 0.1100832,
          "utilization": 0.7,
          "availability": 0.995,
          "facility_capex_eur_m": 0.69,
          "connection_capex_eur_m": 0.36
        },
        "datacenter_100mw": {
          "service_units": 617.7,
          "connection_mw": 100,
          "commissioned_it_mw": 87.7,
          "pue": 1.14,
          "electricity_eur_kwh": 0.08832000000000001,
          "electricity_usd_kwh": 0.10127654400000001,
          "utilization": 0.8,
          "availability": 0.998,
          "facility_capex_eur_m": 818.2746528999719,
          "connection_capex_eur_m": 79.09635911804048,
          "construction_eur_m_per_it_mw": 9.328331043059679
        }
      }
    },
    {
      "code": "TW",
      "country": "Taiwan",
      "group": "Asia",
      "electricity_eur_kwh": 0.117,
      "pue": 1.18,
      "landed_hardware_multiplier": 1.05,
      "hurdle_rate": 0.065,
      "facility_capex_eur_m": 0.7,
      "connection_capex_eur_m": 0.39,
      "operations_labour_multiplier": 0.82,
      "availability": 0.994,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.88,
            "electricity": 1.31,
            "site_grid": 1.85,
            "operations": 3.28,
            "total": 24.33,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 38.31,
            "electricity": 3.56,
            "site_grid": 3.97,
            "operations": 7.62,
            "total": 53.47,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 84.76,
            "electricity": 8.39,
            "site_grid": 8.78,
            "operations": 18.14,
            "total": 120.08,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 22.5,
            "electricity": 1.68,
            "site_grid": 1.9,
            "operations": 5.89,
            "total": 31.97,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 48.21,
            "electricity": 4.56,
            "site_grid": 4.06,
            "operations": 13.83,
            "total": 70.66,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 106.66,
            "electricity": 10.74,
            "site_grid": 8.99,
            "operations": 33.29,
            "total": 159.67,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.18,
          "electricity_eur_kwh": 0.117,
          "electricity_usd_kwh": 0.1341639,
          "utilization": 0.7,
          "availability": 0.994,
          "facility_capex_eur_m": 0.7,
          "connection_capex_eur_m": 0.39
        },
        "datacenter_100mw": {
          "service_units": 612.4,
          "connection_mw": 100,
          "commissioned_it_mw": 87.0,
          "pue": 1.15,
          "electricity_eur_kwh": 0.10764000000000001,
          "electricity_usd_kwh": 0.12343078800000003,
          "utilization": 0.8,
          "availability": 0.9976,
          "facility_capex_eur_m": 818.1924715686838,
          "connection_capex_eur_m": 85.6877223778772,
          "construction_eur_m_per_it_mw": 9.409213423039864
        }
      }
    },
    {
      "code": "SG",
      "country": "Singapore",
      "group": "Asia",
      "electricity_eur_kwh": 0.169,
      "pue": 1.25,
      "landed_hardware_multiplier": 1.05,
      "hurdle_rate": 0.06,
      "facility_capex_eur_m": 0.84,
      "connection_capex_eur_m": 0.55,
      "operations_labour_multiplier": 1.05,
      "availability": 0.997,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 17.7,
            "electricity": 2.01,
            "site_grid": 2.05,
            "operations": 3.44,
            "total": 25.2,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 37.91,
            "electricity": 5.45,
            "site_grid": 4.4,
            "operations": 7.95,
            "total": 55.71,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 83.88,
            "electricity": 12.85,
            "site_grid": 9.72,
            "operations": 18.87,
            "total": 125.32,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 22.23,
            "electricity": 2.57,
            "site_grid": 2.35,
            "operations": 6.52,
            "total": 33.66,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 47.62,
            "electricity": 6.95,
            "site_grid": 5.03,
            "operations": 15.18,
            "total": 74.79,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 105.36,
            "electricity": 16.38,
            "site_grid": 11.12,
            "operations": 36.28,
            "total": 169.13,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.25,
          "electricity_eur_kwh": 0.169,
          "electricity_usd_kwh": 0.19379230000000003,
          "utilization": 0.7,
          "availability": 0.997,
          "facility_capex_eur_m": 0.84,
          "connection_capex_eur_m": 0.55
        },
        "datacenter_100mw": {
          "service_units": 577.2,
          "connection_mw": 100,
          "commissioned_it_mw": 82.0,
          "pue": 1.22,
          "electricity_eur_kwh": 0.15548,
          "electricity_usd_kwh": 0.17828891600000002,
          "utilization": 0.8,
          "availability": 0.9988,
          "facility_capex_eur_m": 860.4036348140911,
          "connection_capex_eur_m": 120.84165976367296,
          "construction_eur_m_per_it_mw": 10.49692434473191
        }
      }
    },
    {
      "code": "AU",
      "country": "Australia",
      "group": "Other",
      "electricity_eur_kwh": 0.121,
      "pue": 1.17,
      "landed_hardware_multiplier": 1.08,
      "hurdle_rate": 0.08,
      "facility_capex_eur_m": 0.72,
      "connection_capex_eur_m": 0.34,
      "operations_labour_multiplier": 1.02,
      "availability": 0.994,
      "evidence_grade": "C",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 18.91,
            "electricity": 1.35,
            "site_grid": 2.05,
            "operations": 3.45,
            "total": 25.76,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 40.51,
            "electricity": 3.65,
            "site_grid": 4.39,
            "operations": 7.98,
            "total": 56.54,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 89.62,
            "electricity": 8.6,
            "site_grid": 9.72,
            "operations": 18.94,
            "total": 126.89,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 23.79,
            "electricity": 1.72,
            "site_grid": 2.0,
            "operations": 6.55,
            "total": 34.06,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 50.96,
            "electricity": 4.67,
            "site_grid": 4.28,
            "operations": 15.25,
            "total": 75.16,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 112.74,
            "electricity": 11.01,
            "site_grid": 9.46,
            "operations": 36.43,
            "total": 169.64,
            "local_uncertainty_pct": 18
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.17,
          "electricity_eur_kwh": 0.121,
          "electricity_usd_kwh": 0.1387507,
          "utilization": 0.7,
          "availability": 0.994,
          "facility_capex_eur_m": 0.72,
          "connection_capex_eur_m": 0.34
        },
        "datacenter_100mw": {
          "service_units": 617.7,
          "connection_mw": 100,
          "commissioned_it_mw": 87.7,
          "pue": 1.14,
          "electricity_eur_kwh": 0.11132,
          "electricity_usd_kwh": 0.127650644,
          "utilization": 0.8,
          "availability": 0.9976,
          "facility_capex_eur_m": 839.4389990023957,
          "connection_capex_eur_m": 74.70211694481601,
          "construction_eur_m_per_it_mw": 9.56960458862731
        }
      }
    },
    {
      "code": "BR",
      "country": "Brazil",
      "group": "Other",
      "electricity_eur_kwh": 0.127,
      "pue": 1.22,
      "landed_hardware_multiplier": 1.25,
      "hurdle_rate": 0.14,
      "facility_capex_eur_m": 0.6,
      "connection_capex_eur_m": 0.32,
      "operations_labour_multiplier": 0.58,
      "availability": 0.982,
      "evidence_grade": "C",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 24.42,
            "electricity": 1.48,
            "site_grid": 2.62,
            "operations": 3.69,
            "total": 32.21,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 52.33,
            "electricity": 4.02,
            "site_grid": 5.61,
            "operations": 8.48,
            "total": 70.45,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 115.77,
            "electricity": 9.47,
            "site_grid": 12.42,
            "operations": 20.06,
            "total": 157.72,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 30.93,
            "electricity": 1.91,
            "site_grid": 2.33,
            "operations": 5.9,
            "total": 41.08,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 66.27,
            "electricity": 5.18,
            "site_grid": 5.0,
            "operations": 13.88,
            "total": 90.33,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 146.62,
            "electricity": 12.2,
            "site_grid": 11.07,
            "operations": 33.43,
            "total": 203.31,
            "local_uncertainty_pct": 18
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.22,
          "electricity_eur_kwh": 0.127,
          "electricity_usd_kwh": 0.1456309,
          "utilization": 0.7,
          "availability": 0.982,
          "facility_capex_eur_m": 0.6,
          "connection_capex_eur_m": 0.32
        },
        "datacenter_100mw": {
          "service_units": 591.8,
          "connection_mw": 100,
          "commissioned_it_mw": 84.0,
          "pue": 1.19,
          "electricity_eur_kwh": 0.11684000000000001,
          "electricity_usd_kwh": 0.133980428,
          "utilization": 0.8,
          "availability": 0.9928,
          "facility_capex_eur_m": 720.8390145739588,
          "connection_capex_eur_m": 70.30787477159154,
          "construction_eur_m_per_it_mw": 8.57798427343011
        }
      }
    },
    {
      "code": "CL",
      "country": "Chile",
      "group": "Other",
      "electricity_eur_kwh": 0.105,
      "pue": 1.17,
      "landed_hardware_multiplier": 1.12,
      "hurdle_rate": 0.105,
      "facility_capex_eur_m": 0.59,
      "connection_capex_eur_m": 0.3,
      "operations_labour_multiplier": 0.66,
      "availability": 0.988,
      "evidence_grade": "C",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 20.55,
            "electricity": 1.17,
            "site_grid": 2.12,
            "operations": 3.38,
            "total": 27.22,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 44.03,
            "electricity": 3.18,
            "site_grid": 4.55,
            "operations": 7.82,
            "total": 59.58,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 97.42,
            "electricity": 7.48,
            "site_grid": 10.06,
            "operations": 18.6,
            "total": 133.56,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 25.94,
            "electricity": 1.51,
            "site_grid": 1.91,
            "operations": 5.69,
            "total": 35.05,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 55.58,
            "electricity": 4.08,
            "site_grid": 4.09,
            "operations": 13.41,
            "total": 77.17,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 122.97,
            "electricity": 9.61,
            "site_grid": 9.06,
            "operations": 32.37,
            "total": 174.01,
            "local_uncertainty_pct": 18
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.17,
          "electricity_eur_kwh": 0.105,
          "electricity_usd_kwh": 0.1204035,
          "utilization": 0.7,
          "availability": 0.988,
          "facility_capex_eur_m": 0.59,
          "connection_capex_eur_m": 0.3
        },
        "datacenter_100mw": {
          "service_units": 617.7,
          "connection_mw": 100,
          "commissioned_it_mw": 87.7,
          "pue": 1.14,
          "electricity_eur_kwh": 0.0966,
          "electricity_usd_kwh": 0.11077122000000002,
          "utilization": 0.8,
          "availability": 0.9952,
          "facility_capex_eur_m": 744.904934339514,
          "connection_capex_eur_m": 65.91363259836707,
          "construction_eur_m_per_it_mw": 8.49191625147046
        }
      }
    },
    {
      "code": "SA",
      "country": "Saudi Arabia",
      "group": "Other",
      "electricity_eur_kwh": 0.056,
      "pue": 1.24,
      "landed_hardware_multiplier": 1.08,
      "hurdle_rate": 0.078,
      "facility_capex_eur_m": 0.62,
      "connection_capex_eur_m": 0.3,
      "operations_labour_multiplier": 0.72,
      "availability": 0.992,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 18.85,
            "electricity": 0.66,
            "site_grid": 1.86,
            "operations": 3.34,
            "total": 24.71,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 40.39,
            "electricity": 1.8,
            "site_grid": 3.98,
            "operations": 7.73,
            "total": 53.9,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 89.36,
            "electricity": 4.23,
            "site_grid": 8.8,
            "operations": 18.4,
            "total": 120.79,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 23.75,
            "electricity": 0.85,
            "site_grid": 1.72,
            "operations": 5.71,
            "total": 32.02,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 50.88,
            "electricity": 2.3,
            "site_grid": 3.68,
            "operations": 13.45,
            "total": 70.31,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 112.56,
            "electricity": 5.41,
            "site_grid": 8.14,
            "operations": 32.46,
            "total": 158.57,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.24,
          "electricity_eur_kwh": 0.056,
          "electricity_usd_kwh": 0.0642152,
          "utilization": 0.7,
          "availability": 0.992,
          "facility_capex_eur_m": 0.62,
          "connection_capex_eur_m": 0.3
        },
        "datacenter_100mw": {
          "service_units": 582.0,
          "connection_mw": 100,
          "commissioned_it_mw": 82.6,
          "pue": 1.21,
          "electricity_eur_kwh": 0.05152,
          "electricity_usd_kwh": 0.05907798400000001,
          "utilization": 0.8,
          "availability": 0.9968,
          "facility_capex_eur_m": 723.0097248828722,
          "connection_capex_eur_m": 65.91363259836707,
          "construction_eur_m_per_it_mw": 8.748417671082754
        }
      }
    },
    {
      "code": "AE",
      "country": "United Arab Emirates",
      "group": "Other",
      "electricity_eur_kwh": 0.105,
      "pue": 1.25,
      "landed_hardware_multiplier": 1.07,
      "hurdle_rate": 0.073,
      "facility_capex_eur_m": 0.72,
      "connection_capex_eur_m": 0.37,
      "operations_labour_multiplier": 0.85,
      "availability": 0.995,
      "evidence_grade": "B",
      "scales": {
        "datacenter_100mw": {
          "general": {
            "hardware": 18.49,
            "electricity": 1.25,
            "site_grid": 1.98,
            "operations": 3.38,
            "total": 25.1,
            "local_uncertainty_pct": 18
          },
          "long_context": {
            "hardware": 39.61,
            "electricity": 3.39,
            "site_grid": 4.25,
            "operations": 7.83,
            "total": 55.08,
            "local_uncertainty_pct": 18
          },
          "agentic": {
            "hardware": 87.63,
            "electricity": 7.99,
            "site_grid": 9.4,
            "operations": 18.61,
            "total": 123.63,
            "local_uncertainty_pct": 18
          }
        },
        "onprem_250kw": {
          "general": {
            "hardware": 23.24,
            "electricity": 1.6,
            "site_grid": 1.98,
            "operations": 6.03,
            "total": 32.85,
            "local_uncertainty_pct": 12
          },
          "long_context": {
            "hardware": 49.8,
            "electricity": 4.33,
            "site_grid": 4.23,
            "operations": 14.13,
            "total": 72.5,
            "local_uncertainty_pct": 12
          },
          "agentic": {
            "hardware": 110.18,
            "electricity": 10.2,
            "site_grid": 9.37,
            "operations": 33.96,
            "total": 163.7,
            "local_uncertainty_pct": 12
          }
        }
      },
      "scale_inputs": {
        "onprem_250kw": {
          "service_units": 1.0,
          "connection_mw": 0.25,
          "pue": 1.25,
          "electricity_eur_kwh": 0.105,
          "electricity_usd_kwh": 0.1204035,
          "utilization": 0.7,
          "availability": 0.995,
          "facility_capex_eur_m": 0.72,
          "connection_capex_eur_m": 0.37
        },
        "datacenter_100mw": {
          "service_units": 577.2,
          "connection_mw": 100,
          "commissioned_it_mw": 82.0,
          "pue": 1.22,
          "electricity_eur_kwh": 0.0966,
          "electricity_usd_kwh": 0.11077122000000002,
          "utilization": 0.8,
          "availability": 0.998,
          "facility_capex_eur_m": 784.3938187399435,
          "connection_capex_eur_m": 81.29348020465272,
          "construction_eur_m_per_it_mw": 9.56960458862731
        }
      }
    }
  ]
}